Loading...
HomeMy WebLinkAbout2769-40- FIXTURE SCHEDULE ROUGH -IN CONNECTIONS ROUGH -IN CONNECTIONS ITEM FIXTURE a.I— o DESCRIPTION ITEM FIXTURE EW- Cn IV)H ow DESCRIPTION 3 oQ oQ a w oQ oQ Q z3 c,3 0 i— 3 > =3 v3 0 /S NO. 2234.015 "MADERA", AQUAMETER SIPHON JET, FLOOR ZURN NO. ZN-1910-K-P, CAST IRON, ACID -RESISTING ENAMELED WATEROUNTED, ELONGATED BOWL. COMPLETE WITH SLOAN NO. 111-1.5- FS FLOOR 2» 2" 1_1/2» _ _ INSIDE COMPLETE WITH DOME STRAINER, NICKEL -BRONZE HALF GRATE 1 CLOSET INT. 4" 2" -- 1" -- YB-YC-YK FLUSH VALVE, WITH SUPPORT, OLSONITE 95CC-SS SEAT 1 SINK SEEPAGEFLANGE, TRAP PRIMER CONNECTION AND P -TRAP. AND A/S BOLT CAPS. /S NO. 2305.100 "MADERA ADA", AQUAMETER SIPHON JET, FLOOR HOSE __ __ -- " -- AND LOOSE KEY. WITH VACUUM BREAKER N/C WATER „ __ « __ OUN1E0, ELONGATED BOWL. COMPLETE WITH SLOAN ROYAL 111-1.5- HB BIBB 3/4 ACORN N0. 8126, FREE STANDING, CLOSET INT. 4 2 1 (HANDICAP) -YC-YK FLUSH VALVE WITH SUPPORT AND NO. B -73-A HANDLE, 2 LSONITE NO. 95CC-SS SEAT AND A/S BOLT CAPS. RHB RECESSED 3/4» ACORN NO. 8104, RECESSED WALL MOUNTED STAINLESS STEEL BOX UR A/S NO. 6541.132 "ALLBROOK", WALL HUNG, SIPHON JET, COMPLETE HOSE BIBB -- WITH VACUUM BREAKER AND LOCKING DOOR. URINAL INT. 2" 1-1/2" -- 3/4" - WITH, SLOAN ROYAL NO. 186-1-YB-YC FLUSH VALVE AND 1 1 ZURN NO. ZR -1222 WALL HANGER STAINLESS STEEL STRAINER. P.P.P. TRAP PRIMER VALVE, BRASS BODY, ADJUSTABLE, COMPLETE 1.1 K , WALL HUNG, SIPHONL (i) TRAP __ __ __ -_ 1/2» __ WITH 1/2" COPPER TYPE "L" PIPE TO RECPTOR. INSTALL PER UR URINAL TH SLOAN ROYAL NO. 186-1-YB-YC AND PROVIDE NO. B -73-A PRIMER MANUFACTURER'S RECOMMENDATIONS AND COMPLETE BEHIND 2 (HANDICAP) INT' 2" 1-1/2" -" 3/4" -- ANDLE FLUSH VALVE AND SUPPORT, ZURN NO. ZR -1222 WALL ACCESS PANEL. ANGER, STAINLESS STEEL STRAINER AND MOUNTED AT HANDICAP WATER ZURN Z-1700 SERIES "HYDROTROL" WATER HAMMER ARRESTOR EIGHT. WHA HAMMER __ __ __ __ __ __ COMPLETE BEHIND ACCESS PANEL. INSTALL PER MANUFACTURER'S S NO. 0496.011 OVALYN 11 , 20 X 17 , UNDER COUNTER 1 ARRESTOR RECOMMENDATION. L LAVATORY 11-1d4 2" 1-1/2" 1/2" 1/2" __ OMPETE WITH KOHLER NO. K-14518-1 FAUCET, HICAGO NO.327A GRID DRAIN, CHICAGO NO. 1006 LOOSE 1 EY STOPS WITH RIGID SUPPLIES AND L.A. PATTERN P -TRAP.• RD ROOF ZURN NO. ZC-100-ERC, CAST IRON DOME STRAINER, ADJUSTIBLE DRAIN SEE PLANS FOR SIZES EXTENSION SLEEVE, FLASHING COLLAR, GRAVEL STOP, CAST IRON DOME KOHLER NO. NO. K-3351, DOUBLE COMPARTMENT, 18 GAUGE 1 STRAINER, SUMP RECEIVER, UNDERDECK CLAMP AND IAPMO LISTED. TYPE 302 STAINLESS STEEL, UNDERCOUNTER MOUNTED 16" X 14" 7 1/2- DEEP. COMPLETE WITH KOHLER NO. K -7779-K FAUCET AND OD S ZURN NO. ZC-100-89-ERC, CAST IRON DOME STRAINER, COMPLETE SINK 1-1 /2 2" 1-1 /2" 1 /2" 1 /2" -- NO.16070-4 HANDLES COMPLETE WITH JUST NO. GRID GRID OVERFLOW SEE PLANS FOR SIZES W/ CLAMPING FLANGE, 2" HIGH WATER DAM AND IAPMO LISTED. 1 CHICAGO NO. 1006 LOOSE KEY STOPS WITH RIGID SUPPLIES AND 1 DRAIN AND L.A PATTERN P -TRAP, ADN VIKING NO. VCFW1020 DISPOSER, 1 HP 120 VOLTS, 1 PHASE, 60 CYCLE, 10 AMPS. yyg ACORN NO. 8186, TYPE 304 STAINLESS STEEL, RECESSED BOX UNIT » " WASHING 2" 2" 1 1 /2" 3/4" 3/4" -- WITH 3/4` HOT AND COLD WATER VALVES, SCREWDRIVER STOPS, ELKAY WCNSF-8100R 72 X 27 1/2- OVERALL LENGTH AND WIDTH 1 BOX VACUUM 'BREAKERS AND 2" WASTE CONNECTION. 8" BACKSLASH 14" DEEP SINGLE COMPARTMENT. COMPARTMENT SIZE 24" X 24" INSIDE DIMENSION, DRAIN BOARD SIZE 48" LENGTH AND JENSEN NO. 1000EE, 2 -COMPARTMENT PRE -CAST CONCRETE WIDTH OF 24" INSIDE DIMENSION. ELKAY LK -251 FULL SUPPORT LEGS AND -OIL' INTERCEPTOR, 1000 GALLON CAPACITY. COMPLETE 14 GAUGE TYPE 304 STAINLESS STEEL. WELDED 1/4" RADIUS COVED SI SAND -OIL WITH MANHOLES WITH CONCRETE MANHOLE EXTENSIONS TO S „ „ „ __ CORNERS. WELDS GROUND CLEAN ABLY SMOOTH. SINK MUST HAVE ADE AS REQUIRED AND 24 DIA'. GAS TIGHT IRON CAST TRAFFIC SINK 1-1/2' 2 1-1/2- 1/2- 1/2* NSF CERTIFICATION. FAUCET HOLES CENTERED ABOVE SINGLE 1 NTERCEPT ADE COVERS. ENTIRE INSTALLATION HALL CONFORM TO 2 COMPARTMENT ON 8" CENTERS. CHICAGO NO. 9238-613A PRE -RINSE WEIGHE MANUFACTURER'S RECOMMENDATIONS. NTH ADAPT FAUCET 4" TO 8 3/8" CENTERS 3/8" X 23" RISER R -SUPPLY ARMS 36i' S/S FLEXIBLE 80" SPRAY HEAD 1/2" FEMALE ET__ -- WILKINS N INLETS, ELKAY NO. LK -20 WASTE FITTING WITH STANDPIPE OVERFLOW, EXPANSION 0. WXT-18, SUSPENDED, 14 GALLON, DIAPHRAM HICAGO NO. 1006 LOOSE KEY STOPS WITH RIGID SUPPLIES AND 1 TANK TYPE, PRE -PRESSURIZED WITH WELDED EXTERIOR, BUM [FLOOR A. PATTERN P -TRAP. DIAPHRAM AND EPDXY COATED EXTERIOR. /S NO. 7740.020 "FLORWELL", ENAMELED CAST IRON CORNER DN DOWNSPOUT ZURN NO. ZANB-199, NICKEL BRONZE BODY, THREADED INLET AND SERVICE 3" 3„ 2" 3/4" 3/4" _ MOUNTED, COMPLETE WITH CHICAGO NO. 897 FITTING, NOZZLE _ -- -- -' - DECORATIVE FACE OF WALL FLANGE AND OUTLET NOZZLE. 1 SINK - A/S NO. 7721.038 3 DIAMETER DRAIN WITH STRAINER AND 1 (ZURN NO. Z-1040, NO -HUB ADAPTER). A/S NO. 7745.011 VINYL RIM GUARD AND HOSE. SH SYMMONS NO. 1-100VT-E VISU-TEMP . SHOWER ASSEMBLY. COMPLETE WITH VISU-TEMP PRESSURE BALANCING MIXING VALVE WITH 1 SHOWER -- -- -- 3/4 3/4„-- THERMOMETER, INTERNAL ADJUSTERS, TEMPERATURE LIMIT STOP, INTEGRAL STOPS, AND NO. 4-121 SUPER SHOWER HEAD. SYMM S NO. 117VT-FS-VB-X-K-830- M . COMPLETE WITH SHOWERVISU-TEMP PRESSURE BALANCING MIXING VALVE WITH INTEGRAL 2 (HANDICAP) -- -- -- 3/4 3/4 -- THERMOMETER, SUPER HEAD, HANDICAP HANDSPRAY WITH 60” HOSE AND SLIDE BAR, VACUUM BREAKER AND DIVERTER VALVE. Fp ZURN NO. ZN-415-8-P, CAST IRON, COMPLETE WITH ROUND FLOOR 1 DRAIN 2" 2" 1-1/2w -- -- -- NICKEL -BRONZE TOP, CLAMPING COLLAR, TRAP PRIMER CONNECTION AND P -TRAP. Fp ZURN NO. ZN-415-B, CAST IRON, COMPLETE WITH ROUND FLOOR 2 DRAIN 2" 2" -1/2'0 -- -- -- NICKEL -BRONZE TOP, CLAMPING COLLAR, AND P -TRAP. FD ZURN NO. ZN-662 CAST IRON, COMPLETE WITH ROUND POLISHED FLOOR 3 DRAIN 3" 3" -- -- -- -- NICKEL -BRONZE TOP, FLASHING COLLAR AND SEDIMENT BUCKET. WATER HEATER SCHEDULE SYMBOL ABBREVIATION DESCRIPTION GENERAL NOTES 0 INPUT RECOVERY INLET OUTLET OPER. MODEL NO. ITEM MANUFACTURER MODEL NO. SERVICE LOCATION STORAGE BTU/HR CAPACITY TEMP TEMPER INT. REMARKS OUTSIDE AIR INTAKES ON ROOF. SEE ARCHITECT DRAWINGS FOR DETAIL ON VENT THRU ROOF. ACCORDANCE WITH THE PROVISIONS OF THE PLUMBING CODE FOR TESTING DRAIN, WASTE AND VENT SYSTEM. Q EXACT LOCATIONS AND MOUNTING HEIGHTS OF PLUMBING FIXTURES SHALL BE OBTAINED FROM THE ARCHITECTURAL 16 THESE DRAWINGS INDICATE THE SEWER, WATER, AND STORM DRAIN SYSTEMS TO POINT OF CONNECTION 5'-0" CD DRAWINGS. ® 607 'F 'F LBS. PHASE 1 A.O. SMITH BT -100 DOMESTIC HOT WATER ROOM 117 100 GALLONS 75,000 114 GPH 60 120 1200 LBS MUST HAVE ASHRAE STICKER OR OTHERWISE COMPLY WITH TITLE 24 REQUIREMENTS FOR SERVICE WATER HEATERS. SOV RISER, PIPING, DETECTOR CHECK VALVE AND ANY OTHER EQUIPMENT REQUIRED.' IN ADDITION, SUBMITTAL SHALL BE ® CONNECTION BETWEEN INCOMPATIBLE MATERIALS ABOVE GRADE AND INSIDE BUILDINGS SHALL BE MADE WITH TWO (2) MADE FOR ALL MATERIAL AND EQUIPMENT. CPDELL 1 & GOSSETT SERIES 100 HOT WATER RETURN ROOM 117 CENTRIFUGAL 3 PUMP SCHEDULE SYMBOL ABBREVIATION DESCRIPTION GENERAL NOTES 0 CAPACITY MOTOR CWV� ITEM MANUFACTURER MODEL NO. SERVICE LOCATION STORAGE ALL HANDICAP WATER CLOSETS SHALL HAVE FLUSH VALVE WITH HANDLE ON OPEN SIDE. "ARMOFLEX" INSULATION. REMARKS ALL VALVES, UNIONS, ETC., TO BE SAME SIZE AS UNE SIZE UNLESS OTHERWISE INDICATED ON DRAWINGS. (BALL CLEANOUTS SHALL BE INSTALLED AS PER SECTION 707.0 AND 719.0 OF THE PLUMBING CODE. O ALL PLUMBING FIXTURE VENTS TO TERMINATE A MIN. OF 12 INCHES FROM ANY VERTICAL SURFACE AND 10 FEET FROM 15ALL ROOF DRAINS, OVERFLOW DRAINS AND RAINWATER PIPING WITHIN THE INTERIOR OF THE BUILDING SHALL BE TESTED IN . OUTSIDE AIR INTAKES ON ROOF. SEE ARCHITECT DRAWINGS FOR DETAIL ON VENT THRU ROOF. ACCORDANCE WITH THE PROVISIONS OF THE PLUMBING CODE FOR TESTING DRAIN, WASTE AND VENT SYSTEM. Q EXACT LOCATIONS AND MOUNTING HEIGHTS OF PLUMBING FIXTURES SHALL BE OBTAINED FROM THE ARCHITECTURAL 16 THESE DRAWINGS INDICATE THE SEWER, WATER, AND STORM DRAIN SYSTEMS TO POINT OF CONNECTION 5'-0" CD DRAWINGS. GPM HEAD HORSE VOLT PHASE CYCLE R.P.M. F ALL EXTERIOR GAS COCKS, WATER SHUT OFF VALVES AND/OR SEWER 17 BUILDING SHALL' BE PROVIDED WITH A AUTOMATIC SPRINKLER SYSTEM PER U.B.C. CHAPTER 9 SECTION 904 & NFPA 13. AS CLEANOUTS INSTALLED IN YARD BOXES SHALL ALL LOCAL CODES, AND INSURANCE UNDERWRITERS REQUIREMENTS. THE FIRE SPRINKLER CONTRACTOR SHALL HAVE THE COVERS CONSPICUOUSLY MARKED "GAS", "WATER", AND "SEWER" RESPECTIVELY. SUBMIT AN APPROVED AND STAMPED SET OF DRAWINGS SHOWING ALL SIZES AND LOCATIONS OF FIRE SPRINKLER POWER SOV RISER, PIPING, DETECTOR CHECK VALVE AND ANY OTHER EQUIPMENT REQUIRED.' IN ADDITION, SUBMITTAL SHALL BE ® CONNECTION BETWEEN INCOMPATIBLE MATERIALS ABOVE GRADE AND INSIDE BUILDINGS SHALL BE MADE WITH TWO (2) MADE FOR ALL MATERIAL AND EQUIPMENT. CPDELL 1 & GOSSETT SERIES 100 HOT WATER RETURN ROOM 117 CENTRIFUGAL 3 8 1 /12 115 1 fi0 1750 PROVIDED WITH BUILT—IN OVERLOAD LEGEND SYMBOL ABBREVIATION DESCRIPTION GENERAL NOTES 0 BEFORE COMMENCEMENT OF WORK, THE CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS, ELEVATIONS, DEPTH, SIZE, 0 ALL EQUIPMENT SHALL BE LATERALLY SUPPORTED IN ALL DIRECTIONS TO RESIST A MIN. OF 20% OF THE CWV� AND CHARACTERISTICS OF ALL UTILITIES AND PIPING, AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. EQUIPMENT'S OPERATING WEIGHT. SD SD t3 ALL SOIL OR WASTE PIPING THAT IS IMBEDDED IN CONCRETE SHALL BE DOUBLE HALF LAP WRAPPED WITH 1/8- THICK 2U ALL HANDICAP WATER CLOSETS SHALL HAVE FLUSH VALVE WITH HANDLE ON OPEN SIDE. "ARMOFLEX" INSULATION. 1 ALL VALVES, UNIONS, ETC., TO BE SAME SIZE AS UNE SIZE UNLESS OTHERWISE INDICATED ON DRAWINGS. (BALL CLEANOUTS SHALL BE INSTALLED AS PER SECTION 707.0 AND 719.0 OF THE PLUMBING CODE. O ALL PLUMBING FIXTURE VENTS TO TERMINATE A MIN. OF 12 INCHES FROM ANY VERTICAL SURFACE AND 10 FEET FROM 15ALL ROOF DRAINS, OVERFLOW DRAINS AND RAINWATER PIPING WITHIN THE INTERIOR OF THE BUILDING SHALL BE TESTED IN . OUTSIDE AIR INTAKES ON ROOF. SEE ARCHITECT DRAWINGS FOR DETAIL ON VENT THRU ROOF. ACCORDANCE WITH THE PROVISIONS OF THE PLUMBING CODE FOR TESTING DRAIN, WASTE AND VENT SYSTEM. Q EXACT LOCATIONS AND MOUNTING HEIGHTS OF PLUMBING FIXTURES SHALL BE OBTAINED FROM THE ARCHITECTURAL 16 THESE DRAWINGS INDICATE THE SEWER, WATER, AND STORM DRAIN SYSTEMS TO POINT OF CONNECTION 5'-0" CD DRAWINGS. OUTSIDE OF THE BUILDING. CONTINUATION OF THESE SYSTEMS IS SHOWN ON THE CIVIL DRAWINGS AND IS © ALL PIPING DISCHARGING INTO FLOOR -SINKS AND/OR FLOOR -DRAINS TO HAVE A MINIMUM AIR -GAP AS REQUIRED BY SPECIFIED UNDER ANOTHER SECTION OF THE SPECIFICTAIONS. THE PIPING SHALL BE INSTALLED TO MEET THE INVERT ELEVATIONS SHOWN ON THE CIVIL DRAWINGS. G LOCAL CODES. GAS LINE F ALL EXTERIOR GAS COCKS, WATER SHUT OFF VALVES AND/OR SEWER 17 BUILDING SHALL' BE PROVIDED WITH A AUTOMATIC SPRINKLER SYSTEM PER U.B.C. CHAPTER 9 SECTION 904 & NFPA 13. AS CLEANOUTS INSTALLED IN YARD BOXES SHALL ALL LOCAL CODES, AND INSURANCE UNDERWRITERS REQUIREMENTS. THE FIRE SPRINKLER CONTRACTOR SHALL HAVE THE COVERS CONSPICUOUSLY MARKED "GAS", "WATER", AND "SEWER" RESPECTIVELY. SUBMIT AN APPROVED AND STAMPED SET OF DRAWINGS SHOWING ALL SIZES AND LOCATIONS OF FIRE SPRINKLER _ SOV RISER, PIPING, DETECTOR CHECK VALVE AND ANY OTHER EQUIPMENT REQUIRED.' IN ADDITION, SUBMITTAL SHALL BE ® CONNECTION BETWEEN INCOMPATIBLE MATERIALS ABOVE GRADE AND INSIDE BUILDINGS SHALL BE MADE WITH TWO (2) MADE FOR ALL MATERIAL AND EQUIPMENT. DI -ELECTRIC UNIONS SEPARATED BY A TWELVE INCH (12") SECTION OF RED BRASS PIPE. FLOOR CLEANOUT ALL CLEANOUTS SHALL BE INSTALLED WHERE READILY ACCESSIBLE. THE CONTRACTOR SHALL COORDINATE ALL CLEAN- WALL CLEANOUT OUT LOCATIONS WITH EQUIPMENT, CABINETS, ETC., AND THE ARCHITECT PRIOR TO ANY INSTALLATION. RISER UP 10 SEE ARCHITECTURAL DRAWINGS FOR HANDICAP FIXTURE LOCATIONS AND MOUNTING HEIGHTS. (INSULATE ALL EXPOSED RISER DOWN HOT WATER AND DRAIN PIPING BELOW HANDICAP LAVATORIES AND SINKS PER SPECIFICATIONS.) ABOVE 11 INSULATION (SEE SPECIFICATION FOR TYPE REQUIRED) AND COVERING ON PIPE AND TUBING SHALL HAVE A FLAME l.r%r%r- A IN r% A T1►.A ►IAT TA ------ -- ...w . w......�. ....�. �.. ..�� �� �..�-�- - � .._ ._.. -_--- -.. - - --- - - • -- •--_' ACCESS PANEL LEGEND SYMBOL ABBREVIATION DESCRIPTION S OR W SOIL OR WASTE ABOVE FLOOR S OR W SOIL OR WASTE BELOW FLOOR OR GRADE CWV� CWV COMBINATION WASTE AND VENT BELOW FLOOR OR GRADE SD SD STORM DRAIN ABOVE FLOOR OD OD OVERFLOW DRAIN ABOVE FLOOR 1 V SANITARY VENT - CW COLD WATER - - HW HOT WATER - - - HWR HOT WATER RETURN CD CD CONDENSATE DRAIN TP TP TRAP PRIMER G G GAS LINE F F FIRE LINE AS AS AUTOMATIC SPRINKLER LINE DIRECTION OF FLOW _ SOV SHUT-OFF VALVE RP-BFP REDUCED PRESSURE BACKFLOW PREVENTOR FCO FLOOR CLEANOUT WCO WALL CLEANOUT RISER UP RISER DOWN ABV ABOVE AP ACCESS PANEL BEL BELOW CLG CEILING CONT CONTINUATION COTG CLEANOUT TO GRADE DN DOWN EXIST EXISTING FLR FLOOR FFE FINISH FLOOR ELEVATION HDR HEADER I.E. INVERT ELEVATION POC POINT OF CONNECTION VTR VENT THRU ROOF AIR EQUIPMENT SCHEDULE. ITEM EQUIPMENT DESCRIPTION INGERSOLL—RAND MODEL NO. 2475N5, TWO STAGE RECIPROCATING, MAXIMUM OVERALL DIMENSIONS SHALL BE 70" HIGH X 28" WIDE. THE COMPLETE UNIT SHALL BE BOLTED TO THE FLOOR AND PROVIDED WITH SEISMIC BRACES. AIR COMPRESSOR, 5 HP, 208 VOLTS, 3 PHASE, 60 HZ, COMPRESSOR SHALL DELIVERY 16.8 CFM AT 175 PSI. TANK SHALL BE 80 GALLON CAPACITY, VERTICAL TYPE. THE UNIT SHALL HAVE CENTRIFUGAL AC AIR COMPRESSOR PRESSURE RELEASE FOR "LOAD FREE" STARTING AND AUTOMATIC SWITCH TO START AND STOP AT PRESET MINIMUM AND MAXIMUM PRESSURE LIMITS. THE UNIT SHALL BE COMPLETE WITH THE FOLLOWING ACCESSORIES 1 MOUNTED ON THE UNIT. COMPLETELY ENCLOSED, CAL OSHA'' APPROVED BELT GUARD, OIL BATH AIR CLEANER, SAFETY VALVE, CHECK VALVE, AIR OUTLET VALVE, PRESSURE GAUGE, DRAIN VALVE, PRESSURE SWITCH, 208 VOLT, THREE PHASE, 60 HZ, MAGNETIC MOTOR STARTER WITH THREE PHASE OVERLOAD PROTECTION. APPROXIMATE OPERATING WEIGHT = 600 LBS. HR HOSE GROVER 2800 SERIES MODEL 2850U AIR REEL, MODEL 2851U WATER REEL AND MODEL 8842 ELECTRICAL REEL 1 REEL WITH MODEL 2810K ENCLOSURE. PROVIDE MODEL 7203A MOUNTING RAIL, MODEL 2800K END PANELS, AND MODEL 8840 ELECTRICAL REEL ADAPTER PLATE. SEE DRAWINGS FOR SUPPLIES AND LOCATIONS. QD QUICK DISCONNECT AMFLO MODEL NO. C10 AND CP9, 1/2" FEMALE NPT, PLATED STEEL COUPLER AND PLUG, WORKING PRESSURE 300 P.S.I. WITH ESCUTCHEON. AS-BUILTS .I� VA, i It e r s Virginia Dare.Tower 10470 Foothill Blvd. Rancho Cucamonga California 91730-3754 tel: 909 987 0909 fax. 909 980 9980 CONSULTANT BP & Associates, Inc. Consulting Engineers 14471 Chambers Rd Suite 102 Tustin, California 92180 Tele?hone (714) 734 1777 Fox (714) 7341783 APPROVED Of ESS/�,. CALVE APPROVED M.WBULTS JUL.3 0 2002 APPROVED .•"•••,•,"�,' '�c,E,D ARC, I� LARRY—WOLFF's, C-9784 Q s O_ F OF NO DATE JBY IREMARKS LEGEND, SCHEDULES 8 GEN. NOTE S DRAWN TP CHECKED TP DATE FEB. 1999 [SCALE AS NOTED JOB N0. L• 98177 I P0.1 I