Loading...
HomeMy WebLinkAbout3493-1GENERAL SEWER NOTES: 1 ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUC77ON ("GREEN BOOK-). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS 07HERWISE NOTED. 2 WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE GREEN BOOK', THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO 774E CITY ENGINEER FOR RESOLUTION. 3 ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEERR, 4 CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVE- LOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO 7HE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 5 THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF 7RAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. 6 IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR 07HER TRAFFIC CONTROL DEVICES AT ALL TIMES. 7 THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEP7H FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. 8 THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF 7HE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT. 9 NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT-OF-WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE. 10 THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION. HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION. 11 THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES. 12 THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS 13 STATIONING REFERS TO THE CENTERLINE OF SEWER EXCEPT WHERE OTHERWISE NOTED. 14 ADEQUATE CONS7RUCTION CONTROL STAKES SHALL BE SET BY 774E ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONS7RUCTION. 15 THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICA77ON TO THE CITY ENGINEER. 16 REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT 77ES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT. 17 THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 18 THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES. 19 THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT-OF-WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL. 20 NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 21 A GEOTECHNICAL ENGINEER SHALL CER77FY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED. 22 CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS. 23 ALL EXPOSED CONCRETE SURFACES SHALL CONFORM /N GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE. 24 IF SEWER CONSTRUCTION IS TO BE DONE IN PHASES, THE CONTRACTOR SHALL PROVIDE A TERMINAL CLEANOUT AT THE PHASE BOUNDARY, NOT MORE THAN 150 FEET FROM THE DOWN STREAM MANHOLE, SEE CITY OF FONTANA STANDARD DETAIL FOR TERMINAL CLEANOUT. 25 SANITARY SEWER LINES SHALL BE CONSTRUCTED OF BELL AND SPIGOT OR BAND SEAL TYPE VITRIFIED CLAY PIPE (V.C.P.) EXTRA STRENG7H CLASS AND SHALL CONFORM TO THE PROVISIONS OF THE ASTM DESIGNA77ON C700 FOR V.C.P.. 26 NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE CITY ENGINEER. 27 SHORT VCP STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED AT MANHOLE WALLS TO ALLOW FOR MINOR DEFLECTIONS IN ALIGNMENT. 28 PRIOR TO CONSTRUCTION, 774E CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXIS77NG FACIL177ES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON 7HE PLANS 29 ALL 4" HOUSE LATERALS SHALL BE INSTALLED AT A 2% MINIMUM GRADE UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER. 30 TERMINATE ALL 4" HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH A PLUG 12" BELOW THE GROUND SURFACE. WHEN PUBLIC UTILITY EASEMENTS EXIST NEXT TO THE STREET RIGHT-OF-WAY, THE LATERAL SHALL TERMINATE 3 FEET INSIDE THE LOT AS MEASURED FROM THE UTILITY EASEMENT. 31 THE SEWER CONTRACTOR SHALL STAMP AN S" IN THE FACE OF THE CURB AT THE LOCATION OF THE SEWER LATERAL. 32 IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH 7HE PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY. 33 NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. 34 ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS. 35 APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT 36 ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING 37 UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER. 38 AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER. CITY OF FONTANA ON-SITE SEWER IMPROVEMENT ATTN: VIRGINIA BECKER PLANS 3939 E. CORONADO STREET FONTANA, CA 92335 TRACT (909) 350-6632 (714) 666-5467 SO. CALIFORNIA GAS COMPANY NO 16427-1 ATTN. GREG GASPAR ATTN. JACK HAYES & 16427-2 FONTANA, CA. 92335 ONTARIO, CA. 91761 W J Q U U) O F— O z CITY OF FONTANA UTILITY NOTIFICATION LIST CITY OF FONTANA PACIFIC BELL CO. ATTN. CARLOS NAVARRO ATTN: VIRGINIA BECKER 8353 SIERRA AVENUE 3939 E. CORONADO STREET FONTANA, CA 92335 ANAHEIM, CA 92807 (909) 350-6632 (714) 666-5467 SO. CALIFORNIA GAS COMPANY COMCAST (CABLE TV) ATTN. GREG GASPAR ATTN. JACK HAYES 16231 VALLEY BLVD. 1205 DUPONT AVENUE FONTANA, CA. 92335 ONTARIO, CA. 91761 E.V.C. (909) 390-4738 EMERGENCIES• (800) 427-2200 FLOW LINE FS. GENERAL TELEPHONE COMPANY SO. CALIFORNIA EDISON COMPANY ATTN: STEVE HOCK 7951 REDWOOD AVE. 1400 E. PHILLIPS BLVD. FONTANA, CA. 92335 ONTARIO, CA. 91766 (909) 820-5598 - UNDERGROUND (800) 422-4133 (909) 875-5100 - TRANSMISSIONS RIDGE UNE (213) 637-1233 - PIPELINES FONTANA WATER COMPANY (909) 357-6233 - DISTRIBUTION ATTN. MICHAEL J. McGRAW (800) 422-4133 8440 NUEVO AVENUE B.F. FONTANA, CA 92335 CRA WFORD CANYON MUTUAL WATER CO. (909) 822-2201 ATTN. BASIL J. FABRIZIO FAX. • (909) 823-5046 (909) 463-9580 PRIVATE ENGINEER'S NOTICE TO CONTRACTORS THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS; TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND RESPON- SIBILITY FOR THE UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN OR NOT SHOWN ON THESE DRAWINGS. THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONS- IBILITY FOR THE JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT; INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, THAT THIS SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL REPORT ALL DISCREPANCIES TO THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK. A.G. ASPHALTIC CONCRETE B.C. BEGIN CURVE B.V.C. BEG. VERTICAL CURVE B. W. BACK SIDEWALK C.B. CATCH BASIN C.L. CENTERLINE E. G END CURVE EP. EDGE PAVEMENT E.G. EDGE GRADE E.V.C. END VERTICAL CURVE F.L. FLOW LINE FS. FINISH SURFACE G.B. GRADE BREAK H.P. HIGH POINT IM! INVERT O.C. ON CENTER (R) RIDGE UNE RIW RIGHT OF WAY TAN. TANGENT T.C. TOP OF CURB B.F. BACK FLOW DEVISE f P.C.C. PORTLAND CEMENT CONCRETE W WIDTH V VERTICAL DEPTH (590.77) INDICATES EXISTING ELEVATION 590.77 INDICATES PROPOSED ELEVATION 90-100 INDICATES SLOPE 2:1 O AC PAVEMENT 0-15 REMOVAL 0-5 GRIND B EDGE OF PAVEMENT W WATER LINE W W ot SD STORM DRAIN RECO"'D 1 " S SEWER LINE MANHOLE - e r I Or`,!AT, N C0'4 '..En AND STREET LIGTH ' ? NOT BE FUa FH FIRE HYDRANT�"!`Y Er�_30R, QR OkVCSIONS WHICH r PF7 7I i 1017PCRATED INTO THE DOCUMENTS AS t r T P 7 7 TOLL FREE 1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT 3000 P.S.I. CONCRETE FONTANA HIGH SCHOOL #4 MALOOF AVENUE -GROUND SURFACE 1 95% COMPACTED BACKFILL 3" . 1 O. 4 BARS/-, 3 \P. SEWER MAIN Z 0 N Q • Q� a : w - -• • •. ISI o.. •a . . 11C -- .• II��L 6" MIN. NOTES: GRANUI AR BEDDINGS FROM SELECTED TRENCH SIDE MATERIAL TO BE USED FOR BACKFILL AND COMPACTED TO 95%. CONCRETE ENCASEMENT SHALL BE 3000 P.S.I. CONSRETE POURED AGAINST UNDISTURBED EARTH. aLENGTH OF CONCRETE ENCASEMENT PER PLAN. CONCRETE ENCASEMENT DETAIL N.T.S. REV. REVISION DESCRIP77ON DATE ENGR. CITY DATE SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT 1 'Sd r11 wu tfh t �n � REC.�IIJG. S TABLE: 200-1.2 A SIEVE SIZE PERCENTAGE PASSING SIEVE 1 1 2 - 1 L. F. 374— 100 la 90-100 8 20-60 NO. 4 0-15 NO. 8 0-5 ASTM C 131 TEST GRADING B SUMMIT AVE. CURTIS AVE. SIERRA LAKES PKWYY, VICINITY MAP NOT TO SCALE 6" MIN. 10" MAX. 3" MAX. SIZE— NATIVE SOIL COMPACTED 957. 6" MAX. SIZE— NATIVE SOIL COMPACTED 907. V.C.P. 10' OR DEEPER USE 1/2" CRUSHED STONE BEDDING PER STD. SPECS. FOR PUBLIC WORKS CONSTRUCTION TABLE 200 1.2 [A]. j Q W VARIES 6" MIN. I I 1 10" MAX. LU J Q U U) O F- F - 0 z 1 "MAX. SIZE SELECTED NATIVE BEDDING COMPACTED TO 907. _ � O a TYPICAL BEDDING DETAIL NOT TO SCALE CONSTRUCTION NOTES: QUANTITIES: CITY OF FONTANA, CALIFORNIA INSTALL 8" EXTRA STRENGTH V.C.P. SEWER. 5088 L. F. O2 - CONSTRUCT PRECAST CONCRETE MANHOLE PER CITY OF 21 Ea. RC 36637 EXP. 06- 0- 4 WENDELL L. IWATSURU FONTANA STD. DWG. NO. 112 (0=48"). Y.TRI 16427 _ Ea. FONTANA STD. DWG. NO. 112 (0=60'). O4 - X27. 3, 300 U CURTIS AVE. SIERRA LAKES PKWYY, VICINITY MAP NOT TO SCALE 6" MIN. 10" MAX. 3" MAX. SIZE— NATIVE SOIL COMPACTED 957. 6" MAX. SIZE— NATIVE SOIL COMPACTED 907. V.C.P. 10' OR DEEPER USE 1/2" CRUSHED STONE BEDDING PER STD. SPECS. FOR PUBLIC WORKS CONSTRUCTION TABLE 200 1.2 [A]. j Q W VARIES 6" MIN. I I 1 10" MAX. LU J Q U U) O F- F - 0 z 1 "MAX. SIZE SELECTED NATIVE BEDDING COMPACTED TO 907. _ � O a TYPICAL BEDDING DETAIL NOT TO SCALE BETIQH MARK' 8-17 BASS QF BEARINGS& CALTRANS BENCHMARK 8-17. A THE BASIS OF BEARINGS FOR THIS MAP '' No. YT3''{ BRASS CAP IN THE CONCRETE BASE OF IS THE CL LI,E CREEK RD. 663 7 a 1 \ F �. THE SOUTH LEG OF AN SCE TOWER SHOWN AS N00' 12 35 E ON REGiORD ,► ?i � 343' N0NORTH OF HIGHLAND 0.2 M/ WEST OF SURVEY MAP FILED IN OF SAN SEVAINE RD., 2.6� M/ WEST R.S.B. 111/99-103 OF SIERRA AVE EZEVA77OAp # 1428.609 1 1 9�R�� Fti oNo. 36637 a: rn Exp: 06-30-04 * � I C / V 1 \' TFOFCAL\FOS CONSTRUCTION NOTES: QUANTITIES: CITY OF FONTANA, CALIFORNIA INSTALL 8" EXTRA STRENGTH V.C.P. SEWER. 5088 L. F. O2 - CONSTRUCT PRECAST CONCRETE MANHOLE PER CITY OF 21 Ea. RC 36637 EXP. 06- 0- 4 WENDELL L. IWATSURU FONTANA STD. DWG. NO. 112 (0=48"). CONSTRUCT PRECAST CONCRETE MANHOLE PER CITY OF 1 Ea. FONTANA STD. DWG. NO. 112 (0=60'). O4 - INSTALL 4" V.C.P. SEWER LATERAL CITY OF FONTANA 3, 300 L.F. STD. DWG. NO. 125. 5� INSTALL BACKFLOW DEVICEE, 39 Ea. REMOVE PLUG, JOIN AT EXISTING SEWER. 1 Ea. CONSTRUCT CONCRETE ENCASEMENT PER DETAIL-kfEREON. 35 Ft. BETIQH MARK' 8-17 BASS QF BEARINGS& CALTRANS BENCHMARK 8-17. A THE BASIS OF BEARINGS FOR THIS MAP '' No. YT3''{ BRASS CAP IN THE CONCRETE BASE OF IS THE CL LI,E CREEK RD. 663 7 a 1 \ F �. THE SOUTH LEG OF AN SCE TOWER SHOWN AS N00' 12 35 E ON REGiORD ,► ?i � 343' N0NORTH OF HIGHLAND 0.2 M/ WEST OF SURVEY MAP FILED IN OF SAN SEVAINE RD., 2.6� M/ WEST R.S.B. 111/99-103 OF SIERRA AVE EZEVA77OAp # 1428.609 1 1 9�R�� Fti oNo. 36637 a: rn Exp: 06-30-04 * � I C / V 1 \' TFOFCAL\FOS Prepared Under The Supervision Of : ,N", "� iC 107 10601 CHURCH STREET , STE. 107 RANCHO CUC MONGA, CA 91730 PHONE (909) 948-1311 a.Date : Z CITY OF FONTANA, CALIFORNIA SEWER I MPR 0 VEMEN T PLANS DRAWN BY - Y TRACT NO. 16427-1 & 16427-2 KK DESIGNED 8K T TLE SHEET EF SCALE.• AS SHOWN DA 7E.- SEPT. 2003 CHECKED BY % APPROVED BY. !Z ' l `- U 3 Wl CITY ENGINEER R.C.E- 51152 DATE DRAWING NO.: 34 9 3 1 g RC 36637 EXP. 06- 0- 4 WENDELL L. IWATSURU N Z F.. V A N co C4 i J:\126-1751\TR16427-1\sewer\Sew0l.dm. 11/24/2003 10:58:51 AM. DM