HomeMy WebLinkAbout3135-2GENERAL NOTES
1. INSTALL PRESSURE AND NON -PRESSURE LINES AND ANY EQUIPMENT
INSIDE PLANTING AREAS WHEREVER POSSIBLE. TEMS SHOWN OUT SIDE
SUCH AREAS FOR PURPOSES OF CLARITY ONLY).
2. ALL EQUIPMENT SHALL BE SELECTED AND INSTALLED IN ACCORDANCE
WITH SPECS AND CONSTRUCTION DETAILS SEE SHEET NO. LID. I.
3. FOR SYMBOL DESIGNATION, SEE LEGEND ON SHEET NO. LID. I.
4. WHERE PRESSURE REGULATING VALVES ARE USED, VALVES AREA TO BE
ADJUSTED FOR OPTIMUM PRESSURE, OR AS NOTED ON DRAWING.
5 WAYS BY INDIVIDUATO LLLYY ADJOUSTING SPNKLRO HDS AND WALKS
DVALOVES
6. AREAS THAT NEED TO BE DEFINED IN ORDER TO DETERMINE EXACT
LOCATION OF SPRINKLER HEADS ARE THE RESPONSIBILITY OF THE INSTALLING
CONTRACTOR TO SEE THEY ARE DEFINED PRIOR TO INSTALLATION.
7. AS -BUILT DRAWINGS AND SPECS SHALL BE MAINTAINED ON SITE AT ALL
TIMES. AS -BUILT DRAWINGS SHALL BE UPDATED ON A DAILY BASIS. NO SITE
REVIEWS ARE TO BE CONDUCTED WITHOUT THESE DRAWINGS.
8. AREAS RECEIVING AN IRRIGATION SYSTEM SHALL BE REVIEWED AND
VERIFIED BY THE INSTALLING CONTRACTOR FOR ACCURACY OF SIZE AND
CONFIGURATION. IF DISCREPANCIES ARE FOUND THAT WOULD PROVE
DETRIMENTAL TO FINAL COVERAGE, THIS SHALL BE BROUGHT TO THE
OWNER'S ATTENTION BEFORE INSTALLATION. BY FAILING TO DO SO, THE
CONTRACTOR MAY BE RESPONSIBLE FOR ANY ADJUSTMENTS REQUIRED.
9. PERFORM A HYDROSTATIC TEST OF THE MAINLINE AT 150 PSI FOR 3 HRS.
MIN. DURATION, TEST SHOULD BE MONITORED AND APROVED BY LANDSCAPE
ARCHITECT & CITY OF FONTANA.
NOTE:
VERIFY IF WIRES HAVE BEEN PULLED FOR THESE VALVES.
IF NOT, PULLED WIRES WILL HAVE TO BE PROVIDED
TO RUN NEW VALVES.
NEW 32 STATION
CONTROLLER. 4
PROVIDE ELECTRIC
FROM EXISTING
jCONTROLLER METER
/7
x
2"
f' ✓ /ff !/
THE BASIC CONTROLLER FOR THE CITY OF FONTANA MODEL - r'
N0.(TSIN-SSTFONT), AND RADIO LINK ASSEMBLY
MODEL N0.(TSIN-RLFONT), CONTAINS THE FOLLOWING:
x
QTY. MODEL DESCRIPTION;
1
TSIN-SSTFONT
U.L. LISTED CONTROLLER AND
CITY OF FONTA
ENCLOSURE ASSEMBLY.
1
SB-24SS/120V
V.I.T. STAINLESS STEEL METERED
�T
TRACT NO. 16112
ENCLOSURE.
1
132-86-08
NETWORK 8000 CONTROLLER.
1
RM32PC
32 PIN CONNECTOR.
1
GR588
GROUNDING ROD.
1
GRE58
GROUNDING ROD CLAMP.
1
993
INSTALLATION OF NETWORK 8000
1 X35
SENSOR INPUT BOARD.
2
997-8
SATELLITE OPTIMIZATION
QTY.
MODEL
DESCRIPTION
1
TSIN-RLFONT
RADIO LINK ASSEMBLY KIT.
1
995-63
SENSOR INPUT BOARD.
1
TE525-1_25
TIPPING RAIN BUCKET.
1 1 /4„
11
5
/4"
2 3/4"
>, 2
/4"
3/1�
/4"
�Jw 3/ „
MAINLINE .9 2'
2 BEHIND SIDEUJ�4LK
1 2 11 F 2
FF- 44. 96
L.; P 44.4
d'
'57 _
L.�
u�
5 g
Z3 1 2R]
5 5 1 3 2 FF= 45,10
Z4 4
1 1/4" 1 1 „ 11 1 12
2' S 6
2
1"
6, 1 5
5 3/4
ETER 3/4"
�r _________
FF 44.90
19
IP= _ 4A 4j
r
�l
3/4"-o
3/4
P- 44
10
r'14
1"
2
3/4"
2
ti
f02
1 1 2' 1
2
1/2 1
1 1/2„ 2 1 1/
1 1/ ' 2
2 2 1 1 12
29
2 Z
2 1 292'
f ✓ �1 til...
-` L.
,
,
MAINLINE 2'
BEH IND SIDEUJAL<
20 1 i
__ .. F= 44 70
P= 44.2
GF=44.30
^�
gOF 44'.30
22 1R
F~F= 44-80
P= 44:3 S
2
,!= 2
3/4"
2 3/4" 2 19
1" N
'�t
2 1 » 2j,
2
MAIN.INE 6 2
59H IND 31DOLUAL.IG o
i IL 12 1R
FF= 43.50P= 43.0
i JJ�
6
V1,
SALES
1
'... `.. 3/411 21 � � . O Ea � I CE
FF= 44.80 �_--�-
NOTE. � P=� 44.3 :_.-- -__ __..__ _._..._
`7` _- L- � 25 2R r ,
MAINLINE SHOWN WITHIN PAVING FOR CLARITY ONLY, P=r
4
, !
ACTUAL MAINLINE LOCATION TO BE A MINIMUM OF Q� 3/4" 3/4 I I FF- 41./D
7 ti t
M . t
18" OFF ADJACENT HARDSCAPE AND OTHER OBSTACLES TYI� Q' 1 �` "°���`�
1�4.a 2
1
3/41)FF = 45.46
P= 449 # i
a
1 1 1 /4„ r 1 , 1
1 2 13 �__ _�_ I 1
3 13 _.
2 3/4
1 1/2 2 3/4 2 1 MA ANL INE Q 2' a 1
2 2 SEH IND SIDEUJ4LK
2
2Z7
8461 1 3 2 2 3/4„ 1 1 2 m 0 F, 2 4 1 �1
1 2 2 1 43 182 3/4
P= 41.50
11/2
2 43 P= .._41.0 4
2 11 „ 1 _ 1„
2 MR
3
L D I RI GAT I ON PLAN z' 11 112114"
2'
0 10 20 40
Q, U� uU i
FF= 43.20
P= 42. /
4-
u
r� •
PREPA
CONTRACTOR SHALL VERIFY THE FOLLOWING,
PRIOR TO CONSTRUCTION: 0\
' \
A WATER METER LOCATION.
B� STATIC PRESSURE AVAILABLE.
C) REMOTE CONTROL VALVE WIRES.
IF THE LANDSCAPE CONTRACTOR NOTICES ANY
DISCREPANCIES IN THE FIELD, IN RELATIONSHIP
TO THESE SET OF PLANS, SHALL NOTIFY
TO LANDSCAPE ARCHITECT BEFORE CONSTRUCTION.
CONSTRUCTION NOTE:
THESE SET OF PLANS SHALL BE
COORDINATED BY THE LANDSCAPE
CONTRACTOR WITH PREVIOUS DRAWINGS
PREPARED BY THE LA GROUP
DATED 03-15-89 SHEET L1.6 BEFORE
ITS CONSTRUCTION.
07-28-2005
",,"
SIGNED
JeHN JR % DATE
REGISTERED OFFFSSIONAL
LANDSCAPE ARC,'�IlTEC,T - ATE OF CALIFORNIA - NO 1648
DRAWN Bl'
SCALP:
CITY OF FONTA
r=m
DES10t Mr.
IltRIGATION PLAN
n"TD
�T
TRACT NO. 16112
CHECKED Hr-
DWG. NO.
�A
iP=47.6
7a
V7
V7
FN(3Il��t RC.E A-
1 X35
C)
NOTE:
SEE SHEET L-2 FOR IRRIGATION DETAILS
SEE SHEET L-3 FOR LEGEND, NOTES & SPEC'S
1 1/4"
/4»
4"
1 3 "
3 4 _�--
JOHN HANNA +
ASSOCIATES
LANDSCAPE ARCHITECTURE
444 South Cedros Avenue, Studio 260
Solana Beach, California 92075
858/259-1967 - FAX 858/259-5656
SIGNATURE
REVISIONS
1 41---02 REVISIONS PEF,
C{_
T Y PLAN CHECK.
MSA 05--10-02
%r2 6__24--02 REVISIONS PER
CITY PLAN CHECK.,
3 7-28-05 PREPARATION OF
"AS -BUILT" PLAN BASED ON
MARK-UPS PROVIDED BY
INSTALLING CONTRACTOR.
DATE 05-10-02
DRAWN BY
SHEET TITLE
"RECORD DRAWWG"
LMD
EMGATION PLAN
JOB NO.
526
SHEET NO.
L-1 / 3135
2 OF 7 SHEETS
AUG �(