HomeMy WebLinkAbout3118-1GENERAL NOTES: 1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTI❑N ('GREEN BOOK'). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED. 2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE 'GREEN BOOK', THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION. 3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER, 4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISI❑N PRIOR TO THE START OF ANY WORK, INSPECTI❑N C❑ORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST N❑N-METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEAT❑RS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES. 7. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY, 8, THE WALLS AND FACES OF ALL EXCAVATI❑NS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT. 9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT -❑F -WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE. 10. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATI❑N, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATI❑N OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION. 11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRI❑R TO WORK AROUND THEIR FACILITIES. 12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITH❑UT THE APPROPRIATE AGENCY AUTHORIZATI❑N. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS. 13. STATIONING REFERS TO THE CENTERLINE OF SEWER EXCEPT WHERE OTHERWISE NOTED, 14. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES, THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATI❑N OF BENCHMARKS AND CONSTRUCTI❑N CONTROL STAKING DURING CONSTRUCTION. 15. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCHMARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER. 16. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCHMARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTI❑N SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION S❑ THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT, 17. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE C❑NSTRUCTI❑N AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 18. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES. 19. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT -❑F -WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL, 20. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECT❑R. 21. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTI❑N OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED. 22. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ER❑DEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS. 23. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE. 24. IF SEWER CONSTRUCTION IS TO BE DONE IN PHASES, THE CONTRACTOR SHALL PROVIDE A TERMINAL CLEANOUT AT THE PHASE BOUNDARY, NOT MORE THAN 150 FEET FROM THE DOWNSTREAM MANHOLE, SEE CITY OF FONTANA STANDARD DETAIL FOR TERMINAL CLEANOUT, 25. SANITARY SEWER LINES SHALL BE CONSTRUCTED OF BELL AND SPIGOT OR BAND SEAL TYPE VITRIFIED CLAY PIPE (V.C.P.) EXTRA STRENGTH CLASS AND SHALL CONFORM TO THE PROVISIONS OF THE ASTM DESIGNATI❑N C700 FOR Y.C.P. 26, NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRI❑R APPROVAL OF THE CITY ENGINEER. 27. SHORT V.C.P. STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED AT MANHOLE WALLS TO ALLOW FOR MINOR DEFLECTION IN ALIGNMENT. 28. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION AND L❑CATION OF CONNECTIONS, CITY APPROVAL OF C❑NNECTI❑NS TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATI❑NS OR LOCATIONS SHOWN ON THE PLANS. 29. ALL 4' HOUSE LATERALS SHALL BE INSTALLED AT A 2% MINIMUM GRADE UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER. 30. TERMINATE ALL 4' HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH A PLUG 12' BELOW THE GROUND SURFACE, WHEN PUBLIC UTILITY EASEMENTS EXIST NEXT TO THE STREET RIGHT-OF-WAY, THE LATERAL SHALL TERMINATE 3 FEET INSIDE THE LOT AS MEASURED FROM THE UTILITY EASEMENT, 31. THE SEWER CONTRACTOR SHALL STAMP AN 'S' IN THE FACE OF THE CURB AT THE LOCATI❑N OF THE SEWER LATERAL. 32. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY. 33. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. 34. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRI❑R TO PAVING OF STREETS. 35. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRI❑R TO PLACEMENT, 36. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETI❑N OF PAVING. 37. UPON COMPLETION OF CONSTRUCTI❑N, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER. 38. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PR❑VIDE RECORD DRAWING TO THE CITY ENGINEER. OWNER: BADI❑LA HOMES BB32 SIERRA AVENUE FONTANA, CA 92335 (909) 428-9988 �ilillillI� I III llllq� 1111 l m lid w "o w A N 0 RIYAAW R [*-A Ll IN THE UTILITY PURVEYORS. SEWER: CITY OF FONTANA 8353 SIERRA AVENUE FONTANA, CA 92335 909-350-7610 WATER: FONTANA WATER COMPANY 8440 NUEVO AVENUE FONTANA, CA 92335 909-822-2201 POWER: SOUTHERN CALIFORNIA EDISON COMPANY 7951 REDWOOD AVENUE FONTANA, CA 92336 909-357-6221 SOUTHERN CALIFORNIA GAS COMPANY 16231 VALLEY BLVD. FONTANA, CA 92335 909-428-8411 TELEPHONE: VERIZON CALIFORNIA, INC. 13911 PARK AVENUE VICTORVILLE, CA 92392-2407 760-245-0846 CABLE: ADELPHIA COMMUNICATIONS 1257 W. BROOKS STREET ONTARIO, CA 91763 909-481-1115 CONTRACTOR'S RESPONSIBILITY FOR SAFETY: LEGEND 0 NEW MAN HOLE Q EXISTING MAN HOLE -w- WATER LINE -s - SANITARY SEWER -CL - CENTERLINE 0 WATER SERVICE C -C CENTER TO CENTER IN SUBMITTING A BID FOR THIS WORK, THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER, THE ENGINEER AND THE CITY OF FONTANA HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER, THE ENGINEER, OR THE CITY OF FONTANA. BASIS ❑ F BEARING: THE CENTERLINE OF CITRUS AVENUE BEING N. 00.04'00' E. AS SHOWN ON TRACT NO, 12390 RECORDED IN MAP BOOK 171, PAGES 71-73, SAN BERNARDINO COUNTY RECORDS. BENCHMARK: TOP OF F,H, a NW CORNER, INTERSECTION OLENDER & MILLER ELEVATION = 1353.24 Q O o DIAL TWO WORKING BEFORE DAYS BEFORE YOU DIG YOU DIG TOLL FREE 1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT REV. REVISION DESCRIPTION DATE ENGR. CITY DATE RECORD D R fl w l mc, 11s os CTX W � MIL ER AVE. w W N < Cy C!� A 0 W U LJ 0- O U FOOTHILL BL D. ABBREVIATI❑NS VCP EXTRA -STRENGTH VITRIFIED CLAY PIPE SMH SEWER MAN HOLE INV INVERT ELEVATI❑N EXS'T EXISTING VICINITY AP �1�--- CONSTRUCT 8" VCP SEWER CONSTRUCT SEWER MANHOLE PER CITY ST'D DETAIL 112 W/ FRAME & COVER PER CITY ST'D DETAIL 109 CONSTRUCT 4" SEWER LATERAL PER CITY ST'D DETAIL 125 4*-- BREAK INTO EXISTING SEWER MANHOLE & JOIN l�m QUANTITIES ESTIMATES AREA PROVIDED FOR THE INFORMATION AND CONVENIENCE OF THE DEVELOPER ONLY. THE PIPELINE CONTRACTOR IS RESPONSIBLE FOR ACCURATELY ESTIMATING QUANTITIES OF ALL CONSTRUCTION ITEMS AND MATERIALS REQUIRED FOR THE COMPLETION OF THE PROJECT. PRIVATE ENGINEER'S NOTICE TO CONTRACTORS: THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT SHOWN ON THIS MAP. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES AS SHOWN AND ANY OTHER LINES NOT OF RECORD OR NOT SHOWN ON THIS DRAWING. PRIOR TO EXCAVATION, THE CONTRACTOR SHALL CALL TOLL FREE, 1-800-422-4133 TO VERIFY THE UNDERGROUND LOCATION OF GAS AND TELEPHONE LINES AT LEAST 48 HOURS PRIOR TO THE START OF EXCAVATION, SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT. 1. K00B S, 3-3� 0� 5 D RECORD DRAWING Prepared Under The Supervision Of C.T.K., INC. CONSULTING ENGINEERS 8880 BENSON AVE. SUITE 100 MONTCLAIR, CALIFORNIA 91763 (9.09) 949-1791 (909) 949-8433 FAX �n r� I )<✓W Date CARL T, KOBBINS, IR RCE 13669 EXP 3-31-05 D 0 546 L.F. 3 EA. 15 EA. 1 EA. CITY OF FONTANA, CALIFORNIA SEWER IMPROVEMENT PLAN DRAWN BY: J, R. TRACT NO. 16182 SCALE:: N, A DESIGNED BY: LEMON STREET DATE:----- C.K. FOgTANA, ORNIA 92336 4-_16--02 FCHECKED BY: _,.APP VED Y:©� DRAWING NO.: 1 ` iry r�in�n�rro o r r rl11rle) nnTV. 31 18 1 2 BA ELINE AVE, LJ LJ Q a W d SITE W � MIL ER AVE. w W N < Cy C!� A 0 W U LJ 0- O U FOOTHILL BL D. VICINITY AP �1�--- CONSTRUCT 8" VCP SEWER CONSTRUCT SEWER MANHOLE PER CITY ST'D DETAIL 112 W/ FRAME & COVER PER CITY ST'D DETAIL 109 CONSTRUCT 4" SEWER LATERAL PER CITY ST'D DETAIL 125 4*-- BREAK INTO EXISTING SEWER MANHOLE & JOIN l�m QUANTITIES ESTIMATES AREA PROVIDED FOR THE INFORMATION AND CONVENIENCE OF THE DEVELOPER ONLY. THE PIPELINE CONTRACTOR IS RESPONSIBLE FOR ACCURATELY ESTIMATING QUANTITIES OF ALL CONSTRUCTION ITEMS AND MATERIALS REQUIRED FOR THE COMPLETION OF THE PROJECT. PRIVATE ENGINEER'S NOTICE TO CONTRACTORS: THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT SHOWN ON THIS MAP. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES AS SHOWN AND ANY OTHER LINES NOT OF RECORD OR NOT SHOWN ON THIS DRAWING. PRIOR TO EXCAVATION, THE CONTRACTOR SHALL CALL TOLL FREE, 1-800-422-4133 TO VERIFY THE UNDERGROUND LOCATION OF GAS AND TELEPHONE LINES AT LEAST 48 HOURS PRIOR TO THE START OF EXCAVATION, SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT. 1. K00B S, 3-3� 0� 5 D RECORD DRAWING Prepared Under The Supervision Of C.T.K., INC. CONSULTING ENGINEERS 8880 BENSON AVE. SUITE 100 MONTCLAIR, CALIFORNIA 91763 (9.09) 949-1791 (909) 949-8433 FAX �n r� I )<✓W Date CARL T, KOBBINS, IR RCE 13669 EXP 3-31-05 D 0 546 L.F. 3 EA. 15 EA. 1 EA. CITY OF FONTANA, CALIFORNIA SEWER IMPROVEMENT PLAN DRAWN BY: J, R. TRACT NO. 16182 SCALE:: N, A DESIGNED BY: LEMON STREET DATE:----- C.K. FOgTANA, ORNIA 92336 4-_16--02 FCHECKED BY: _,.APP VED Y:©� DRAWING NO.: 1 ` iry r�in�n�rro o r r rl11rle) nnTV. 31 18 1 2