HomeMy WebLinkAbout3501-1I 0 C H rz R RY + Q F- V) -w w MEYER CANYON DRIVE 1. IRAFFIC SIGNAL INTERCONNECT SHALL CONFORM TO THESE PLANS, THE STATE OF CALIFORNIA STANDARD SPECIFICATIONS SECTION 86 AND STANDARD PLANS (DATED JULY 2002). 2. LOCATION OF ALL UNDERGROUND FACILITITES ARE APPROXIMATE. THE CONTRACTOR SHALL POTHOLE TO DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS -ON THE JOB SITE. HAND DIG UNTIL CLEAR OF OBSTRUCTIONS. PHONE UNDERGROUND SERVICE ALERT AT (800) 227-2600, TWO (2) WORKING DAYS BEFORE DIGGING. 3. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER FOR EXACT EQUIPMENT LOCATIONS PRIOR TO FINAL PLACEMENT. 4. ALL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA ENGINEERING DIVISION PRIOR TO COMMENCENT OF WORK. 5. ALL TRAFFIC CONTROL, WORK ZONES, AND LANE CLOSURES SHALL BE COMPLETELY DELINEATED BY CHANNELIZATION DEVICES AND SHIELDED BY BARRIERS TO EXCLUDE VEHICLE AND/OR PEDESTRIAN TRAFFIC. CONTRACTOR SHALL FOLLOW THE MANUAL OF TRAFFIC CONTROL DEVICES FOR CONSTRUCTION AND MAINTENANCE WORK ZONES, CALTRANS STANDARD SPECIFICATIONS, AND STANDARD PLANS, THE LATEST EDITION. EXACT LOCATION OF ALL TRAFFIC CONTROL TO BE DETERMINED BY THE ENGINEER AND ADDITIONAL WARNING AND/OR CONSTRUCTION SIGNING MAY BE REQUIRED. 6. ALL PULLBOXES SHALL BE No. 6 AND CONDUIT SHALL BE 2" RIGID METAL UNLESS OTHERWISE SHOWN. ALL INTERCONNECT PULLBOXES SHALL BE TYPE P48 48.5"x30.5"x30" DEEP (INSIDE), PRE -CAST CONCRETE, HAVE LOCKING LIDS, AND BE LABELED "COMMUNICATIONS 2 SEE CHERRY AVENUE AND MEYER CANYON DRIVE TRAFFIC SIGNAL INSTALLATION PLAN DWG. NO 3495 r.. ���� AVENUEMILLER SEE CHERRY AVENUE AND MILLER AVENUE TRAFFIC SIGNAL INSTALLATION PLAN DWG. NO 3496 CONDUITS SHALL BE COLOR CODED ORANGE, YELLOW, RED, BLACK, BLUE, AND GREEN. -� FURNISH AND INSTALL ONE (1) INTERCONNECT CABLE (6PR#19) IN THE ORANGE CONDUIT. FURNISH AND INSTALL 1/4" POLY PULL ROPE IN THE REMAINING CONDUITS FOR FUTURE CABLE. CONDUIT SWEEPS SHALL BE INSTALLED WITH A MINIMUM 10 -FOOT RADIUS. FURNISH AND INSTALL 2" C., WITH 6PR#19 SIGNAL INTERCONNECT CABLE. CONNECT INTERCONNECT PER TRAFFIC SIGNAL CONTROLLER MANUFACTURER'S REQUIREMENTS. EXISTING CURB AND/OR CURB AND GUTTER NEW A.C. TACK COAT ALL EDGES EDISON AVENUE HEADER CUT ----- -- ------ -- - EXISTING -0.10' MIN. AC SURFACING 4 -SACK ORANGE PEA GRAVEL BACKFILL (INITIAL POUR TO BE FLUSH WITH SURROUNDING SURFACE) INSTALL SIX 1.5" SCH. 40 HDPE CONDUITS DUCT/CONDUIT INSTALLATION A , D TRENCH REPAIR DETAIL N.T.S. DETAIL "A" Q 1 J Q, U O O O N ct Q 23 C/-) 0 -- w _j z w m = w J 0 Q Q U Q 0 Q Z Q Q Q 0 U W Imo. Q ct Z U S: \traffic\Reggie\Plans\Cherry Sign als\Ch erry—Meyer Cyn to Bar Barbor SIC.dwg