Loading...
HomeMy WebLinkAbout3410-1GENERAL NOTES 1 ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED. 2 WHEN A TECHNICAL CONFLICT 1S FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK". THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION. 3 ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER. 4 ADVANCE CONSTRUCTION SIGNING INDICATING DURATION OF PROJECT SHALL BE IN PLACE ONE WEEK PRIOR TO IMPLEMENTING DETOURS. 5 CONSTRUC77ON PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINA77ON SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK /N PUBLIC RIGHT—OF—WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 6 THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NDN—METRIC EDITION UNLESS OTHERWISE DIRECTED BY 7HE CITY 7RAFFIC ENGINEER. 7 /T SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES. 8 THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES -5 FEET OR GREATER /N DEP7H FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. 9 THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT. 10 NO MATERIAL OR EQUIPMENT SHALL BE STORED IN 7HE PUBLIC RIGHT OF WAY W17HOUT OBTAINING A SEPARATE PERMIT FOR 7HAT PURPOSE. 11 7HE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING U77LI77ES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE 7HERET0. 7HE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION. 12 774E CONTRACTOR SHALL COORDINATE CONSTRUCTION W1774 ALL U77LITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES. 13 THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS. 14 STATION/NG REFERS TO 7HE CENTERLINE OF STORM DRAIN EXCEPT WHERE OTHERWISE NOTED. 15 ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION. 16 7HE CONTRACTOR SHALL NOT DISTURB EXIS77NG SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER. 17 REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS 7HAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS'CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT. 18 THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES A MIN/MUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL 77MES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 19 THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFEC77VE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES. 20 THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL. 21 NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 22 A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE—WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY 1S OBTAINED. 23 CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS UPON INSPEC77ON OF 7HE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON—ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS. 24 ALL EXPOSED CONCRETE SURFACES SHALL CONFORM /N GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE 25 NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE CITY ENGINEER. 26 PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVA7ION AND LOCATION OF CONNECTIONS CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS. 27 1F EXISTING U77LI77ES OR ANY 07HER FACIL177ES CONFLICT WITH THE PROPOSED IMPROVEMENTS, 7HE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY. 28 NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. 29 ALL UNDERGROUND U77LI77ES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS. 30 APPROVED SOIL STERILANT 1S REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT. 31 ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING. J2 UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER. 33 AS—BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER. 34 MIN/MUM D—LOAD FOR STORM DRAIN PIPE IS 1350. INDEX MA P SCALE. 1 " = 100' CITY OF FONTANA UTILITY NO TIFICA TION LIST CITY OF FONTANA PACIFIC BELL CO. ATTN: CARLOS NAVARRO ATTY. VIRGINIA BECKER 8353 SIERRA AVENUE 3939 E.CORONADO STREET FONTANA, CA 92335 ANAHEIM, CA 92807 (909) 350-6632 (714) 666-5467 SO. CALIFORNIA GAS COMPANY COMCAST (CABLE TV) ATTN. GREG GASPAR ATM. JACK HAYES 16231 VALLEY BLVD. 1205 DUPONT AVENUE FONTANA, CA. 92335 ONTARIO, CA. 91761 o (909) 390-4738 EMERGENCIES4 (800) 427-2200 FINISH SURFACE G.B. GENERAL TELEPHONE COMPANY SO. CALIFORNIA EDISON COMPANY ATTN. STEVE HOCK 7951 REDWOOD AVE. 1400 E. PHILLIPS BLVD. FONTANA, CA. 92335 ONTARIO, CA. 91766 (909) 820-5598 - UNDERGROUND (800) 422-4133 (909) 875-5100 - TRANSMISSIONS (213) 637-1233 - PIPELINES FONTANA WATER COMPANY (909) 357-6233 - DISTRIBUTION ATTN: MICHAEL J. McGRAW (800) 422-4133 8440 NUEVO AVENUE FONTANA, CA 92335 CRAWFORD CANYON MUTUAL WATER CO. (909) 822-2201 ATTN. BILL VANDERKIEFT, ✓R. FAX. (909) 823-5046 (619) 868-6040 UNDERGROUND SERVICE ALERT (800) 227-2600 R/W 5'12' P. U. E. 0.5' CONC. J SIDEWALK EXIST. CONC. CURB & GUTTER 18' 50' CL 0.03' LEVEL LINE 2% 0.01' 50' R/W R/W 18' 7' 5' P. U. E. 6' L' AC PAVEMENT 29; TYPICAL SECTION K/NGSMILL COURT NOT TO SCALE T.1.=5.5 64' 20' CL LEVEL LINE 2% 20' -AC PAVEMENT 23" 64R/W TYPICAL SECTION MEDINAH STREET NOT TO SCALE T.1.=6.5 PRIVATE ENGINEER'S NOTICE TO CONTRA C TORS THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS; TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE DRAWINGS THE CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND RESPON- SIBILITY FOR THE UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN OR NOT SHOWN ON THESE DRAWINGS. THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONS IBILITY FOR THE JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION J OF THIS PROJECT; INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT vv THIS SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL REPORT ALL DISCREPANCIES TO THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK. e_j L CONC. SIDEWALK CONC. CURB & GUTTER R/W 12' 5' P. U. E. 6.5' 5' 0.5' 2� EXIST. CONC. CURB & GUTTER CONC. SIDEWALK VICINITY MAP SCALE. 1 " = 2000' CONS TRUC TION NOTES O1 INSTALL 24" RCP, D—LOAD PER PROFILE 2O CONSTRUCT MANHOLE PER A.P. W.A. STD. 321-1 3O REMOVE PORTION OF EXISTING SD LINE AND MH STRUCTURE RECORD DRAWING THESE RECORD DRAWINGS NAVE M14 PREPARED, IN PART, ON THE BAM OF INFORMATION COMPILED AND FURNISHED BY OTHERS. THE ENMNEER WILL NOT 8'E RESPONSNU FOR ANY ERAM OR 01101I881ON8 WHICH HAVE BEEN INCOlIPOIMITED WM THE DOCUMENTS AS A RESULT TMEREOF. - 1:1 SLOPE OR GREATER / OR ADEQUATE SHORING B. V. C. MPACTED B. W. NATIVEOBACKFILL 3' MAX. SIZE GRANULAR BEDDING FROM CATCH BASIN SELECTED TRENCH SIDE CENTERLINE MATERIAL (1 " MAX. SIZE). j END CURVE E.P. EDGE PAVEMENT III N EDGE GRADE Lo III END VERTICAL CURVE o FLOW LINE ND AV QUANTITIES 190 LF 1 EA 84 LF/1 EA NOTES. 1. TRENCH WIDTH SHALL BE CONTROLLED TO TOP OF PIPE ZONE. 2. TRENCH DEPTHS OF GREATER THAN 5' SHALL HAVE ADEQUATE SHORING. = I I 1 J. CLASS If AGG BASE ALL TRENCHES 6" MIN. I I I = LESS THAN 100' IN LENGTH. III NOTE: III -j COMPACTION SHALL BE 90.X IN ALL m ZONES UNLESS OTHERWISE SPECIFIED. TRENCH STABILITY SHALL CONFORM o TO CAL -OSHA REQUIREMENTS. R �m STORM DRAIN PIPE 0.6'0' l i e l l- GRANULAR BEDDING FROM SELECTED TRENCH SIDE MATERIAL FOR PIPE 10' OR GREATER IN DEPTH USE 1/2 CRUSHED STONE BEDDING. RCP TRENCH DETAIL NOT TO SCALE A.C. ASPHALTIC CONCRETE B. C. BEGIN CURVE B. V. C. BEG. VERTICAL CURVE B. W. BACK SIDEWALK C.B. CATCH BASIN C.L. CENTERLINE E.C. END CURVE E.P. EDGE PAVEMENT E. G. EDGE GRADE E.V.C. END VERTICAL CURVE F.L. FLOW LINE F.S. FINISH SURFACE G.B. GRADE BREAK H.P. HIGH POINT INV. INVERT O.C. ON CENTER P.C.C. PORTLAND CEMENT CONCRETE (R) RIDGE LINE R/W RIGHT OF WAY TAN. TANGENT T. C. TOP OF CURB W WIDTH V VERTICAL DEPTH (590.77) INDICATES EXISTING ELEVATION 590.77 INDICATES PROPOSED ELEVATION INDICATES SLOPE > 4 : 1 AC PAVEMENT ® REMOVAL ® GRIND SIERRA LAKES SPECIFIC PLAN 1 lW_17'A-A.t--lgnnl a— owAr. ooa os:zaoa nM. w