HomeMy WebLinkAbout3475-1POLE SCHEDULd DIAGRAM STANDARD MASTARMS LUMINAIRE SIGNAL MOUNTING 3 PED PUSH BUTTON R.S.N.S. PLACEMENT REMARKS PHASE 3 TYPE HT. SIG. LUM. H.P.S.V. MAST ARM POLE PED. PHASE LOCATION MESSAGE A 8 2 Al29A-5-80 TRENCH EPAIR 35' 55 15' 250W MAS MAS MAS SV— 1—T SP -1—C 8 S Santa Ana Ave 22' 4' F1=18' F2=12' BA 1—A 10' — — — — TV— 1—T SP -1—C 2 W — 22' 4' 1 3" cl 24A-4-80 35' 35 15' 250W MAS SV— 1—T SP— 1 —Cl 2 1 W Cher Ave 22' 4' DI 1—A 10 — — — — TV— 1—T SP -1 -Cl 4 N — 22' 4' El 29A-5-80 35' 55' 15' 250W MAS MAS MAS SV -1-T SP- 1-C 4 N Santa Ana Ave 22' 4' F1=15 , F2=12 F 1—A 10 - — — — TV— 1—T SP— 1-C 6 E — 12. 4' G 24A-4-80 35' 35 15 250W MAS SV -1-T SP- 1-C 6 E Cherry Ave 22' 4' POLE H 1-A 10 - - - - TV- 1-T SP -1-C 8 S - 22' 4' 0 SEE TRAFFIC SIGNAL GENERAL NOTE #9. INSTALL R.S.N.S. ON POLE SHAFT. SHAFT MOUNTED MAST ARM TO BE CITY FURNISHED, SEE SPECIAL PROVISION. BARRIER PROPOSED PHASE DIAGRAM CIRCUIT OR RUNS NOT USED 2 3 i 5 6 PHASE 1 PHASE 2 PHASE 3 PHASE 4 1 1 NOT-.�— POLE o i USED 1 PHASE 5 PHASE 6 PHASE 7 PHASE 8 HEADER CUT TACK COAT COMPLETE SURFACE BEING PAVED DETAIL "A" N.T.S. SANTA ANA EP R/W R/W n "R" CABINET, SOLO PRO DETECTION AND AUXILIARY REQUIRED TO PROVIDE THE OPERATION SHOWN (SEE SPECIAL MAST -ARM MOUNTING PROVISIONS). CONTROLLER CABINET AND FOUNDATION TO BE INSTALLED PER CITY STANDARD EQUIPMENT DRAWING CLAMP FOR MODEL 711 OPTICAL DETECTOR 4004. CONNECT SIC PER TRAFFIC SIGNAL CONTROLLER MANUFACTURER'S REQUIREMENTS. DINSTALL TYPE III -BF SERVICE EQUIPMENT ENCLOSURE PER CITY OF FONTANA AND SOUTHERN CALIFORNIA DETAIL "B" EDISON COMPANY REQUIREMENTS (SEE SPECIAL PROVISIONS). LOCATE A SERVICE ENCLOSURE A MINIMUM OF 6' FROM CONTROLLER CABINET. ❑3 INSTALL MODEL 711 UNIDIRECTIONAL, SINGLE CHANNEL OPTICOM DETECTOR PER DETAIL "B", THIS SHEET, AND AS DIRECTED BY THE ENGINEER IN THE FIELD (SEE SPECIAL PROVISIONS). 4❑ INSTALL CITY FURNISHED IMAGE SENSOR UNIT PER CITY STANDARD DRAWING 133 AND AS DIRECTED BY THE ENGINEER IN THE FIELD. EINSTALL TYPE H SERVICE RISER, WITH PULLROPE PER SCE REQUIREMENTS. COORDINATE INSTALLATION WITH AN EDISON SERVICE PLANNER 48 HOURS PRIOR TO CONSTRUCTION. ❑6 INSTALL 2" CONDUIT, WITH 6 PAIR #19 SIC PER SPECIAL PROVISIONS. F7 INSTALL 6 - 1.5" SCHEDULE 40 HDPE CONDUITS PER DETAIL "D". THE CONDUITS SHALL BE COLOR CODED R/W- c & G I Q 6 -Q 66' O Z ! li 45 l m o r` z I N �I ., o j 18 12' �l $ 05 o� 0502 02 02. 02 &05 08 R73-2 8 4J 04 4 08 T --. 1 11 8 R34 INSTALL 2 3" AND 2-5" CO DUIT W/ PULLRO 014/FUTURE SCE. 7 CONDUIT I A BE STUBBED OUT AT BCR AN FSC 19 08 ITY OF FONTANA COUNT OF SAN BERNA DIN 1 04 R34 8 -- _.- _- 1 1 __-�. -_ 3 04 4 0801 6 8 J R73-2 04 F y"06 ~ 06 ✓ --- P 06 01 01 I R/W c& ORANGE, YELLOW, RED, ORANGE CONDUIT. NSTALBL�PULL BROPE N THELUE. AND REMAINING CONDUITS UNt FORFUO URE CABLNNtLI E. CONDU 01-11 If 1 SWEEPSHIN E COUNTY OF SAN BERNARDINO SHALL BE INSTALLED WITH A MINIMUM 10 -FOOT RADIUS. PUBLIC WORKS DEPARTMENT Q8 INSTALL SIGN NOTED AND HARDWARE MOUNTING ES -7N, DETAIL "U" PER CALTRANS STD. PLANS. "COUNTY JURISDICTION ONLY" ❑9 INSTALL P48 PULLBOX (48.5 L x 30.5 W x 30 D), PRE -CAST CONCRETE, HAVE LOCKING LIDS, AND BE LABELED "COMMUNICATIONS". INSTALL 3" PVC CONDUIT WITH 1/4" POLY PULL ROPE PER SCE REQUIREMENTS. COORDINATE SERVICE WITH SCE (GREG KLOCK AT (909) 357-6585). VERIFY PHONE NUMBERS AT TIME OF CONSTRUCTION. O 1 �' 111 INSTALL TENON. CAP FOR FUTURE USE. CHIEF TRAFFIC DIVISION DATE: REV. !11 w 45' 52' ' -�U SEE DRAWING NUMBER 3480, SHEET 2 OF 3 FOR MIDBLOCK DETAILS R/W IC & G CONDUCTOR SCHEDULE ''. L EXISTING CIRCUIT OR RUNS 0.10' MIN. AC SURFACING 2 3 NEW A.C. 5 6 2 -SACK 8 9 SLURRY MIX 1 1 (INITIAL POUR TO BE FLUSH POLE o WITH SURROUNDING SURFACE) 18 VIDEO SVC 1 RIGID METAL CONDUIT(S) 2 - 4 - 2 (INSTALLED WITH 18" MIN. COVER) 2 1 TRENCH EPAIR DETAIL "C" U N.T.S. to 'It TRAFFIC SIGNAL GENERAL NOTES:' 1. TRAFFIC SIGNAL AND LIGHTING SHALL CONFORM TO THESE PLANS, THE SPECIAL PROVISIONS, THE 1 1 2 1 2 CITY OF FONTANA STANDARD PLANS AND SPECIFICATIONS, AND THE STATE OF CALIFORNIA 2 1 2 STANDARD SPECIFICATIONS SECTION 86 AND STANDARD PLANS (DATED JULY 2002). _ 2. LOCATION OF ALL UNDERGROUND FACILITIES ARE APPROXIMATE. THE CONTRACTOR SHALL EP 3" 3" POTHOLE TO DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS ON THE JOB 1 4" 1 4" SITE. HAND DIG FOUNDATIONS UNTIL CLEAR OF OBSTRUCTIONS. PHONE UNDERGROUND SERVICE 1 3" 3" 3" ALERT AT (800) 227-2600, TWO (2) WORKING DAYS BEFORE DIGGING. 3. ALL PULLBOXES SHALL BE No. 6 AND CONDUIT SHALL BE (2") RIGID METAL UNLESS SHOWN OTHERWISE. 4. CONTRACTOR SHALL COORDINATE ELECTRIC SERVICE DETAILS AND SCHEDULING WITH THE SOUTHERN CALIFORNIA EDISON COMPANY WELL IN ADVANCE OF NEED. 5. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER IN THE FIELD FOR EXACT O W -' POLE EQUIPMENT LOCATIONS PRIOR TO FINAL PLACEMENT. , ' C•� CHECKED BY: A VED BY: DRAWING NO.: 1 VANESSA MUN RCE 67583 DATE V.M. � rl Y �mmlup-rp Aj i i ''` 3475 1 6. ALL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA DATE ENGR. ENGINEERING DIVISION PRIOR TO COMMENCEMENT OF WORK. DATE 7. ALL STREET -CROSSING CONDUITS THAT CANNOT BE BORED SHALL BE INSTALLED PER DETAIL "C", THIS SHEET AND THE SPECIAL PROVISIONS. 8. CONTROLLER CABINETS SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS. MODIFY SPRINKLER SYSTEMS AS DIRECTED BY THE ENGINEER IN THE FIELD. 9. FOR CITY FURNISHED EQUIPMENT TO BE INSTALLED BY CONTRACTOR SEE THE SPECIAL PROVISIONS. 10. ALL VEHICLE INDICATIONS SHALL BE 12" AND HAVE L.E.D. SIGNAL MODULES. ALL PEDESTRIAN HEADS SHALL HAVE L.E.D. PEDESTRIAN MODULES. 11. CONTRACTOR SHALL REFER TO THE CITY TRAFFIC ENGINEER IN THE EVENT OF A CONFLICT M 1-1 OR POTENTIAL CONFLICT WITH THESE PLANS AND/OR SPECIFICATIONS FOR THIS PROJECT. 12. SEE DRAWING 3154 SHEET 14 AND 15 OF 15 FOR SIGNING AND STRIPING WORK. POLE TRAFFIC SIGNAL CONSTRUCTION NOTES: INSTALL CITY FURNISHED TYPE 90 CONTROLLER ASSEMBLY (CONTROLLER EQUIPMENT PACKAGE) COMPLETE WITH TYPE R/W R/W n "R" CABINET, SOLO PRO DETECTION AND AUXILIARY REQUIRED TO PROVIDE THE OPERATION SHOWN (SEE SPECIAL MAST -ARM MOUNTING PROVISIONS). CONTROLLER CABINET AND FOUNDATION TO BE INSTALLED PER CITY STANDARD EQUIPMENT DRAWING CLAMP FOR MODEL 711 OPTICAL DETECTOR 4004. CONNECT SIC PER TRAFFIC SIGNAL CONTROLLER MANUFACTURER'S REQUIREMENTS. DINSTALL TYPE III -BF SERVICE EQUIPMENT ENCLOSURE PER CITY OF FONTANA AND SOUTHERN CALIFORNIA DETAIL "B" EDISON COMPANY REQUIREMENTS (SEE SPECIAL PROVISIONS). LOCATE A SERVICE ENCLOSURE A MINIMUM OF 6' FROM CONTROLLER CABINET. ❑3 INSTALL MODEL 711 UNIDIRECTIONAL, SINGLE CHANNEL OPTICOM DETECTOR PER DETAIL "B", THIS SHEET, AND AS DIRECTED BY THE ENGINEER IN THE FIELD (SEE SPECIAL PROVISIONS). 4❑ INSTALL CITY FURNISHED IMAGE SENSOR UNIT PER CITY STANDARD DRAWING 133 AND AS DIRECTED BY THE ENGINEER IN THE FIELD. EINSTALL TYPE H SERVICE RISER, WITH PULLROPE PER SCE REQUIREMENTS. COORDINATE INSTALLATION WITH AN EDISON SERVICE PLANNER 48 HOURS PRIOR TO CONSTRUCTION. ❑6 INSTALL 2" CONDUIT, WITH 6 PAIR #19 SIC PER SPECIAL PROVISIONS. F7 INSTALL 6 - 1.5" SCHEDULE 40 HDPE CONDUITS PER DETAIL "D". THE CONDUITS SHALL BE COLOR CODED R/W- c & G I Q 6 -Q 66' O Z ! li 45 l m o r` z I N �I ., o j 18 12' �l $ 05 o� 0502 02 02. 02 &05 08 R73-2 8 4J 04 4 08 T --. 1 11 8 R34 INSTALL 2 3" AND 2-5" CO DUIT W/ PULLRO 014/FUTURE SCE. 7 CONDUIT I A BE STUBBED OUT AT BCR AN FSC 19 08 ITY OF FONTANA COUNT OF SAN BERNA DIN 1 04 R34 8 -- _.- _- 1 1 __-�. -_ 3 04 4 0801 6 8 J R73-2 04 F y"06 ~ 06 ✓ --- P 06 01 01 I R/W c& ORANGE, YELLOW, RED, ORANGE CONDUIT. NSTALBL�PULL BROPE N THELUE. AND REMAINING CONDUITS UNt FORFUO URE CABLNNtLI E. CONDU 01-11 If 1 SWEEPSHIN E COUNTY OF SAN BERNARDINO SHALL BE INSTALLED WITH A MINIMUM 10 -FOOT RADIUS. PUBLIC WORKS DEPARTMENT Q8 INSTALL SIGN NOTED AND HARDWARE MOUNTING ES -7N, DETAIL "U" PER CALTRANS STD. PLANS. "COUNTY JURISDICTION ONLY" ❑9 INSTALL P48 PULLBOX (48.5 L x 30.5 W x 30 D), PRE -CAST CONCRETE, HAVE LOCKING LIDS, AND BE LABELED "COMMUNICATIONS". INSTALL 3" PVC CONDUIT WITH 1/4" POLY PULL ROPE PER SCE REQUIREMENTS. COORDINATE SERVICE WITH SCE (GREG KLOCK AT (909) 357-6585). VERIFY PHONE NUMBERS AT TIME OF CONSTRUCTION. O 1 �' 111 INSTALL TENON. CAP FOR FUTURE USE. CHIEF TRAFFIC DIVISION DATE: REV. !11 w 45' 52' ' -�U SEE DRAWING NUMBER 3480, SHEET 2 OF 3 FOR MIDBLOCK DETAILS R/W IC & G CONDUCTOR SCHEDULE 2 1 CIRCUIT OR RUNS 1 2 3 4 5 6 7 8 9 1 1 1 AWG. POLE o POLE VIDEO SVC 1 1 2 - 4 - 2 2 2 1 1 - U OPTICOM CABLE 1 1 1 1 1 2 1 2 1 - 1 2 1 2 1 2 1 2 o POLE CONDUIT SIZE 3" 1 3" 3" 3" 3" 1 4" 1 4" 1 4" 1 3" 1 3" 3" 3" z O W -' POLE F pF CA , ' C•� CHECKED BY: A VED BY: DRAWING NO.: 1 VANESSA MUN RCE 67583 DATE V.M. � rl Y �mmlup-rp Aj i i ''` 3475 1 Z :� REVISION DESCRIPTION DATE ENGR. CITY DATE Q POLE 1-1 1-1 1-1 POLE cy- POLE - O POLE - 0 0 m POLE TOTAL 1 1-1 1 2-2 3-3 1 3-3 - 5-5 5-5 5-5 4-4 3-3 2-2 1-1 10 ILUMINAIRE 1 2 1 2 1 - II - II - 1 2 1 2 1 2 1 2 - -E0 VIDEO CABLE 1 1 1 1 2 11 4 -1 2 1 2 1 2 1 1 1 1 - ID DET. VIDEO SVC 1 1 2 - 4 - 2 2 2 1 1 - OPTICOM CABLE 1 1 1 1 1 2 1 2 1 - 1 2 1 2 1 2 1 2 1 1 1 1 - CONDUIT SIZE 3" 1 3" 3" 3" 3" 1 4" 1 4" 1 4" 1 3" 1 3" 3" 3" R/W AVENUE O _l 5 10 1 EP 5 L PP SERVICE FEED POINT 21 22 JOINT TRENCH 1 2 C, 2#6 (SIGN L EP R/W & 5A 2" C. 2#10 (LUMINAIRE) 6] HEADER CUT 0.03' LIP 1' 1' a NEW A.C. _ 1"=20' 10 5 0 10 20 40 TACK COAT COMPLETE SURFACE BEING PAVED EXISTING 0.10' MIN. AC SURFACING J SEE DRAWING NUMBER EXIST CURB 3480, SHEET 2 OF 3 AND/OR GUTTER FOR MIDBLOCK 6-1.5" SCH 40 HDPE DETAILS CONDUITS AND 4 -SACK ORANGE -PEA GRAVEL BACKFILL -- R/W DUCT INSTALLATION AND TRENCH REPAIR DETAIL "D" LEGEND N.T.S. ►� - VIDEO DETECTION CAMERA (PER CITY OF FONTANA STANDARD DETAIL 133). REFLECTORIZED NON -ILLUMINATED STREET NAME SIGN (R.S.N.S.) [PER CITY OF FONTANA STANDARD DETAIL 132]. UNI -DIRECTIONAL , SINGLE CHANNEL OPTICAL DETECTOR. DIAL TWO WORKING BEFORE DAYS BEFORE YOU DIG YOU DIG TOLL FREE 1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT Q z Q z z Q z 0 Q Z Q Z 0 AW LA, L D LIJ Q Z Q Q F— Z Ln Ld D L,J Q LiJ 2 U rx SERVICE ADDRESS 145513 C k a rr �_vp­ w U QROFESS/p PLANS PREPARED BY: CITY OF FONTANA, CALIFORNIA WILLDAN cSAM �c`y 13191 Crossroads Parkway North, Suite 405 TRAFFIC SIGNAL INSTALLATION PLAN Industry, CA 91746-3497 Dom'"" SCALE: 04 ao N0. 67583 * EXP. 06-30-07 * J'9r CIV 1� C) (562) 908-6200 M H CHERRY AVENUE 1 "-20' UNDER THE SUPERVISION OF: DATE: DESIGNED BY: J. J.M.D. -__7SA AVENUE 4/30/04 O^ rn F pF CA , ' C•� CHECKED BY: A VED BY: DRAWING NO.: 1 VANESSA MUN RCE 67583 DATE V.M. � rl Y �mmlup-rp Aj i i ''` 3475 1 Z :� REVISION DESCRIPTION DATE ENGR. CITY DATE z Q z 0 Q Z Q Z 0 AW LA, L D LIJ Q Z Q Q F— Z Ln Ld D L,J Q LiJ 2 U