GENERAL NOTES:
TRAFFIC SIGNAL, SIGNING AND STRIPING, AND LIGHTING SHALL CONFORM TO THESE
PLANS, THE SPECIAL PROVISIONS, THE CITY OF FONTANA STANDARD DETAILS, AND THE
STATE OF CALIFORNIA STANDARD SPECIFICATIONS SECTION 86 AND STANDARD PLANS
(DATE JULY 2002).
LOCATION OF ALL UNDERGROUND FACILITIES ARE APPROXIMATE. THE CONTRACTOR
SHALL POTHOLE TO DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS ON
THE JOB SITE. HAND DIG FOUNDATINS UNTIL CLEAR OF ANY OBSTRUCTIONS. PHONE
UNDERGROUND SERVICE ALERT AT (800) 227-2600, TWO (2) WORKING DAYS BEFORE
DIGGING.
ALL PULLBOXES SHALL BE No. 6 AND CONDUIT SHALL BE 2" RIGID METAL UNLESS
OTHERWISE SHOWN.
CONTRACTOR SHALL MAKE APPLICATION FOR ELECTRIC SERVICE AND SCHEDULING WITH
SOUTHERN CALIFORNIA EDISON COMPANY WELL IN ADVANCE OF NEED.
CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER FOR EXACT EQUIPMENT
LOCATIONS PRIOR TO FINAL PLACEMENT. SEE ES -4C FOR POLE LOCATION DETAIL.
ALL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF
FONTANA ENGINEERING DIVISION PRIOR TO COMMENCEMENT OF WORK.
CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS, AND
SIDEWALK AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE ENGINEER.
CONTROLLER CABINET SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS.
MODIFY SPRINKERS SYSTEMS IF NECESSARY.
CRERov
Ex R/W
GENERAL NOTES (CONT.):
THE ALIGNMENT OF INTERCONNECT DUCTS SHALL BE AS STRAIGHT AS POSSIBLE.
HOWEVER, WHEN CHANGES IN ALIGNMENT ARE NECESSARY, SWEEPS SHALL HAVE
MINIMUM RADIUS OF 10 FEET.
ALL VEHICLE INDICATIONS SHALL BE 12" AND HAVE L.E.D. SIGNAL MODULES. ALL
PEDESTRIAN HEADS SHALL HAVE L.E.D. PEDESTRIAN MODULES.
ANY EXISTING TRAFFIC SIGNALS AND LIGHTING SHALL REMAIN IN OPERATION UNTIL
REPLACED WITH NEW CONSTRUCTION.
CONTRACTOR TO FURNISH ALL EQUIPMENT, MATERIALS, AND HARDWARE TO CONSTRUCT
THE TRAFFIC SIGNAL AND LIGHTING AS SHOWN ON THE PLANS, EXCEPT AS NOTED CITY
FURNISHED OR LISTED AS CITY PROVIDED IN THE SPECIAL PROVISIONS.
CONTRACTOR SHALL REFER TO THE CITY TRAFFIC ENGINEER IN THE EVENT OF A
CONFLICT OR POTENTIAL CONFLICT WITH THESE PLANS AND, OR SPECIFICATIONS FOR
THIS PROJECT.
WHERE TRAFFIC SIGNAL STREET CROSSING CONDUIT ARE NOT INSTALLED USING THE
BORING METHOD, TRENCH REPAIRS SHALL BE PER DETAIL ON THIS SHEET, AND SPECIAL
PROVISIONS, SECTION E.
TRAFFIC SIGN DIMENSIONS, COLOR, AND LETTERING SHALL CONFORM TO THE LATEST
CALTRANS SIGN SPECIFICATIONS SHEETS. SIGN CODES SHOWN HEREON ARE TO
CONFORM TO CALTRANS SPECIFICATION SHEET CODES. TRAFFIC SIGN SIZE SHALL BE
STANDARD UNLESS OTHERWISE SHOWN ON THE PLANS.
♦ CONDUCTOR
DIAGRAM
NOT
USED
TABLE
NOT
USED
NOT
USED
PHASE 1
AWG.
CIRCUIT OR
PHASE 4
NOT
USED
STANDARD
NOT
USED
RUNS
PHASE 5
PHASE 61
PHASE 71
PHASE 8
POLE
1
2
3
4
5 6Li
7
8
9
m
POLE10
1/0
1/0
1/0
1/0
1—A
10
U
POLE
0
0
POLE
0
o
POLELr
`r
POLE
C)
POLE 60
1/0
1/0
1/0
1/0 1/0
TOTAL
1/0
2/1
3/2
3/2
3/2
3/2
3/2
2/1 1/0
10
ILUMINAIRE
2
1 2
2
1
2
1 2
2
VIDEO
VIDEO CABLE
1
2
3
3
3
DET.
OPTICOM CABLE
11
1 1 3
3
CONDUIT SIZE
1 2"
3"
3"
1 3"
1 3" 1 3"
3"
3"
1 3" 2"
- ALL CONDUIT AND CONDUCTORS ARE NEW.
Z - RUN #9 TO BE INSTALLED USING BORING METHOD ONLY.
BARRIER
PHASE
DIAGRAM
NOT
USED
—�-
-.0-A
NOT
USED
NOT
USED
PHASE 1
PHASE 2
PHASE 3
PHASE 4
NOT
USED
STANDARD
NOT
USED
i
PHASE 5
PHASE 61
PHASE 71
PHASE 8
I
u
MAST—ARM MOUNTING
CLAMP FOR OPTICAL DETECTOR
o POLE SCHEDULE * AS DIMENSIONED ON PLAN
MASTARMS
LUMINAIRE
PED PUSH BT.
SIGNAL MOUNTING
S.N.S.
PLACEMENT
REMARKS
0
C
STANDARD
TYPE
HT.
SIG.
30
20'
25
—
—
-
LUM.
15
15
15
—
15
-
H.P.S.V.
250W
250W
250W
—
250W
-
TYPE
—
B
B
B
B
-
PHASE
—
8
8
2
2
-
QUAD
—
N
S
W
W
-
MASTARM
MAS
MAS
MAS
—
—
-
POLE
SV -2—T
SV -2—T
SV - 1-T
—
—
,TV,A2—T,'
PED.
—
SP-1—CS
SP-1—CS
Tp -1
—
SP 1KICSIw
MESSAGE
Fox Ride Dr
Cherry Ave
Fox Rid e Dr
—
—
AIC-eQ-cint
A
3'
2.5'
3'
3i rnNT
B
5'
4'
4'
4'
4'
A'rTOP
4,5,6
2,3,4,5,7
1 2 4 5 6
2
2,5
FIIRNISHFn S_N_S_ TO BE
'11
26A-4-80
17A-2-80
26A-4-80
1—A
TYPE 22
35
35
35
7
35
21
3
4
5
6
1—A
10
E ALL EQUIPMENT IS NEW.
LEGEND:
►� - IMAGE SENSOR UNIT.
DEER DRIVE -*-0 -OPTICAL DETECTOR.
Curb/Berm flow line
or edge of shoulder
DETAIL "A"
VEHICLE HEAD 17' ABOVE BASE.
2. INSTALL 2" ADA PED PUSH BUTTON.
3. ROTATE LUMINAIRE MAST ARM BUTT PLATE
90 DEGREES.
(@ - ADVANCE VIDEO DETECTION ZONE.
INSTALL 2" C.,
WITH 2#6 (SIG.)
INSTALL 2" C.,
'WITH 2#10 (LUM.)
INSTALL BY BORING
METHOD ONLY.
EXISTING
DECORATIVE
PAVEMENT
FOX RIDGE DR.
0%0%ud_-Ere1 1I+T1/1V ur%9rcC■
EDISON SERVICE
FEED POINT
(HAND HOLE)
NOTE: SEE SPECIAL PROVISIONS FOR ANY CITY SUPPLIED EQUIPMENT AND/OR MATERIALS.
aINSTALL CITY FURNISHED TYPE 90 CONTROLLER EQUIPMENT PACKAGE INCLUDING TYPE "R" CABINET,
SOLO PRO VIDEO DETECTION, BATTERY BACKUP, AND APPURTENANT EQUIPMENT. CONTROLLER CABINET
AND FOUNDATION SHALL BE INSTALLED PER CITY STANDARD DRAWING 4004. CONTRACTOR SHALL
FURNISH AND INSTALL ANY ADDITIONAL ELECTRONIC EQUIPMENT REQUIRED TO PROVIDE THE SIGNAL
OPERATION AS SHOWN ON THE PLAN.
aINSTALL TYPE III -BF SERVICE EQUIPMENT ENCLOSURE PER CITY OF FONTANA AND SOUTHERN CALIFORNIA
EDISON COMPANY REQUIREMENTS.
❑3 FURNISH AND INSTALL 3" PVC CONDUIT WITH 1/4" POLY PULL ROPE PER SCE REQUIREMENTS.
COORDINATE SERVICE WITH SCE (DAVID QUEZADA 909-357-6240 AND CANERA MILES 909-357-6505).
4A INSTALL CITY FURNISHED IMAGE SENSOR UNIT AS DIRECTED BY THE ENGINEER.
INSTALLED ON A SHAFT MOUNTED MAST
ARM SUPPLIED BY THE CITY. ARM TO BE
INSTALLED AT 24' ABOVE BASE.
5. INSTALL LUMINAIRE CUTOFF SHIELD.
6. MODIFY SIGNAL MASTARM BUTT PLATE TO Q
FIT STANDARD TYPE 26A POLE MOUNTING. J
7. MODIFY SIGNAL MASTARM BUTT PLATE TO Q,
FIT STANDARD TYPE 19A POLE MOUNTING.
0
J
XWALK �
S J
0
_
_
_
Q
EXCG
Ps
'E9 \
R81
C.B.
CONSTRUCTION NOTES (CONT.):
NOTE: SEE SPECIAL PROVISIONS FOR ANY CITY SUPPLIED EQUIPMENT AND/OR MATERIALS.
4B INSTALL CITY FURNISHED IMAGE SENSOR UNIT USING "J" BRACKETS AS DIRECTED BY THE ENGINEER.
aINSTALL CITY FURNISHED UNI -DIRECTIONAL, SINGLE CHANNEL OPTICOM DETECTOR (MODEL 711 OR EQUAL)
PER DETAIL ON THIS SHEET Olt . AS DIRECTED BY THE ENGINEER.
E REMOVE STREET DECORATIVE STREET LIGHT (BY EDISoM).
❑7 TRIM TREES TO PROVIDE SIGNAL HEAD VISIBILITY.
88 INSTALL R96, R96A, AND R96B SIGNS BACK TO BACK.
6-1.5" SCHEDULE 40 HDPE CONDUITS WITH ONE (1) INTERCONNECT CABLE (6PR#19) IN THE ORANGE
CONDUIT. SEE SIGNAL INTERCONNECT PLAN FOR INSTALLATION.
10 CONSTRUCT 4" THICK PCC PAD ON 90% COMPACTED NATIVE.
11 2" CONDUIT WITH 6PR#19 SIGNAL INTERCONNECT CABLE. SEE SIGNAL INTERCONNECT PLAN FOR
INSTALLATION.
S:\traffic\Reggie\Plans\Cherry Sig nals\Cherry-FoxRidge TS.dwg
Q
Q
Q)
4-
Q
Q