Loading...
HomeMy WebLinkAbout3497-13. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. GENERAL NOTES: TRAFFIC SIGNAL, SIGNING AND STRIPING, AND LIGHTING SHALL CONFORM TO THESE PLANS, THE SPECIAL PROVISIONS, THE CITY OF FONTANA STANDARD DETAILS, AND THE STATE OF CALIFORNIA STANDARD SPECIFICATIONS SECTION 86 AND STANDARD PLANS (DATE JULY 2002). LOCATION OF ALL UNDERGROUND FACILITIES ARE APPROXIMATE. THE CONTRACTOR SHALL POTHOLE TO DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS ON THE JOB SITE. HAND DIG FOUNDATINS UNTIL CLEAR OF ANY OBSTRUCTIONS. PHONE UNDERGROUND SERVICE ALERT AT (800) 227-2600, TWO (2) WORKING DAYS BEFORE DIGGING. ALL PULLBOXES SHALL BE No. 6 AND CONDUIT SHALL BE 2" RIGID METAL UNLESS OTHERWISE SHOWN. CONTRACTOR SHALL MAKE APPLICATION FOR ELECTRIC SERVICE AND SCHEDULING WITH SOUTHERN CALIFORNIA EDISON COMPANY WELL IN ADVANCE OF NEED. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER FOR EXACT EQUIPMENT LOCATIONS PRIOR TO FINAL PLACEMENT. SEE ES -4C FOR POLE LOCATION DETAIL. ALL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA ENGINEERING DIVISION PRIOR TO COMMENCEMENT OF WORK. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS, AND SIDEWALK AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE ENGINEER. CONTROLLER CABINET SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS. MODIFY SPRINKERS SYSTEMS IF NECESSARY. CRERov Ex R/W GENERAL NOTES (CONT.): THE ALIGNMENT OF INTERCONNECT DUCTS SHALL BE AS STRAIGHT AS POSSIBLE. HOWEVER, WHEN CHANGES IN ALIGNMENT ARE NECESSARY, SWEEPS SHALL HAVE MINIMUM RADIUS OF 10 FEET. ALL VEHICLE INDICATIONS SHALL BE 12" AND HAVE L.E.D. SIGNAL MODULES. ALL PEDESTRIAN HEADS SHALL HAVE L.E.D. PEDESTRIAN MODULES. ANY EXISTING TRAFFIC SIGNALS AND LIGHTING SHALL REMAIN IN OPERATION UNTIL REPLACED WITH NEW CONSTRUCTION. CONTRACTOR TO FURNISH ALL EQUIPMENT, MATERIALS, AND HARDWARE TO CONSTRUCT THE TRAFFIC SIGNAL AND LIGHTING AS SHOWN ON THE PLANS, EXCEPT AS NOTED CITY FURNISHED OR LISTED AS CITY PROVIDED IN THE SPECIAL PROVISIONS. CONTRACTOR SHALL REFER TO THE CITY TRAFFIC ENGINEER IN THE EVENT OF A CONFLICT OR POTENTIAL CONFLICT WITH THESE PLANS AND, OR SPECIFICATIONS FOR THIS PROJECT. WHERE TRAFFIC SIGNAL STREET CROSSING CONDUIT ARE NOT INSTALLED USING THE BORING METHOD, TRENCH REPAIRS SHALL BE PER DETAIL ON THIS SHEET, AND SPECIAL PROVISIONS, SECTION E. TRAFFIC SIGN DIMENSIONS, COLOR, AND LETTERING SHALL CONFORM TO THE LATEST CALTRANS SIGN SPECIFICATIONS SHEETS. SIGN CODES SHOWN HEREON ARE TO CONFORM TO CALTRANS SPECIFICATION SHEET CODES. TRAFFIC SIGN SIZE SHALL BE STANDARD UNLESS OTHERWISE SHOWN ON THE PLANS. ♦ CONDUCTOR DIAGRAM NOT USED TABLE NOT USED NOT USED PHASE 1 AWG. CIRCUIT OR PHASE 4 NOT USED STANDARD NOT USED RUNS PHASE 5 PHASE 61 PHASE 71 PHASE 8 POLE 1 2 3 4 5 6Li 7 8 9 m POLE10 1/0 1/0 1/0 1/0 1—A 10 U POLE 0 0 POLE 0 o POLELr `r POLE C) POLE 60 1/0 1/0 1/0 1/0 1/0 TOTAL 1/0 2/1 3/2 3/2 3/2 3/2 3/2 2/1 1/0 10 ILUMINAIRE 2 1 2 2 1 2 1 2 2 VIDEO VIDEO CABLE 1 2 3 3 3 DET. OPTICOM CABLE 11 1 1 3 3 CONDUIT SIZE 1 2" 3" 3" 1 3" 1 3" 1 3" 3" 3" 1 3" 2" - ALL CONDUIT AND CONDUCTORS ARE NEW. Z - RUN #9 TO BE INSTALLED USING BORING METHOD ONLY. BARRIER PHASE DIAGRAM NOT USED —�- -.0-A NOT USED NOT USED PHASE 1 PHASE 2 PHASE 3 PHASE 4 NOT USED STANDARD NOT USED i PHASE 5 PHASE 61 PHASE 71 PHASE 8 I u MAST—ARM MOUNTING CLAMP FOR OPTICAL DETECTOR o POLE SCHEDULE * AS DIMENSIONED ON PLAN MASTARMS LUMINAIRE PED PUSH BT. SIGNAL MOUNTING S.N.S. PLACEMENT REMARKS 0 C STANDARD TYPE HT. SIG. 30 20' 25 — — - LUM. 15 15 15 — 15 - H.P.S.V. 250W 250W 250W — 250W - TYPE — B B B B - PHASE — 8 8 2 2 - QUAD — N S W W - MASTARM MAS MAS MAS — — - POLE SV -2—T SV -2—T SV - 1-T — — ,TV,A2—T,' PED. — SP-1—CS SP-1—CS Tp -1 — SP 1KICSIw MESSAGE Fox Ride Dr Cherry Ave Fox Rid e Dr — — AIC-eQ-cint A 3' 2.5' 3' 3i rnNT B 5' 4' 4' 4' 4' A'rTOP 4,5,6 2,3,4,5,7 1 2 4 5 6 2 2,5 FIIRNISHFn S_N_S_ TO BE '11 26A-4-80 17A-2-80 26A-4-80 1—A TYPE 22 35 35 35 7 35 21 3 4 5 6 1—A 10 E ALL EQUIPMENT IS NEW. LEGEND: ►� - IMAGE SENSOR UNIT. DEER DRIVE -*-0 -OPTICAL DETECTOR. Curb/Berm flow line or edge of shoulder DETAIL "A" VEHICLE HEAD 17' ABOVE BASE. 2. INSTALL 2" ADA PED PUSH BUTTON. 3. ROTATE LUMINAIRE MAST ARM BUTT PLATE 90 DEGREES. (@ - ADVANCE VIDEO DETECTION ZONE. INSTALL 2" C., WITH 2#6 (SIG.) INSTALL 2" C., 'WITH 2#10 (LUM.) INSTALL BY BORING METHOD ONLY. EXISTING DECORATIVE PAVEMENT FOX RIDGE DR. 0%0%ud_-Ere1 1I+T1/1V ur%9rcC■ EDISON SERVICE FEED POINT (HAND HOLE) NOTE: SEE SPECIAL PROVISIONS FOR ANY CITY SUPPLIED EQUIPMENT AND/OR MATERIALS. aINSTALL CITY FURNISHED TYPE 90 CONTROLLER EQUIPMENT PACKAGE INCLUDING TYPE "R" CABINET, SOLO PRO VIDEO DETECTION, BATTERY BACKUP, AND APPURTENANT EQUIPMENT. CONTROLLER CABINET AND FOUNDATION SHALL BE INSTALLED PER CITY STANDARD DRAWING 4004. CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL ELECTRONIC EQUIPMENT REQUIRED TO PROVIDE THE SIGNAL OPERATION AS SHOWN ON THE PLAN. aINSTALL TYPE III -BF SERVICE EQUIPMENT ENCLOSURE PER CITY OF FONTANA AND SOUTHERN CALIFORNIA EDISON COMPANY REQUIREMENTS. ❑3 FURNISH AND INSTALL 3" PVC CONDUIT WITH 1/4" POLY PULL ROPE PER SCE REQUIREMENTS. COORDINATE SERVICE WITH SCE (DAVID QUEZADA 909-357-6240 AND CANERA MILES 909-357-6505). 4A INSTALL CITY FURNISHED IMAGE SENSOR UNIT AS DIRECTED BY THE ENGINEER. INSTALLED ON A SHAFT MOUNTED MAST ARM SUPPLIED BY THE CITY. ARM TO BE INSTALLED AT 24' ABOVE BASE. 5. INSTALL LUMINAIRE CUTOFF SHIELD. 6. MODIFY SIGNAL MASTARM BUTT PLATE TO Q FIT STANDARD TYPE 26A POLE MOUNTING. J 7. MODIFY SIGNAL MASTARM BUTT PLATE TO Q, FIT STANDARD TYPE 19A POLE MOUNTING. 0 J XWALK � S J 0 _ _ _ Q EXCG Ps 'E9 \ R81 C.B. CONSTRUCTION NOTES (CONT.): NOTE: SEE SPECIAL PROVISIONS FOR ANY CITY SUPPLIED EQUIPMENT AND/OR MATERIALS. 4B INSTALL CITY FURNISHED IMAGE SENSOR UNIT USING "J" BRACKETS AS DIRECTED BY THE ENGINEER. aINSTALL CITY FURNISHED UNI -DIRECTIONAL, SINGLE CHANNEL OPTICOM DETECTOR (MODEL 711 OR EQUAL) PER DETAIL ON THIS SHEET Olt . AS DIRECTED BY THE ENGINEER. E REMOVE STREET DECORATIVE STREET LIGHT (BY EDISoM). ❑7 TRIM TREES TO PROVIDE SIGNAL HEAD VISIBILITY. 88 INSTALL R96, R96A, AND R96B SIGNS BACK TO BACK. 6-1.5" SCHEDULE 40 HDPE CONDUITS WITH ONE (1) INTERCONNECT CABLE (6PR#19) IN THE ORANGE CONDUIT. SEE SIGNAL INTERCONNECT PLAN FOR INSTALLATION. 10 CONSTRUCT 4" THICK PCC PAD ON 90% COMPACTED NATIVE. 11 2" CONDUIT WITH 6PR#19 SIGNAL INTERCONNECT CABLE. SEE SIGNAL INTERCONNECT PLAN FOR INSTALLATION. S:\traffic\Reggie\Plans\Cherry Sig nals\Cherry-FoxRidge TS.dwg Q Q Q) 4- Q Q