Loading...
HomeMy WebLinkAbout2769-36NOTES, MEASURES AND RESTRAINTS TITLE -24 MANDATORY MEASURES EFFICIENCY STANDARDS ® Any appliance for which there is a California standard established in the Appliance Efficiency Standards may be installed only if the manufacturer has certified to the Commission, as specified in those regulations, that the appliance complies with the applicable standard for that appliance. Included are room air conditioners, central air conditioning heat pumps (regardless of capacity, except that required for central air conditioning heat pumps with cooling capacity of 135,000 Btu/hr or more apply to heating performance but not cooling performance), other central air conditioners with a cooling capacity less than 135,000 Btu/hr, fan type central furnaces with input rate less than 400,000 Btu/hr. boilers wall furnaces, floor furnaces, room heaters, unit heaters, and duct furnaces shall have been certified to the California Energy Commission by its manufacturer to comply with the Appliance Efficiency Standards. ® The following space conditioning equipment may be installed only if the manufacturer has certified that the equipment meets or exceeds all applicable efficiency requirements listed in standard 112 of the Energy Efficiency Standards; all air conditioners, heat pumps and condensing units > 135,000 Btu/hr; all water chillers; all gas-fired boilers > 300,000 Btu/hr; all oil -fired boilers > 225,000 Btu/hr, and all warm air furnaces and combination warm air fumances/air-conditioning units >225,000 Btu/hr. Fan type central furnaces shall not have a pilot light. ® Piping except those conveying fluids at temperatures between 607 and 105'F or within HVAC equipment shall be insulated in accordance with standard 123. ® Air handling duct systems shall be constructed, installed sealed, and insulated as provided in Chapter 10 of the Uniform Mechanical Code. CONTROLS w Each space conditionings tem shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time ;witch sh II be capable of programming different schedules for weekdays and weekends; incorporate an automatic holiday shut-off" feature that turns off all loads for at least 24 hoprs, then resumes the normally scheduled operation; and has program backup capabilities that prevent the foss of the devices program and time setting for at least 10 hours If power is Interrupted. o Each space conditioning system shall be installed with an occupancy sensor to control the operating period of the system. ® Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating thermostat setpoint. ® Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback cooling thermostat setpoint. o Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 sparefeet shall be provided with isolation zones. Each zone shall: not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dam ers, that allow the supply of heating or coolingg to be setback or shut off independently of other isolated areas; and shall be controlled by a time control device as des .1 ed above. ® Each space conditioning zone shall be controlled by an individual thermostatic control that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 557 or lower. For cooling, the control shall be adjustable up to 857 or higher. Where used to control both heating and cooling, the control shall be capable of providing a dead band of at least 5T within which the supply of heating and cooling is shut off or reduced to a minimum. ® Thermostats shall have numeric setpoints in T. (FARENHEIT) ® Thermostats shall have adjustable setpoint stops accessible only to authorized personnel. o Heat Pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. Electric resistance supplementary heater operation is permitted during transient periods, such as start-ups and following room thermostat setpoint advance, when controls are provided which use preferentail rate control, intelligent recovery, staging, romping, or similar control mechanisms designed to proclude the unnecessary operation of supplementary heating during the recovery period. Supplementary heater operation is also permitted during defrost. VENTILATION ® Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified in these plans. ® Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems. ® All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. ®Air Balancing:All space conditioning and ventilation systems shall be balanced to the quantities specified in these plans, in accordance with the National Environmental Balancing Bureau (NEBB) Procedural standards (1983), or Associated Air Balance Council (AABC) National Standards (1966). ® Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the installing licensed C-20 mechanical contractor. TE OF COMPLIANCE Pon 1 d s MECH 111 R0' NAME Cit of Fontana Fire Station No. 78 03-22-99 ROJECT ADDRESS So3-22-99 MOF 7282 Ciitrus Avenue, Fontana, CA 92069 erM a..e RINCIPAL DESIGNER —MECHANICAL Nack En ineerin949-720-1205 ONE NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL ❑ HOTEL/MOTEL GUEST ROOM RASE OF CONSTRUCTION ® OCUMENTATION AUTHOR TELEPHONE Mahmood Pezeshki 949720_1205 OOF OF ENVELOPE COMPLIANCE ❑ PREVIOUS ENVELOPE PERMIT ® 0N AUTFIOR AC-1AA4 HEAT PUMP THERMOSTAT? So3-22-99 MOF NOTE 70 FIELD UILDING CONDITIONED FLOOR AREA 3904 FAN CONTROL ® NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL ❑ HOTEL/MOTEL GUEST ROOM RASE OF CONSTRUCTION ® NEW CONSTRUCTION ❑ ADDITION ® ALTERATION ❑ UNCONDITIONED (File Affodavlt) ® PRESCRIPTIVE D PERFORMANCE SETBACK CONTROL OOF OF ENVELOPE COMPLIANCE ❑ PREVIOUS ENVELOPE PERMIT ® SEENE AVELOPERCHITECTURAL COMPLIANCEDWGS. ATTACHED A is Certificate of Compliance lists the builing features and performance specifications needed to comply with Title 24, arts 1 and 6 California Code of Regulations. This certificate applies only to building mechanical requirements. e Principal Mechanical Designer hereby certifies that proposed building design represented in this set of constuction ecuments is consistent with the other compliance forms and worksheets, with the specifications, and with any other culations submitted with this permit application. 'the proposed building has been designed to meet the mechanical uirements contained in sections 110 through 115, 120 through 124, 140 through 142, 144 and 145. lease check one: ® I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am civil engineer, mechanical engineer, or architect. n I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section 5537.2 of the Business and Professions Code to sign this document as the person responible for its preparation; and that I am a licensed contractor preparing documents for work that I have contracted to perform. I affirm that 1 am eligible under the exemption to Division 3 of the Business and Professions Code by Section of the Code to sign this document as the person responsible for its preparation; and for the following reason: OCUMENTATM AUTHOR SIGNATURE DATE Mahmood Pezeshki 03-22-99 PRINCIPAL MECHANICAL DESIGNER — NAME SONATURE DATE LIC. NO. Mahmood Pezeshki 1 103-22-99 M-29925 MANDATORY MEAOURES ndicoto location on plans of note Block Mandatory Measures MO -1 --- � APPLICANT Y Y s, ease o en Manual pubished by ton he Cali forno b Energy Commesbn. MECH — 1 Required on plans for all submittals. Parts 2 do 3 may be incorporated In schedules on pians. MECH — 2 Required for all submittals; choose appropriote version dependingg on method of mechanical compUance. MECH — 3 Required for all submittals. but form does not have to be completed if location of mechanical equipment schedule is indicated on the form per Section 4.3.3. MECH 4 Required for all submittals unless required outdoor ventilation rates and air flows are shown on plans per Section 4.3.4. 1 Nonresidential Compliance Form January 1995 rIFICATE OF COMPLIANCE PWt 2 Of S MECH -1 NAME City of Fontana Fire Station No. 78 ATE 03-22-99 MECHANICAL SYSTEMS SYSTEM NAME AC-1AA4 HEAT PUMP THERMOSTAT? TAM CONTROL NOTE 70 FIELD ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? VAV MINIMUM POSITION CONTROL? X YES S: Prog. Switch 0: 0004 mcy Sensor M: Manual Timer TiME CONTROL S : inlet vales P. Variable Pitch V: WD SIMULTANEOUS HEAT/COOL? N: NO s+PPIY SETBACK CONTROL B 0: Other AC -1.2.3.4 Return ISOLATION ZONES 0 HEAT AND COW. SUPPLY PAX VENTILATION OUTDOOR DAMPER HEAT PUMP THERMOSTAT? NA HIGH EFFICIENCY? B: Air Balance 0 Outside air Cart A. Auto G: Gravity ELECTRIC HEAT? NA M. Out Air Measure FAN CONTROL 0 D: Demand Contra VAv MINMUM POS1i7M CONTROL? NA N: Natural SIMULTANEOUS HEAT/COOL? NA HEAT AND COOL SUPPLY RESET? NA VENTILATION B OUTDOOR DAMPER CONTROL? A ECONOMIZER TYPE N OUTDOOR AIR CFM See sdNduk HEATING EQUIP. TYPE I HIGH EFFIC? Package 0=/M;q MAKE AND MODEL NUMBER 48SIf024 & 4NlSxDle COOLING EQUIP. TYPE I HIGH EFFIC? Padwgs waltloq Y MAKE AND MODEL NUMBER 48=24 & 48$XM CODE TABLES: Eater code from table blow into columns above. _ HEAT PUMP THERMOSTAT? TAM CONTROL SETBACK CTS. ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? VAV MINIMUM POSITION CONTROL? X YES S: Prog. Switch 0: 0004 mcy Sensor M: Manual Timer H: Heating C: Coding B: Both ter number of Zones. : inlet vales P. Variable Pitch V: WD SIMULTANEOUS HEAT/COOL? N: NO s+PPIY ATTIC 4.2 0: Other AC -1.2.3.4 Return ATTiC 4.2 HEAT AND COW. SUPPLY PAX VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM HIGH EFFICIENCY? B: Air Balance 0 Outside air Cart A. Auto G: Gravity A: Air W: Water Enter Outdoor Air CFM. M. Out Air Measure : Not Required Note: Tide Shap be an D: Demand Contra Mss than C*m G an N: Natural MECH - 4. DATE OF COMPLIANCE City of Fontana Fire Station No. 78ID Pwtsofa MECH-' ATE 03-22-99 Ti10N _ INSULLATION REQUIRED? Y I N ® ❑ ❑ ❑ ❑ ❑ ❑ o AS -B DUCT TAPE ALLOWED? 1 Y I N ❑ ® ❑ ® ❑ D ❑ ❑ ❑ ❑ SYSTEM NAME PIPE TYPE (may ftwm, eta) SYSTEM NAME DUCT TYPE (WY Return. eta) DUCT LOCATION (Rost. Pleresn. etc) DUCT INSULATION R — VALUE NOTE 70 FIELD AC -1.2.3.4 s+PPIY ATTIC 4.2 AC -1.2.3.4 Return ATTiC 4.2 PIPE INBULATM _ INSULLATION REQUIRED? Y I N ® ❑ ❑ ❑ ❑ ❑ ❑ o AS -B SYSTEM NAME PIPE TYPE (may ftwm, eta) NOTE TO FIELD DOMESTIC HOT WATER SUPPLY NOTE8 TTI FIELD - For aftw WMEwt t!M onrseidential Compliance Forth January 1995 i A r c h i t e c s Virginia Dare Tower 10470 Foothill Blvd. Rancho Cucamonga California 91730-3754 tel: 909 987 0909 fax: 909 980 9980 CONSULTANT 0 BP do Associates, Inc. Consulting Engineers 14471 Chambers Rd. Suite 102 92 Tustin, California 80 Telephone 714 7341777 Fox 7143 734 1783 APPROVED y y of CA0 APPROVED AS"BUILTS JUL 3 0 2002 APPROVED"%%I 'D AR�y' � v A LARRY—WOLFF ' C-9784 s ' Q kkol/31/00 OF ■ DRAWN — CHECKED AB DATE SEP. 1999 SCALE AS NOTED JOB NO. I: 98177