HomeMy WebLinkAbout3525-1STORr.vl DRAIN lfwlPROVEMENT NOTES
1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF
FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD
SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK'). ALL
REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION
UNLESS OTHERWISE NOTED.
2. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA
COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO
THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED
AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC
RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909)350-7610.
3. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN
VALVES. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER
COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS.
4. STATIONING REFERS TO THE CENTERLINE OF STORM DRAIN EXCEPT WHERE
OTHERWISE NOTED.
5. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED
PRIOR TO PAVING OF STREETS.
6. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE
INFORMATION. HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR TO DETERMINE IN THE FIELD, THE TRUE LOCATION AND
ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION
TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT
UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE
EXCAVATION.
7. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE
RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION
OF PAVING.
8. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY'
COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC,
CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER,
RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS.
ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR
TO WORK AROUND THEIR FACILITIES.
9. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE
ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY
ENGINEER.
10. WHEN CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN
NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN
BOOK", THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE
CITY ENGINEER FOR RESOLUTION.
11. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT
PRIOR TO PLACEMENT.
12. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND
FINISH TO MATCH EXISTING CONCRETE.
12A. ALL REINFORCED CONCRETE SHALL BE 3,250 PSI, AT 28 DAYS, PORTLAND
CEMENT TYPE IV.
13. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL
HAVE BEEN PLACED, INSPECTED AND APPROVED.
14. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN
DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER
APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF
INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE
(5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND
MOVEMENT.
15. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR
TRENCH WORK FOR TRENCHES FIVE (5) FEET OR GREATER IN DEPTH FROM THE
CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
16. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE
CITY INSPECTOR.
17. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR
DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO
THE RIGHT-OF-WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN
APPROVAL.
18. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN
BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL AT ALL TIMES.
19. A GEOTECHNICAL- ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION.
FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF
THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED.
20. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY
ENGINEER.
21. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEERS
TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN
GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION
OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING
CONSTRUCTION.
22. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM
UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE
CITY ENGINEER MAY REQUIRE TEMPORARY- NON-ERODEABLE SWALES ENTERING
OR LEAVING IMPROVEMENTS.
23. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE
PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER
AND ALL AFFECTED AGENCIES IMMEDIATELY.
24. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS,
MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY
ENGINEER.
25. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING
SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY
A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY
MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION
SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE
WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE
ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT.
26. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND
BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT
ALL TIMES IN THE CLOSURE AREA FOR RESIDENTS AND EMERGENCY VEHICLES.
27. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT-OF-WAY
WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE.
28. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING
FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY
APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY
CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS.
29. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF
DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES.
30. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES,
METHODS AND PROCEDURES DESCRIBED IN THE "W.A.T.C.H. MANUAL", LATEST
EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER.
31. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL
SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO
THE SATISFACTION OF THE CITY TRAFFIC ENGINEER.
32. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN
BARRICADES, DEUNEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL
TIMES.
33. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT
PRIOR APPROVAL OF THE CITY ENGINEER.
p
34. MINIMUM D -LOAD FOR ALL REINFORCED CONCRETE PIPE (RCP) IS 1350.
0
�S li�[�Cvd DD L�LaO�] OMFR (0MM\-/ [,�Vir
IT CM MAP moo.
BENCH MARK:
EL = 1077.40
CHISELED BOX IN EASTERLY TOP CURB,
TAMARIND AVE.; 60' SOUTH OF TAMARIND
CT., 500' SOUTH OF SLOVER
THE BEARINGS SHOWN HEREON ARE BASED ON
THE CENTERLINE OF JURUPA AVENUE BEING
NORTH B9'04'00" EAST PER TRACT NO. 16074
P.M.B. 278/78-92
DIAL TWO WORKING
BEFORE DAYS BEFORE
YOU DIG YOU DIG
TOLL FREE 1-800-227-2600
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
Q?,pfESS/o
C.CD
No.63494
Exp. Sept. 30, 2008
J' civil-
T�TF OF CAL
INDEX MAP
-- - : 1" = 100'
MATTHEW C. HICKS
RCE NO. 63494 EXP. 09-30-08
REV.
REVISION DESCRIPTION
DATE
ENGR.
CITY
DATE
DOMESTIC WATER
RCP -
REINFORCED CONCRETE PIPE
CB -
CATCH BASIN
INV -
INVERT
SS -
SANITARY SEWER
DW
- DOMESTIC WATER
TC
- TOP OF CURB
GB
- GRADE BREAK
FS
- FINISHED SURFACE
EMPIRE LAND, LLC
SHT. 4 LINE "D"
3536 CONCOURS ST.
SHT. 5 LINE "I"
ONTARIO, CA 91764
SHT. 6 LINE "I"
(909) 987-7788
ADD HYDRAULIC DATA TO PROFILE; RECORD DWG.
03/08
MCH1;;�2
qlt ee
SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT
COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL
SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER,
THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS
TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND
STANDARDS IN EFFECT.
UTILITY CONTACTS
ELECTRICITY
SOUTHERN CALIFORNIA EDISON CO.
300 N. PEPPER AVE.
RIALTO, CA 92376
UNDERGROUND: (909) 357-6233
TRANSMISSIONS: (909) 875-5100
_ - e PIPELINES: (213) 657-1233
DISTRIBUTION: (909) 357-6233
GAS
SOUTHERN CALIFORNIA GAS CO.
1981 LUGONIA AVE.
REDLANDS, CA. 92374
ATTN: JOHN OATES
EMERGENCIES: (800) 427-2200
WATER
WEST SAN BERNARDINO COUNTY
WATER DISTRICT
855 WEST BASELINE, P.O. BOX 920
RIALTO, CALIFORNIA 92377-0920
(909) 875-1804
PACIFIC BELL
4025 LA PALMA STREET
ANAHEIM, CA. 92807
(714) 237-6146
ATTN: DELIA LERMA
�---'" SEWER
CITY OF FONTANA
8353 SIERRA AVENUE
P.O. BOX 518
FONTANA, CA 92335
(909) 350-6632
ATTN: CARLOS NAVARRO
COMCAST CABLEVISION
1205 DUPONT AVE
ONTARIO, CA 91761
(909) 390-4738
CONTACT: JACK HAYES
w
VICINITY H., AP
NOT TO SCALE
NOTICE TO CONTRACTOR
1. THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE SHOWN IN AN
APPROXIMATE WAY ONLY AND HAVE NOT BEEN INDEPENDENTLY VERIFIED BY
THE OWNER OR ITS REPRESENTATIVE. THE CONTRACTOR SHALL DETERMINE
THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING
WORK, AND AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES
WHICH MIGHT BE OCCASIONED BY THE CONTRACTOR'S FAILURE TO EXACTLY
LOCATE AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES.
2. IT IS THE CONTRACTORS RESPONSIBILITY TO CONTACT UNDERGROUND
SERVICE ALERT (PHONE: 1-800-227-2600.) 48 HOURS IN ADVANCE OF ANY
EXCAVATION FOR THE MARK -OUT OF THE LOCATION OF UTILITIES AND
NOTIFICATION OF COMMENCEMENT OF WORK.
3. CONTRACTOR WILL MAKE EXPLORATION EXCAVATIONS AND LOCATE
EXISTING UNDERGROUND FACILITIES SUFFICIENTLY AHEAD OF CONSTRUCTION
TO PERMIT REVISIONS TO PLANS IF REVISIONS ARE NECESSARY. NOTIFY
THE ENGINEER OF WORK IF ANY DISCREPANCIES IN UTILITY LINE
LOCATIONS ARE FOUND.
4. LOCATIONS AND ELEVATION OF IMPROVEMENTS TO BE MET BY WORK TO BE
DONE SHALL BE CONFIRMED BY FIELD MEASUREMENTS PRIOR TO
CONSTRUCTION OF NEW WORK.
5. CONTRACTOR IS REQUIRED TO TAKE PRECAUTIONARY MEASURES TO
PROTECT THE UTILITY LINES SHOWN HEREON AND ANY OTHER EXISTING
LINES NOT OF RECORD OR NOT SHOWN ON THESE PLANS.
6. A PRE CONSTRUCTION CONFERENCE SHALL BE HELD PRIOR TO THE START
OF ANY CONSTRUCTION AS SHOWN ON THIS SET OF PLANS. CONTRACTORS
ATTENDANCE IS MANDATORY.
7. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO PURCHASE A
CURRENT COPY OF ALL APPLICABLE STANDARD DRAWINGS PRIOR TO THE
START OF ANY CONSTRUCTION SHOWN WITHIN THIS SET OF PLANS.
LEGEND
-
PROPOSED STORM DRAIN
-
EXISTING STORM DRAIN
SANITARY SEWER
DOMESTIC WATER
RCP -
REINFORCED CONCRETE PIPE
CB -
CATCH BASIN
INV -
INVERT
SS -
SANITARY SEWER
DW
- DOMESTIC WATER
TC
- TOP OF CURB
GB
- GRADE BREAK
FS
- FINISHED SURFACE
E
0
N
D
SHEET INDEX
SHT. 1 GENERAL NOTES, VICINITY MAP AND INDEX MAP
STORM DRAIN IMPROVEMENT PLANS
OWNER/DEVELOPER
SHT. 2 DETAILS & QUANTITIES
SHT. 3 DETAILS
EMPIRE LAND, LLC
SHT. 4 LINE "D"
3536 CONCOURS ST.
SHT. 5 LINE "I"
ONTARIO, CA 91764
SHT. 6 LINE "I"
(909) 987-7788
SHT. 7 LINE "I"
Q
CONTACT: JIM MULLINS
PLANNING ■ DESIGN ■ CONSTRUCTION
CITY OF FONTANA CALIFORNIA
Q%pVESSJO
3536 CONCOURS, SUITE 220
ONTARIO, CALIFORNIA 917645592
909.581.0192
STORM DRAIN IMPROVEMENT PLANS
� - / F`
�� `Z
■ A
909.581.0196 ■ FAX ■ www.RBF.com
SCALE:
DRAWN BY: TRACT 16495 NTS
W No. 63494 r"
CONSULTING
J. S. TIT SHEET JOB NUMBER
'
Exp. 9/30/06 ,
PREPAR U HE
U ER SION OF:
DESIGNED BY: 15-100634
Q
sIf � I V l ��`�
lF
/r
J. S. PP Y DRAWING N0. 1
a
DATE: ���
CHECKED BY:
3525
MA HEW C. HICKe r
vRCE NO. 63494 EXP. 09-30-06
j!,w1jWjR. J. B• RI ARDO ANDOVAL R.C.E. 51152 DATE:
4