HomeMy WebLinkAbout3501-2INSTALL 6PR#19 SIGNAL
INTERCONNECT CABLE. CONNECT
ROANOKE ROAD INTERCONNECT PER TRAFFIC SIGNAL
1 2-T CONTROLLER MANUFACTURER'S
REQUIREMENTS.
CHERRY "ENUE
1-� F�
- EX. R W — — — - — — N D- — — — — (n — — EX. R/--- - __
-- — --_ - - - - - -
rl
0vv_ v vv vv 7C-- -- -- -- -- 0 0
S N �
Q w _ - - - EX. 2 C. WITH SIC
< __s --- S --- SID -- s --- SD --- s --- SD --- SID --- SD
--- s® --- SD -- SD---- SD--- SLS--- SD --- � Q J - T
T
O = 00 5+00 MEDIAN – – 36+00 – – 37+00 – 38+00 __13+00 40+00 41+00 42 V) - F -
_ _ _ _ _ _ _ MEDIAN
w (n s--r� s -- __ -- --- �- - -s---- - - -- I s-- -r— s - -- s-- -- s - W _ _ �_ _ _ �- r
L J
m - - -- -- LLJ
EX. C G
W -
U S U w
~ cn
W-- V_ W UN- W-- Vit-- W Nim w_ Q G._-_
Q -- -
�C. , o u2
EX. R/W — — — — — — — — — — — — — — — — — — — — — — — — —F� n
TRAFFIC SIGNAL INTERCONNECT GENERAL NOTES
1. TRAFFIC SIGNAL INTERCONNECT SHALL CONFORM TO THESE PLANS, THE STATE OF
CALIFORNIA STANDARD SPECIFICATIONS SECTION 86 AND STANDARD PLANS (DATED
JULY 2002).
2. LOCATION OF ALL UNDERGROUND FACILITITES ARE APPROXIMATE. THE CONTRACTOR
SHALL POTHOLE TO DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS ON
THE JOB SITE. HAND DIG UNTIL CLEAR OF OBSTRUCTIONS. PHONE UNDERGROUND
SERVICE ALERT AT (800) 227-2600, TWO (2) WORKING DAYS BEFORE DIGGING.
3. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER FOR EXACT EQUIPMENT
LOCATIONS PRIOR TO FINAL PLACEMENT.
4. ALL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF
FONTANA ENGINEERING DIVISION PRIOR TO COMMENCENT OF WORK.
5. ALL TRAFFIC CONTROL, WORK ZONES, AND LANE CLOSURES SHALL BE COMPLETELY
DELINEATED BY CHANNELIZATION DEVICES AND SHIELDED BY BARRIERS TO EXCLUDE
VEHICLE AND/OR PEDESTRIAN TRAFFIC. CONTRACTOR SHALL FOLLOW THE MANUAL OF
TRAFFIC CONTROL DEVICES FOR CONSTRUCTION AND MAINTENANCE WORK ZONES,
CALTRANS STANDARD SPECIFICATIONS, AND STANDARD PLANS, THE LATEST EDITION.
EXACT LOCATION OF ALL TRAFFIC CONTROL TO BE DETERMINED BY THE ENGINEER AND
ADDITIONAL WARNING AND/OR CONSTRUCTION SIGNING MAY BE REQUIRED.
6. ALL PULLBOXES SHALL BE No. 6 AND CONDUIT SHALL BE 2" RIGID METAL UNLESS
OTHERWISE SHOWN. ALL INTERCONNECT PULLBOXES SHALL BE TYPE P48
48.5%30.5%30" DEEP (INSIDE), PRE -CAST CONCRETE, HAVE LOCKING LIDS, AND BE
LABELED "COMMUNICATIONS".
C.
EXISTING CURB
AND/OR
CURB AND GUTTER
NEW A.C.
TACK COAT
ALL EDGES
1 0
N +
N CHERRY
d – <00
Q co
EX. R W
EX. R/W – (n d – – – —� – – —
\C – – –
IV -- _ - -- -- T --
O - -- E ' TV Ex. c/c
O - - - - - - - -- _----------------
n I _
Xvv
r-�/ti- V Y V r r Y Y`/ (� �/ /"� (� }/ V (� 1/ %� (` 'moi
I- V G V- V - U V--- V-- -- - V VV `.'V-
d- O
-- Sp --- SD D Xs_ --- S --- s -Q--- s -- D --- SD --- SD --- SD --- SID � � 2" C. slc
(n � 00 MEDIAN – 43+00 – 44+00 – 45 t -00--s 461 GO 4:7100
_8+OQ 49+00 504
W O -- S---- I s -- -T— S
z m
–1 Q
S w
F_ W
cn W-E -x -/� W-- w_ Nit— Vim— W _ VW— V� _ \� ViL VN
EX. C/G
EX. R/W–
I+ EX. R/W
BAR HARBOR ROAD
HEADER
CUT
--- --
(----------------
mom
EXISTING
0.10' MIN. AC SURFACING
4 -SACK ORANGE
PEA GRAVEL BACKFILL
(INITIAL POUR TO BE FLUSH
WITH SURROUNDING SURFACE)
INSTALL SIX 1.5" SCH. 40 HDPE CONDUITS
DUCT/CONDUIT INSTALLATION AND TRENCH REPAIR DETAIL
N.T.S.
DETAIL WO
TRAFFIC SIGNAL INTERCONNECT CONSTRUCTIO14 NOTES
FURNISH AND INSTALL 6-1.5" SCHEDULE 40 HDPE CONDUITS PER DETAIL "A." THE
CONDUITS SHALL BE COLOR CODED ORANGE, YELLOW, RED, BLACK, BLUE, AND GREEN.
FURNISH AND INSTALL ONE (1) INTERCONNECT CABLE (6PR#19) IN THE ORANGE
CONDUIT. FURNISH AND INSTALL 1/4" POLY PULL ROPE IN THE REMAINING CONDUITS
FOR FUTURE CABLE. CONDUIT SWEEPS SHALL BE INSTALLED WITH A MINIMUM
w�
JD -FOOT RADIUS.
FURNISH AND INSTALL 2" C., WITH 6PR#19 SIGNAL INTERCONNECT CABLE. CONNECT INTERCONNECT
PER TRAFFIC SIGNAL CONTROLLER MANUFACTURER'S REQUIREMENTS.
40 20 0 40 80 120
S: \traffic\Reggie\Plans\Cherry Signal s\Cherry_Meyer Cyn to Bar Barbor SIC.dwg