HomeMy WebLinkAbout2769-42r
GAS METER U
'1 1/2" G DN
CW DN 0 WALL
L. GRADE
® +
GAS
CALCULATION
FLR.
(TYP
OF 4 PLCS)
EQUIPMENT
20" ABV.
TOTAL
DEVELOPED
LENGTH
CUBIC
d�
FROM
GAS METER TO
FEET PER
PIPE
MANUFACTURER
EQUIPMENT FOR LOW
PRESSURE GAS
HOUR
SIZES
WATER HEATER
A.O. SMITH BT -100
150 FT.
75 CFH
3 4" GAS UNE
/
A/C UNIT
CARRIER
SERIES 48SX
150 FT.
40
CFH, 60 CFH
3 4" G, 3/4" G &
&
80 CFH
1'� G LINES
CLOTHES DRYER
150 FT.
35 CFH
3/4" GAS UNE
GAS RANGE
150 FT.
90 CFH
1" GAS LINE
GAS BARBECUE
150 FT.
80 CFH
1" GAS LINE
CW DN 0 WALL
L. GRADE
® +
20" ABV.
FIN.
FLR.
(TYP
OF 4 PLCS)
® +
20" ABV.
FIN.
FLR.
SYS.
DN
. GRADE
ADE WALL
WALL
TED TO WALL
O.V.
NOTES:
0 ALL HORIZONTAL STORM DRAIN PIPING ABV. CLG.
SHALL SLOPE AT 1% UNLESS OTHERWISE NOTED.
0 ALL CONDENSATE DRAIN PIPING ABV. CLG.
SHALL SLOPE AT 1X UNLESS OTHERWISE NOTED.
O ALL GAS PIPING SIZES INSIDE THE BUILDING
ARE BASED ON UNIFORM PLUMBIING CODE 1994
TABLE 12-3 (LOW PRESSURE AT TOTAL
DEVELOPED LENGTH 150 FEE & 500 CFH.
q FOR CONTINUATION OF ALL UTILITIES
SEE SHEET P1.1.
OALL SLEEVES THRU MASONRY WALLS & FOOTINGS
SHALL BE MIN TWO PIPE SIZES LARGER THAN THE
PIPE GOING THRU IT. ALSO, THE CONTRACTOR SHALL
PROVIDE ALL SLEEVES.
ALL STORM DRAIN LINES, WASTE LINES & COLD WATER
LINES INTO FOOTINGS SHALL BE DOUBLF HALF LAP
WRAPPED WITH 1/8- THICK "ARMOFLEX' INSULATION.
ALSO, THE CONTRACTOR SHALL PROVIDE BLOCKED OUT
AREAS IN THE FOOTING FOR STORM DRAIN LINES, WASTE
LINES & COLD WATER LINE. ALL PIPING SHALL AVOID
THE LOWER 8" OF THE FOOTING.
AS=BU,lSLTrT"'��
��77
NORTH
SCALE
Virginia Dare Tower
10470 Foothill Blvd.
Rancho Cucamonga
CaIifornio 91730-3754
tel: 909 987 0909
fax: 909 980 9980
V.81.,
I�
CZ5
CONSULTANT
EIP & Associates, Inc.
Consulting Engineers
14471 Chambers Rd. Suite 102
Tustin, California 9280
Tel hone (714) 734 1777
ox (714) 7341783
APPROVED
W
lF OF Cho'
APPROVED
Zi►7"� V ii��
JUL 302002:
APPROVED
O A��,`'��,
LARRY—WOLFF s,
C-9784
�c s
hMtai/31/DO
OF
NO DATE BYREMARKS
FLOOR PLAN
DRAWN TP
CHECKED TP
DATE FEB. 1999
SCALE AS NOTED
JOB N0. I: 98177
P2.1