Loading...
HomeMy WebLinkAbout2769-57INSTALL ALL SLEEVES WITH 36" COV9M C H A S E R A D -NOTE: VALVE LOCATIONS NOTE: MAIN LINE IS 9'-0" 9 AND 10 ARE REVERSEDNOTE: SLEEVE CR SSING IS 15'-0" 2 NOTE: GATE VALVE LOCTATION OFF OF CURB AND GUTTER OFF CURB AND GU TER ►'21 l"7 �' � "!5 � 1'IS i 2 _ I • + �'� I" !� COW 1'- . , I Q r Ib NOTE: _ • NOTE: SLEEK 1 15'-0" AIN LINE RUNS - - - - -- - - OFF CURB A1QD�G 15 2 2'-0" VFF OF WALL I t j 2 2 " TOTAL I IG D AREA = 25,500 SOFT. Q NOTE: SLEEVE IS 13'-0' 1 4 y OFF OF BUILDING 2 i G Qr NOTE: ALL VALVES TEE OFF OF MAIN LINE 1 FIRE STATION AND SET 2'-0" OFF INSIDESIDEWALK GE NOTE: MAIN UNE RUNS - 4'-0" OFF OF WALL 2 1 - i - NOTE: EDGE OF BUILDING i NOTE: MAIN LINE RUNS (�- " 4'-0OFF OF SIDEWALK �, It _ o of NOTE: MAIN thiQE IS 9•-O" r. OFF OF CURB AND GUTTER so r M IO NOTE: FIRST VALVE IS 1S 5'-0 OFF BUILDING 2 a r - iti 1 I ? NOTE: IKAAIW i INE IS =0"' OFF OF--SIDEWALK2 'r 17 r • • r -- y �" Il4• NOTE: MAIN LINE IS 2'-0" OFF OF BUILDING AND CURB Ze Qr AND GUTTER NOTE: MAIN LINE RUNS j 6 2 r ( 2'-0" OFF OF BUILDING 2 NOTE: SLEEVE CROSSING IS 15'-0" 2 a EDGE �, `4' OFF CURB AND GUTTER M M CONTROLLER IN CAI -RBI -24 STAINLESS STEEL ENCLOSURE ASSEMBLY BY PTS. CONNECT CONTROLLER TO 110 VOLT ELECTRICAL SERVICE PROVIDED BY OTHERS. INSTALL (1) ORANGE COLORED SPAREWIRE ALONG THE ENTIRE LENGTH OF THE MAIN LINE. INSTALL PRESSURE COMPENSATING SCREENS IN ALL POP UP SPRAY HEADS; REFER TO MANUFACTURERS LITERATURE FOR SIZING FINISHED GRADE s. 6' MIN FROM HARDSCAPES 4 CLEAN BACK FILL SATURATE AND COMPACT TO 90% NON PRESSURE LATERAL UNE HARDSCAPING z _z TERAL UNE NATIVE BACKFILL 2" MINUS m PRESSURE SUPPLY UNE . NON PRESSURE LATERAL UNE W/SLEEVE ; CONTROLL WIRES : LEAN BACKFILL ~ PRESSURE SUPPLY LINE W/SLEEVE N CONTROL WIRE SLEEVE 1 I r:•`:r+ �` ��: SAND BACK FILL 6 2' MI "MIN 6. FINE GRANULAR MATERIAL WILL BE PLACED ON ALL LINES. NO LARGER THAN 1/2' INCH IN SIZE. THIS WILL BE PERMITTED IN THE MIN INITIAL BACKFILL MEASURED FROM THE TOP OF PIPE. THE REMAINDER TIS ES. OF TRENCH CAN BE FILLWITH ROCK SCREENED 2" MINUS. INSTALL CONTROL WIRE SLEEVE ADJACENT TO THE PRESSURE SUPPLY UNE SIZE PER ALL BACK FILL IS TO BE SATURATED AND COMPACTED TO 90% SPEC. INSTALL ALL PVC PIPE WITH `LABEL UP. ALL SLEEVES TO BE SCH. 40 PVC AND TO BE 2X THE DIAMETER OF THE UNE TO BE SNAKE ALL PIPE IN TRENCH. SLEEVED. BUNDLE AND TAPE ALL CONTROL WIRES AT 10' O.C. TO PRESSURE • INCREASE THIS DISTANCE TO 36' WHEN SLEEVING UNDER ROADWAYS AND COMMERCIAL SUPPLY UNE AND PROVIDE A SERVICE LOOP AT ALL 90 DEGREE TRAFFIC WAYS. CHANGES IN DIRECTION. SLEEVES SHALL BE EXTENDED BEYOND HARDSCAPE TO POINTS AS REQUESTED BY PRESSURE MAIN LARGE THAN 2" SHALL BE P.V.C. CLASS 315 INSPECTOR SMALLER THAN 2' SHALL BE P.V.C. SCHEDULE 40. IF SLEEVES ARE TO BE USED AT A LATER DATE, CONTRACTOR SHALL TAPE ENDS AND CONTRACTOR SHALL PROVIDE SLEEVES OR CONDUIT LINES WHEN PROVIDE A VERTICAL MARK AT ENDS OF SLEEVING VISIBLE ON GROUND LEVEL MAINLINE INSTALLATION IS UNDER ASPHALT OR CONCRETE. 44 l CONTRACTOR SHALL PROVIDE 24" INCHES OF COVER OVER PIPE SERVING A DRINKING FOUN-. AJN OR PRESSURE MAINLINE 3" AND LARGER. GATE OF LAST RLMSION: 9-14-98 DATE OF LAST REVISION: 9-14-98 ISVES3l APPROVED BY: tolEssp APPROVED BY: + CITY OF FONTANA ` a l CITY OF FONTANA UL Mas CITY ENGINEER DATE: CITY ENGINEER DATE RO1&RT W WEDDLE SLEEVING DETAIL Its. 25131 ROBERT W. WEDDLE TRENCHING DETAIL x L11. a/34/0 * W. 12/3+/m am RECOMMENDED BY: RECOMMENDED BY: +If a tills DRAWN my. TMAOTHY KA6TE17TSIO. DETAIL NO. 518 r���f OF Ltt1iDRAWN BY: TIMOTHY RASTEDT STO.'DETAIL NO. 515 PRESSURE INFORMATION OBTAINED FROM THE CITY OF FONTANA WATER DEPARTMENT. IKKIVAI IUN, •7CC I,IVIL r_N%. IrVtCKIN1_V UKhJ. STATIC PRESSURE 63 PS! _ PEAK IRRIGATION DEMAND 30 GPM " _ - _ CONTRACTOR SHALL VERIFY WATER PRESSURE PRIOR TO START OF IRRIGATION INSTALLATION. NOTIFY THE CONSULTANT IMMEDIATELY IF L VARIATIONS OF MORE THAN 5 PSI ARE FOUND. q • I ENCLOSURE ASSEMBLY WITH COMMERCIAL STRIPS,STRIPS, FAN AND UNIVkRSAL ADAPTER FOR REMOTE CONTROLSECURED ON CONCRETE FOOTING. COLOR CODED MAP FOR VALVE LOCATION INSIDE (SEE SPECS.) LOCK COVER COMMON WIRE SHALL BE TIED NSIDE HOUSING /z__ WHEN REQUIRED ON-OFF SWITCH TO BE PROVIDED j. BY CONTRACTOR CONCRETE FOOTING -INSTALL 3' MIN. ABOVE GRADE AND SLOPE CONCRETE AT 2% TO DRAIN FINISH GRADE ELECTRICAL CONDUIT TO SOURCE (CONTROL UNIT ELECTRICAL REOUIREMENTS: t IS volt. '• 60 cycle, 2 anps. MAXJ ELECTRICAL TAPE - TAPE WIRING AT NTERVALS OF I0'O C I COMMON WIRE TO ALL RCV S NOTES: I CONTROL WIRE TO EACH RCV L COMMON 147RE TO BE WHITE AND - CONTROL WRING (AWG IF. ♦ 111, SECURE TO CONTROL WINE TO BE BLACK N COLOR CONTROL UNIT AT TERMINALS PROVIDED N 2. NO SPUC£S SHALL BE MADE BETWEEN CONTROL OMIT - UNLESS OTHERWISE NOTED CONTROLLER AND REMOTE CONTROL VALVE 3. CONTROL WIRING SEOUENCE CORRESPONDS TO OPERATING SEOIIENCE OF REMOTE CONTROL VALVES AND AUTOMATIC SPRINKLER CONTROL LWT STATION CONNECTION ISEQUENCE SHOWN ON DETAIL IS FOR REFERENCE ONLY, SEE IRRIGATION PLAN FOR CORRECT VALVE SEOUENce ISOMETRIC ISOMETRIC i AUTOMA77C CONTROLLER IN ENCLOSURE ASSEMBLY- REMOTE CONTROL VALVE NO SCALENO SCALE FINISH GRADE IWTUL NSTALLATION O POP -LR' HEAD AFTER LOWERING (FNA ai.•ABOVE FNISHGRADE PVC LATERAL LINE DEL PGH sloEwALx, CURB, ETc O ARED ROTOR '-�, M��r •.� .. 3/4" STREET ELL i FAWSH i VC SCKf0 STREET ELBOW PVC TEE SCH. BO N VI.F; z O SLZE AHD LENGTH AS REOU11RED Uj a PVC TEE OR ELBOW SxSxT ` 3/4' SCHED NIPPLE o PYCscrl •o STREET ELBOW (LENGTH EOUIRED) LITERAL LINE Now- 3/ TREET ELLS USE TEFLON TAPE ON ALL THREADED FIT TNGS - -UP HEADP HI SCALE • 0 � cH GH POP Virginia Dare Tower 10470 Foothill Blvd. Rancho Cucamonga California 91130-3754 tel: 909 987 0909 fax: 909 9809980 CHRISTIE I.D. TAG---�--y tiZ5 '' w. MANUFACTURER �01ti� BOX TO BE PLACED.AT RIGHT ' CONNECT WIRES BY •0¢ ANGLES TO HARDSCAPE EDGE CRIMPING USING WIRE 1 ►AMT WMRE ARROW ON CURS NUTS AND SEALING " 1806SAIM-15 WITH PEN TITS WIRE CONNECTORS?. - �' • • + •x/ 12"x18" PLASTIC BOX AND /COVER WITH LOCK TOP FINISH GRADE LAWN A EA . MARKED: IRRIGATION CONTROL FINISH GRADE •:. • VALVE SHRUB AREA • NON PRESSURE LINE FITTING . T - . 111 .1Y�.R , CURL TYPE EXPANSION LOOP •. -. r:" I IMIN. 24 02.52 100 314' Cl. 315 Lateral Line 08.00 03.45 SB)EWALK, CURB. ETC. = 31.2,318.80 (GALLONSNEAR) ��• PVC LATERAL PIPE 12• POP UP 0.4 0.6 0.8 SOLENOID 10' ESTIMATED WATER USE: 0u1C9 COUPLMG VALVE ISEE SPECSJ .�•. FLOW ADJUSTMENT {' ~' = (56.6) (.80) (7,700.0) (.62) Station S: 18 Min. Re# by Head: 30.00 Z l�fa' !•" PEA GRAVEL (MIN. I Co. It.) ' Farthest System 6.0' Elevation Loss: 02.60 4' �� ----- PVC SCH. 80 MALE ADAPTOR TOTAL EMU = 528,485.52 (GALLONSNEAR) • PVC LINE PPE hM SCK 80 1806-SAM-I6H-SLA-P.CSO40 t,11 PRESSURE SUPPLY LIVE FITTNG ISEE SPECSJ $ yA1 f0=4 GRADE LA WN AREA FMISN GRADE, SHRUB AREAS COMMON WIRE TO CONTROLLER 1 ' • -f1175H GRADE; SMRUB MEAS CONTROLWIRE TO CONTROLLER BUBBLER 02 I• NOTE: 30 INSTALL CONTROL VALVES MIN. OF .(( 1 aft. APART IN SHRUB AREAS UNLESS STAMLESS STEEL CLAMP (3 PLACES) OTHERWISE NOTED ISOMETRIC ISOMETRIC i AUTOMA77C CONTROLLER IN ENCLOSURE ASSEMBLY- REMOTE CONTROL VALVE NO SCALENO SCALE FINISH GRADE IWTUL NSTALLATION O POP -LR' HEAD AFTER LOWERING (FNA ai.•ABOVE FNISHGRADE PVC LATERAL LINE DEL PGH sloEwALx, CURB, ETc O ARED ROTOR '-�, M��r •.� .. 3/4" STREET ELL i FAWSH i VC SCKf0 STREET ELBOW PVC TEE SCH. BO N VI.F; z O SLZE AHD LENGTH AS REOU11RED Uj a PVC TEE OR ELBOW SxSxT ` 3/4' SCHED NIPPLE o PYCscrl •o STREET ELBOW (LENGTH EOUIRED) LITERAL LINE Now- 3/ TREET ELLS USE TEFLON TAPE ON ALL THREADED FIT TNGS - -UP HEADP HI SCALE • 0 � cH GH POP Virginia Dare Tower 10470 Foothill Blvd. Rancho Cucamonga California 91130-3754 tel: 909 987 0909 fax: 909 9809980 CONC. WALK POP-UP SHRUB HEAD WALK OR CURB OR CURB 1 /2" FINISH GRADE FINISH GRADE SCH 80 PVC NIPPLE THREADED BOTH ENDS HI POP SHRUB HEAD %'P`VC STicccl ELLS _ L- PVC STREET ELL LATERAL LINE WITH PVC TEE OR ELL DOUBLE SWING JOINT NOTE: 2 EA. PVC STEET ELLS 0 INSTALL 12" SHRUB POP-UP HEAD 1 1/2" NOTE: ABOVE F.G. INSTALL HI -POP IRR. HEAD 1 1/2" ABOVE' F.G. O F.G. - 1 1/2" BELOW WALK OR CURB F.G. 1 1/2* BELOW HARDSCAPE DATE OF LAST REVISION: 9-14-98 DATE OF LAST REVISION: 9-14-9i5 APPROVED 13Y: CITY OF FONTANA1toiEsslp APPROVED BY: CITY OF FONTANA LAWN / 41161811 ` ^ NL bin ROBERT ENGINEER DATE: • ssl3t CITY ENGINEER DATE: ROBERT W. WEDDLE 5HRUS POP-UP HEAD ROBERT W. WEDDLE HI POP 5HKU13 HEAD * ora * RECOMMENDED BY: J�+I£B t1a11 \! REC01iMENDEO BY: DRAWN BY: TIMOTHY RASTEDT ETD. DETAIL NO.52x OWLf�*7 WL 11d8�' DRAWN BY: TIMOTHY IUSTEDT STD. DETAIL NO. 524 Irrigation Pressure Calculation MANUFACTURER PROJECT LANDSCAPE AREA: = 25,500.0 SQUARE FEET FONTANA FIRE STATION Static Pressure: 63.00 Apr -5-99 MAXIMUM WATER BUDGET: _ (ETO)_ (0.8) (AREA) Max. GPM Demand: 21.00 ►AMT WMRE ARROW ON CURS = (56.6) (0.8) (.59) Units Size Type Description GPM Unit PSI toss 1806SAIM-15 = 26.72 (ACREIINCHESNEAR) 3.7 90 VAN AW 360 IS PLASTIC BOX ANO COVER 1 2" Disc Water Meter 21.00 00.00 = 715,876.8 (GALLONSNEAR) 1 2' Reduc. Pressure BFP 21.00 09.00 RAINSIRD 9 ,, COVER YM KEIk /YUGADON ESTIMATED WATER USE: = (ETO) (KCIEi) (AREA) 1 1" Plastic Control Vain 21.00 03.20 650 2" Cl. 315 Main Line 21.00 PLANTER AREA = (56.6) (.50) (17,800.0) (.62) 02.52 100 314' Cl. 315 Lateral Line 08.00 03.45 SB)EWALK, CURB. ETC. = 31.2,318.80 (GALLONSNEAR) Misc Fittings Allowance 01.19 12• POP UP 0.4 0.6 0.8 1.6 90 VAN 180 360 10' ESTIMATED WATER USE: 0u1C9 COUPLMG VALVE ISEE SPECSJ Component Losses: 22.26 " ' J. = (56.6) (.80) (7,700.0) (.62) Station S: 18 Min. Re# by Head: 30.00 1806-SAM•18 QSLA PCS -020 '' Farthest System 6.0' Elevation Loss: 02.60 4' �� Total Pressure Rsq'r. 54.86 TOTAL EMU = 528,485.52 (GALLONSNEAR) • RAINSIRD 0 1806-SAM-I6H-SLA-P.CSO40 r r r f0aw GRADE LAWN AREAS - 4' yA1 f0=4 GRADE LA WN AREA FMISN GRADE, SHRUB AREAS ■ ' • -f1175H GRADE; SMRUB MEAS 1806SAm-ksT-B•PC5020 BUBBLER 02 I• 1.15' 30 .(( 1 HUNTER STAMLESS STEEL CLAMP (3 PLACES) ROUND,PLASTiC BOX AND COVER W 8 COVER MARKED: RRIGATION GATE SHRUB ROTOR 2 4,2 4,2 ADJ ADJ 351 LENGTH AS REQUIRED. S/!' BRASS NMPLE 0.62 g '4 GRISWOLD 0 2250 MASTER VALVE, PRESSURE REDUCING. p NAND WHEEL OR BRASS CROSS MAM E• �! A • E PRESSURE SUPPt r LINE fRTMG (SEE SPECS) RAINSIRD 0 PES PREssuxE SUPfLr LBE SU►/L r AM i s (SEE SPECSJ RAINBIRD 0 33 DLRC QUICKCOUPUNG VALVE. tr' BRASSNPfLE jam„ GATE VALVE. LINE SIZE. PEI GRAVEL WA 2 CU. FTJ WBRASS ELBOW L� RAINSIRD # i M CONTROLLER IN STAINLESS STEEL ENCLOSURE ASSEMBLY BY PTS • BRASS AWftE a ` f GATE VALVE CONTROLLER AND STATION NUMBER N 8 V2' G.tt V, PIE POST VALVE SIZE I GPM FLOW Pvc SCH. 10 MALE ADAPTER PVC . SCHEDULE 40 SLEEVE PEA GRA VEL Bet i CIL FTJ w PVC SCHEDULE 40 SPRINKLER LATERAL ISOMETRIC PVC SCHEDULE 40 IRRIGATION MAIN, 314' TO 1-1rY SIZE L$OMETRIC ` iri PVC QUICK COUPLING VALVE IRRIGATION MAIN, 2• AND 2-112' GATE VALVE NO SCALE NO SCALE CONC. WALK POP-UP SHRUB HEAD WALK OR CURB OR CURB 1 /2" FINISH GRADE FINISH GRADE SCH 80 PVC NIPPLE THREADED BOTH ENDS HI POP SHRUB HEAD %'P`VC STicccl ELLS _ L- PVC STREET ELL LATERAL LINE WITH PVC TEE OR ELL DOUBLE SWING JOINT NOTE: 2 EA. PVC STEET ELLS 0 INSTALL 12" SHRUB POP-UP HEAD 1 1/2" NOTE: ABOVE F.G. INSTALL HI -POP IRR. HEAD 1 1/2" ABOVE' F.G. O F.G. - 1 1/2" BELOW WALK OR CURB F.G. 1 1/2* BELOW HARDSCAPE DATE OF LAST REVISION: 9-14-98 DATE OF LAST REVISION: 9-14-9i5 APPROVED 13Y: CITY OF FONTANA1toiEsslp APPROVED BY: CITY OF FONTANA LAWN / 41161811 ` ^ NL bin ROBERT ENGINEER DATE: • ssl3t CITY ENGINEER DATE: ROBERT W. WEDDLE 5HRUS POP-UP HEAD ROBERT W. WEDDLE HI POP 5HKU13 HEAD * ora * RECOMMENDED BY: J�+I£B t1a11 \! REC01iMENDEO BY: DRAWN BY: TIMOTHY RASTEDT ETD. DETAIL NO.52x OWLf�*7 WL 11d8�' DRAWN BY: TIMOTHY IUSTEDT STD. DETAIL NO. 524 Irrigation Pressure Calculation MANUFACTURER PROJECT LANDSCAPE AREA: = 25,500.0 SQUARE FEET FONTANA FIRE STATION Static Pressure: 63.00 Apr -5-99 MAXIMUM WATER BUDGET: _ (ETO)_ (0.8) (AREA) Max. GPM Demand: 21.00 0 = (56.6) (0.8) (.59) Units Size Type Description GPM Unit PSI toss 1806SAIM-15 = 26.72 (ACREIINCHESNEAR) 3.7 90 VAN AW 360 IS = (56.6) (0.8) (25,500.0) (.621 1 2" Disc Water Meter 21.00 00.00 = 715,876.8 (GALLONSNEAR) 1 2' Reduc. Pressure BFP 21.00 09.00 RAINSIRD 9 1806SAM-10LA 1 1-112" Globe Master Valve 21.00 02.90 ESTIMATED WATER USE: = (ETO) (KCIEi) (AREA) 1 1" Plastic Control Vain 21.00 03.20 650 2" Cl. 315 Main Line 21.00 PLANTER AREA = (56.6) (.50) (17,800.0) (.62) 02.52 100 314' Cl. 315 Lateral Line 08.00 03.45 XS = 31.2,318.80 (GALLONSNEAR) Misc Fittings Allowance 01.19 12• POP UP 0.4 0.6 0.8 1.6 90 VAN 180 360 10' ESTIMATED WATER USE: = (ETO) (KCIEQ (AREA) . Component Losses: 22.26 TURF AREA = (56.6) (.80) (7,700.0) (.62) Station S: 18 Min. Re# by Head: 30.00 1806-SAM•18 QSLA PCS -020 = 216,166.72 (GALLONSNEAR) Farthest System 6.0' Elevation Loss: 02.60 4' 30 Total Pressure Rsq'r. 54.86 TOTAL EMU = 528,485.52 (GALLONSNEAR) R i RAINSIRD 0 1806-SAM-I6H-SLA-P.CSO40 es dual Pressure: 08.14 TOTAL EMU: = 73.8r/. OF MWB IRRIGATION LEGEND. SYMLtB4OLS MANUFACTURER ITEM GPM PATTERN R PSI I P.R. b 0 O RAINBIRD i 1806SAIM-15 6' POP UP 0.6 1.3 1.8 3.7 90 VAN AW 360 IS W 1.83 6 O )f RAINSIRD 9 1806SAM-10LA 6' POP UP 0.4N._ 0.6 0.8 1.6 90 VAN 180 360 IV 30 1.78 b 6 O XS RAINBIRD /I 1812 -SMA -PRS -I OL A 12• POP UP 0.4 0.6 0.8 1.6 90 VAN 180 360 10' 30 1.78 or RAINBIRD R 1806-SAM•18 QSLA PCS -020 SHRUB SPRAY 02 90 - • 4' 30 RAINSIRD 0 1806-SAM-I6H-SLA-P.CSO40 SHRUB SPRAY 0.4 180 4' 30 ■ RAINSIRD f 1806SAm-ksT-B•PC5020 BUBBLER 02 STRIP 1.15' 30 .(( 1 HUNTER 8 PGS -ARV -08, 45N. SHRUB ROTOR 2 4,2 4,2 ADJ ADJ 351 3.0 0.62 g GRISWOLD 0 2250 MASTER VALVE, PRESSURE REDUCING. RAINSIRD 0 PES REMOTE CONTROL VALVE. 0 RAINBIRD 0 33 DLRC QUICKCOUPUNG VALVE. NIBCO 0 7-113 GATE VALVE. LINE SIZE. L� RAINSIRD # i ESP -MC -24 CONTROLLER IN STAINLESS STEEL ENCLOSURE ASSEMBLY BY PTS l CONTROLLER AND STATION NUMBER N 8 VALVE SIZE I GPM FLOW PVC . SCHEDULE 40 SLEEVE PVC SCHEDULE 40 SPRINKLER LATERAL PVC SCHEDULE 40 IRRIGATION MAIN, 314' TO 1-1rY SIZE ` PVC CLASS 315 1 IRRIGATION MAIN, 2• AND 2-112' NOTE: CONTRACTOR SHALL INSTALL PRESSURE COMPENSATING NOZZLE SCREENS IN ALL SPRINKLER HEADS REQUIRING ADJUSTMENTS OF RADIUS. REFER TO MANUFACTURERS LITERATURE. RECORD DRAWING f THESE RECORD DRAWINGS(AS-BUILT DRAWINGS) HAVE BEEN PREPARED BASED ON INFORMATION SUBMITTED, IN PART BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, RJM DESIGN GROUP, INC. HAS NOT VERIFIED THIS INFORMATION AND IS NOT RESPONSIBLE FOR ITS ACCURACY OR ADEQUACY, NOR FOR ANY ERRORS OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO THESE DOCUMENTS AS A RESULT. Toby Mertens irrigation Consultant 333 Avenida Adobe San Clemente, Ca. 92672 E mail. MertensTQworldnet att.net Tel. (949) 498-44b!. Fax. (S49) 4984810 }41 &1 B • B ® • _ EM® CHECKED TM DATE SEP. 1999 U-1 }41 1{► DRAWN _ TM CHECKED TM DATE SEP. 1999 U-1 SCALE 111=20' a JAB N0. .g 177 _. t ...� .. . .