Loading...
HomeMy WebLinkAbout3461-4IRRIGATION LEGEND SYMBOL MFG. MODEL NO. DESCRIPTON RAD. GPM PSI lb TORO 570 Z-PRX-12P-COM-5Q QUARTER SPRAY HEAD 5' .10 30 0 TORO 570 Z-PRX-12P-COM-5H HALF SPRAY HEAD 5' .20 30 i TORO 570 Z-PRX-12P-COM-8Q QUARTER SPRAY HEAD 8' .25 30 • TORO 570 Z-PRX-12P-COM-8H HALF SPRAY HEAD 8' .50 30 @) TORO 570 Z-PRX-12P-COM-8F FULL SPRAY HEAD 8' 1.0 30 b TORO 570 Z-PRX-12P-COM-12Q QUARTER SPRAY HEAD 12' .50 30 0 TORO 570 Z-PRX-12P-COM-12H HALF SPRAY HEAD 12' 1.09 30 � TORO 570 Z-PRX-12P-COM-12F FULL SPRAY HEAD 12' 2.19 30 TORO 570 Z-PRX-12P-COM-15Q QUARTER SPRAY HEAD 15' .85 30 0 TORO 570 Z-PRX-12P-COM-15H HALF SPRAY HEAD 15' 1.65 30 @ TORO 570 Z-PRX-12P-COM-15F FULL SPRAY HEAD 15' 3.60 30 El TORO 570Z-PRX-12P-COM-2SST STRIP SPRAY HEAD 2X6' .09 30 0 TORO 570Z-PRX-12P-COM-4EST END SPRAY HEAD 4X15' .45 30 0 TORO 570Z-PRX-12P-COM-4SST STRIP SPRAY HEAD 4X30' .90 30 + TORO 570 Z-PRX-6P-COM-8Q QUARTER SPRAY HEAD 8' .25 30 V TORO 570 Z-PRX-6P-COM-8H HALF SPRAY HEAD 8' .50 30 QQ TORO 570 Z-PRX-6P-COM-8F FULL SPRAY HEAD 8' 1.0 30 b TORO 570 Z-PRX-6P-COM-12Q QUARTER SPRAY HEAD 12' .50 30 V TORO 570 Z-PRX-6P-COM-12H HALF SPRAY HEAD 12' 1.09 30 Q TORO 570 Z-PRX-6P-COM-12F FULL SPRAY HEAD 12' 2.19 30 TORO 570 Z-PRX-6P-COM-15Q QUARTER SPRAY HEAD 15' .85 30 0 TORO 570 Z-PRX-6P-COM-15H HALF SPRAY HEAD 15' 1.65 30 @ TORO 570 Z-PRX-6P-COM-15F FULL SPRAY HEAD 15' 3.6 30 fB TORO 570 Z-PRX-6P-SB-2-180-PC2 STREAM BUBBLER 2X6' .09 30 �D 570 Z-PRX-6P-SB-90-PC2 t'J RAIN BIRD 5006 -PC -SAM -MPR -25Q ROTOR HEAD 23' .74 25 t'J RAIN BIRD 5006 -PC -SAM -MPR -25H ROTOR HEAD 23' 1.44 25 Q RAIN BIRD 5006 -FC -SAM -MPR -25F ROTOR HEAD 23' 2.78 25 ® RAIN BIRD 5006 -PC -SAM -MPR -30Q ROTOR HEAD 29' 1.03 25 Q RAIN BIRD 5006 -PC -SAM -MPR -30H ROTOR HEAD 29' 2.15 25 © RAIN BIRD 5006 -FC -SAM -MPR -30F ROTOR HEAD 29' 4.24 25 (CONTRACTOR TO DECIDE IN FIELD WHICH BUBBLER TO INSTALL) CONTRACTOR MUST USE TORO 570 ADJUSTABLE ARC NOZZLES OR 570 V-15 NOZZLES TO AVOID OVERSPRAY AND INSURE FULL COVERAGE. THE CONTRACTOR IS REQUIRED TO USE 570Z -COM (CHECK-O-MATIC) POP-UP BODY'S ON ANY HEADS ON A SYSTEM WITH Y OR GREATER THAN ELEVATION CHANGE- OR AS NEEDED IN FIELD. THE 8' SPRAY HEADS MAY BE SUBSTITUTED WITH 10' NOZZLES AS REQUIRED IN THE FIELD. ANY HEADS THE NEED A REDUCTION OF MORE THAN 50% OF THE LISTED SPRAY PATTERN WILL REQUIRE TORO PCD SCREENS. R DOMESTIC WATER METER - REFER TO CIVIL PLANS. Lj FEBCO 825Y 2" REDUCED PRESSURE BACKFLOW PREVENTER IN LEMUR VANDAL - RESISTANT STEEL MESH ENCLOSURE - SEE DETAILS H NIBCO T-113 GATE VALVE (3" OR SMALLER) - LINE SIZE Locate in a 10" round lockable plastic valve box. ® SUPERIOR 950DW SERIES REMOTE CONTROL VALVE (SIZE INDICATED) Locate in a 12" x18"rectangular lockable plastic valve box per valve. All valves and plastic valve boxes to be numbered. QQ 2" SUPERIOR 3000 SERIES MASTER VALVE (NORMALLY CLOSED) Q DATA INDUSTRIAL MODEL 228 PV "IR" FLOW SENSOR 0 RAINBIRD QUICK COUPLER 33D - Locate in a 10" round lockable plastic valve box @ 150' o.c. maximum. Support with a sch 40 pvc pipe stake and two house clamps each. AUTOMATIC CONTROLLER LOCATION Provide controller charts per City requirements. Contractor to also install a WCS 'Rainguard' Rain shutoff device @ the controller. Locate in a vandal resistant area free from overhead obstruction and outside of the irrigation spray pattern. PVC SCH. 40 MAINLINE- 1-1/2" AND SMALLER. PVC CLASS 315,2- AND LARGER. 24" COVER UNDER PAVING, 18" COVER IN PLANTING AREAS, SIZES AS INDICATED. PVC CLASS 200 LATERAL LINE- 12" COVER IN PLANTING AREAS. PVC SCHED. 40- 24" COVER UNDER PAVING - - -_ - PVC SCH 40 MAIN AND LATERAL LINE SLEEVE 2x DIAMETER OF PIPE Pipe, controller wires and communication cable to be 24" deep under paving and 18" below walls. - - - SCH. 40 WIRE SLEEVE - Locate in a seperate trench per UBC and City Specifications. INDICATES VALVE NUMBER r-- INDICATES CONTROLLER INDICATES VALVE GPM INDICATES VALVE SIZE IRRIGATION NOTES DIAGRAMMATIC PLAN THIS SYSTEM IS DIAGRAMMATIC. ALL PIPE, VALVES, ETC. SHOWN WITHIN PAVED AREAS ARE FOR DESIGN CLARIFICATION ONLY AND SHALL BE INSTALLED IN PLANTING AREAS AND JOINT TRENCHES WHEREVER POSSIBLE. SPRINKLER ADJUSTMENT REQUIRED THE IRRIGATION CONTRACTOR SHALL FLUSH AND ADJUST ALL SPRINKLER HEADS FOR OPTIMUM PERFORMANCE AND PREVENT OVERSPRAY ONTO WALKS AND ROADWAYS AS MUCH AS POSSIBLE. THIS SHALL INCLUDE SELECTING THE BEST DEGREE OF ARC TO FIT THE EXISTING SITE CONDITIONS. CONTRACTOR TO USE PRESSURE COMPENSATING SCREENS WHEN RADIUS IS REDUCED MORE THAN FIFTY PERCENT (50a/o). FIELD CONDITIONS DO NOT WILLFULLY INSTALL THE SPRINKLER SYSTEM AS INDICATED ON THE DRAWINGS WHEN IT IS OBVIOUS IN THE FIELD THAT UNKNOWN OBSTRUCTIONS OR GRADE DIFFERENCES EXIST AND SHOULD BE BROUGHT TO THE ATTENTION OF THE CONTRACTING OFFICER. IN THE EVENT THAT THIS NOTIFICATION IS NOT PERFORMED, THE CONTRACTOR MUST ASSUME FULL RESPONSIBILITY FOR ANY REVISIONS REQUIRED. SWING JOINTS INSTALL ALL HEADS WITH DOUBLE OR TRIPLE SWING JOINTS, USING STREET ELLS, AS PER DETAIL. MINIMUM PRESSURE AND MAXIMUM GALLONS REQUIRED THE SPRINKLER SYSTEM DESIGN IS BASED ON A MINIMUM OPERATIONAL PRESSURE AND A MAXIMUM DEMAND AT THE POINT OF CONNECTION, AS NOTED ON THE PLAN. BEFORE INSTALLING THE SYSTEM, CHECK POINT OF CONNECTION AND IMMEDIATELY NOTIFY CONTRACTING OFFICER IF PRESSURE IS NOT AS NOTED OR THE REQUIRED GALLONS PER MINUTE IS NOT AVAILABLE. WATER LINE UNDER PAVING ALL MAINLINE UNDER PAVING SHALL BE INSTALLED 24" DEEP. ALL LATERAL LINES UNDER PAVING SHALL BE SCH 40 PVC AND INSTALLED 24" DEEP. SYSTEM COVERAGE THE IRRIGATION CONTRACTOR IS TO ADJUST HEAD LOCATIONS IN THE FIELD IN ORDER TO GUARANTEE 100% COVERAGE. CONTRACTOR TO CONTACT THE CONTRACTING OFFICER PRIOR TO ANY MAJOR CHANGE(S) RESULTING IN ADDITIONAL COST TO THE OWNER. PROVIDE 20 AMP 2 POLE BREAKER FOR NEW PUMPS WHERE APPLICABLE 50 A 2P 120/240 0 3W 12 CIR PANEL L --J FINISHED GRADE 3' •. je•ye e- 4" GROUND FOR ELECTRICAL L_ 3/4"C, 1#6 IRRIGATION C, BOARD METER PUMP TEMPLAn SIGNAL POWER --- CONTROLLER WIRES END VIEW NTS �..,. Lta;k 4 t LIWL t IL L..IL 1 C (ire+ IN 0 VW r t i'�" Ir' r.._.. NOTE: ALL POWER WIRES, GROUND WIRES ETC. SHALL BE SEPARATELY SLEEVED AND SWEPT THROUGH ENCLOSED PAD WITH SCH 40 RIGID CONDUIT M SIZE OF EQUIPMENT - 46'W X 18"D X 54' HIGH /AND -SIZE OF CONIC. SLAB = 52"W X 24"D X 8" THICK /-W/#4 REBARS AT 12' O.C. TYP 8" DIA. X 12" D. BOTTOMLESS GROUND WELL WITH PARKWAY COVER, FILL WITH PEA GRAVEL i : 41 •e ..b f4 REBARS TYP. 5/8 -DIA X 10' DRIVEN GROUND �.r ROD PER ARTICLE 250-81 ;:.. OF 1990 NEC '- GENERAL NOTES: PROVIDE 100A METER AND 50A/2P MAIN C/B WHERE INDICATED CONCRETE ON DRAWINGS XTRA MOUNTING PROVIDE PANELBOARD WHERE INDICATED ON DRAWINGS. SLAB PROVIDE IRRIGATION CONTROLLER CABINET WHERE INDICATED ON DRAWINGS. TERMINATE AT EXISTION HANDHOLE. PER S.C.E. COMPANY REQ. VERIFY EXACT LOCATION AND TERMINATION REQ. WITH S.C.E. CO. CONDUIT FOR PRIOR TO TRENCHING GROUND ROD INSTALLATION CONDUIT AND CONDUCTOR SIZES ARE BASED ON NONMETALJ_C CONDUIT -2 EXTRA 1' CONDUITS AND COPPER CONDUCTORS WITH TYPE "THHN/THWIN" INSULATION. EXTRA 24" --i EXACT LOCATION OF CONTROLLER SHALL BE AGREED UPON BY EDISON. CITY LANDSCAPE INSPECTOR AND CONTRACTOR PRIOR TO ANY TRENCHING OR FACES II WARE PLACEMENT STRONG BOX MODEL NO. SB- 24SS/120V _L\_ RAIN SHUTOFF DEVICE - SEE LEGEND 121. 1 e 1 0 CONTROLLER AND ENCLOSURE STRIP WIRES APPROX. 5/8" FROM ENDS 4L STEP 1 TWIST CONNECTOR UNTIL WIRE END REACHES BOTTOM STEP 2 MIX CONTENTS OF SEALING PACK, CUT 1/2 OFF END OF PACK AND INSERT CONNECTOR TO OPPOSITE END STEP 3 WRAP OPEN END OF SEALINGPACK WITH 4 TAPE. ALLOW TO SET UNTIL RESIN JELLS STEP 4 "SCOTCH" SEALING PACK WIRE CONNECTION CITY OF FONTANA IRRIGATION CONTROLLER STANDARD FOR COMMUNITY FACILITIES DISTRICTS (CFD'S) 1. Toro Network 8000 Model # 132-86-08, 32 station field satellite controller. 2. Mount in Strong Box Model No. SB-24SS/120V. (Stainless Steel) 3. Provide Rainmaster 32 PC 'Pigtail' for remote controll operation. 4. Provide Sensor Input Board (SIB) Model #995-63 to intr,rface with flow meter and rain shut off device. 5. Provide Radio Link Kit #89-7611 to communicate with central command. All radio equipment shall be compatible with VHF. 6. Provide ground rod and surge protection for each satellite controller. Contact: Curtis Newman California Turf (619) 520-6181 (619) 793-3999 (Pager) (800) 774-8873 (Main Office) Park and Landscape Development Section, Engineering Division Community Development Department, City of Fontana (1/26/98) oVli,%DSCA,9 CITY OF FONTANA '. A. Pat 4,pC TR- �� 2182 `G y/ LANDSCAPE PLANS * � * Mew Br KNOX AVENUE - WEST AS SHOWN s \ DIESIGM Ii* DAZE: 9lF OF CHSCM 9Y: APPROVED BY: /Q DIMG ND: 4 [WIT, ! 3461 CRY ENI R.C.E. 151 152 EV. DIE 1 T e S c A P e S Landscape Architecture and Planning 3195 B Airport Loop Dr. Costa Mesa, CA. 92626 Richard Polhamus, License CA -#2782 (949) 644-9370 (714) 210-3140 FAX 90 N JOB 03-017 CDUIT FOR O CONTROLLER WIRES FRONT VIEW NTS Z CONTROLLER AND ENCLOSURE STRIP WIRES APPROX. 5/8" FROM ENDS 4L STEP 1 TWIST CONNECTOR UNTIL WIRE END REACHES BOTTOM STEP 2 MIX CONTENTS OF SEALING PACK, CUT 1/2 OFF END OF PACK AND INSERT CONNECTOR TO OPPOSITE END STEP 3 WRAP OPEN END OF SEALINGPACK WITH 4 TAPE. ALLOW TO SET UNTIL RESIN JELLS STEP 4 "SCOTCH" SEALING PACK WIRE CONNECTION CITY OF FONTANA IRRIGATION CONTROLLER STANDARD FOR COMMUNITY FACILITIES DISTRICTS (CFD'S) 1. Toro Network 8000 Model # 132-86-08, 32 station field satellite controller. 2. Mount in Strong Box Model No. SB-24SS/120V. (Stainless Steel) 3. Provide Rainmaster 32 PC 'Pigtail' for remote controll operation. 4. Provide Sensor Input Board (SIB) Model #995-63 to intr,rface with flow meter and rain shut off device. 5. Provide Radio Link Kit #89-7611 to communicate with central command. All radio equipment shall be compatible with VHF. 6. Provide ground rod and surge protection for each satellite controller. Contact: Curtis Newman California Turf (619) 520-6181 (619) 793-3999 (Pager) (800) 774-8873 (Main Office) Park and Landscape Development Section, Engineering Division Community Development Department, City of Fontana (1/26/98) oVli,%DSCA,9 CITY OF FONTANA '. A. Pat 4,pC TR- �� 2182 `G y/ LANDSCAPE PLANS * � * Mew Br KNOX AVENUE - WEST AS SHOWN s \ DIESIGM Ii* DAZE: 9lF OF CHSCM 9Y: APPROVED BY: /Q DIMG ND: 4 [WIT, ! 3461 CRY ENI R.C.E. 151 152 EV. DIE 1 T e S c A P e S Landscape Architecture and Planning 3195 B Airport Loop Dr. Costa Mesa, CA. 92626 Richard Polhamus, License CA -#2782 (949) 644-9370 (714) 210-3140 FAX DVM CHK N JOB 03-017 L3 of 10 C Q Z W Z Z 00 rrW►�-� V O V z W 0 Z E-, a � W Cd Cdr'- • ,.., 01 z H W a O . Cd 00 O U C � � Cd u r011 W in �D DVM CHK DATE 7/14/03 JOB 03-017 L3 of 10 C Q Z W Z Z Q rrW►�-� V O V z W 0 Z 0 ►--� a � W z H DVM CHK DATE 7/14/03 JOB 03-017 L3 of 10 3/9/2004 I