HomeMy WebLinkAbout3495-1GENERAL NOTES: 1, TRAFFIC SIGNAL, SIGNING AND STRIPING, AND LIGHTING SHALL CONFORM TO THESE PLANS, THE SPECIAL PROVISIONS, THE CITY OF FONTANA STANDARD DETAILS, AND THE STATE OF CALIFORNIA STANDARD SPECIFICATIONS SECTION 86 AND STANDARD PLANS (DATE JULY 2002). 2. LOCATION OF ALL UNDERGROUND FACILITIES ARE APPROXIMATE. THE CONTRACTOR SHALL POTHOLE TO DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS ON THE JOB SITE. HAND DIG FOUNDATINS UNTIL CLEAR OF ANY OBSTRUCTIONS. PHONE UNDERGROUND SERVICE ALERT AT (800) 227-2600, TWO (2) WORKING DAYS BEFORE DIGGING. 3. ALL PULLBOXES SHALL BE No. 6 AND CONDUIT SHALL BE 2" RIGID METAL UNLESS OTHERWISE SHOWN. 4. CONTRACTOR SHALL MAKE APPLICATION FOR ELECTRIC SERVICE AND SCHEDULING WITH SOUTHERN CALIFORNIA EDISON COMPANY WELL IN ADVANCE OF NEED. 5. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER FOR EXACT EQUIPMENT LOCATIONS PRIOR TO FINAL PLACEMENT. SEE ES -4C FOR POLE LOCATION DETAIL. 6. ALL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA ENGINEERING DIVISION PRIOR TO COMMENCEMENT OF WORK. 7. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS, AND SIDEWALK AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE ENGINEER. 8. CONTROLLER CABINET SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS. MODIFY SPRINKERS SYSTEMS IF NECESSARY. MEYER CANYON 8 EDISON SERVICE 1 FEED POINT INSTALL 2" C., EX. R/W WITH 2 #6(SIG.). 0 IDA 27' 3 E - - F_- MAST -ARM MOUNTING CLAMP FOR OPTICAL DETECTOR BARRIER PHASE DIAGRAM STANDARD MASTARMS FUTURE _ M - PHASE 1 PHASE 2 PHASE 3 PHASE 4 REMARKS C TYPE FUTURE SIG. LUM. PHASE 5 PHASE 6 PHASE 7 PHASE 8 W Z W Q P48 STA 14+43 SEE SIC PLAN IX i EX. C/G ' 9 4 SD --- SD INSTALL 2" C., X334 11 WITH 4 #10(LUM.). 9 fIN 160' TO X -WALK W EX. C 11 � i i� d- 11 W R26( S I in EX. S/W EX. R/W GENERAL NOTES (CONT.): g_ THE ALIGNMENT OF INTERCONNECT DUCTS SHALL BE AS STRAIGHT AS POSSIBLE. HOWEVER, WHEN CHANGES IN ALIGNMENT ARE NECESSARY, SWEEPS SHALL HAVE MINIMUM RADIUS OF 10 FEET. 10. ALL VEHICLE INDICATIONS SHALL BE 12" AND HAVE L.E.D. SIGNAL MODULES. ALL PEDESTRIAN HEADS SHALL HAVE L.E.D. PEDESTRIAN MODULES. 11. ANY EXISTING TRAFFIC SIGNALS AND LIGHTING SHALL REMAIN IN OPERATION UNTIL REPLACED WITH NEW CONSTRUCTION. 12. CONTRACTOR TO FURNISH ALL EQUIPMENT, MATERIALS, AND HARDWARE TO CONSTRUCT THE TRAFFIC SIGNAL AND LIGHTING AS SHOWN ON THE PLANS, EXCEPT AS NOTED CITY FURNISHED OR LISTED AS CITY PROVIDED IN THE SPECIAL PROVISIONS. 13. CONTRACTOR SHALL REFER TO THE CITY TRAFFIC ENGINEER IN THE EVENT OF A CONFLICT OR POTENTIAL CONFLICT WITH THESE PLANS AND,OR SPECIFICATIONS FOR THIS PROJECT. 14. WHERE TRAFFIC SIGNAL STREET CROSSING CONDUIT ARE NOT INSTALLED USING THE BORING METHOD, TRENCH REPAIRS SHALL BE PER DETAIL ON THIS SHEET, AND SPECIAL PROVISIONS, SECTION E. 15. TRAFFIC SIGN DIMENSIONS, COLOR, AND LETTERING SHALL CONFORM TO THE LATEST CALTRANS SIGN SPECIFICATIONS SHEETS. SIGN CODES SHOWN HEREON ARE TO CONFORM TO CALTRANS SPECIFICATION SHEET CODES. TRAFFIC SIGN SIZE SHALL BE STANDARD UNLESS OTHERWISE SHOWN ON THE PLANS. O ON cc W V 08 IN- J 47' O Y J a LO N X I I t — L 120 7' S -t 18'/—5 [ 12' O "00 �O it ' 02 - -� 04 Spm I � 6 I 3�: 106 06 01 CD 12' 18' Y N Og 5 4J V V a (n O 1 IW 19, 6' 1 O O O (n + X W I P48 STA 11+60 SEE SIC PLAN 47 47 1 .0. T0 U U X � X w I I w O Y < LO N X (D I ®. 20 10 .0 20 40 60 4 0_ X w o POLE SCHEDULE o STANDARD MASTARMS LUMINAIRE PED PUSH BT. SIGNAL MOUNTING S.N.S. PLACEMENT REMARKS C TYPE HT. SIG. LUM. H.P.S.V. TYPE PHASE QUAD VEHICLE POLE PED. MESSAGE A B 8 1 1 A 10 — — — B 4 N — TV -1—T SP-1—CS — 25' 4' 1 2 26A-4-80 35' 30' 15' 250W B 2 W MAS SV -1—T SP-1—CS Cherry Ave 23' 6' 1, 2, 3 3 1A 10' — — — B 2 W — TV -1 SP-1—CS — 21 6' 1 4 29A-5-80 35 55 15 250W B 8 S MAS, MAS, MAS SV -1—T SP-1—CS Meyer Cyn Dr 24 4' 1, 3, F=18' 5 1A 10 — — — B 8 S — TV -1—T SP-1—CS — 8' 7' 1 6 26A-4-80 35' 25' 15' 250W B 6 E MAS SV -1—T SP-1—CS Cherry Ave 9' 7' 1, 2, 3 7 1A 10' — — — B 6 E — TV -1—T SP-1—CS — 9' 5.5' 1 8 29A-5-80 35 55' 15' 1 250W B 4 N MAS, MAS MAS SV -1—T SP-1—CS Meyer Cyn Dr 7' 1 10 1 1, 3, F=18' e ALL EQUIPMENT IS NEW. LEGEND: ►� - IMAGE SENSOR UNIT. �-� - UNI -DIRECTIONAL, SINGLE CHANNEL OPTICAL DETECTOR. - ADVANCE VIDEO DETECTION ZONE. 33 50' C.R. (BY OTHERS) E F I I R26(S) m W SD DRIVE EX. C/G w — 4- SD "f b U l X -WALK 1. INSTALL 2" ADA PED. PUSH BUTTON. AWG. 2. MODIFY SIGNAL MASTARM BUTT PLATE Q TO FIT STANDARD TYPE 26A POLE INSTALL CITY FURNISHED TYPE 90 CONTROLLER EQUIPMENT PACKAGE INCLUDING TYPE "R" CABINET, MOUNTING. 3. CONTRACTOR FURNISHED S.N.S. TO BE OSOLO 1 INSTALLED ON A SHAFT MOUNTED MAST AND FOUNDATION SHALL BE INSTALLED PER CITY STANDARD DRAWING 4004. CONTRACTOR SHALL ARM SUPPLIED BY THE CITY. ARM TO BE INSTALLED AT 24' ABOVE BASE. _Q POLE Q 2 J 4 5 6 Q 8 9 ♦ CONDUCTOR TABLE AWG. CIRCUIT OR RUNS El INSTALL CITY FURNISHED TYPE 90 CONTROLLER EQUIPMENT PACKAGE INCLUDING TYPE "R" CABINET, PRO VIDEO DETECTION, BATTERY BACKUP, AND APPURTENANT EQUIPMENT. CONTROLLER CABINET OSOLO 1 AND FOUNDATION SHALL BE INSTALLED PER CITY STANDARD DRAWING 4004. CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL ELECTRONIC EQUIPMENT REQUIRED TO PROVIDE THE SIGNAL OPERATION AS SHOWN ON THE PLAN. POLE 1 2 Al 4 5 6 7 8 9 1 JA F4] POLE ElINSTALL CITY FURNISHED UNI -DIRECTIONAL, SINGLE CHANNEL OPTICOM DETECTOR (MODEL 711 OR EQUAL) PER DETAIL ON THIS SHEET AND AS DIRECTED BY THE ENGINEER. E6-1.5" SCHEDULE 40 HDPE CONDUITS WITH ONE (1) INTERCONNECT CABLE (6PR#19) IN THE ORANGE CONDUIT. SEE SIGNAL INTERCONNECT PLAN FOR INSTALLATION. J ❑7 REMOVE STREET LIGHT POLE #4131419E (BY SCE). 8❑ 2" CONDUIT WITH 6PR#19 SIGNAL INTERCONNECT CABLE. SEE SIGNAL INTERCONNECT PLAN FOR INSTALLATION. g❑ CONSTRUCT 4" THICK PCC PAD ON 90% COMPACTED NATIVE. 10 M POLE 11 INSTALL SIGN ON MAST ARM. r o POLE 30 1/1 1/1 1/1 1/1 1/1 U z POLE POLE i N POLE O 1/1 1/1 Of O 0 POLE O7 1/1 1/1 1/1 0 oz POLE 80 1/1 1/1 1/1 1/1 '`j TOTAL 1/1 2/2 3/3 4/4 5/5 5/5 5/5 3/3 3/3 2/2 1/1 10 ILUMINAIRE 1 1 2 1 2 1 2 1 2 1 1 1 1 1 1 2 12 VIDEO DET. VIDEO CABLE 1 1 1 2 24 4 1 1 OPTICOM CABLE 1 1 2 2. 4 4 1 1 CONDUIT SIZE 1 2" 1 3" 1 3' 4' 1 4" 1 4" 1 4" 1 3" 4 1 3 2 - ALL CONDUIT AND CONDUCTORS ARE NEW. 50' C.R. EX. R/W 3 (BY OTHERS) O / Curb/Berm flow lir CONSTRUCTION NOTES: or edge of should( >A, NOTE: SEE SPECIAL PROVISIONS FOR ANY CITY SUPPLIED EQUIPMENT AND/OR MATERIALS. / El INSTALL CITY FURNISHED TYPE 90 CONTROLLER EQUIPMENT PACKAGE INCLUDING TYPE "R" CABINET, PRO VIDEO DETECTION, BATTERY BACKUP, AND APPURTENANT EQUIPMENT. CONTROLLER CABINET OSOLO 1 AND FOUNDATION SHALL BE INSTALLED PER CITY STANDARD DRAWING 4004. CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL ELECTRONIC EQUIPMENT REQUIRED TO PROVIDE THE SIGNAL OPERATION AS SHOWN ON THE PLAN. INSTALL TYPE III -BF SERVICE EQUIPMENT ENCLOSURE PER CITY OF FONTANA AND SOUTHERN CALIFORNIA 10 EDISON COMPANY REQUIREMENTS. F3] FURNISH AND INSTALL 3" PVC CONDUIT WITH 1/4" POLY PULL ROPE PER SCE REQUIREMENTS. COORDINATE SERVICE WITH SCE (DAVID QUEZADA 909-357-6240 AND CANERA MILES 909-357-6505). F4] INSTALL CITY FURNISHED IMAGE SENSOR UNIT AS DIRECTED BY THE ENGINEER. ElINSTALL CITY FURNISHED UNI -DIRECTIONAL, SINGLE CHANNEL OPTICOM DETECTOR (MODEL 711 OR EQUAL) PER DETAIL ON THIS SHEET AND AS DIRECTED BY THE ENGINEER. E6-1.5" SCHEDULE 40 HDPE CONDUITS WITH ONE (1) INTERCONNECT CABLE (6PR#19) IN THE ORANGE CONDUIT. SEE SIGNAL INTERCONNECT PLAN FOR INSTALLATION. ❑7 REMOVE STREET LIGHT POLE #4131419E (BY SCE). 8❑ 2" CONDUIT WITH 6PR#19 SIGNAL INTERCONNECT CABLE. SEE SIGNAL INTERCONNECT PLAN FOR INSTALLATION. g❑ CONSTRUCT 4" THICK PCC PAD ON 90% COMPACTED NATIVE. 10 REMOVE TREES BY OTHERS. 11 INSTALL SIGN ON MAST ARM. r Q r� vJ U 4- Q Q Q U Qt� U �I W W 0 Q I� Q TW z j S: \traffic\Reggie\Plans\Cherry Signal s\Cherry—M eyer Cyn TS.dwg