Loading...
HomeMy WebLinkAbout3439-7SCALE IN FEET 0 80 120 160 SEE SHEET 6 fes.. TOLL FREE 1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT C w F2 US ! Z, �W >! Q. w Q U 7 RECORD DRAWING THESE RECORD DRAWINGS HAVE BEEN PREPARED, IN PART, ON THE BASIS OF INFORMATION COMPILED AND FURNISHED BY OTHERS. THE ENGINEER WILL NOT BE RESPONSIBLE FOR ANY ERRORS OR OMISSIONS WHICH HAVE BEEN INCORPORATED INTO THE DOCUMENTS AS A RESULT THEREOF. BENCH MARK: # 615 BASIS OF BEARINGS: THE BEARING OR N 89'40'40' E ALONG THE RAILROAD SPIKE AT INTERSECTION OF SOUTH LINE OF SECTION 30, CITRUS AVENUE AND LOS CEDROS TOWNSHIP 1 NORTH, RANGE 5 WEST, AVENUE, IN POWER POLE NO. 9011E SAN BERNARDINO MERIDIAN, AS SHOWN ON ON THE EAST SIDE OF CITRUS AVENUE. TR. NO. 15908, FILED IN BOOK 271, PAGES 4 THROUGH 39 OF MAPS, WAS USED ELEVATION: # 1467.59 rS THE BASIS OR BEARINGS FOR THIS MAP. CONSTRUCTION NOTES: la— INSTALL 8" EXTRA STRENGTH V.C.P. SEWER. 2a— CONSTRUCT PRECAST CONCRETE MANHOLE PER CITY OF FONTANA STD. DWG. NO. 112 (ID=48"). 4O— INSTALL 4" EXTRA STRENGTH V.C.P. SEWER LATERAL PER CITY OF FONTANA STD. DWG. NO. 125. SEWER LATERAL TABLE LOT # DESIGN STA. AS—BUILT STA. BACKFLOW 34 10+63 SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT. NO 35 11+57 i NO 36 11+77 NO 37 12+88 YES 38 13+08 NO 39 14+22 NO 40 14+44 NO 41 14+41 NO 42 14+15 NO 43 13+ 11 NO 44 12+91 YES 45 11+80 NO 46 11+60 NO 47 10+57 NO REV. REVISION DESCRIPTION DATE ENGR. CITY DATE SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT. Q��v �� de �rCFy C No. 65195 �° ° o * � `' � ,p Expl 9-30-05 tiP gTeCIV1�-O�`' OFCgLiF Prepared Under The Supervision Of : PREPARED IN THE OFFICE OF MADOLE AND ASSOCIATES, INC. 10601 CHURCH STREET, STE. 107 RANCHO CUCAMONGA, CA 91730 PHONE (909) 948-1311 —Date-t�. CITY OF FONTANA, CALIFORNIA i RECORD DRAWING n 1/b• SEWER IMPROVEMENTS PLANS BY - DRAG CC MJG TRA CT .n 16363 7 NICHT STAR CT DESIGNED BY: MJG/LP CH BY: MJG/LP PP OVED BY: RCE 65195 EXP. 9-30-05 ITY ENGINEER . 5115 DATE SCALE: 1 "=40' DATE: NOV. 2003 DRAWING NO.: 7 3439 8 J:\685-1650\sewer\sewO7.dwg, 04/29/2004 12:16:43 PM, cc