HomeMy WebLinkAbout2769-36NOTES, MEASURES AND RESTRAINTS
TITLE -24 MANDATORY MEASURES
EFFICIENCY STANDARDS
® Any appliance for which there is a California standard established in the Appliance Efficiency Standards may be installed only if
the manufacturer has certified to the Commission, as specified in those regulations, that the appliance complies with the
applicable standard for that appliance. Included are room air conditioners, central air conditioning heat pumps (regardless of
capacity, except that required for central air conditioning heat pumps with cooling capacity of 135,000 Btu/hr or more
apply to heating performance but not cooling performance), other central air conditioners with a cooling capacity less than
135,000 Btu/hr, fan type central furnaces with input rate less than 400,000 Btu/hr. boilers wall furnaces, floor furnaces,
room heaters, unit heaters, and duct furnaces shall have been certified to the California Energy Commission by its
manufacturer to comply with the Appliance Efficiency Standards.
® The following space conditioning equipment may be installed only if the manufacturer has certified that the equipment meets or
exceeds all applicable efficiency requirements listed in standard 112 of the Energy Efficiency Standards; all air conditioners, heat
pumps and condensing units > 135,000 Btu/hr; all water chillers; all gas-fired boilers > 300,000 Btu/hr; all oil -fired boilers
> 225,000 Btu/hr, and all warm air furnaces and combination warm air fumances/air-conditioning units >225,000 Btu/hr.
Fan type central furnaces shall not have a pilot light.
® Piping except those conveying fluids at temperatures between 607 and 105'F or within HVAC equipment shall be insulated
in accordance with standard 123.
® Air handling duct systems shall be constructed, installed sealed, and insulated as provided in Chapter 10 of the Uniform
Mechanical Code.
CONTROLS
w Each space conditionings tem shall be installed with an automatic time switch with an accessible manual override that allows
operation of the system during off -hours for up to 4 hours. The time ;witch sh II be capable of programming different
schedules for weekdays and weekends; incorporate an automatic holiday shut-off" feature that turns off all loads for at least
24 hoprs, then resumes the normally scheduled operation; and has program backup capabilities that prevent the foss of the
devices program and time setting for at least 10 hours If power is Interrupted.
o Each space conditioning system shall be installed with an occupancy sensor to control the operating period of the system.
® Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as
required to maintain a setback heating thermostat setpoint.
® Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as
required to maintain a setback cooling thermostat setpoint.
o Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 sparefeet shall
be provided with isolation zones. Each zone shall: not exceed 25,000 square feet; shall be provided with isolation devices, such
as valves or dam ers, that allow the supply of heating or coolingg to be setback or shut off independently of other isolated
areas; and shall be controlled by a time control device as des .1
ed above.
® Each space conditioning zone shall be controlled by an individual thermostatic control that responds to temperature within the
zone. Where used to control heating, the control shall be adjustable down to 557 or lower. For cooling, the control shall
be adjustable up to 857 or higher. Where used to control both heating and cooling, the control shall be capable of
providing a dead band of at least 5T within which the supply of heating and cooling is shut off or reduced to a minimum.
® Thermostats shall have numeric setpoints in T. (FARENHEIT)
® Thermostats shall have adjustable setpoint stops accessible only to authorized personnel.
o Heat Pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load
can be met by the heat pump alone. Electric resistance supplementary heater operation is permitted during transient periods,
such as start-ups and following room thermostat setpoint advance, when controls are provided which use preferentail rate
control, intelligent recovery, staging, romping, or similar control mechanisms designed to proclude the unnecessary operation of
supplementary heating during the recovery period. Supplementary heater operation is also permitted during defrost.
VENTILATION
® Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified in these
plans.
® Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air intakes and
discharges of all space conditioning and exhaust systems.
® All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to
the outside, except for combustion air openings.
®Air Balancing:All space conditioning and ventilation systems shall be balanced to the quantities specified in these plans, in
accordance with the National Environmental Balancing Bureau (NEBB) Procedural standards (1983), or Associated Air Balance
Council (AABC) National Standards (1966).
® Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be
measured and certified by the installing licensed C-20 mechanical contractor.
TE OF COMPLIANCE
Pon 1 d s MECH 111
R0' NAME
Cit of Fontana Fire Station No. 78
03-22-99
ROJECT ADDRESS
So3-22-99
MOF
7282 Ciitrus Avenue, Fontana, CA 92069
erM a..e
RINCIPAL DESIGNER —MECHANICAL
Nack En ineerin949-720-1205
ONE
NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL
❑ HOTEL/MOTEL GUEST ROOM
RASE OF CONSTRUCTION ®
OCUMENTATION AUTHOR
TELEPHONE
Mahmood Pezeshki
949720_1205
OOF OF ENVELOPE COMPLIANCE ❑ PREVIOUS ENVELOPE PERMIT ®
0N AUTFIOR
AC-1AA4
HEAT PUMP THERMOSTAT?
So3-22-99
MOF
NOTE 70
FIELD
UILDING CONDITIONED FLOOR AREA
3904
FAN CONTROL
®
NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL
❑ HOTEL/MOTEL GUEST ROOM
RASE OF CONSTRUCTION ®
NEW CONSTRUCTION ❑ ADDITION ® ALTERATION ❑ UNCONDITIONED (File Affodavlt)
®
PRESCRIPTIVE D PERFORMANCE
SETBACK CONTROL
OOF OF ENVELOPE COMPLIANCE ❑ PREVIOUS ENVELOPE PERMIT ®
SEENE AVELOPERCHITECTURAL COMPLIANCEDWGS. ATTACHED
A
is Certificate of Compliance lists the builing features and performance specifications needed to comply with Title 24,
arts 1 and 6 California Code of Regulations. This certificate applies only to building mechanical requirements.
e Principal Mechanical Designer hereby certifies that proposed building design represented in this set of constuction
ecuments is consistent with the other compliance forms and worksheets, with the specifications, and with any other
culations submitted with this permit application. 'the proposed building has been designed to meet the mechanical
uirements contained in sections 110 through 115, 120 through 124, 140 through 142, 144 and 145.
lease check one:
® I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this
document as the person responsible for its preparation; and that I am civil engineer, mechanical engineer, or architect.
n I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section 5537.2 of
the Business and Professions Code to sign this document as the person responible for its preparation; and that I am a
licensed contractor preparing documents for work that I have contracted to perform.
I affirm that 1 am eligible under the exemption to Division 3 of the Business and Professions Code by Section
of the Code to sign this document as the person responsible for its
preparation; and for the following reason:
OCUMENTATM AUTHOR SIGNATURE DATE
Mahmood Pezeshki 03-22-99
PRINCIPAL MECHANICAL DESIGNER — NAME SONATURE DATE LIC. NO.
Mahmood Pezeshki 1 103-22-99 M-29925
MANDATORY MEAOURES
ndicoto location on plans of note Block Mandatory Measures MO -1
--- � APPLICANT Y Y s, ease o en
Manual pubished by ton he Cali forno b Energy Commesbn.
MECH — 1 Required on plans for all submittals. Parts 2 do 3 may be incorporated In schedules on pians.
MECH — 2 Required for all submittals; choose appropriote version dependingg on method of mechanical compUance.
MECH — 3 Required for all submittals. but form does not have to be completed if location of mechanical equipment
schedule is indicated on the form per Section 4.3.3.
MECH 4 Required for all submittals unless required outdoor ventilation rates and air flows are shown on plans per
Section 4.3.4. 1
Nonresidential Compliance Form
January 1995
rIFICATE OF COMPLIANCE PWt 2 Of S MECH -1
NAME City of Fontana Fire Station No. 78 ATE 03-22-99
MECHANICAL SYSTEMS
SYSTEM NAME
AC-1AA4
HEAT PUMP THERMOSTAT?
TAM CONTROL
NOTE 70
FIELD
ISOLATION ZONES
FAN CONTROL
ELECTRIC HEAT?
VAV MINIMUM POSITION CONTROL? X YES
S: Prog. Switch
0: 0004 mcy Sensor
M: Manual Timer
TiME CONTROL
S
: inlet vales
P. Variable Pitch
V: WD
SIMULTANEOUS HEAT/COOL? N: NO
s+PPIY
SETBACK CONTROL
B
0: Other
AC -1.2.3.4
Return
ISOLATION ZONES
0
HEAT AND COW. SUPPLY PAX
VENTILATION
OUTDOOR DAMPER
HEAT PUMP THERMOSTAT?
NA
HIGH EFFICIENCY?
B: Air Balance
0 Outside air Cart
A. Auto
G: Gravity
ELECTRIC HEAT?
NA
M. Out Air Measure
FAN CONTROL
0
D: Demand Contra
VAv MINMUM POS1i7M CONTROL?
NA
N: Natural
SIMULTANEOUS HEAT/COOL?
NA
HEAT AND COOL SUPPLY RESET?
NA
VENTILATION
B
OUTDOOR DAMPER CONTROL?
A
ECONOMIZER TYPE
N
OUTDOOR AIR CFM
See sdNduk
HEATING EQUIP. TYPE I HIGH EFFIC?
Package 0=/M;q
MAKE AND MODEL NUMBER
48SIf024 & 4NlSxDle
COOLING EQUIP. TYPE I HIGH EFFIC?
Padwgs waltloq Y
MAKE AND MODEL NUMBER
48=24 & 48$XM
CODE TABLES: Eater code from table blow into columns above.
_
HEAT PUMP THERMOSTAT?
TAM CONTROL
SETBACK CTS.
ISOLATION ZONES
FAN CONTROL
ELECTRIC HEAT?
VAV MINIMUM POSITION CONTROL? X YES
S: Prog. Switch
0: 0004 mcy Sensor
M: Manual Timer
H: Heating
C: Coding
B: Both
ter number of
Zones.
: inlet vales
P. Variable Pitch
V: WD
SIMULTANEOUS HEAT/COOL? N: NO
s+PPIY
ATTIC
4.2
0: Other
AC -1.2.3.4
Return
ATTiC
4.2
HEAT AND COW. SUPPLY PAX
VENTILATION
OUTDOOR DAMPER
ECONOMIZER
O.A. CFM
HIGH EFFICIENCY?
B: Air Balance
0 Outside air Cart
A. Auto
G: Gravity
A: Air
W: Water
Enter Outdoor Air
CFM.
M. Out Air Measure
: Not Required
Note: Tide Shap be an
D: Demand Contra
Mss than C*m G an
N: Natural
MECH - 4.
DATE OF COMPLIANCE
City of Fontana Fire Station No. 78ID
Pwtsofa MECH-'
ATE 03-22-99
Ti10N
_
INSULLATION
REQUIRED?
Y I N
® ❑
❑ ❑
❑ ❑
❑ o AS -B
DUCT TAPE
ALLOWED?
1 Y I N
❑ ®
❑ ®
❑ D
❑ ❑
❑ ❑
SYSTEM NAME
PIPE TYPE
(may ftwm, eta)
SYSTEM NAME
DUCT TYPE
(WY Return. eta)
DUCT LOCATION
(Rost. Pleresn. etc)
DUCT INSULATION
R — VALUE
NOTE 70
FIELD
AC -1.2.3.4
s+PPIY
ATTIC
4.2
AC -1.2.3.4
Return
ATTiC
4.2
PIPE INBULATM
_
INSULLATION
REQUIRED?
Y I N
® ❑
❑ ❑
❑ ❑
❑ o AS -B
SYSTEM NAME
PIPE TYPE
(may ftwm, eta)
NOTE TO
FIELD
DOMESTIC HOT WATER
SUPPLY
NOTE8 TTI FIELD - For aftw WMEwt t!M
onrseidential Compliance Forth January 1995
i
A r c h i t e c s
Virginia Dare Tower
10470 Foothill Blvd.
Rancho Cucamonga
California 91730-3754
tel: 909 987 0909
fax: 909 980 9980
CONSULTANT
0
BP do Associates, Inc.
Consulting Engineers
14471 Chambers Rd. Suite 102
92
Tustin, California 80
Telephone 714 7341777
Fox 7143 734 1783
APPROVED
y y
of CA0
APPROVED
AS"BUILTS
JUL 3 0 2002
APPROVED"%%I
'D AR�y'
� v A
LARRY—WOLFF
' C-9784 s
' Q
kkol/31/00
OF
■
DRAWN —
CHECKED AB
DATE SEP. 1999
SCALE AS NOTED
JOB NO. I: 98177