HomeMy WebLinkAbout3524-1- GENERAL NOTES FOR SE LYER 1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED. 2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION. 3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER. 4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS, AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL AT ALL TIMES. 7. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. 8. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT. 9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT-OF-WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE. 10. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION. HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION. 11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES. 12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS. 13. STATIONING REFERS TO THE CENTERLINE OF SEWER EXCEPT WHERE OTHERWISE NOTED. 14. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE'PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION. 15. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCHMARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER. 16. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCHMARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT. 17. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CLOSURE AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 18. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES. 19. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT-OF-WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL. 20. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 21. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED. 22. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS. 23. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE. 24. IF SEWER CONSTRUCTION IS TO BE DONE IN PHASES, THE CONTRACTOR SHALL PROVIDE A TERMINAL CLEANOUT AT THE PHASE BOUNDARY, NOT MORE THAN 150 FEET FROM THE DOWNSTREAM MANHOLE, SEE CITY OF FONTANA STANDARD DETAIL FOR TERMINAL CLEANOUT. 25. SANITARY SEWER LINES SHALL BE CONSTRUCTED OF BELL AND SPIGOT OR BAND SEAL TYPE VITRIFIED CLAY PIPE (V.C.P.) EXTRA STRENGTH CLASS AND SHALL CONFORM TO THE PROVISIONS OF THE ASTM DESIGNATION C700 FOR V.C.P. 26. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE CITY ENGINEER. 27. SHORT VCP STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED AT MANHOLE WALLS TO ALLOW FOR MINOR DEFLECTIONS IN ALIGNMENT. 28. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS. 29. ALL 4" HOUSE LATERALS SHALL BE INSTALLED AT A 2% MINIMUM GRADE UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER. 30. TERMINATE ALL 4" HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH A PLUG 12" BELOW THE GROUND SURFACE. WHEN PUBLIC UTILITY EASEMENTS EXIST NEXT TO THE STREET RIGHT-OF- WAY, THE LATERAL SHALL TERMINATE 3 FEET INSIDE THE LOT AS MEASURED FROM THE UTILITY EASEMENT. 31. THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE CURB AT THE LOCATION OF THE SEWER LATERAL. 32. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY. 33. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. 34. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS. mamaaLm REIN T ---------- ----------- TT��# SO-Kli #57 I 67 � 9 38 ? 79 78 77 76 75 4,3742, 41 40 .. 74 71 707��6 73 72 16 ------------------ E I 82 37 E 100 101 � I 19 36 83 MH 102 142 , 18 MH. ' 51 84 �---- 17 20 35 - 99 141 3u 85 gg 03 16 _ 21 MH # ! �/ 33 86 97 104 15 I 22 a � W 87 96 � 14 23 32 MH#47 105 �' _4j i 88 95 13 24 31 -___-4f -- --- - ;' 89 I -A yCOD MH#60: 25 30 J 94 124 12 10 26 I MH � 93 �....� _ 125 11 �i 91 10 28MH#92 52 126 qc:C 9 : 11 _ GJ?EEAl, TRE 127 I 5� Vj _ MH # 50 128 1 g 129 7 114 1 3 112 111 110 109 108 107 106 � I a I _I I 130 ; 115 116 117 118 119 1201121 1221 123 131 5 , !� Sa" 13 2 4 H#49 I M,7#44 �..... 3140 139 138 137 136135 ' 134' 133 I h E 2 1 � / a € RAINTREE LA11SE SEWER LEGEND® --(EX. 8" s)---- ------ ..._._. EXISTING OR PROPOSED _BY OTHERS SEWER MAIN NEW SEWER MAIN PROPOSED MANHOLE EXISTING OR PROPOSED BY OTHERS SEWER MANHOLE - SERVICE LATERAL THIS LOT REQUIRES A BACKWATER VALVE PER SECT. 409 OF U.P.C. in; VICINITY M., AP NOT TO SCALE UTILITY CONTACTS ELECTRICITY SOUTHERN CALIFORNIA EDISON CO. ' 300 N. PEPPER AVE. RIALTO, CA 92376 UNDERGROUND: (909)'157-6233 TRANSMISSIONS: (909) 875-5100 PIPELINES: (213) 657-1233 DISTRIBUTION: (909) 357-6233 GAS SOUTHERN CALIFORNIA GAS CO. 1981 LUGONIA AVE. REDLANDS, CA. 92374 ATTN: JOHN GATES EMERGENCIES: (800) 427-2200 WATER WEST SAN BERNARDINO COUNTY WATER DISTRICT 855 WEST BASELINE, P.O. BOX 920 RIALTO, CALIFORNIA 92377-0920 (909) 875-1804 PACIFIC BELL 4025 LA PALMA STREET ANAHEIM, CA. 92807 (714) 237-6146 ATTN: DELIA LERMA SEWER CITY OF FONTANA 8353 SIERRA AVENUE P.O. BOX 518 FONTANA, CA 92335 (909) 350-6632 ATTN: CARLOS NAVARRO COMCAST CABLEVISION 1205 DUPONT AVE ONTARIO, CA 91761 (909) 390-4738 CONTACT: JACK HAYES E N v 35. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO _ ENGINEER'S NO T►CE TO Lr ON TRA C TORS' In _ PLACEMENT. I - ( - I ,A-, - -^ - - - - - - a- 36. 36. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED 1 ° fNDE-R tJ O n n a � E , W THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE � � w --rte � r� GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING.PLANS ARE t THERE ARE NOEXISTING UTILITIES EXCEPTTHOSESHOWNON THIS PLN. THE CONTRACTORISREQUIRED OBTAINED NBCAHAD' 37. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, � � � 1 � BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY 143 w TO TAKE ALL PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN, AND ANY OTHER LINES OR `' TRAFFIC ENGINEER. STRUCTURES NOT SHOWN ON THESE PLANS, AND IS RESPONSIBLE FOR PROTECTION OF AND ANY DAMAGE � RZ® TO THESE LINES OR STRUCTURES. _ 38. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, p w WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER. CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION Of PRACTICES, CONSTRUCTION CONTRACTORS WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE w �(ER�DEEL OPER RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT. O tr�/�eINCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY QOLpFESSIOHq AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO, EMPIRE LAND C. FyREALORDEFEND, ALLEGED, INDEMNIFYI NAND CONNECT I ONDESIGN WITH PROFESSIONAL PERFORMANCE OFNWORKHARMLESS THIS FPROJECT AND ALL LIABILITY , o 3536 CONCOURS AVE, SUITE 300 INDEX MAP y N ?r CD No. 63494 THE CONTRACTOR SHALL BE RESPONSIBLE TO REPORT DISCREPANCIES IN PLANS AND/OR FIELD CONDITIONS n ONTARIO, CA 91764-5592 SCALE 1" = 100' " (909) 987-7788 �. Sept.so, Zoos DATE: K -' IMMEDIATELY TO THE DESIGN ENGINEER FOR RESOLUTION PRIOR TO CONSTRUCTION AND SHALL BE RESPONSIBLE CONTACT: JIM MULLINS °C { �} 0 FOR DISCREPANCIES NOT SO REPORTED AND RESOLVED. > MATTHEW C. HICKS `�lqp CiVt%� ��- RCE NO, 63494 EXP. 09-30-08 CAUTION: THE ENGINEER PREPARING THESE PLANS WILL NOT RESPONSIBLE FOR, OR LIABLE FOR , UNAUTHORIZED p 'SOF CAOCHANGES OR USES OF THESE PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND MUST BE APPROVED p BENCH MARK: BY THE PREPARER OF THESE "PLANS". zz J EL = 1077.40 p O REV. REVISION DESCRIPTION DATE ENGR. CITY DATE �„A PLANNING 0 DESIGN ■ CONSTRUCTION /� /� p CHISELED BOX IN EASTERLY TOP CURB, CITY OF FONTANA, CALIFORNIA U 60'Q�p f E S S 1 pH .�✓° 3536 CONCOURS, SUITE 220 `A' TAMARIND AVE.; OF SOUTH of TAMARIND SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT �w 9� ONTARIO CALIFORNIA 91764-5592 SEWER IMPROVEMENT � cT., 500' SOUTH of sLovER COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL ,��� ��� 909.581.0196 ■ FAX 909.581.0192 • www.RBF.com PLAN 0 SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER = N Z ® ® ® DRAWN BY: SCALE: o BASIS OF DIAL TWO WORKING THE CITY ENG I NEER MAY REQUIRE REVISIONS TO THE PLANS TO No .63494 CONSU LT I N G M E GENERAL NOTES NTsLn THE BEARINGS HEREON ARE BASED ON THE BEFORE ���.� DAYS BEFORE � Exp. 9/30/06 JOB NUMBER CENTERLINE OF JURUPA AVENUE SHOWN As YOU DIG YOU SIG STAND THEM INTO CONFORMANCE WITH CONDITIONS AND slq �i�i� ���� PREFAB R E su,ER ON OF: DESIGNED R G T 16495 15-100636 ARDS I N EFFECT. rF APP VED DRAWING NO. 1 NORTH 89'04'00" EAST PER PARCEL MAP N0. TOLL FREE 1-800-227-2600 OF C p`t � DATE: �•� � CHECKED BY: � � �•� 16074 P.M.B. 278/78-92. A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT 03/08 MCH.G op '3524 1 RECORD DWG. (� MA HEW C. HICKS RCE N0. 63494 EXP. 09-30-06 BNI� • J • RI A DO SANDOVAL R.C.E. 51152 A TE: 8 -