Loading...
HomeMy WebLinkAbout3537LT-1CITY OF FONTANA TRACT N0. 16271-1 STREET LIGHT EXHIBIT GENERAL NOTES a aavva.v 1 LOCATION 1. ORNAMENTAL STREET LIGHT POLES SHALL BE MARBLELITE OR APPROVED EQUAL. 2. THE LIMINAIRE SHALL CONSIST OF COBRA HEAD CUT-OFF LENS ON A 6 FT OR 8 FT MAST ARM. 15 FT MAST ARM REQUIRED FOR STREET LIGHTS ON TRAFFIC SIGNAL POLE INSTALLATIONS. 3. ANY CHANGE IN LOCATION OF STREET LIGHTS FROM THE APPROVED PLANS IS SUBJECT TO APPROVAL BY THE CITY ENGINEER. 4. SIDEWALK WIDTHS TO BE PER APPROVED STREET IMPROVEMENT PLANS. A MINIMUM OF 4 FEET UNOBSTRUCTED SIDEWALK CLEARANCE REQUIRED BEHIND STREET LIGHT POLE. 5. ALL STREET LIGHTS SHALL BE INSTALLED PER CITY STD. DWG. NO. 1016. OPROPOSED FIRE HYDRANT LTJ EXISTING FIRE HYDRANT LEGEND 5800 LUMEN 8 9500 LUMEN 2 TOTAL 10 ruenome: m:\uwb\IZ,fU0\txhitsiiIL.awg 0 LEGEND 5800 LUMEN, 70 WATT H.P.S.V. # 7 LAMP ON 25' MARBELITE POLE OR APPROVED EQUAL. sr/ EXISTING STREET LIGHT 9500 LUMEN, 100 WATT H.P.S.V. # 10 LAMP ON 25' MARBELITE POLE OR APPROVED EQUAL. OFUTURE 9500 LUMEN, 100 WATT H.P.S.V. # 10 LAMP ON 25' MARBELITE POLE OR APPROVED EQUAL. OPROPOSED FIRE HYDRANT LTJ EXISTING FIRE HYDRANT LEGEND 5800 LUMEN 8 9500 LUMEN 2 TOTAL 10 ruenome: m:\uwb\IZ,fU0\txhitsiiIL.awg