HomeMy WebLinkAbout3474-1POLE SCHEDULE o LL STANDARD MA5TARM5 LUMINAIRE 5167NAL MOUNTING PHASE PED PUSH BUTTON R5.N5. PLACEMENT REMARKS G TYPE HT. 516. LUM. H.P5.V. MA5T ARM POLE PED. PHASE LOGATION ME%A6E A B A 26A-4-80 35' 40' 15' 250H MA5 MA5 5V -1-T 5P -1-G5 - - GhcrQj Ave 15.5 15 04 VEHICLE B I -A 10' - - - - TV -I -T 5P -1-G5 8 5 b.0 2.5 G 2qA-5-SO 35' 65' 15' 250H MA5 MA5 MA5 - - - - 51over Ave b5 13.0 07 VEHICLE D I -A 10' - - - - TV -2-T 5P -1-G5 2 H - Ib.O 2.5 E 26A-4-80 35' 40' 15' 1 250H MA5MA5 5V -1-T 5P -1-G5 1 2 H Ghcrqj Ave 6,0 25 04 PED F I -A 10 - _ - - TV -2-T 5P -1-G5 4 N - 15.0 2.5 - G 2CIA-5-80 35' 55' 15' 250H MA5 MA5 MA5 5V -1-T 5P-1-65 4 N 51over Ave 8.0 2.5 $2 FM H I -A 10' - - - - TV -2-T 5P -1-G5 6 E - 17,0 25 1 2 PPB 3110" - - - - - - b E - 105 2.5 M PPB J PPB 2 - - - - - - 8 5 - 22.0 3.0 I KA I -A 1 10' 1 - I - - - TV -1-T I 5P -1-G5 - - - 10 1 14 TOTAL 0 ALL EQUIPMENT 15 EX15TINO UNLESS OTHERWISE NOTED. BARRIER PHASE DIAGRAM CIRCUIT 1+ I A1AAA_aAA2A PHASE PHASE 2 PHASE 5 PHASE I PHASE 51 PHASE 61 PHASE -11 PHASE TRAFFIC SIGNAL CONSTRUCTION NOTES: ❑EXISTING CONTROLLER ASSEMBLY INCLUDING TYPE "P" CABINET, TYPE qO CONTROLLER, AND APPURTENANT EQUIPMENT. INSTALL 2" CONDUIT INTO EXISTING NEMA 3R TELEPHONE BOX FOR 51C WIRING CONNECTION TO CONTROLLER AS DIRECTED BY THE ENGINEER IN THE FIELD. CONNECT SIG TO CONTROLLER PER MANUFACTURER'S RE QUIREMENT5. ❑2 EXISTING TYPE III -BF SERVICE EQUIPMENT ENCLOSURE INCLUDING THE FOLLOWING 1201240V ONE (i) PHASE SERVICEE WITH 120V METERED SIGNAL CIRCUIT, 120V CIRCUIT BREAKER, 30A LIGHTING CIRCUIT BREAKER, 30A LIGHTING CIRCUIT BREAKER, 15A AUT05COPE CIRCUIT BREAKER,PEG FOR LIGHTING 5 G IN SERVING UTILITY PORTION OF ENCLOSURE. 3 INSTALL 21 CONDUIT, WITH 6 PAIR #Iq SIG PER SPECIAL PROVISIONS.N5. ❑INSTALL 6 - 1.5" 56HEOULE 40 HDPE CONDUITS PER DETAIL "C". THE CONDUITS SHALL BE COLOR CODED ORANGE, YELLOW, RED, BLACK, BLUE, AND GREEN. INSTALL ONE (1) INTERCONNECT GABLE ((9PR #Iq) IN THE ORANGE CONDUIT. INSTALL PULL ROPE IN THE REMAINING CONDUITS FOR FUTURE GABLE. CONDUIT 5WEEP5 SHALL BE INSTALLED WITH A MINIMUM 10 -FOOT RADIUS. R5 INSTALL P48 PULLBOX (48.5 L x 30.5 W x 30 D), PRE -CAST CONCRETE, HAVE LOCKING LIPS, AND BE ED COMMUNICATIONS11 . LABELED E B L II G0NDUG TOR 5GHEOULEA AWC CIRCUIT RUN NUMBER I A1AAA_aAA2A R2 (5)_- r R 63 I 01 VEHICLE 3 02 VEHICLE R-73 tr 03 VEHICLE n -r _ '— -. J w` 04 VEHICLE ./ 12 F 15' $5 VEHICLE I ,.. f Av 1 4)2 * VEHICLE 3 DET "D 07 VEHICLE 3 3 3 3 3 3 3 6 M VEHICLE 3 $2 PED - 2 2 - 2 2 2 4 #14 04 PED - - - 2 2 2 2 2 * PED - - 2 - - 2 2 4 M PED 2 2 2 - - - - 4 $2 FM I I I - I I 1 2 04 FPB - - - - 1 2 2 2 06 PPB - - - - - - 1 2 M PPB - 1 2 - - - - 2 PPB COMMON i I I I I 1 1 2 5PARE5 3 3 3 3 3 3 3 6 TOTAL 13 22 28 12 22 28 32 bq #12 AUT05COFE - 2 2 2 2 2 2 - LUMINAIRE - 2 2 1 2 2 2 2 - # 10 516NAL COMMON I I I i I I I 2 TOTAL I 1 3 3 3 3 3 3 2 VIDEO GABLE - I I I 1 2 2 4 OPTICOM GABLE - I i I 1 1 2 2 4 GONDU I T 51 ZE 2.5" 3" 3" 2.5" 3 3 3 -3' GONDU I T STATUS I (E) I (E) (E) (E) (E) (N) (E) (E) A ALL CONDUCTORS ARE EX15TING ALL CONDUITS ARE EXISTING UNLESS OTHERWISE NOTED. (N) = NEW a DETAIL "A" N.T.S. EX 2" G 2 #10 4 #12 G34 R3 f R26E(MOD r I I R26(S) 1 �iF SLOVER ' L::;� J I 2 OA Ltj Rb " dui ri 05 OLA EX. 2 G, 2 #6, 1 #8 X106T r 8 19 Rl3 3 1 If- '. r„ ............ ,t r r " DET "0" D 3 i � � s� P i 4)4 rT, m rl 03 LJ rZ LZ (V R28A(S) L - PP — PP TYPEPL R HEADER GUT TACK GOAT 0.03' LIP COMPLETE 1, 1, SURFACE BEING PAVED <.e ' n'• EXISTING AG SURFACING NEW A.G. 0.10' MIN. m EXI5T CURB ANWOR CjUTTER MAST -ARM MOUNTING CLAMP FOR MODEL '111 OPTICAL DETECTOR DETAIL "B" N.T.S. r 6 -IS" 50H 40 HDPE CONDUITS AND 4-5ACK ORANGE -PEA GRAVEL BACKFILL DUCT INSTALLATION AND TRENCH REPAIR DETAIL "G" N.T.S. rs " e - iml T., DIAL TWO WORKING BEFORE DAYS BEFORE YOU DIG YOU DIG TOLL FREE 1-b00-271-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT 3 1 1 W Z 1 1 R/W 22' 9A_7 Em R/W TRAFFIC SIGNAL GENERAL NOTES: I. TRAFFIC SIGNAL AND LIGHTING SHALL CONFORM TO THESE PLANS, THE SPECIAL PROVISIONS, THE CITY OF FONTANA STANDARD PLANS AND SPECIFICATIONS, AND THE STATE OF CALIFORNIA STANDARD SPECIFICATIONS SECTION 86 AND STANDARD PLANS (DATED JULY 2002). 2. LOCATION OF ALL UNDERGROUND FACILITIES ARE APPROXIMATE. THE CONTRACTOR SHALL POTHOLE TO DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS ON THE JOB SITE. HAND DIG FOUNDATIONS UNTIL CLEAR OF OBSTRUCTIONS. PHONE UNDERGROUND SERVICE ALERT AT (800) 22-7-2600, TWO (2) WORKING DAY5 BEFORE DIGGING. 3. ALL PULLBOXE5 SHALL BE No. 6 AND CONDUIT SHALL BE 2" RIGID METAL UNLE55 SHOWN OTHERWISE. 4. CONTRACTOR SHALL COORDINATE ELECTRIC 5ERVIGE DETAILS AND 50HEOULINO WITH THE SOUTHERN CALIFORNIA E015ON COMPANY WELL IN ADVANCE OF NEED. 5. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER IN THE FIELD FOR EXACT EQUIPMENT LOCATIONS PRIOR TO FINAL PLACEMENT. 6. ALL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA ENGINEERING DIVISION PRIOR TO COMMENCEMENT OF WORK. "1. ALL VEHICLE INDICATIONS SHALL BE 12" AND HAVE L.E.D. SIGNAL MODULES. ALL PEDESTRIAN HEADS SHALL HAVE L.E.D. PEDESTRIAN MODULES. COQ o I I 8. SEE DRAWING 3154 SHEET 14 AND 15 OF 15 FOR 516NING AND STRIPING WORK. z o i q. ALL 5TREET-CRO551NG CONDUITS THAT CANNOT BE BORED SHALL BE INSTALLED PER zo Q��R26(S� DETAIL "D", THI5 SHEET AND THE SPECIAL PROVISIONS. z I I" =20 10. EXISTING LIGHTING TO BE REMOVED SHALL REMAIN IN OPERATION UNTIL NEW LIGHTING cr C) m io 5 0 �o so 4o IS OPERATIONAL, SEE SPECIAL PROVISIONS. 11. CONTRACTOR SHALL REFER TO THE CITY TRAFFIC ENGINEER IN THE EVENT OF A CONFLICT F= a OR POTENTIAL CONFLICT WITH THESE PLANS AND/OR SPECIFICATIONS FOR THI5 PROJECT. 1 18 12 i ' 0 3 _ R66 LEGEND }f -f } _J , --� ------ -- �- �' z, = R�3_ , , ;j , r ; OC `rl �o - EX15TINO VIDEO DETECTION CAMERA (PER CITY OF FONTANA STANDARD ' 1�DETAIL 133) "I 1 O - EXISTING REFLECTORIZED NON -ILLUMINATED STREET NAME SIGN (R.S.N.5) [PER CITY �5 `2 \ 02 \r ; v;3 r r `i i r O I OF FONTANA STANDARD DETAIL 1323 r._4_0- EXISTING UNI -DIRECTIONAL , SINGLE CHANNEL OPTICAL DETECTOR • O AVENUE �' r_� R18-2 ` /'�p8BOLA R35 ,R T "E" IJ r ,,,,.,.v.,.,.,, r _............ .._ �., ga. ,•a9 —•^p,—'—"�_t— tR, .ua � J 21 22 COUNT' OF SAN B_ERNARDIN CITY OF FONTANA i r T .-._..._...._ _..__...................... _.......... Y wv ►'. I I ' i._._..... .............................. ............:a"i .. ._ ..._ c�z ..._._........_---- ---- R"7=3r Ir; aJ I— 04 Ln J.......-..— . ...... ..... r r, r II L �-pp R35 02 r R6 -ra' ,;' R35 �, will H �F— tiJ v ,. _ II 1 II 1 1 tl `L 5j 4:]SEE DRAWING NUMBER 3480, SHEET 3 OF 3 FOR MIDBLOGK TACK GOAT COMPLETE SURFACE BEING PAVED Y wv ►'. I I ' R2 (5)_- r R 63 I 3 R-73 tr n -r _ '— -. J w` ./ 12 F 15' I ,.. f Av 1 4)2 3 DET "D II 1 II 1 1 tl `L 5j 4:]SEE DRAWING NUMBER 3480, SHEET 3 OF 3 FOR MIDBLOGK TACK GOAT COMPLETE SURFACE BEING PAVED c ,,,.................w...,.w+,».rwe�,.ww....,w+.,wws.0 sww.,A ,v ... + ... ,m ..,,m........,...... ------------- , 3 R2 R26(S) EXISTING DETAILS NEW A G AG SURFACING 2 -SACK SLURRY MIX 0.10' MIN. (INITIAL POUR TO BE FLU5H WITH SURROUNDING SURFACE) RIGID METAL CONDUIT(5) (INSTALLED WITH 18" MIN. COVER) TRENCH REPAIR DETAIL "D" N.T.5. 0 R 0 Y G ' YA GA DETAIL "E" N.T.S. z OL Z O V L- Q O J z VI _%3 L- QLL 1 lu z `LLI I LJl Lu z Lu La T_ 0 2 r I 3 c ,,,.................w...,.w+,».rwe�,.ww....,w+.,wws.0 sww.,A ,v ... + ... ,m ..,,m........,...... ------------- , 3 R2 R26(S) EXISTING DETAILS NEW A G AG SURFACING 2 -SACK SLURRY MIX 0.10' MIN. (INITIAL POUR TO BE FLU5H WITH SURROUNDING SURFACE) RIGID METAL CONDUIT(5) (INSTALLED WITH 18" MIN. COVER) TRENCH REPAIR DETAIL "D" N.T.5. 0 R 0 Y G ' YA GA DETAIL "E" N.T.S. z OL Z O V L- Q O J z VI _%3 L- QLL 1 lu z `LLI I LJl Lu z Lu La T_ 0