Loading...
HomeMy WebLinkAbout2769-45NOTE: WATER HEATER FLUE SHALL TERMINATION AS PER UPC SECTION 517.0 MINIMUM 8 FEET FROM THE WALL OR ABOVE THE WALL. WLC UNDISTURBED ARTH E A B avd(hoaQS1 META T U CONRETE THRUST L BES OS FLUE C De D BLOCK TYP D 0 A 4O Vir inia Dare Tower ` BxB10470 Foothill Blvd. D D o STORM COLLAR 'll o o I I Ranch o Cucomonga BxB California 91730-3754 ' PLUGGED TEE ROOF ROOF FLASHING JACK THRUST BLOCK AT 90.ELBOW THRUST BLOCK AT TEE SEE SPECIFICATIONS t o 9 0 9 9 8 7 0 9 0 9 L COORDINATEWITH ROOFER fax: 909 980 9980 E FIN GRADE BtB IND FLANGE 3/8-STEEL R ODS i BxB VC PIPE VENT THRU ROOF . D AC PIPE 4 o xB BLOCK DIM'S BxB 1/2 BxB 1.5L ADAPTER 45 OR 22-112• FITTING CONDITION AT STUB GATE VALVE FOR ROOF CONSTR. SE ARCH. RWGS NOTES: E C D 1. THRUST BLOCKS SHALL BE INSTALLED AT EVERY CHANGE OF DIRECTION. METAL RESTOS TYPE 'B' WITH WALL LL SEE PLANS FOR FLUE SIZE 2. THRUST BLOCKS ARE FOR '150 LB. CLASS A/C PIPE, CAST IRON OR PVC PIPE BASE ON 1,000 LB/SF SOIL BEARING LOAD. SCALE SCALE Q� THRUST BL-W--K DETAIL NONE 8 FLUE THRU ROOF DETAIL NONE 3 > . Q 0 :3 L) . .- 04-J 120V-10 �� • — 3/4" QIESEL FUEL SUPPLY LINE TO AUTOMATIC FIRE SPRINKLER TIMECLOCK@E U � AND 1 DIESEL FUEL RETURN LINE AS SYSTEM 0 C� N NUT W LOCK WASHER PIPE STRAP TYP. QE CIRCUIT BREAKER FLOW SWITCH l �S do THR ADED ROD, N TYPICAL uNISTRUT CHANNEL, TYPICAL WET PIPE ALARM VALVE REDWOOD BLOCKING _ ANCHOR CHANNEL TO OS&Y VALVE WITH— . CP O FINISH GRADE CONC., TYPICAL TAMPER SWITCH MAIN DRAIN VALVE l 1 �„�■■, um " o 2 MAIN DRAIN(FLOW © • '�� ' � .. , � • r, r. ,. ... • ;, ,., • , • LEST. UNE). •. ti �.� , .., . '.... �,,. . t , •• . , �;•• «. �.: ; •' r', , .�, , 2 MAIN DRAIN SPILL F. ' s •• : , TO OUTSIDE OF BLDG. SWITCH QE • �� r t .; � .'! , , .'.' • :'' .. '•' s.•.' % � ";: •. '. • ., ' .. •,,w .,+ • , �• 1 . ;. � ", i,. �..,, •., • �... FINISH FLOOR a v . , , t , . AQUASTAT IN ,41 ' c a, '4 a WELL PROVIDE SLEEVE THRU SLAB FLOOR QE ITEM -INDICATED ON THE ELECTRICAL DRAWING STREET WATER SUPPLY--....,�— PER NFPA-13 AND SPECIFIED IN THE ELECTRICAL SEC11ONS F OF THE SPECIFICATION. THRUST BLOCK, SEE DETAIL NO. 6 ©ITEM INDICATED ON THE PLUMBING DRAWING AND SPECIFIED IN THE PLUMBING SECTIONS OF THE SPECIFICATION. CONSULTANT w 0 NOTE: ALL DIESEL FUEL PIPING SHALL BE ANCHORED TO 4" X 4" REDWOOD BLOCKING WITH BP & Associates, Inc. UNISTRUT CHANNEL AND PIPE STRAPS. BLOCKING SHALL BE SET IN MASTIC Consulting Engineers AT 6'-0" ON CENTER. 14471 Chambers Rd. Suite 102 Tustin, Cdffomia 92180 Teleehane (714) 734 1777 SCALE SCALE161 SCALE ax 714 734 1783 - PIPE STRAPPING DETAIL N�NI- S FIRE SPRINKIER RISER DETAIL NOW CIRC. PUMP WIRING DIA,GFi�p1N0 NONE 2 .�M�,.,�� _ rir r nv v w �pfESS/ NOTE: WATER HEATER STRAP I G SHALL BE AT POINTS WITHIN THE UPPER ONE-THIRD (1/3_) AND% DISTAN EN OFTFOUR (jj 3 NCHESSS ALL BE MAINTAINED ABOVE THE CONTROLS TNTTH MMTNHN E SMTRAPPING. O GAS TIGHT TRAFFIC WT. 7 DAY TIMECLOCK ' o' chol & TIRING BY ELEC. MANHOLE WITH GALV. ® +54"A.F.F. STEEL FRAME AND COVER. C.O.T.G. PROVIDE 1 1/2" SECTION AND THREAD TEE FOR MOUNTING WELL FIN. GRADE APPROVED A ,, NOTES: AQUASTAT 'MH" N0. HOT WATER, COLD WATER & L4006A, SET TO Y „ .�IUL: O OU . MANHOLE &SAMPLE 1 ALL CONDENSATE DRAIN LINES HOT WATER RETURN LINES BOX EXTENSIONS " DRAIN LINE SHALL BE AT LEAST O ET STOP T120SF AND INSIDE BUILDING SHALL BE SEE PLANS FOR EXACT 2 VENT THE .SAME SIZE AS THE NIPPLE ( AS REO'D TO GRADE s ON THE DRAIN PAN. INSULATED IN ACCORDANCE WITH SIZE AND LOCATION) 1 —SHUT-OFF VALVE (TYPICAL) • THE REQUIREMENTS OF SECTION p 4" INLET s . ' ,. . �; .„ 15400, PLUMBING SPECIFICATIONS. 4 DIAMETER FLUE THRU ,. " OUTLET ROOF, SEE DETAIL CP BRASS CLEANOUT PLUG (THREADED) 3 SEE DETAIL NUMBER 2 02 SEE DRAWING FOR .SIZES. 1 — APPROVED R 4 U3 TRAP DEPTH SHALL BE EQUAL TO UNION (TYPICAL) ='t�� O A a SPILL FULL SIZE • s THE A/C UNIT TOTAL STATIC / SI �,, — PRESSURE PLUS 1-INCH BUT RE LIEF TO FLO R SINKSURE U BALANCING VALVE 1 NOT LESS THAN 2-INCHES. BLOCK SADDLE BETWEEN U CHECK VALVE (TYPICAL) = LARRY-WOLFF HEATER AND WALL (TYP) 1/16" THICK x :r WIDE C-9784 Q , STEEL STRAP AROUND S wk 01/31,t A NIT SECURE UNISTRUT TO (TYP) ',��'9%• ���_ -— WALL WITH 318 0x3 WATER HEATER lYP i SLEEVE ANCHOR 16" O.C. GAS COCK ''�+�,OF...���`'��� AT MASONRY WALL OR 14 .. t. . , .: •�.+. 6" LONG DIRT LEG X 3" MIN. LONG SMS 16 O.C. AT STUD WALL (TYP). � SECURE 2" x 2" x 1/4" X 0'-3" NO DATE BY REMARKS ANGLE IRON TO WATER HEATER tom' 2x6 REDWOOD GRADE BOARD TURNBUCKLE (TYP) LEG'S WITH (2) # 10 TEK BOLTS vi DRAIN PAN AND SECURE TO FLOOR WITH ` SEE NOTE 3 3 8"0 x 4" SLEEVE ANCHOR AT � FOR CONTINUATION / �. OF PIPING, SEE • EACH LEG. MIN. EMBEDMENT 2", 4 REQUIRED, 1 ® EA CORNER. ll4?Fz PLANS.. UNION 1"x4" WOOD � ... .ENTIRE INSTALLATION SHALL CONFORM BLOCK 5/16.0 HOLE (TYP.) TO THE MANUFACTURERS RECOMMENDATIONS HOTEL 1/4- THREAEDED ' AND SHALL MEET LOCAL JURISDICTION SEE SHEET P-2 FOR LOCATION OF 3/8"0 x 3" SLEEVE ANCHOR TURNBUCKLE SEISMIC STRAP SPECIFICATION AND STANDARDS. SAND & OIL INTERCEPTOR. 16" O.C. AT COCN. WALL MIN. 16 GA. TYP. OR #14 x 3" MIN. LONG SMS V� TYPE "M" COPPER TUBING WITH 16" O.C. AT STUD WALL " UNISTRUT AS=BUILTSDETAILS WROUGHT COPPER FITTINGS 0- UNISTRUT " W//U 0 THREADED ROD 0 P2378-3 1/4 STUD NUT WITH (�- MODEL P1000 SPRING. 1/2" MIN. 2 P40 . OIL scALE DETAIL SCALE 4 WATER HEATER DEAIL SCALE 1SAND t� INTERCEPTOR 7 CONDENSATE TRAP� NONE NONE NONE DRAWN TP 90' ELBOW .TEE PIPE SIZE A B 3 &SMALLER 18 16 4 23 17 34 29 4 7 56" 48 DRAWN TP CHECKED TP DATE FEB. 1999 SCALE AS NO JOB N0. I: 98177