Loading...
HomeMy WebLinkAbout3518-3S'E RIGHT 112' 22" 1 jl�fl22'_11 12' 5' I , 6 , LOT A _z 5 i G Dol N T ACT 60. 139 138 36" RCP SDS PER CITY BY OTS DRAWING NO 3519 15 137 3 2 1 1 2 136 1 135 134 TRACT NO. 133 J6�495-2 / 12 12" SEWER XING 24" RCP SO R/W LOT B — — -- -- -- 10 " N �. " rt N Lo +44.50 UNDERWOOD DRIVE 1+00.00 SOURWOOD WAY C MH NO. 26 BENCH MARK: EL = 1077.40 CHISELED BOX IN EASTERLY TOP CURB, TAMARIND AVE.; 60' SOUTH OF TAMARIND CT., 500' SOUTH OF SLOVER BASIS OF BEARINGS: THE BEARINGS HEREON ARE BASED ON THE CENTERLINE OF JURUPA AVENUE SHOWN AS NORTH 89'04'00" EAST PER PARCEL MAP NO. 16074 P.M.B. 278/78-92. m — —— R/W � 4+76.00 2 ;7 o3+22.25 UNDERWOOD DRIVE q MH NO. 25 143 TRACT BSO. 16495 I III ' 0 oil 1+00.00 UNDI 6+40.00 SAS CL MH NO. 24 33 A LOT E i SEWER & WATER EASEMENT i 05 A 1 _00\ 1 SASSAFRAS COURT SEE SHEET 10 W LfGl .7 �': Me. 14 MATTHEW C. HICKS RCE NO. 63494 EXP. 09-30-08 DATE: C -til}. UNECURVE DATA TABLE ® BEARING/DELTA RADIUS LENGTH TANGENT 1 N89 2742"E -- 222.25' -- 2 N89 2742"E -- 222.25' -- 3 N00'32'18"W -- 57.00' -- PROFILE SCALE HORIZ. 1" = 40' VERT. 1" = 4' SEMIER CONSTRUCTION NOTES: 0 INSTALL 12" EXTRA STRENGTH VCP SEWER LINE ® INSTALL 48" I.D. MANHOLE PER CITY OF FONTANA STD. 112 Q7 INSTALL 6" COMMERCIAL SEWER LATER4L & CLEAN-OUT PER CITY OF FONTANA STD. 125 UNDERWOOD DRIVE1+11.00 POST OAK LANE 12 SEWER XING 24" RCP SD I I 1+20.00 1 12' 22' 2 12' 12" WATER XING y 12" SEWER 6 I 116 15'--1 ej 1+57.00 I SEE TR 16495 END PIPE -PLUG SEWER PLANS DWG NO. 3524 1+00.00 SOURWOOD WAY I R/W-:>LOT A I SHT NO. 3 5+44.50 UNDERWOOD DRIVE I N FOR CONTINUA110N MH NO. 26 1 �' 3/ 1 2 N `n � . 117 Z Oc CC 5'> I1 � UNDERWOOD DRIVE SEE LEFT v o niAl rr^^ ���qppp6 cc R/W ATL O T B I ~ I9 118 2" SEWER V.C.P. 2 5 V Y OF I I 3 140 iII I POST OAFS LANE 40' 30' 20' 10' 0' 40' 80' GRAPHIC SCALE. 1"=40' O DIAL TW❑ W❑RK I NG BEFORE ����� DAYS BEF❑RE YOU DIG '' You DIG TOLL FREE 1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT REV. REVISION DESCRIPTION DATE ENGR. CITY DATE SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL HEREON AND CARRIED FORTH IN A DILIGENT MANNER , THE CITY ENG I NEER MAY REQUIRE REV I S I ONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND STANDARDS I N EFFECT. QROFEss1pN �o w 9� ��� ��' yf� ��, N W No . 63494 EXP 9/�/� sr c i v IV �`� 9TF OF C A�l`` PLANNING ® DESIGN ■ CONSTRUCTION 3535 CONCouRs, SUITE 220 ONTARIO, CALIFORNIA 91764-5592 909.581.0196 ■ FAX 909.581.0192 • www.RBF.co CONSULTING PREPAR D UN R T SUE ISI OF: DATE: CITY OF FONTANA, CALIFORNIA SEWER IMPROVEMENT PLANS DRAWN BY: B.B. U: DERWOOD DRIVE & SOURWOOD WAY TRACT 16495-1 SCALE: " = 40' JOB NUMBER 15-100634 DESIGNED BY: B C CKED R.J. A�PP'ROVFQ ���i 3/4/O� (•t��L DRAWING N0. 3 0-3 3518 12 2 RECORD DRAWING 04/08 �9'!%8 MATT EW C. HICKS RCE N0. 63494 EXP. 09-30-06 RICARDO SANDOVAL R.C.E. 51152 DATE: E r3 N T_