HomeMy WebLinkAbout3517-4IMPROVEMENTS
PER SIERRA AVE
STREET PLANS
ON FILE AT THE
Cl TY OF
FONTANA
DWG. NO. 2053
LEGEND
I
3
66'
62'
PROP. A.C. PAVEMENT
EXIST. A.C. PAVEMENT TO BE
SAWCUT AND REMOVED. THEN
REPLACED PER LAP JOINT
DETAIL ON SHEET 2
OF
FONTANA TED USE AREA.
140 CITY
' PROP. CONCRETE SIDEWALK
Lu w
M
i
MATTHEW C. HICKS
RCE N0. 63494 EXP. 09-30-08
TOLL FREE —800-227-2600
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
/L W -U
-r\--0.40
,
SOURWOOD WA Y
I I i I
7 8 9 10 11
O
O
O
Q�
~' W
yW
�ca
.vLu
V
E►
40' 30' 20' 10' 0' 40' 80'
GRAPHIC SCALE. 1"=40'
PROFILE SCALE
HORIZ. 1" = 40'
VERT. 1" = 4'
CONSTRUCTION NOTES.-
1
OTES:1 CONSTRUCT 4" MIN A.C. OVER 95% COMPACTED NATIVE SOIL
CONSTRUCT 8" CURB AND GUTTER PER CITY OF FONTANA STD. 4993
4 CONSTRUCT 6"-8" CURB RETURN TRANSITION (SEE PROFILE)
5 CONSTRUCT CONCRETE SIDEWALK (W=5) PER CITY OF FONTANA STD. �$1
66 CONSTRUCT ACCESS RAMP PER CITY OF FONTANA STD. 1006
O7 CONSTRUCT CROSS GUTTER (W=10') PER CITY OF FONTANA STD. 104
OS SAWCUT AND REMOVE EXISTING A.C. PAVEMENT, REPLACE WITH PROPOSED PAVEMENT
AND FEATHER TO MEET EXISTING GRADE PER LAP JOINT DETAIL ON SHEET 2
O9 CONSTRUCT LOCAL DEPRESSION PER APWA STD. 313-1 PER DETAIL ON SHEET 3
10 CONSTRUCT 4.5" MIN A.C. OVER 957. COMPACTED NATIVE SOIL
11 INSTALL BARRICADE PER CITY OF FONTANA STD. 118
12 REMOVE EXIST. CURB, GUTTER, CROSS GUTTER, AND SIDEWALK
PER APPROVED METHODS
26 REMOVE EXISTING ACCESS RAMP
28 CONSTRUCT DRIVEWAY PER CITY OF FONTANA STD. NO, -16119&4
Z9 CONSTRUCT PCIDIFIED LOCAL DEPRE55IDM PE/Z DE rA/L A DU SHEET 2
CURVE/LINE DATA TABLE
Q
DELTA
RADIUS
LENGTH
TANGENT
REMARK
A
90'00'00"
30.00'
47.12'
30.00'
CURB RETURN
B
90,00,00"
35.00'
54.98'
35.00'
CURB RETURN
C
66 25'19"
20.00'
23.19'
13.09'
DRIVE ENTRY
D
90 00'00"
7.17'
11.26'
7.17'
DRIVE ENTRY
�� �o
-
4.83'
-
DRIVE ENTRY
FEN0032'18"W
N89'Z7`4Z"E
-
ZL.53'
-
CU
28 L/AlE
No. 68513
ExP6.o7 DAVID EVAN S
Civt�. �P � ANDASSOCIATES iHc.
4ZOO CONEDURS 50TE ZDV
C°A�"`�
wm ON74F0 CALIFDRVIA 717!04
PI4DNE 9D9.48l.575D
a
REV.
REVISION DESCRIPTION
DATE
ENGR.
CITY
DATE
SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT
COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL
SHOWN HEREON AND CARRIED FORTH I N A D I L I GENT MANNER ,
1"HE CITY ENG I NEER MAY REQUIRE REV I S I ONS TO THE PLANS TO
RING THEM INTO CONFORMANCE WITH CONDITIONS AND
IN EFFECT.
FEgg1p
9�
��� `��yj� �`�,
�No. 63494
xp.9/30/0UNDER
-4PREPARE
sc tu ���
'�FFAPPR
9F pit
PLANNING ■ DESIGN ■ CONSTRUCTION
3536 CONCOURS, SUITE 220
ONTARIO, CALIFORNIA 91764-5592
909.581.0196 ■ FAX 909.581.0192 ■ www.RBF.com
■
C G N S U LTI N G
UNDE H UPE ISI OF:
'
_ DATE: 9j- O
CITY OF FONTANA, CALIFORNIA
STREET IMPROVEMENT PLANSRECORD
DRAWN BY:
RGPj.
DESIGNED BY:
TRACT 16495-1SCALE
OD DRIVE
„ =
JOB NUMBE1
15-10STANDARDS
JR
DRAWING
04/08
!l
�� �o
I�EV/SED DRIVEWAY FOR CCI71R1ERC/AL CL -2
C SFED D V EW AV
4/07
Rab
L�
REVISED DRIVEWAYS FOR COMMERICAL CENTER
8/05
RG
CHECKED BY:3517
'�,� MCH
ED
RICA DO SANDOVAL R.C.E. 51152 DATE:
DRAWING N0.2
ADDITIONAL DRIVEWAYS FOR COMMERICAL CENTER.
3/05
1
RELOCATED STREET LIGHT
9/04
MATT EW C. HICKS RCE N0. 63494 EXP. 09-30-06