Loading...
HomeMy WebLinkAbout3457-4115 CLEAN LACK FILL SATURATE AND COMPACT TO 9OR HARDSCAPING NATIVE BACKFILL 2" MINUS NON PRESSURE LATERAL LINE W/SLEEVE C4 PRESSURE SUPPLY LINE W/SLEEVE ilt s CONTROL WIRE SLEEVE . tQ ' SAND BACK FILL 2" MIN 6" MIN TESL INSTALL CONTROL WIRE SLEEVE ADJACENT TO THE PRESSURE SUPPLY LINE, SIZE PER SPEC. ALL SLEEVES TO BE SCH. 40 PVC AND TO BE 2X THE DIAMETER OF THE LINE TO BE SLEEVED. * INCREASE THIS DISTANCE TO 36" WHEN SLEEVING UNDER ROADWAYS AND COMMERCIAL TRAFFIC WAYS WHEN INSTRUCTED BY INSPECTOR. SLEEVES SHALL BE EXTENDED BEYOND HARDSCAPE TO POINTS AS REQUESTED BY INSPECTOR IF SLEEVES ARE TO BE USED AT A LATER DATE. CONTRACTOR SHALL TAPE ENDS AND PROVIDE A VERTICAL. MARK AT ENDS OF SLEEVING VISIBLE AT GROUND LEVEL. Nto(ESSI APPROVED BY: CITY OF FONTANA z51� CITY ENGINEER DATE: RosEWW WEDDLE SLEEVING DETAIL EV.12/dt/01 * DRAWN sy-. TIMOTHY RASTEDT. ave �, 'q Or uu��'� DATE OF LAST REVISION: STD. PLAN NO. 518 1 SHT. 1 OF 1 POP --UP SHRUB HEAD FINISH GRADE "- 12" - 12" I I -j SCH 80 PVC NIPPLE —«- THREADED. BOTH ENDS WALK OR CURB 1 1;2" 616 PVC STREET ELLS NOTE: o INSTALL 12" SHRUB POP—UP HEAD 1 1/2 of ABOVE F.G. O F.G. 1 1/2" BELOW WALK OR CURB o CHECK VALVE FOR LOW HEAD DRAINAGE acfssi APPROVED BY: CITY OF FONTANA . LAWN 14!'6'5" 11,. 2513 CRY ENGINEER DATE: ROBERT W. WEDDLE SHRUB POP-UP HEAD .fffl. 12/M/01>F CNL DRAWN BY: TIMOTHY RA5TEDT . �! OF cl<L11��! DATE OF LAST REVISION:I STD. PLAN NO. 523 1 SHT. 1OF1 SAA,. • .� 1 -� � Vj _ J 24" . EXACT LOCATION OF CONTROLLER SHALL BE AGREED UPON BY EDISON. CITY LANDSCAPE INSPECTOR AND CONTRACTOR PRIOR TO ANY TRENCHING OR WIRE PLACEMENT J6" MUM NW ES: PROVIDE 100.E METER AND 5OA/2P MAN C/O WHERE INDICATED 12" ON OMWNGS �, r a ' +• I.,- — �Wmft omwo r 90 SWEEP EUS CONTROUIR "MM FRONT VIEW NTS 16" IRRIGATION CONTROL. BOARD � � PROVIDE PANELBOARD WHERE INDICATED ON DRAWINGS. PROVIDE IRRK ATION CONTROLLER CABINET WHERE INDICATED ON DRAAW04M. ' TERMNATE AT EMSTK1N HANDHOLE. PER S.C.E. COMPAW REQ. VERIFY EXACT LOCATION AND TERf1NAT10N REQ. WITH S.C.E. CO. PRIOR TO TRENCHING CONDUIT ANO CONDUCTOR SIZES ARE BASED ON NONMETALLEC COMM AND COPPER CONDUCTORS WITH TYPE "THHN/TI1*N" MISULATOL I 11 METER FACES 1 1 U STREET METER I 1 + 1 w 3I BOX MODELG 0. SB— 24SS/120V SWEEP"CONDUITFOR ELLS CONTROLLER WIRES END VIEW ELECTRIC METER & IRRIGATION CONTROLLER ENCLOSURE APPROVED BY: CITY OF FONTANA k 2513 CRY ENGMIEER DATE: 5TRO N G BOX ROBERT W. WEDDLE DRAWN BY: 'TIMOTHY KASTEDT avw �fAo� tnL1F1NR►�� DATE OF LAST REVISION: STD. PLAN NO. 505 SHT. 200 CITY OF FONTANA IRRIGATION CONTROLLER STANDARD FOR COMMUNITY FACILITIES DISTRICTS (CFD'S) 1. Toro Network 8000 Model # 132-86-08, 32 station field satellite controller. 2. Mount in Strong Box Model No. SB-24SS/12OV. (Stainless Steel) 3. Provide Roinmoster 32 PC 'Pigtail' for remote controls operation. 4. Provide Cambell Scientific Inc,TE525 tipping bucket (Heavy Duty Model) 5. Provide Sensor -input Board (SIB) Model #995-63 to interface with flow meter and rain shut. off device. 6. Provide Radio Link Kit #89-7611 to communicate with central command. All radio equipment shall be compatible with VHF. 7. Provide ground rod and surge protection for each satellite controller. Contact: Curtis Newman California Turf 619 520-6181 619 793-3999 (Pager) 800 774--8873 Main Office) Park and Landscape Development Section, Engineering Division Community Development Department,_ City of Fontana (1/26/98) �� teas irrpAPPROVED BY: CITY OF FONTANA X126 CRY ENGINEER DATE: CONTROLLER 5TANDARD ROBERT W. WEDOLE It EXP. 12/31/01 * DRAWN BY: TIMOTHY KA5TEDT, aN1. OF I;1►ltid�``�. DATE OF LAST REVISION: STD. PLAN N0.505 1 SHT. 30F3 OWNER / DEVELOPER: BENCHMARK: S6. I a5 1 I ; A6-ry1 CALTRANS BENCHMARK NO. 8-17 NEW EST BRASS CAP IN CONCRETE S.C.E. TOWER LEG. HOME 343' N /0 HIGHLAND AVE., 0.2 MI. W/0 SAN SEVAINE RD., IN SOUTH CONCRETE BASE OF S.C.E. TOWER 19.5; 2.65 MI. W. ALONG 369 SAN MIGUEL DRIVE, SUITE 375—A HIGHLAND AVE. FROM SIERRA AVE. NEWPORT BEACH, CA 92660 (949) 640-6420 * FAX: (949) 640•--6484 MARK BY DATE ELEV.= 1428.6090 ENGINEER TAPE 4 5UNDLE CONTROL WIRE 6 20' O/C (TYP.) "SNAP TITS" CONNECTORS 4 EXPANSION COILS, 15 WRAPS AROUND 1/2" PIPE (TYP.) ADAPT TO LATERAL LINE REMOTE CONTROL VALVE (PER LEGEND) CHRISTY I.D. TAGS. SECURE TO SOLENOID PIGTAIL. FINISH GRADE 1/2" IN TURF, 2" IN GROUND COVER 12" X 18" RECT. PLASTIC VALVE SOX WITH HINGED, LOCKABLE TOP COLOR -GREEN 13RAN0 STATION I.D. ON LID PVC ELL 2"X4" REDWOOD FRAME 4" PEA GRAVEL CONTROL WIRE (TYP.) TO CONTROLLER PVC SCH 80 NIPPLE MAIN LINE WITH TEE OR ELL SL IPXSL IPXF IPT SCH 80 PVC UNION CONTROL WIRE TO OTHER VALVES COMMON WIRE TO OTHER VALVES NOTE: WHEN MORE THAN ONE VALVE IS LOCATED IN THE SAME AREA SPACE Y APART. REMOTE CONTROL VALVE IRRIG. CONT. 3" 4" PROVIDE 20 AMP 2 POLE BREAKER FOR NEW PUMPS WHERE APPLICABLE FINISHED CRADE GROUND FOR ELECTRICAL NOTE: ALL POWER WIRES, GROUND WIRES ETC. SHALL BE SEPARATELY SLEEVED AND SWEPT THROUGH ENCLOSED PAD WITH SCH 40 RIGID CONDUIT ALL SLEEVING SHALL BE A MINIMUM OF 18" BELOW FINISHED GRADE. ALL SLEEVING IS A GRAPHIC REPRESENTATION OF A TYP. INSTALLATION. SIZE OF EOUIPMENT - 46N X I WO X 54" HIGH AND SIZE OF CONC. SLAB - 52*W X 24"D X 8" T14ICK W/04 REBARS AT 12" O.C. 7YP • 4� M APPROVED BY:CITY 50 A ON SITE DRAWING 2P pp MESH M09EEL fit25126 120/240 FLOWETER/ BRASS BALL LOOSE KEY PORT 0 3W DRAROWVN ®Y: nMOTHY RA5TEDT. BRASS POPE VALVE 12 CIR CML DATE OF LAST REVISION: M. PLAN NO. PANEL N PRESS ,S DUNE NST BLOCA FRONT •, CITY OF FONTANA, CALI FO NIA 8" DEA. X 12" O. BOTTOMLESS GROUND WELL WITH PARKWAY COVER. FlLL WITH PEA GRAVEL. 5/I5"DIA X 10' DRIVEN GROUND r, ROD PER ARTICLE 250-81 OF 1990 NEC 3/4"C, 106 ELECTRIC METER & IRRIGATION CONTROLLER ENCLOSURE 1� ® gkof ES S1 APPROVED BY: CITY OF FONTANA Na 25126 A CITY ENGINEER DATE: STRONG BOX ROWW W. W EDMA * EXP. 12/31/oi DRAWN BY: TIMOTHY IZA5TEDT. Ova. OF E�t�SQd�! DATE OF LAST REVISION: STD. PLAN Ido -505 iSHT. 10173 NpSC41!�' 3612 MISSION /NN AVE RIVERSIDE, CALIF. 92501 L®ND.•.:® L/C. #1512 a Aae:I:.o:s PH. (909) 781-1930 8 -Anmm Im FAX (909) 686-8091 � ig a u e � enwa a e S�q a e %1� PREPARED BY: APPR. DATE TF OF CAS -SFO DATE: COUNTY PRESSURE REGULATOR IF APPROVED BY:CITY REQUIRED. SET AS SHOWN ON SITE DRAWING pp MESH M09EEL fit25126 BRASS EL FLOWETER/ BRASS BALL LOOSE KEY PORT VALVE 1 w DRAROWVN ®Y: nMOTHY RA5TEDT. BRASS POPE VALVE a CML DATE OF LAST REVISION: M. PLAN NO. 10 SHT. 1 OF 1 N PRESS ,S DUNE NST BLOCA FRONT DI.PSPC REDUCE PRESSURE BACKFLOW PREVENTER 4 PLACHES) -BRASS ELBOW -BRASS UNION 'BRASS PIPE VBALSSS BALL VE LOCK 13OX 4 REBAR FOOTING/FOUNDATION ENCL E 3/4" GRAVEL SEE NOTE BEI. WE BRASS ELBOW • • • • .. BRASS UNION r• W W _ - BRASS BALL • VALVE { /4 REBAR 12 PLAN Ll 21 r 1 t NOTE: BACKFLOW ENCLOSURE.LE MEUR E N D OR EQUAL 24"X60,X36. NIGH HINGED AT ONE END SECURE T'0 6'X8' FOOTING W/4" J BOLTS' (EQUIPMENT TO BE CENTERED INSIDE HOUSING) GENERAL NOTES 1. CONTRACTOR SHALT. FORM ENCLOSURE AND REQUEST INSPECTION PRIOR TO POURING FOOTING/FOUNDATION 2. CONTRACTOR SHALL USE 520-C-251DO CONCRETE. QQf}IESSip��`r' APPROVED M. CRY OF MONTANA CRY ENGINEER DATE: R0 "' �,� 8ERT W. WEDDILE TYP. BAC FLOW 4; Exp.12/31/OI DRAWN BY: TIMOTHY RASTEDT. ffq�E # �111tid��* DATE OF LAST REVISION: STD. PLAN NO.507 ISHT. 1 0F1 OF 14 WHITE WIRES (COMMON) BLUE V lz� WATERPROOF ALL WIRE CONNECTIONS AS PER I, REDT BLACK / rIl VALVE�MASTER CONTROL FLOW SENSOR DIAMETER SAME SIZE AS FLOW METER SIZE MINIMUM DI TANCE DOWNSTREAM 5X DIAMETER OF FLOW METER SIZE MINIMUM DISTANCE UPSTREAM 10X DIAMETER OF FLOW METER SIZE E 0 M ti 0 N W 0 CU Ips°i APPROVED BY:CITY OF ONTANA 9 x fit25126 CRY ENGINEER DATE: FLOWETER/ EXP. 12/31/01 * DRAROWVN ®Y: nMOTHY RA5TEDT. MASTER VALVE a CML DATE OF LAST REVISION: M. PLAN NO. 10 SHT. 1 OF 1 N CITY OF FONTANA, CALI FO NIA z .;�. PUBLIC WORKS DEPARTME T M o DRAWN BY -PARKWAY LANDSCAPE PLAN scALE: o JE FOR 1" = 30'-0" TRACT 16210 DESIGNED BY: DATE: JEIRR AT I O N XTMLS AUG 21, 2003 - z CHECKED BY AP OVED B. 2 .... DWG. N0. LSOHEET CIT ENGINEER: RICARDO SANDOVAL R.C.E. 152 3457 F 8 n