HomeMy WebLinkAbout3135-2GENERAL NOTES 1. INSTALL PRESSURE AND NON -PRESSURE LINES AND ANY EQUIPMENT INSIDE PLANTING AREAS WHEREVER POSSIBLE. TEMS SHOWN OUT SIDE SUCH AREAS FOR PURPOSES OF CLARITY ONLY). 2. ALL EQUIPMENT SHALL BE SELECTED AND INSTALLED IN ACCORDANCE WITH SPECS AND CONSTRUCTION DETAILS SEE SHEET NO. LID. I. 3. FOR SYMBOL DESIGNATION, SEE LEGEND ON SHEET NO. LID. I. 4. WHERE PRESSURE REGULATING VALVES ARE USED, VALVES AREA TO BE ADJUSTED FOR OPTIMUM PRESSURE, OR AS NOTED ON DRAWING. 5 WAYS BY INDIVIDUATO LLLYY ADJOUSTING SPNKLRO HDS AND WALKS DVALOVES 6. AREAS THAT NEED TO BE DEFINED IN ORDER TO DETERMINE EXACT LOCATION OF SPRINKLER HEADS ARE THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO SEE THEY ARE DEFINED PRIOR TO INSTALLATION. 7. AS -BUILT DRAWINGS AND SPECS SHALL BE MAINTAINED ON SITE AT ALL TIMES. AS -BUILT DRAWINGS SHALL BE UPDATED ON A DAILY BASIS. NO SITE REVIEWS ARE TO BE CONDUCTED WITHOUT THESE DRAWINGS. 8. AREAS RECEIVING AN IRRIGATION SYSTEM SHALL BE REVIEWED AND VERIFIED BY THE INSTALLING CONTRACTOR FOR ACCURACY OF SIZE AND CONFIGURATION. IF DISCREPANCIES ARE FOUND THAT WOULD PROVE DETRIMENTAL TO FINAL COVERAGE, THIS SHALL BE BROUGHT TO THE OWNER'S ATTENTION BEFORE INSTALLATION. BY FAILING TO DO SO, THE CONTRACTOR MAY BE RESPONSIBLE FOR ANY ADJUSTMENTS REQUIRED. 9. PERFORM A HYDROSTATIC TEST OF THE MAINLINE AT 150 PSI FOR 3 HRS. MIN. DURATION, TEST SHOULD BE MONITORED AND APROVED BY LANDSCAPE ARCHITECT & CITY OF FONTANA. NOTE: VERIFY IF WIRES HAVE BEEN PULLED FOR THESE VALVES. IF NOT, PULLED WIRES WILL HAVE TO BE PROVIDED TO RUN NEW VALVES. NEW 32 STATION CONTROLLER. 4 PROVIDE ELECTRIC FROM EXISTING jCONTROLLER METER /7 x 2" f' ✓ /ff !/ THE BASIC CONTROLLER FOR THE CITY OF FONTANA MODEL - r' N0.(TSIN-SSTFONT), AND RADIO LINK ASSEMBLY MODEL N0.(TSIN-RLFONT), CONTAINS THE FOLLOWING: x QTY. MODEL DESCRIPTION; 1 TSIN-SSTFONT U.L. LISTED CONTROLLER AND CITY OF FONTA ENCLOSURE ASSEMBLY. 1 SB-24SS/120V V.I.T. STAINLESS STEEL METERED �T TRACT NO. 16112 ENCLOSURE. 1 132-86-08 NETWORK 8000 CONTROLLER. 1 RM32PC 32 PIN CONNECTOR. 1 GR588 GROUNDING ROD. 1 GRE58 GROUNDING ROD CLAMP. 1 993 INSTALLATION OF NETWORK 8000 1 X35 SENSOR INPUT BOARD. 2 997-8 SATELLITE OPTIMIZATION QTY. MODEL DESCRIPTION 1 TSIN-RLFONT RADIO LINK ASSEMBLY KIT. 1 995-63 SENSOR INPUT BOARD. 1 TE525-1_25 TIPPING RAIN BUCKET. 1 1 /4„ 11 5 /4" 2 3/4" >, 2 /4" 3/1� /4" �Jw 3/ „ MAINLINE .9 2' 2 BEHIND SIDEUJ�4LK 1 2 11 F 2 FF- 44. 96 L.; P 44.4 d' '57 _ L.� u� 5 g Z3 1 2R] 5 5 1 3 2 FF= 45,10 Z4 4 1 1/4" 1 1 „ 11 1 12 2' S 6 2 1" 6, 1 5 5 3/4 ETER 3/4" �r _________ FF 44.90 19 IP= _ 4A 4j r �l 3/4"-o 3/4 P- 44 10 r'14 1" 2 3/4" 2 ti f02 1 1 2' 1 2 1/2 1 1 1/2„ 2 1 1/ 1 1/ ' 2 2 2 1 1 12 29 2 Z 2 1 292' f ✓ �1 til... -` L. , , MAINLINE 2' BEH IND SIDEUJAL< 20 1 i __ .. F= 44 70 P= 44.2 GF=44.30 ^� gOF 44'.30 22 1R F~F= 44-80 P= 44:3 S 2 ,!= 2 3/4" 2 3/4" 2 19 1" N '�t 2 1 » 2j, 2 MAIN.INE 6 2 59H IND 31DOLUAL.IG o i IL 12 1R FF= 43.50P= 43.0 i JJ� 6 V1, SALES 1 '... `.. 3/411 21 � � . O Ea � I CE FF= 44.80 �_--�- NOTE. � P=� 44.3 :_.-- -__ __..__ _._..._ `7` _- L- � 25 2R r , MAINLINE SHOWN WITHIN PAVING FOR CLARITY ONLY, P=r 4 , ! ACTUAL MAINLINE LOCATION TO BE A MINIMUM OF Q� 3/4" 3/4 I I FF- 41./D 7 ti t M . t 18" OFF ADJACENT HARDSCAPE AND OTHER OBSTACLES TYI� Q' 1 �` "°���`� 1�4.a 2 1 3/41)FF = 45.46 P= 449 # i a 1 1 1 /4„ r 1 , 1 1 2 13 �__ _�_ I 1 3 13 _. 2 3/4 1 1/2 2 3/4 2 1 MA ANL INE Q 2' a 1 2 2 SEH IND SIDEUJ4LK 2 2Z7 8461 1 3 2 2 3/4„ 1 1 2 m 0 F, 2 4 1 �1 1 2 2 1 43 182 3/4 P= 41.50 11/2 2 43 P= .._41.0 4 2 11 „ 1 _ 1„ 2 MR 3 L D I RI GAT I ON PLAN z' 11 112114" 2' 0 10 20 40 Q, U� uU i FF= 43.20 P= 42. / 4- u r� • PREPA CONTRACTOR SHALL VERIFY THE FOLLOWING, PRIOR TO CONSTRUCTION: 0\ ' \ A WATER METER LOCATION. B� STATIC PRESSURE AVAILABLE. C) REMOTE CONTROL VALVE WIRES. IF THE LANDSCAPE CONTRACTOR NOTICES ANY DISCREPANCIES IN THE FIELD, IN RELATIONSHIP TO THESE SET OF PLANS, SHALL NOTIFY TO LANDSCAPE ARCHITECT BEFORE CONSTRUCTION. CONSTRUCTION NOTE: THESE SET OF PLANS SHALL BE COORDINATED BY THE LANDSCAPE CONTRACTOR WITH PREVIOUS DRAWINGS PREPARED BY THE LA GROUP DATED 03-15-89 SHEET L1.6 BEFORE ITS CONSTRUCTION. 07-28-2005 ",," SIGNED JeHN JR % DATE REGISTERED OFFFSSIONAL LANDSCAPE ARC,'�IlTEC,T - ATE OF CALIFORNIA - NO 1648 DRAWN Bl' SCALP: CITY OF FONTA r=m DES10t Mr. IltRIGATION PLAN n"TD �T TRACT NO. 16112 CHECKED Hr- DWG. NO. �A iP=47.6 7a V7 V7 FN(3Il��t RC.E A- 1 X35 C) NOTE: SEE SHEET L-2 FOR IRRIGATION DETAILS SEE SHEET L-3 FOR LEGEND, NOTES & SPEC'S 1 1/4" /4» 4" 1 3 " 3 4 _�-- JOHN HANNA + ASSOCIATES LANDSCAPE ARCHITECTURE 444 South Cedros Avenue, Studio 260 Solana Beach, California 92075 858/259-1967 - FAX 858/259-5656 SIGNATURE REVISIONS 1 41---02 REVISIONS PEF, C{_ T Y PLAN CHECK. MSA 05--10-02 %r2 6__24--02 REVISIONS PER CITY PLAN CHECK., 3 7-28-05 PREPARATION OF "AS -BUILT" PLAN BASED ON MARK-UPS PROVIDED BY INSTALLING CONTRACTOR. DATE 05-10-02 DRAWN BY SHEET TITLE "RECORD DRAWWG" LMD EMGATION PLAN JOB NO. 526 SHEET NO. L-1 / 3135 2 OF 7 SHEETS AUG �(