HomeMy WebLinkAbout3439-7SCALE IN FEET
0 80 120 160
SEE SHEET 6
fes..
TOLL FREE 1-800-227-2600
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
C
w
F2
US
! Z,
�W
>!
Q.
w
Q
U
7
RECORD DRAWING
THESE RECORD DRAWINGS HAVE BEEN PREPARED, IN
PART, ON THE BASIS OF INFORMATION COMPILED AND
FURNISHED BY OTHERS. THE ENGINEER WILL NOT BE
RESPONSIBLE FOR ANY ERRORS OR OMISSIONS WHICH
HAVE BEEN INCORPORATED INTO THE DOCUMENTS AS
A RESULT THEREOF.
BENCH MARK: # 615 BASIS OF BEARINGS:
THE BEARING OR N 89'40'40' E ALONG THE
RAILROAD SPIKE AT INTERSECTION OF SOUTH LINE OF SECTION 30,
CITRUS AVENUE AND LOS CEDROS TOWNSHIP 1 NORTH, RANGE 5 WEST,
AVENUE, IN POWER POLE NO. 9011E SAN BERNARDINO MERIDIAN, AS SHOWN ON
ON THE EAST SIDE OF CITRUS AVENUE. TR. NO. 15908, FILED IN BOOK 271, PAGES
4 THROUGH 39 OF MAPS, WAS USED
ELEVATION: # 1467.59 rS THE BASIS OR BEARINGS FOR THIS MAP.
CONSTRUCTION NOTES:
la— INSTALL 8" EXTRA STRENGTH V.C.P. SEWER.
2a— CONSTRUCT PRECAST CONCRETE MANHOLE PER CITY OF
FONTANA STD. DWG. NO. 112 (ID=48").
4O— INSTALL 4" EXTRA STRENGTH V.C.P. SEWER LATERAL PER
CITY OF FONTANA STD. DWG. NO. 125.
SEWER LATERAL TABLE
LOT #
DESIGN STA.
AS—BUILT STA.
BACKFLOW
34
10+63
SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT
COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL
SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER,
THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO
BRING THEM INTO CONFORMANCE WITH CONDITIONS AND
STANDARDS IN EFFECT.
NO
35
11+57
i
NO
36
11+77
NO
37
12+88
YES
38
13+08
NO
39
14+22
NO
40
14+44
NO
41
14+41
NO
42
14+15
NO
43
13+ 11
NO
44
12+91
YES
45
11+80
NO
46
11+60
NO
47
10+57
NO
REV.
REVISION DESCRIPTION
DATE
ENGR.
CITY
DATE
SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT
COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL
SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER,
THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO
BRING THEM INTO CONFORMANCE WITH CONDITIONS AND
STANDARDS IN EFFECT.
Q��v
�� de �rCFy
C No. 65195 �°
° o
* � `' �
,p Expl 9-30-05 tiP
gTeCIV1�-O�`'
OFCgLiF
Prepared Under The Supervision Of :
PREPARED IN THE OFFICE OF
MADOLE AND ASSOCIATES, INC.
10601 CHURCH STREET, STE. 107
RANCHO CUCAMONGA, CA 91730
PHONE (909) 948-1311
—Date-t�.
CITY OF FONTANA, CALIFORNIA
i
RECORD DRAWING
n
1/b•
SEWER IMPROVEMENTS PLANS
BY -
DRAG CC MJG
TRA CT .n 16363
7 NICHT STAR CT
DESIGNED BY:
MJG/LP
CH BY:
MJG/LP
PP OVED BY:
RCE 65195 EXP. 9-30-05
ITY ENGINEER . 5115 DATE
SCALE:
1 "=40'
DATE:
NOV. 2003
DRAWING NO.: 7
3439 8
J:\685-1650\sewer\sewO7.dwg, 04/29/2004 12:16:43 PM, cc