HomeMy WebLinkAbout3407-10
0
0
0
a-
GENERAL NOTES
1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF
FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE
STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN
BOOK'. ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE
LATEST EDITION UNLESS OTHERWISE NOTED.
2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT
DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE
PROVISIONS IN THE 'GREEN BOOK , THE CONTRACTOR SHALL IMMEDIATELY
REPORT SAID CONFLICT THE CITY ENGINEER FOR RESOLUTION.
3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE
CITY ENGINEER.
4. ADVANCE CONSTRUCTION SIGNING INDICATING DURATION OF PROJECT
SHALL BE IN PLACE ONE WEEK PRIOR TO IMPLEMENTING DETOURS.
5. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF
FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION
PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL
BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF
ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL
(909) 350-7610.
6. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES,
METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA
MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS
OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER.
7. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN
BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL
TIMES.
8. THE CONTRACTOR SHALL OBTAIN A PERMIT' TO PERFORM EXCAVATION
OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM
THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
9. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5)
FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE
GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS
OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA.
TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN
THE POTENTIAL EXISTS FOR GROUND MOVEMENT.
10. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC
RIGHT OF WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT
PURPOSE
11. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM
AVAILABLE INFORMATION, HOWEVER, R SHALL BE THE RESPONSIBILITY OF
THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND
THE ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER
PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL
CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO
WORKING DAYS BEFORE EXCAVATION.
12. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY
COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC,
CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER,
RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS.
ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE
PRIOR TO WORK AROUND THEIR FACILITIES.
13. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR
WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION.
CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY
FOR VALVE OPERATION AND WATER REQUIREMENTS.
14. STATIONING REFERS TO THE CENTERLINE OF STORM DRAIN EXCEPT
WHERE OTHERWISE NOTED.
15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SEI BY THE
ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO
THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE
PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING
DURING CONSTRUCTION.
16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS,
MONUMENT TIES OR BENCHMARKS WITHOUT PRIOR NOTIFICATION TO THE
CITY ENGINEER.
17. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING
SURVEY MONUMENTS, MONUMENT TIES AND BENCHMARKS, SHALL BE DONE
BY A REGISTERED CML ENGINEER OR LICENSED LAND SURVEYOR.
SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS
CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY
THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO
MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE
MONUMENT.
18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS
AND BUSINESSES AT ALL TIMES, A MINIMUM 12 FOOT LANE SHALL BE
MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS
AND EMERGENCY VEHICLES.
19. THE CONTRACTORS SHALL PROVIDE AND MAINTAIN AN EFFECTIVE
MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES.
20. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD,
SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY
ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR
WRITTEN APPROVAL
21. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL
OF THE CITY INSPECTOR.
22. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION.
FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING
OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS
OBTAINED.
23. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES
FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE
SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE
SWALES ENTERING OR LEAVING IMPROVEMENTS.
TOLL FREE 1-800-227-2600
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
REV.
24. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE,
COLOR AND FINISH TO MATCH EXISTING CONCRETE
25. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY
WITHOUT PRIOR APPROVAL OF THE CITY ENGINEER.
26. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING
FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY
APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY
CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS.
27. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE
PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER
AND ALL AFFECTED AGENCIES IMMEDIATELY.
28. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING
STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED.
29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND
APPROVED PRIOR TO PAVING OF STREETS.
30. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT
PAVEMENT PRIOR TO PLACEMENT.
31. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL
BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON
COMPLETION OF PAVING.
32. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE
ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL
DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER.
33. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO
THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO
THE CITY ENGINEER.
34. MINIMUM D -LOAD FOR ALL RCP IS 1350.
CITY OF FONTANA. UTILITY NOTIFICATION UST
CITY OF FONTANA
S.B.C. INC.
8353 SIERRA AVENUE
3939 E CORONADO STREET
FONTANA, CA 92335
ANAHEIM, CA 92807
(909) 350-6632
(714) 666-5500
SO. CALIF. GAS COMPANY
UNDERGROUND SERVICE ALERT
1981 W. LUGONIA AVENUE
(800) 422-4133
REDLANDS, CA 92374
E90 335-747
PACIFIC BELL CO.
MERGENCIES: (800) 427-2200
3939 E. CORONADO STREET
ANAHEIM, CA 92807
SO. CALIF EDISON COMPANY
(714) 666-5467
300 N. PEPPER AVENUE
RIALTO, CA 92376
VERIZON (TELEPHONE)
909 820-5598 - UNDERGROUND
1400 E. PHILIPS BLVD.
909 875-5100 - TRANSMISSION
ONTARIO, CA 91766
213 637-1233 - PIPELINES
(800) 422-4133
909 357-6505 - DISTRIBUTION
800 422-4133
FONTANA WATER COMPANY
ATTN: MICHAEL J. McGRAW
ADELPHIA (CABLE TV)
8440 NUEVO AVENUE
1500 S. AUTO CENTER DRIVE
FONTANA CA 92235
ONTARIO, CA 91761
(909) 822-2201
(714) 666-5500
FAX: (909) 823-5046
LEGEND
-440- DIRECTION OF FLOW
-o STREET LIGHT
- - - - HGL (HYDRAIJC GRADE UNE)
INV INVERT ELEVATION
PH POT HOLE ELEVATION
BC/EC . BEGIN CURVEIEND CURVE
BTM BOTTOM
- - - - RIGHT OF WAY
CITY OF FONTANA
TRACT N0. -16477
STORM DRAIN IMPROVEMENT PLANS
i
Z
IQ
CARNATION _ �!
UL
LJ
i m
STREET I
i
I
I
i
® � II
PRIVATE ENGINEERS NOTICE TO CONTRACTOR:
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES AND OR STRUCTURES
SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS.
THESE LOCATIONS ARE APPROXIMATE AND SHALL BE CONFIRMED BY THE CONTRACTOR,
SO THAT ANY NECESSARY ADJUSTMENT CAN BE MADE IN ALIGNMENT AND/OR GRADE
OF THE PROPOSED IMPROVEMENT. THE CONTRACTOR IS REQUIRED TO TAKE DUE
PRECAUTIONARY MEASURES TO PROTECT ANY UTILITY LINES SHOWN AND ANY OTHER
LINES NOT ON RECORD OR NOT SHOWN ON THESE PLANS.
CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED
CONSTRUCTION PRACTICES, HE WILL BE REQUIRED TO ASSUME
SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE
OF CONSTRUCTION OF THE PROJECT, INCLUDING THE SAFETY OF ALL PERSONS AND
PROPERTY. THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND
NOT BE LIMITED TO NORMAL WORKING HOURS. CONSTRUCTION CONTRACTOR FURTHER
AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY
AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF
WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE
OF THE DESIGN PROFESSIONAL
UNAUTHORW CHANGES AND USES-
THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR OR LIABLE
FOR, UNAUTHORIZED CHANGES TO OR USES OF THESE PLANS. ALL CHANGES TO THE
PLANS MUST BE IN WRITING AND MUST BE APPROVED BY THE PREPARER OF THESE PLANS.
REVISION DESCRIPTION
DATE I ENGR.I CITY I DATE
SHOULD CONSTRUCTION OF REQUIRED
IMPROVEMENTS NOT C0hVAENCE WITHIN
TWO YEARS OF THE DATE OF APPROVAL
SHOWN HEREON AND CARRIED FORTH IN A
DILIGENT MANNER, THE CITY ENGINEER MAY
REQUIRE REVISIONS TO THE PLANS TO ,
BRING THEM INTO CONFORMANCE WITH
CONDITIONS AND STANDARDS IN EFFECT
y� EIIINANL)A VINl-YAYU IKAC.I
A70MB. 17129
AM OtZ2&19M
INDEX MAP
SCALE: 1`_80'
BASIS OF BEARINGS:
BEARINGS ARE BASED ON THE SOUTH LINE OF THE SOUTHWEST ONE QUARTER OF
SECTION 36, T. 1 N., R. 6 W., S.B.B. & M. ALSO BEING THE CENTERLINE OF BASELINE
AVENUE BEING NORTH 89'58'21" WEST AS SHOWN ON TRACT 16085-1, RECORDED IN
MAP BOOK 282, PAGES 16-20, RECORDS OF SAN BERNARDINO COUNTY.
BENCHMARK
PREPARED FOR:
CITY OF FONTANA BENCHMARK NO. 361.
YOUNG HOMES
10370 TRADEMARK STREET RAILROAD SPIKE IN NORTH FACE OF POWER POLE
RANCHO TRADEMARK
STREET
NO. 1536697E AT THE SOUTHWEST CORNER OF
CA 917CUCAM SULTANA AVENUE AND BASELINE AVENUE.
(909) 291-7600
ELEVATIOI�L• 1365.01
WAM a
A
PROJECT
LOCATION
VICINITY MAP
N.T.S.
CONSTRUCTION NOTES ESTMTE OF QUANT111ES
E31 INSTALL 36' RCP (1350-D) 274 L.F.
2 INSTALL 30" RCP (1350-D) 62 L.F.
INSTALL 24" RCP (1600-D) 652 LF.
4 CONSTRUCT MANHOLE PER A.P.WA STD PLAN 322-1, PER DETAIL ON SHEET 4 1 EA
5 CONSTRUCT JUNCTION STRUCTURE PER A.P.WA STD PLAN 340-1, PER DETAIL ON SHEET 4 2 EA
6 REMOVE EXISTING BRICK AND MORTAR PLUG 3 EA
7 JOIN EXISTING PIPE 3 EA
8 CONSTRUCT MANHOLE PER A.P.WA STD PLAN 321-1, PER DETAIL ON SHEET 4 1 EA
SAWCUT, REMOVE & REPLACE EXISTING AC PAVEMENT PER CITY DWG NO. 131 925 SF
CONCRETE ENCASEMENT
SCALE: 1'_ V
GRANULAR BEDDING FROM SELECTED
TRENCH SIDE MATERIAL (1 " MAX SIZE)
GRANULAR BEDDING FROM SELECTED
TRENCH SIDE MATERIAL FOR PIPE 10'
OR GREATER IN DEPTH USE 1/2
CRUSHED STONE BEDDING
r _ Prepared By:
0 ALLARD ENGINEERING
F0Civil Engineering - Land Surveying - Land Planning
8253 Sierra Avenue
Fontana, California 92335
(909) 356-1815 Fax (909) 356-1795
- -----_ 2 - I Z - O
David S. Hammer, A.C.E. 43976 Date
(expires 6/30/2005)
!4 REBAR LONGIT.
4 READ)
3/4:1 SLOPE OR GREATER
OR ADEQUATE SHORING
90% COMPACTED NATIVE
BACKFILL 3' MAX SIZE-)
6' MIN.
8
i; r
_-_, \� I � I
STORM DRAIN--/
TRENCH DETAIL
NTS
Q�pFESS/C�
S. H.1
z
No. 43976 m
* Exp. 6/30/05
civil-
0
iAIL0 CA 01
LU
a
a
DRAWN BY:
AE
DESIGNED BY:
EI
CHECKED BY:
MI ('(
RECORD_ DOCUMENT
These Record Documents have been prepared
based on information provided by others. The
Design Professional has not verified the accuracy
and/or completeness of this information and shall
not be responsible for any errors or omissions
i may be incorporated herein as a result
DATE
w No.4 Z
C,i
NOTES:
1. TRENCH WIDTH SHALL BE CONTROLLED
TO TOP OF PIPE ZONE
2. TRENCH DEPTHS OF GREATER THAN 5'
SHALL HAVE ADEQUATE SHORING
3. CLASS II AGGRkGATE BASE ALL TRENCHES
LESS THAN 100 FEET IN LENGTH
NOTE:
COMPACTION SHALL BE 90Z IN ALL ZONES
UNLESS OTHERWISE SPECIFIED. TRENCH STABILITY
SHALL CONFORM TO CAL -OSHA REQUIREMENTS
CITY OF FONTANA CALIFORNIA
RANCHO FONTANA SPECIFIC PLAN
TRAF No. 64%7 SCALE: AS NOTED
ORM D NIM VEIVIENT PLAN DATE:
FEBRUARY, 2004
P ROVED DRAWING NO.:i
CITY ENGINEER R.C.E. 51152 3W 4
Filename: M:\DWG\15910\STORM\15910sd01.dwg
6'
TYP
;�,
-III
�_)
�-
#4 TIE BAR I=
�`
O Q • �:. - _
=� _ ♦_ .
24" O.C.
30 CLR
TYP
CONCRETE ENCASEMENT
SCALE: 1'_ V
GRANULAR BEDDING FROM SELECTED
TRENCH SIDE MATERIAL (1 " MAX SIZE)
GRANULAR BEDDING FROM SELECTED
TRENCH SIDE MATERIAL FOR PIPE 10'
OR GREATER IN DEPTH USE 1/2
CRUSHED STONE BEDDING
r _ Prepared By:
0 ALLARD ENGINEERING
F0Civil Engineering - Land Surveying - Land Planning
8253 Sierra Avenue
Fontana, California 92335
(909) 356-1815 Fax (909) 356-1795
- -----_ 2 - I Z - O
David S. Hammer, A.C.E. 43976 Date
(expires 6/30/2005)
!4 REBAR LONGIT.
4 READ)
3/4:1 SLOPE OR GREATER
OR ADEQUATE SHORING
90% COMPACTED NATIVE
BACKFILL 3' MAX SIZE-)
6' MIN.
8
i; r
_-_, \� I � I
STORM DRAIN--/
TRENCH DETAIL
NTS
Q�pFESS/C�
S. H.1
z
No. 43976 m
* Exp. 6/30/05
civil-
0
iAIL0 CA 01
LU
a
a
DRAWN BY:
AE
DESIGNED BY:
EI
CHECKED BY:
MI ('(
RECORD_ DOCUMENT
These Record Documents have been prepared
based on information provided by others. The
Design Professional has not verified the accuracy
and/or completeness of this information and shall
not be responsible for any errors or omissions
i may be incorporated herein as a result
DATE
w No.4 Z
C,i
NOTES:
1. TRENCH WIDTH SHALL BE CONTROLLED
TO TOP OF PIPE ZONE
2. TRENCH DEPTHS OF GREATER THAN 5'
SHALL HAVE ADEQUATE SHORING
3. CLASS II AGGRkGATE BASE ALL TRENCHES
LESS THAN 100 FEET IN LENGTH
NOTE:
COMPACTION SHALL BE 90Z IN ALL ZONES
UNLESS OTHERWISE SPECIFIED. TRENCH STABILITY
SHALL CONFORM TO CAL -OSHA REQUIREMENTS
CITY OF FONTANA CALIFORNIA
RANCHO FONTANA SPECIFIC PLAN
TRAF No. 64%7 SCALE: AS NOTED
ORM D NIM VEIVIENT PLAN DATE:
FEBRUARY, 2004
P ROVED DRAWING NO.:i
CITY ENGINEER R.C.E. 51152 3W 4
Filename: M:\DWG\15910\STORM\15910sd01.dwg