Loading...
HomeMy WebLinkAbout3402LT-1GENERAL NOTES: IALL WORK, MATERIAL AND EQUIPMENT TO BE FURNISHED AND INSTALLED BY THE CONTRACTOR SHALL CONFORM TO EDISON COMPANY REQUIREMENTS, AND SHALL BE APPROVED BY EDISON CO. PRIOR TO INSTALLATION. 2. THE LOCATION OF THE PROPOSED CONDUIT SYSTEM IS APPROXIMATE, EXACT CONDUIT AND HANDHOLE LOCATIONS SHALL BE COORDINATED WITH EDISON CO. PLANNER AND SHALL BE INSTALLED PER EDISON CO, REQUIREMENTS. 3. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO CONTACT THE EDISON SERVICE PLANNER, GREGORY KLOCK AT(909) 357-6585 AT LEAST 30 DAYS IN ADVANCE FOR COORDINATION OF CONSTRUCTION 4. NEW HANDHOLE AND CONDUIT WITH PULLROPE, AS SHOWN HEREON, SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR. NEW ELECTROLIER, FOUNDATION, AND WIRING SHALL BE FURNISHED AND INSTALLED BY EDISON CO. ELECTROLIERS ARE SHOWN HEREON FOR REFERENCE ONLY. 5. ON STREETS WHERE THE SIDEWALKS ARE FIVE FEET OR LESS IN WIDTH AND ADJACENT TO CURB, THE STREET LIGHTING CONDUIT RISERS AND THE PROPOSED ELECTROLIERS SHALL BE PLACED AT THE BACK OF THE SIDEWALK, UNLESS OTHERWISE INDICATED ON PLAN. COORDINATE EXACT LOCATIONS WITH EDISON CO. 6. EXACT FIELD LOCATIONS OF THE PROPOSED STREET LIGHTING RISERS SHALL CONFORM, WHERE PERMITTED, TO THE AMERICANS WITH DISABILITIES ACT (ADA) REQUIREMENT. 7- ALL STREET LIGHTS SHALL BE INSTALLED PER CITY OF FONTANA STREET LIGHTING STANDARD DRAWING 1016. 8. AS FUTURE NEW PRIVATE DEVELOPMENT OCCURS ALONG EITHER SIDE OF SOUTH HIGHLAND AVENUE THE STREET LIGHTING ON EXISTING WOOD POLES SHALL BE REPLACED WITH ORNAMENTAL POLES (MARBELITES) AND THE OVERHEAD WIRES SHALL BE UNDERGROUND. CITRUS AVENUE CURB 6 I Iii• HH -79D TO S.L.*051E ,.., 1 $ 0, 6 552051E \\ T 7' CONC. ELECTROLIER I,, -V 8' MAST ARM ' 22000 H.P.S.V. \I \ V) E !i'� rF � f W W W �I ---0. a 4 ) 9 'it _ 41 — — 42 — RAISED F `\\ MEDIAN ` CURB t� CURB I I� CITRUS AVENUE I t,�rw RIGHT OF WAY CONSTRUCTION NOTES : (STREET LIGHT CONDUIT) 14 INSTALL STREET LIGHT 22.000 LUMEN PER CITY OF FONTANA STD. PLAN N0. 1016 (BY SCE). 67 INSTALL NEW 101/2' X 17' X 12' CONCRETE VAULT FOR SCE BY CONTRACTOR 68 INSTALL CONDUIT RUN FOR SCE BY CONTRACTOR AS SHOWN BELOW NO. OF CONDUIT PROPOSED CONDUIT RUN FOR 1 3 SIZE OF CONDUIT (INCHES) ANY SYMBOLS FOLLOWED BY STREET LIGHT WITH DETAILS210, DENOTED THE FOLLOWING, AND DEPT+1 36' MIN. DB CONDUIT WITHOUT ENCASEMENT IS LENGTH OF CONDUIT RUN (FEET) ACCEPTABLE FOR PORTIONS OF TRENCH WITH ONLY ON OR 1WO CONDUITS. SEMI -ENCASEMENT IS REQUIRED FOR PORTIONS OF TRENCH WITH ONLY THREE OR FOUR CONDUITS. FULL ENCASEMENT IS REQUIRED FOR MORE THAN FOUR CONDUITS. ANY SYMBOLS FOLLOWED BY LEGEND DENOTEDTHE FOLLOWING 9-U■ PROPOSED STREET LIGHT ON 30' MARBLELITE POLE AND 8' MAST ARM (22, 000 LUMEN HPSVj 200 WATTo *20) 4- Q EXISTING SAFETY LIGHTS TR R UIO 1/2' X 17' X 12' CONC'. HANDHOLE *HH -79E STA. 49+49 6 0 1/2' X 17' X 12' CONC. 4552053E 40 60 80 100 STA. 47+22.5 4552057E SCALE: 1'=40' 27' CONC. ELECTROLIER 27' CONC. ELECTROLIER 8' MAST ARM 6,� * 8' MAST ARM PLANS PREPARED BY: N .. 22000 H.P.S.V. ,• O F O N T A N A HH -79D TO SL055E I .. " I:• 22000 H.P.S.V. 6 �y y0 90, I Iii• LIGHTING PLAN 6 * 405 * HH -79H TO S.L.*059E Industry, CA 91746-3497 (562) 906-6200 � i HH -79D TO S.L. 053E 1'Z. HIGHLAND AVENUE SCALEI I • =40' 4552055E HH -79E TO S.L.*057E6 I I • 54• DESIGNED BY` °v15/2o04 27 CONC. ELECTROLIER 121'92' 8' MAST ARM I. /•Q4 CHECKED BYs VED B /L _ [ HANDHOLE *HH -79D 14 22000 H.P.S.V. I4 14 4552059E 14 3402LT 6 10 1/2'X 17'X 12' CONC. CITY ENGIN ER R.C.E 51152 DATE: CURB 8' MAST ARM LI %D STA. 43+90.5 rn RAISED rn r 22000 H.P.S.V. M v MEDIAN �+ 0 CURB v I F N N C _ - ■ ■ L.f � CV W _ __.. 4,, . _ ,_. __. _ _ ._ W__ _ _ _ _ N W _.._._ _ _ . �_ _ _ _ _ — ._ — .— tN _ _ _ �r _ -- W -- W W �— W' W W -- W W F_ F— — 'IT— — — LLJ 3 _ ---'' N 433 1-3' RISER z W 79 H 1.11551bVJ PP*4337879E N _ _—SIA -47—+26— _ �„�_._--.....— �--� a __ _ _ — ■ I n+ + In In + cn Q M QQ Q HIGHLAND ti AVENUE N 1�4 14 14 � 14 68 13. CURB 68 13. 6 1 8 3, �E HH -79F TO HH -79G RIGHT OF WAY HH -79A TO HH -79B HH -79A TO HH -79F 179' :CTROLIER ITT' 234' 4552054E V. 4552058E 67 HANDHOLE *HH -79C g7MASTC RLMEC OLIE 68 I 3' 27' CONC. ELECTROLIER 68 1 1�=• 0 1/2 X 17 X 12 CONC. 22000 H.P.S.V. HH -79A TO HH -79E , HH -79C TO S.L.*052E 61, STA. 43+90.5 * 8' MAST ARM 100 iE 22000 H.P.S.V. i * HH -79B TO HH -79C 68 I 3m HH -79B TO S.L.*054E68 I I��=6 ANDHOLE *HH -79A 68 13. STA47+225 167 20 0 1/2' X 17' X 12' CONC68 . HH -79E TO S.L.*058E1_ �'_• . . HANDHOLE *HH -79B 0 1/2' X 17' X 12' CONC. STA. 45+50 HH -79A TO S.L.*056E6 11�=• 20' 4552056E HH -79C TO HH -79D REV. Im DIAL TWO WORKING BEFORE n DAYS BEFORE YOU DIG YOU DIG TOLL FREE 1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT REVISION DESCRIPTION 27' CONC. ELECTROLIER 8' MAST ARM 22000 H.P.S.V. DATE ENGR.CITY DATE ?✓ �.�� SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH STANDARDS IN EFFECT. NDHOLE *HH -79F rt 00 rn Q I— V) I L1J z L1J Q z Q CD z 0 N s UIO 1/2' X 17' X 12' CONC'. STA. 49+49 20 10 0 20 40 60 80 100 SCALE: 1'=40' PLANS PREPARED BY: N .. CITY ,• O F O N T A N A QROFESS�pN GLutxX ��% V1/ILLDAN �y y0 \/i/ STREET LIGHTING PLAN �� Q 13191 Crossroads Parkway North, Suite 405 Industry, CA 91746-3497 (562) 906-6200 DRAWN BY: VM/LT SOUTH HIGHLAND AVENUE SCALEI I • =40' No. 45729 DESIGNED BY` °v15/2o04 Exp. 12-31-06 * UNDER THE SUP RVI ION OF: CITRUS AV NU TO STA 51+00 `�gTFpFCA \ o���P I. /•Q4 CHECKED BYs VED B /L _ [ DRAWK ND.: I HERBERT GLUESING JR. R.C.E. 45729 HLG 3402LT 5 CITY ENGIN ER R.C.E 51152 DATE: rt 00 rn Q I— V) I L1J z L1J Q z Q CD z 0 N s