HomeMy WebLinkAbout2769-46ELECTRICAL SYMBOL LIST GENERAL NOTES LIGHTING FIXTURE SCHEDULE N TELEVISION SIGNAL OUTLET 1. ALL UNDERGROUND UTILITIES OR STRUCTURES REPORTED BY THE OWNER OR OTHERS AND TYPE MANUFACTURER CATALOG@ LAMP QTY. & TYPE WAT AT GE VOLTS REMARKS FLUORESCENT LIGHT FIXTURE SHADING INDICATES FIXTURE ON THOSE SHOWN ON THE RECORDS EXAMINED ARE INDICATED WITH THEIR APPROXIMATE E I mEMERGENCY CIRCUIT is INTERCOM LOCATION AND EXTENT. THE OWNER BY ACCEPTING THESE PLANS OR PROCEEDING WITH DAY-BRITE (3) F32T8-3500'K 93 120 RECESSED 2'x4' FLUORESCENT FIXTURE WITH 27 CELL, „ IMPROVEMENTS PURSUANT THERETO AGREES TO ASSUME LIABILITY AND TO HOLD THE #2UGS332-39SL-1/3-EB-120 SEMI -SPECULAR, LOW IRIDESCENCE LOUVER AND CEILING MOUNTED RECESSED OR SURFACE MOUNTED LIGHT FIXTURE. SHADING INDICATES 12 ANOLOG, 120 VOLT, CLOCK AND CLOCK OUTLET, EDWARDS #1882A -S. TOP METALUX OF CLOCK TO BE AT +7 -4 ABOVE FINISHED FLOOR UNLESS NOTED OTHERWISE. ENGINEER HARMLESS FOR ANY DAMAGES RESULTING FROM THE EXISTENCE OF UNDERGROUND A #2P5GX-332S-39-M1-120V-EB81 3 -LAMP ELECTRONIC BALLAST O O ENGINEER; NOT INDICATED ON THE O FIXTURE ON EMERGENCY CIRCUIT UTILITIES OR STRUCTURES NOT REPORTED TO THE ENG EE , MANUAL MOTOR STARTER SWITCH. RATED ® 1HP. MIN-12OV-10-U.O.N. PUBLIC RECORDS EXAMINED;' LOCATED AT VARIANCE WITH THAT REPORTED OR SHOWN ON OR APPROVED EQUAL BY ® EXIT LIGHT FIXTURE PROVIDE COMPLETE WITH THERMAL OVERLOAD PROTECTION. RECORDS EXAMINED. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES H.E. WILLIAMS OR LIGHTOLIER TO PROTECT THE UTILITIES OR STRUCTURES FOUND AT THE SITE. IT SHALL BE THE DAY-BRITE (3) F32T8-3500'K 93 120 RECESSED 2'x4' FLUORESCENT FIXTURE WITH .125" STANDARD GRADE 20A, 120V, 10 GROUNDING TYPE DUPLEX RECEPTACLE FUSED DISCONNECT SWITCH. COMPLETE WITH REQUIRED NUMBER OF CONTRACTORS RESPONSIBILITY TO NOTIFY THE OWNERS OF THE UTILITIES OR STRUCTURES #2DF332-RA21-1 /3 -EB -120 THICK PRISMATIC LENS, REGRESSED ALUMINUM DOOR MOUNTED AT +15" AFF.- U.O.N. (SHADING INDICATES EMERGENCY CIRCUIT) "DUAL ELEMENT TIME DELAY" FUSES. AMPS -VOLTS, POLES AND CONCERNED BEFORE STARTING WORK. METALUX AND 3 -LAMP ELECTRONIC BALLAST FUSE SIZE AS INDICATED ON PLANS AND EQUIPMENT NAMEPLATE O #2FCXR-332A-A125-12OV-ES81 STANDARD GRADE 20A, 120V, 10 GROUNDING TYPE FOUR-PLEX RECEPTACLE DATA. 2. THE CONTRACTOR SHALL SECURE AND PAY FOR PERMITS AND FEES NECESSARY FOR OR APPROVED EQUAL BY MOUNTED AT +15" AFF.- U.O.N. (SHADING INDICATES EMERGENCY CIRCUIT) EXECUTION AND COMPLETION OF ELECTRICAL WORK, INCLUDING ALL CHARGES BY THE LOCAL H.E. WILLIAMS OR LIGHTOLIER ZJ COMBINATION MAGNETIC MOTOR STARTER/FUSED DISCONNECT SWITCH. GOVERNMENT AGENCIES AND THE UTILITY COMPANIES.RECESSED 2'x4' FLUORESCENT FIXTURE WITH .125" STANDARD GRADE 20A, 120V, 10 "GROUND FAULT INTERUPTER" (GFI) RECEPTACLE NEMA SIZE - VOLTS, POLES AS INDICATED. PROVIDE COMPLETE WITH DAY-BRITE 62 120 (2) F32T8-3500'K MOUNTED AT +15" AFF.- U.O.N. (SHADING INDICATES EMERGENCY CIRCUIT) HOA SELECTOR SWITCH, ON-OFF PUSH BUTTONS, PILOT LIGHTS, CONTROL 3, ALL OUTLET LOCATIONS SHALL BE COORDINATED WITH ARCHITECTURAL ELEVATIONS PRIOR #2DG232-RA21-1 /2 -EB -120 THICK PRISMATIC LENS, REGRESSED ALUMINUM DOOR METALUX AND 2 -LAMP ELECTRONIC BALLAST POWER TRANSFORMER AND THERMAL OVERLOAD PROTECTION PER TO INSTALLATION. ALL OUTLET COVER PLATES SHALL BE STAINLESS STEEL. © �. STANDARD GRADE 20A, 120V, 10 GROUNDING TYPE DUPLEX RECEPTACLE (SHADING INDICATES MOTOR NAMEPLATE DATA AND COIL VOLTAGE PER EQUIPMENT OR APPROVED 1 UAL B V -232 C C EMERGENCY CIRCUIT) C CEILING MOUNTED. CONTROL REQUIREMENTS. 4. THIS CONTRACTOR SHALL SUPPLY POWER TO AND MAKE CONNECTION TO ALL MOTORS AND H.E.APPROVED EQUAL TO EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS AS SHOWN ON THE MECHANICAL AND H.WILLIAMS OR LIGHTOLIER ® JUNCTION BOX. SIZED BY THIS CONTRACTOR PER ACTUAL NUMBER OF CONDUITS AND / OR CTB COMMUNICATION TERMINAL BACKBOARD. PLUMBING DRAWINGS, INCLUDING ALL FRACTIONAL HORSEPOWER MOTORS. IT SHALL BE THE DAY-BRITE(2) F32T8-3500'K 62 120 RECESSED 1'x4' FLUORESCENT FIXTURE WITH .125" CONDUCTORS PASSING THRU. RESPONSIBILITY OF THE CONTRACTOR TO REVIEW THE MECHANICAL AND PLUMBING DRAWINGS #1 DF232-FA21-1/2-EB-1 20 THICK PRISMATIC LENS, FLAT ALUMINUM DOOR AND FACP FIRE ALARM CONTROL PANEL. FOR DUCTS, LINES AND EQUIPMENT. METALUX 2 -LAMP ELECTRONIC BALLAST $ STANDARD 20A, 120/277V, 10 SPST TOGGLE SWITCH MOUNTED AT +48" AFF.-U.O.N. #FCXR-232-A125-12OV-ES81 d,b DENOTES TWO SWITCHES AND THIER RESPECTIVE CONTROL IDENTIFICATION FAA FIRE ALARM ANNUNCIATOR. 5. SEE SINGLE LINE DIAGRAM FOR CONDUIT AND CONDUCTOR SIZES, PANELS, TRANSFORMERS, OR APPROVED EQUAL BY 3 -DENOTE 3 -WAY SWITCHMOTOR CONTROL CENTERS, MECHANICAL EQUIPMENT, ETC. HOMERUNS TO PANELS MAY NOT BE H.E. WILLIAMS OR LIGHTOLIER FA FIRE ALARM CONDUIT 3/4", UNLESS OTHERWISE NOTED, WITH REQUIRED WIRING SHOWN ON PLANS BUT ARE PART OF THIS CONTRACT. 4 -DENOTE 4 -WAY SWITCH CONTAINED THEREIN (REFER TO FIRE ALARM SECTION OF THE SPECIFICATIONS). DAY-BRITE (2) F32T8-3500'K 62 120 MOUNT, 2 -LAMP FLUORESCENT RECESSED. FLANGE o 6. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY TYPE OF CEILING SYSTEMS #IDF232-1/2-EB-120 MOUNT, FLAT PRISMATIC ACRYLIC LENS, HINGE LATCH DIMMER METALUX AND DOOR, T8 LAMP ELECTRONIC BALLAST. TV TV SYSTEM CONDUIT 3/4" MIN., UNLESS OTHERWISE NOTED. AND TO FURNISH APPROVED LIGHTING FIXTURES OF THE TYPE REQUIRED FOR MOUNTING IN ❑ BRANCH CIRCUIT PANELBOARD. FLUSH OR SURFACE. MOUNTED AS INDICATED. SUBJECT CEILINGS. WHERE FIXTURES ARE RECESSED IN PLASTER CEILINGS, THEY SHALL " #MC -232-A125-120 EB81 TELEPHONE SYSTEM CONDUIT 3/4MIN., UNLESS OTHERWISE NOTED.PROVED EQUAL BY I T BE COMPLETE WITH NECESSARY MOUNTING HARDWARE AND PLASTER FRAMES. H.E.HH..E. WILLIAMS OR LIGHTOLIER ® PLYWOOD BACKBOARD. TELEPHONE/DATA SYSTEM CONDUIT 1 1 /4" MIN., UNLESS OTHERWISE NOTED. DAY-BRITE 62 120 1'X4', 2 -LAMP FLUORESCENT SURFACE. MOUNT, FLAT T/D 7. EXACT LOCATION OF ALL CEILING MOUNTED LIGHTING FIXTURES AND DEVICES .SHALL BE AS (2) F32T8-3500'K INDICATED ON ARCHITECTURAL REFLECTED CEILING PLANS. #1SM-232-FS01-1 /2 -EB -120 PRISMATIC ACRYLIC LENS, HINGE LATCH AND DOOR, ,CONDUIT CONCEALED WITHIN BUILDING WALLS OR CEILING SPACE. S SOUND SYSTEM CONDUIT 3/4" MIN., UNLESS OTHERWISE NOTED. E1 METALUX #FC-232A-120V-EB81 T8 LAMP ELECTRONIC BALLAST. - - CONDUIT ROUTED BELOW FlNISHED GRADE AND / OR CONCRETE SLAB. SCP SECURITY CONTROL PANEL. 8. UNLESS OTHERWISE NOTED, MOUNTING HEIGHTS INDICATED ON ELECTRICAL OUTLETS ARE OR APPROVED EQUAL BY FROM FINISHED FLOOR TO CENTER OF OUTLETS. H.E. WILLIAMS OR LIGHTOLIER -j}}- CONDUIT RUN WITH TICK MARKS INDICATE QUANTITY OF #12 THHN / THWN CONDUCTORS -U.O.N.. SECURITY DOOR STRIKE, COORDINATE TYPE TO BE PROVIDED WITH DOOR #1O CONDUIT SHOWN WITH NO TICK MARKS INDICATES 2 X112 THHN / THWN CONDUCTORS -U.O.N.. 0 HARDWARE MANUFACTURER. 9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CUT-OUTS IN TILE OR COUNTER SPLASHES DAY-BRITE (2) F25T8-3500'K 50 120 6' LONG, 2 -LAMP PROFILE, FLUORESCENT WITH RAPID 'C INDICATES CONDUCTOR SIZE AWG OR INDICATES KCMIL USE NEC CHAPTER 9 TABLE 3B FOR CONDUIT WHERE RECEPTACLES,'OUTLETS, ETC., OCCUR. #TT125-1/2-EB-120 START UTILITY STRIP, WIRE GUARD. ELECTRONIC SIZING EXCEPT AS NOTED ON PLAN. CONDUIT SHALL BE [ MINIMUM -U.O.N.. INCLUDE CODE T 0-4 HOUR SPRING WOUND TIMER, TORK A504H. METALUX BALLAST. SIZED COPPER BOND CONDUCTOR (NOT SHOWN ON PLAN) IN ALL CONDUIT RUNS. #6TSS-225-120V-EB81 WG/SS # 10. ALL RECESSED LIGHTING FIXTURES, DEVICES, ETC., MOUNTED IN FIRE RATED CEILING SHALL BE ENCLOSED WITH AN APPROVED ENCLOSURE CARRYING THE SAME FIRE RATING AS OR H.E.PPROVED EQUAL BY # THE CEILING. H.WILLIAMS OR LIGHTOLIER -•�- HOMERUN TO DESTINATION AS INDICATED. REFER TO CONDUIT SYMBOL ABOVE. 0 FULLY SPEED VARIABLE CEILING FAN CONTROLLER, LUTRON NTFS-12E COLOR AS SELECTED BY ARCHITECT. TELEPHONE OUTLET MOUNTED AT +15" AFF.-U.O.N.. 11. ALL SURFACE MOUNTED LIGHTING FIXTURES SHALL BE APPROVED FOR DIRECT MOUNTING ON DAY-BRITE 64 120 SAME AS FIXTURE TYPE "F" EXCEPT 32W LAMP, CHAIN #TT125- LOW DENSITY COMBUSTIBLE CEILINGS. 1 2 -120 (2) F32T8-3500'K HUNG AND SHALL BE 4' LONG. / -EB DI METALUX DATA OUTLET MOUNTED AT +15" AFF.-U.O.N. F1 12. THE NUMERAL(S) SHOWN AT TOP LIGHT FIXTURE IDENTIFICATION SYMBOL WHICH OR APPROVED EQUAL BY HAIN/SET-U DI COMBINATION TELEPHONE/DATA OUTLET MOUNTED AT +15" AFF.-U.O.N.. INDICATES NUMBER OF LIGHT FIXTURES REQUIRED SHALL NOT BE USED BY THE CONTRACTOR H.E. WILLIAMS OR LIGHTOLIER FOR HIS QUANTITY TAKE -OFF AT BIDDING OR FOR DETERMINATION OF HOW MANY FIXTURES so SMOKE DETECTOR, CEILING MOUNTED. WILL BE INSTALLED. THE CONTRACTOR SHALL INSTALL A LIGHT FIXTURE WHEREVER A LITHONIA64 120 (2) F32T8-3500'K 8' LONG, 2 -LAMP PROFILE FLUORESCENT, RAPID FIXTURE OUTLET IS SHOWN ON DRAWINGS.TDMW 232AR START, ENCLOSED AND GASKETED, HIGH IMPACT FIRE ALARM REPORTING STATION (F -i MOUNTED AT +4'-0" (REFER TO FIRE ACRYLIC LENS, RE-INFORCED POLYESTER FIBERGLASS GARDCO(1) 250W HPS 302 208 POLE MOUNTED HID FIXTURE WITH HEAT AND IMPACT #G18-1-4XL-250HPS-208-BRP RESISTANT TEMPERED FLAT GLASS LENS, TYPE IV OR DISTRIBUTION, AND 18' STRAIGHT SQUARE STEEL POLE f MCGRAW/EDISON (INVISION) No #VXM-250HPS-208-4-B2 ARCHITECT. 11. CUSTOM COLOR AS SELECTED BY HYDREL(1) 175W MH 210 208 IN -GRADE HID FIXTURE WITH DIFFUSE REFLECTORAND o, #9100 A- MH175-208-MFL-34 CLEAR FLAT LENS. �+ OR APPROVED EQUAL a� O 0 McPHILBENFB SPF(1) 100W A19 100 120 WALL MOUNTED INCANDESCENT FIXTURE WITH ILSAF o 22A02J6 PRISMATIC DIFFUSER. REFERENCES & ABBREVIATIONS T #100-120-2125 O # I co N � O LIGHTING FIXTURE DESIGNATION MCB MAIN CIRCUIT BREAKER / FLA FULL LOAD AMPS PROGRESS (1) 60W A19 60 120 WALL MOUNTED ADJUSTABLE INCANDESCENT LIGHT N e DETAIL REFERENCE P3231-30 FIXTURE. # C. CONDUIT OR EQUAL 00 / e MECHANICAL EQUIP. DESIGNATION O N VOLTS �2 KEYNOTE REFERENCE ,q• AMPS �J a GARDCO 142 120 7' HID LIGHTCOLUMN WITH 6" DIAMETER EXTRUDED Li / A.F.F. _ABOVE FINISH FLOOR GFI GROUND FAULT INTERRUPTER #LD600-C-84"-100MH-120SC (1) 100W M.H. COLUMN, ONE PIECE VIRGIN ACRYLIC LENS, SPECULAR U.O.N. UNLESS OTHERWISE NOTED GND GROUND O OR APPROVED EQUAL ALZAK REFLECTOR SYSTEM AND CLEAR GLOW RINGS. 0� CUSTOM COLOR AS SELECTED BY ARCHITECT. 00 C.O. CONDUIT ONLY W/PULL ROPE- � WP WEATHER PROOF V•L' VERIFY LOCATION - 3 A.C. ABOVE COUNTER N r. - T CU. COPPER PRUDENTIAL 64 120 6"SQ. X 6' LINEAR WALL MOUNTED FLUORESCENT WITH N.L. NIGHT LIGHT #P-60-040-M4-1-08-CTETW-35A (2) F32T8-3500'K ASYMMETRICAL LENS AND HIGH FREQUENCY O v M.L.O. MAIN LUGS ONLYEM. EMERGENCY OR EQUAL TO NEORAY ELECTRONIC BALLAST. CUSTOM COLOR AS SELECTED #83 BY ARCHITECT. SFD SMOKE FIRE DAMPER 3 J g Virginia Dare Tower 10470 Foothill Blvd. Rancho Cucamonga California 9173.0-3754 tel: 909 987 0909 fax: 909 980 9980 co C � O N C� O cidLL O Q v O c� �' � a$ U � LLM CONSULTANT • • 23412 Moulton Parkway, Suite Loguno Hills, CA 92653 (949) 830-1552 Fox (949) 830-8921 E -Mail: mailOombengrs.com APPROVED U L 3,0 2002 APPROVED AR�y���,j� V�' �F r4rr �� i v LARRY-WOLFF A, I., C-9784 .Q .y OFGP~~~.. Iia SYMBOLS, GENERALvi NOTES, FIXTURE! SCHEDULE IT - DRAWN DRAWN ALARM SECTION OF THE SPECIFICATIONS). CHECKED MWK/RLL 13. NO CONDUIT SHALL BE RUN HORIZONTALLY IN CONCRETE FLOOR SLABS. 9-16-99 SCALE AS NOTED JOB NO. 98177 HOUSING, WE LOCATION. FIRE ALARM HORN, MOUNTED AT +10'-0" (REFER TO FIRE ALARM 14. ALL WIRING AND ELECTRICAL EQUIPMENT INSTALLED FOR MECHANICAL AND PLUMBING EQUIPMENT SHALL BE IN ACCORDANCE WITH THESE DRAWINGS AND THE WIRING DIAGRAMS OF DAY-BRITE 33 120 SURFACE WALL MOUNTED 8"x2' FLUORESCENT FIXTURE SECTION OF THE SPECIFICATIONS). THE MECHANICAL AND PLUMBING DRAWINGS. #CD217W-1 /2 -EB -120 (2) F17T8-3500'K WITH INJECTION MOLDED CLEAR ACRYLIC LENS AND DUCT SMOKE DETECTOR. PROVIDED BY THE ELECTRICAL CONTRACTOR,METALUX El 15. ALL FINAL CONNECTIONS TO OWNER -FURNISHED EQUIPMENT SHALL BE MADE BY THE G #BI-217-IS-12OV-EB81 ELECTRONIC BALLAST FIXTURE SHALL BE MOUNTED UP WHERE THE WALL & CEILING MEET. INSTALLED BY THE MECHANICAL CONTRACTOR FINAL TERMINATIONS BY CONTRACTORS. OR APPROVED EQUAL BY THE ELECTRICAL CONTRACTOR. H.E. WILLIAMS OR LIGHTOLIER Q TAMPER SWITCH (FURNISHED AND INSTALLED BY PLUMBING CONTRACTOR, 16. THE CONTRACTOR SHALL VISIT THE SITE INCLUDING SPECIFICALLY ALL AREAS INDICATED HE SHALL THOROUGHLY FAMILIARIZE HIMSELF WITH THESE EXISTING DAY-BRITE(2) F32T8-3500'K 62 120 SURFACE MOUNTED 4' STAGGERED STRIP CONNECTED BY THIS CONTRACTOR). ON THE DRAWINGS. CONDITIONS AND BY SUBMITTING A BID ACCEPTS CONDITIONS UNDER WHICH HE WILL BE #SS232-1 /2 -EB -120 FLUORESCENT FIXTURE WITH ELECTRONIC BALLAST. O METALUX Fs FLOW SWITCH. FURNISHED AND INSTALLED BY PLUMBING CONTRACTOR, REQUIRED TO PERFORM HIS WORK. #SSL -232 CONNECTED BY THIS CONTRACTOR). 17. IT SHALL BE THIS CONTRACTOR'S RESPONSIBILITY TO DO ALL CORING, CUTTING, APPROVED EQUALBY H.E.APPROVED EQUAL TO H.WILLIAMS OR LIGHTOLIER PIV POST INDICATOR VALVE, (FURNISHED AND INSTALLED BY PLUMBING CONTRACTOR,CONNECTED BY THIS CONTRACTOR). PATCHING AND REFINISHING OF WALLS AND SURFACES WHEREVER IT IS NECESSARY FOR HIM TO PENETRATE FOR HIS WORK. ALL OPENINGS MADE SHALL BE SEALED TO MEET THE RATED KIRLIN F32T4-3500 K ( 1) ' 34 120 RECESSED COMPACT FLUORESCENT DOWNLIGHT WITH SELF LOW IRIDESCENCE INTEGRITY OF THE PARTICULAR WALL, FLOOR OR CEILING. #RR80602-45-LE EQUAL TRIPLE TUBE 6" APERTURE, -FLANGED ' OR APPROVED SPECULAR ALZAK ALUMINUM REFLECTOR AND SPECIAL RECEPTACLE MOUNTED AT +15" A.F.F. - U.O.N.. AMPS - VOLTS & ® 18. ATTENTION IS CALLED TO THE FACT THAT THE CEILING SYSTEMS FOR THE MOST PART ARE EDS ION PRICE OR LIGHTOLIER ELECTRONIC BALLAST. PHASE AS INDICATED ON PLANS. VERIFY NEMA CONFIGURATION WITH INSTALLED EQUIPMENT SUPPLIER PRIOR TO PLACING ORDER. CONSIDERED TO BE INACCESSIBLE. THE CONTRACTOR SHALL STRATEGICALLY LOCATE BOXES, ETC., IN AN ACCESSIBLE CEILING SPACE. SQ SPEAKER WITH BAFFLE AND BACKBOX RECESSED. CEILING MOUNTED. 19, ALL FIRE ALARM DEVICES SHALL BE U.L. LISTED AND APPROVED BY THE CALIFORNIA KIRLIN T4-3500'K WIPLE 34 120 RECESSED COMPACT FLUORESCENT DOWNLIGHT WITH U.O.N. STATE FIRE MARSHAL. tRR80622-40-45-46-LE TUBE 6" APERTURE, WHITE GROOVELESS FLARE TRIM, OUTDOOR WEATHER PROOF SPEAKER, MOUNTED AT +10'-0" O OR APPROVED EQUAL REGRESSOR PRISMATIC TEMPERED SPREAD LENS AND HEAT DETECTOR, CEILING MOUNTED. 20 THE CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING COMPATIBILITY OF ALL EDSION PRICE OR LIGHTOLIER ELECTRONIC BALLAST. COMMUNICATIONS/SIGNALING SYSTEM DEVICES TO PROVIDE COMPLETE AND OPERABLE KIRLIN 34 120 RECESSED COMPACT FLUORESCENT DOWNLIGHT WITH VSA VISUAL STROBE ANNUNCIATOR, MOUNT AT 80" ABOVE FINISH FLOOR OR 6" BELOW SYSTEMS. CEILING, WHICHEVER IS LOWER. 21. ALL CONDUITS TO BE CONCEALED. RUN CONDUITS IN MASONRY WALLS VERTICALLY. #RR80618-LE F32T4-3500 K" TUBE WIPLE 6" APERTURE, RADIAL POLYCARBONATE LENS, WHITE VISUAL STROBE ANNUNCIATOR AND MINI -SOUNDER, MOUNT STROBE AT 80 .ABOVE K OR APPROVED EQUAL EDSION PRICE OR LIGHTOLIER MOLDED POLYCARBONATE TRIM RING, ELECTRONIC BALLAST AND U.L. LISTED FOR WET LOCATIONS. VSA FINISH FLOOR OR 6 BELOW CEILING, WHICHEVER IS LOWER, AND SOUNDER AT +8'-0". 22. INSTALL RACEWAY .SYSTEMS AS FOLLOWS: MOLDED CASE CIRCUIT BREAKER (SINGLE LINE DIAGRAM). CANLETF26T4 28 120 CEILING TYPE WALL MOUNTED ON WALL NON-METALLIC A. RIGID GALVANIZED STEEL IN ALL OUTDOOR LOCATIONS AND IN INDOOR LOCATIONS CURRENT TRANSFORMER (SINGLE LINE DIAGRAM). WHERE SUBJECT TO PHYSICAL DAMAGE. �GFC26HIGGHR (1) -3500'K TRI PLE TUBE COMPACT FLUORESCENT VAPOR PROOF FIXTURE WITH O OR APPROVED EQUAL - RED HEAT-TREATED GLASS GLOBE AND ELECTRONIC UTILITY METER AND SOCKET (SINGLE LINE DIAGRAM). O B. I.M.C. OR E.M.T. IN ALL INDOOR AREAS. - BALLAST. AS AMPERE SWITCH (SINGLE LINE DIAGRAM). C. FLEXIBLE METAL CONDUIT FOR FINAL CONNECTIONS TO LIGHT FIXTURES, MOTORS, VIBRATING ELECTRICAL EQUIPMENT AND HORIZONTAL RUNS IN WOOD STUD WALLS. AT AMPERE TRIP (SINGLE LINE DIAGRAM). ALKCO #HP -213 (2) T5/8W 20 120 42" NARROW FLUORESCENT UNDERCABINET LIGHT, 5"W D CONDUIT FORUNDERGROUND RUNS. USE 20 MIL PVC TAPED RIGID STEEL RISER OR EQUAL 2700K x 1-1/8"H, HIGH PERFORMANCE BALLAST. i�-- ND. GROUND. ELBOWS RISERS CONDUI STUB M O - (ALKCO) CEILINGOCCMANUPANCY SENSOR AND SWITCHPACK. REFER TO SPECIFICATIONS ��� E.... USE COMPRESSION TYPE FITTINGS FOR ALL METALLIC CONDUIT. ACCEPTABLE F. 1" CONDUIT MINIMUM FOR UNDERGROUND INSTALLATIONS. KICHLER(2) 60W A19 120 120 SURFACE CEILING MOUNTED INCANDESCENT DRUM <0.j WALL -SWITCH TYPE OCCUPANCY SENSOR, REFER TO SPECIFICATIONS FOR K-8010 WH APPROVED EQUAL FIXTURE WITH OPAL GLASS DIFFUSER. ACCEPTABLE MANUFACTURER.9R 23. CONDUIT ROUTING INDICATED ON THESE PLANS IS DIAGRAMMATIC. ACTUAL ROUTING OF O LIGHTOLIER OR HALO v❑ -I VOLUME CONTROL- MOUNTED'+44" ABOVE FINISHED FLOOR UNLESS CONDUITS SHALL BE COORDINATED IN THE FIELD TO AVOID INTERFERENCE WITH OTHER NOTED OTHERWISE. UTILITIES AND TRADES. THE CONTRACTOR SHALL INSTALL ALL CONDUIT, JUNCTION/PULL KIRLIN (1) 70W HPS 93 120 RECESSED HID DOWNLIGHT WITH 6" APPETURE, BOXES, ETC., AS REQUIRED FOR A COMPLETE SYSTEM IN FULL COMPLIANCE WITH ALL EH SURFACE MOUNTED WEATHERPROOF PUSH BUTTON, CONNECTED TO SOUND APPLICABLE CODES. #0RR 50619-24-45-46--94-FR-LP SEAMLESS TAPERED BLACK OPTI GROOVE WITH WHITE SYSTEM RACK. 24. ALL EXTERIOR MOUNTED EQUIPMENT SHALL BE WEATHERPROOF OR PROVIDED IN A O O EDISON PRICE OAPPROVED R LIAGHTOLIER FLANGE, REGRESSED FRENSEL LENS AND U.L. LISTED FOR WET LOCATIONS. WEATHERPROOF ENCLOSURE. EH SECURITY KEYPAD MOUNTED +44" AFF, LION. 25. ALL POWER AND LIGHTING BRANCH CIRCUITS SHALL BE INSTALLED WITH A #12 GREEN GROUND WIRE U.O.N.. THE COMPLETE ELECTRICAL SYSTEM SHALL BE GROUNDED IN ACCORDANCE WITH KIRLIN (1) 1OOW HPS 116 120 RECESSED HID DOWNLIGHT WITH 8" APPETURE, #RR50820-24-45-46-FR-LP SEAMLESS TAPERED BLACK OPTI GROOVE WITH WHITE O OR APPROVED EQUAL FLANGE, REGRESSED FRENSEL LENS AND U.L. LISTED 26. THE CONTRACTOR SHALL SUBMIT COMPLETE FIRE ALARM SYSTEM SHOP DRAWINGS TO FOR EDISON PRICE OR LIGHTOLIER FOR WET LOCATIONS. CUSTOM COLOR BLACK TRIM REVIEW AND RECEIVE APPROVAL FROM THE AUTHORITY HAVING JURISDICTION PRIOR TO INSTALLING ASSEMBLY. THE SYSTEM. KIM (1) 150W HALOGEN 150 120 WALL MOUNTED SCONCE FIXTURE WITH SMOOTH GLASS 27. THE FOLLOWING TESTS SHALL BE WITNESS BY THE INSPECTOR: #WF30C LENS, INTERNAL SANDBLAST. A. NEUTRAL FAULT SYSTEM TEST. NEC ARTICLE 250-23(a). ® OR EQUAL TO ALUMILITE T4 MINICAN BASE B. TORQUE SETTING OF THE TERMINAL LUGS. NEC ARTICLE 110 GARDCO (1) 250W HPS 302 208 POLE MOUNTED HID FIXTURE WITH HEAT AND IMPACT AG18-1-3XL-250HPS-208-BRP-HS RESISTANT TEMPERED FLAT GLASS LENS, HOUSE SIDE R OR SHIELD, TYPE III DISTRIBUTION, AND 18' STRAIGHT MCGRAW/EDISON (INVISION) SQUARE STEEL POLE #SSS18-4-11. CUSTOM COLOR #VXM-250HPS-208-3-B2-HS AS SELECTED BY ARCHITECT. GARDCO (1) 250W HPS 302 208 POLE MOUNTED HID FIXTURE WITH HEAT AND IMPACT #G1 8-1 -Q-250HPS-208-BRP RESISTANT TEMPERED FLAT GLASS LENS, TYPE V R1 OR DISTRIBUTION, AND 18' STRAIGHT SQUARE STEEL POLE MCGRAW/EDISON (INVISION) #SSS18-4-11. CUSTOM COLOR AS SELECTED BY #VXM-250HPS-208-3-B2 ARCHITECT. GARDCO(1) 250W HPS 302 208 POLE MOUNTED HID FIXTURE WITH HEAT AND IMPACT #G18-1-4XL-250HPS-208-BRP RESISTANT TEMPERED FLAT GLASS LENS, TYPE IV OR DISTRIBUTION, AND 18' STRAIGHT SQUARE STEEL POLE f MCGRAW/EDISON (INVISION) No #VXM-250HPS-208-4-B2 ARCHITECT. 11. CUSTOM COLOR AS SELECTED BY HYDREL(1) 175W MH 210 208 IN -GRADE HID FIXTURE WITH DIFFUSE REFLECTORAND o, #9100 A- MH175-208-MFL-34 CLEAR FLAT LENS. �+ OR APPROVED EQUAL a� O 0 McPHILBENFB SPF(1) 100W A19 100 120 WALL MOUNTED INCANDESCENT FIXTURE WITH ILSAF o 22A02J6 PRISMATIC DIFFUSER. REFERENCES & ABBREVIATIONS T #100-120-2125 O # I co N � O LIGHTING FIXTURE DESIGNATION MCB MAIN CIRCUIT BREAKER / FLA FULL LOAD AMPS PROGRESS (1) 60W A19 60 120 WALL MOUNTED ADJUSTABLE INCANDESCENT LIGHT N e DETAIL REFERENCE P3231-30 FIXTURE. # C. CONDUIT OR EQUAL 00 / e MECHANICAL EQUIP. DESIGNATION O N VOLTS �2 KEYNOTE REFERENCE ,q• AMPS �J a GARDCO 142 120 7' HID LIGHTCOLUMN WITH 6" DIAMETER EXTRUDED Li / A.F.F. _ABOVE FINISH FLOOR GFI GROUND FAULT INTERRUPTER #LD600-C-84"-100MH-120SC (1) 100W M.H. COLUMN, ONE PIECE VIRGIN ACRYLIC LENS, SPECULAR U.O.N. UNLESS OTHERWISE NOTED GND GROUND O OR APPROVED EQUAL ALZAK REFLECTOR SYSTEM AND CLEAR GLOW RINGS. 0� CUSTOM COLOR AS SELECTED BY ARCHITECT. 00 C.O. CONDUIT ONLY W/PULL ROPE- � WP WEATHER PROOF V•L' VERIFY LOCATION - 3 A.C. ABOVE COUNTER N r. - T CU. COPPER PRUDENTIAL 64 120 6"SQ. X 6' LINEAR WALL MOUNTED FLUORESCENT WITH N.L. NIGHT LIGHT #P-60-040-M4-1-08-CTETW-35A (2) F32T8-3500'K ASYMMETRICAL LENS AND HIGH FREQUENCY O v M.L.O. MAIN LUGS ONLYEM. EMERGENCY OR EQUAL TO NEORAY ELECTRONIC BALLAST. CUSTOM COLOR AS SELECTED #83 BY ARCHITECT. SFD SMOKE FIRE DAMPER 3 J g Virginia Dare Tower 10470 Foothill Blvd. Rancho Cucamonga California 9173.0-3754 tel: 909 987 0909 fax: 909 980 9980 co C � O N C� O cidLL O Q v O c� �' � a$ U � LLM CONSULTANT • • 23412 Moulton Parkway, Suite Loguno Hills, CA 92653 (949) 830-1552 Fox (949) 830-8921 E -Mail: mailOombengrs.com APPROVED U L 3,0 2002 APPROVED AR�y���,j� V�' �F r4rr �� i v LARRY-WOLFF A, I., C-9784 .Q .y OFGP~~~.. Iia SYMBOLS, GENERALvi NOTES, FIXTURE! SCHEDULE IT - DRAWN DRAWN TEAM -1 CHECKED MWK/RLL DATE 9-16-99 SCALE AS NOTED JOB NO. 98177