Loading...
HomeMy WebLinkAbout3081-11 ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK'). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED. 2 WHEN TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION. 3 ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER. 4 CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVE- LOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 5 THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. 6 IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL AT ALL TIMES. 7 THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. 8 THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXIST FOR GROUND MOVEMENT. 9 NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT-OF-WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE. 10 THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION. HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION. 11 THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES. 12 THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS. 13 STATIONING REFERS TO THE CENTERLINE OF SEWER EXCEPT WHERE OTHERWISE NOTED. 14 ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION. 15 THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER. 16 REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT. 17 THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 18 THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES. 19 THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT-OF-WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL. 20 NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 21 A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED. 22 CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS. 23 ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE. 24 IF SEWER CONSTRUCTION IS TO BE DONE IN PHASES, THE CONTRACTOR SHALL PROVIDE A TERMINAL CLEANOUT AT THE PHASE BOUNDARY, NOT MORE THAN 150 FEET FROM THE DOWN STREAM MANHOLE, SEE CITY OF FONTANA STANDARD DETAIL FOR TERMINAL CLEANOUT. 25 SANITARY SEWER LINES SHALL BE CONSTRUCTED OF BELL AND SPIGOT OR BAND SEAL TYPE VITRIFIED CLAY PIPE (V.C.P.) EXTRA STRENGTH CLASS AND SHALL CONFORM TO THE PROVISIONS OF THE ASTM DESIGNATION C700 FOR V.C.P.. 26 NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE CITY ENGINEER. 27 SHORT VCP STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED AT MANHOLE WALLS TO ALLOW FOR MINOR DEFLECTIONS IN ALIGNMENT. 28 PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS. 29 ALL 4" HOUSE LATERALS SHALL BE INSTALLED AT A 27. MINIMUM GRADE UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER. 30 TERMINATE ALL 4" HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH A PLUG 12" BELOW THE GROUND SURFACE. WHEN PUBLIC UTILITY EASEMENTS EXIST NEXT TO THE STREET RIGHT-OF-WAY, THE LATERAL SHALL TERMINATE 3 FEET INSIDE THE LOT AS MEASURED FROM THE UTILITY EASEMENT. 31 THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE CURB AT THE LOCATION OF THE SEWER LATERAL. 32 IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY. 33 NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. 34 ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS. 35 APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT 36 ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISE TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING 37 UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNIN(b STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER. 38 AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER. SEWER IMPROVEMENT PLANS TRACT 11006 ITY OF _ FQ NTANA UTILITY N OTI FI CATI 0 N CITY OF FONTANA PACIFIC BELL CO. ATTN: CARLOS NAVARRO ATTN: VIRGINIA BECKER 8353 SIERRA AVENUE 3939 E.CORONADO STREET FONTANA, CA 92335 ANAHEIM, CA 92807 (909) 350-6632 (714) 666-5467 SO. CALIFORNIA GAS COMPANY COMCAST (CABLE TV) ATTN: GREG GASPAR ATTN: JACK HAYES 16231 VALLEY BLVD. 1205 DUPONT AVENUE FONTANA, CA. 92335 ONTARIO, CA. 91761 428-1 (909) 390-4738 EM� R)GENCIES4 (800) 427-2200 Q SO. CALIFORNIA EDISON COMPANY > 7951 REDWOOD AVE. > FONTANA, CA. 92335 909820-5598 — UNDERGROUND 3RD SUBMITTAL 909 875-5100 — TRANSMISSIONS Q 213 637-1233 — PIPELINES FONTANA WATER COMPANY 909 357-6233 — DISTRIBUTION ATTN: MICHAEL J. McGRAW 800 422-4133 8440 NUEVO AVENUE CRAWFORD CANYON MUTUAL WATER CO. (909) 822-2201 ATTN. BILL VANDERKIEFT, JR. FAX: (909) 823-5046 (619) 868-6040 UNDERGROUND SERVICE ALERT (800) 227-2600 PRIVATE ENGINEER'S NOTICE TO CONTRACTOR THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS; TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND RESPON— SIBILITY FOR THE UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN OR NOT SHOWN ON THESE DRAWINGS. THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONS— IBILITY FOR THE JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT; INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL REPORT ALL DISCREPANCIES TO THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK. TOLL FREE -800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT TRACT NO.11006 INDEX MAP 1 "=100' CONSTRUCTION NOTES & QUANTITIES O 0 u w J Q U In 0 O INSTALL 8" V.C.P. ( EXTRA STRENGTH) SEWER MAIN. 1423 LF OINSTALL 4 V.C.P. EXTRA STRENGTH SEWER LATERAL PER CITY OF FONTANA PER CITY OF FONTANA STD. DWG. NO. 125. 1262 LF/40EA OCONSTRUCT PRECAST CONCRETE MANHOLE PER CITY OF FONTANA STD. DWG. NO. 112 I.D.=48" . 4 EA O CONSTRUCT SEWER TERMINAL CLEANOUT PER CITY OF FONTANTA STD. DWG. 128 2 EA -6 NO. 4 0-15 N0. 8 0-5 ASTM C 131 TEST GRADING NOTE: NO BACKFLOW PREVENTORS ARE REQUIRED IN THIS TRACT TABLE: 200-1.2 A SIEVE SIZE PERCENTAGE PASSING SIEVES 1 1 - 1 S No. 62183 N + Exp: 9-30-05RANCHO � C/ V %�- rFOFCgL\EOE 4 1 0 1 2 90-1 0 348- -6 NO. 4 0-15 N0. 8 0-5 ASTM C 131 TEST GRADING B RECORD DRAWING 1 THESE RECORD DRAWINGS HAVE BEEN PREPARED, IN PART, ON THE BASIS OF INFORMATION COMPILED ARID FURNISHED BY OTHERS. THE ENGINEER WILL NOT BE RESPONSIBLE FOR ANY ERRORS OR OMISSIONS WHICH ! HAVE BEEN INOORPORIITED KM THE DOCUMENTS AS !f A RESULT THEREOF NOTE: ADD 1300 TO ALL ELEVATIONS SHOWN REV. REVISION DESCRIPTION DATE ENGR. CITY DATE S No. 62183 N + Exp: 9-30-05RANCHO � C/ V %�- rFOFCgL\EOE MADOLE AND ASSOCIATES, INC. 10601 CHURCH STREET, STE. 107 CUCAMONGA, CA 91730 PHONE (909) 948-1311 Date : 2--lA •oma B.C. BEGIN CURVE SEWER IMPROVEMENT PLANS T 11006 SHEET DESIGNED BY: :DZ CATCH BASIN w w � w 4 FINAL SUBMITTAL Q Q > > 2/25 > Q 3 3RD SUBMITTAL 1/28 Q F.G. Q 2 2ND SUBMITTAL 12/4 Q 1 1 ST SUBMITTAL 9/12 G.B. Q SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL ? SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND I STANDARDS IN EFFECT. 6" MIN. 1 r1" AAAX 3" MAX. SIZE NATIVE SOIL — COMPACTED 95%. 6" MAX. SIZE — NATIVE SOIL COMPACTED 90%. 10' OR DEEPER USE 1/2" CRUSHED STONE BEDDING PER STD. SPECS. FOR — PUBLIC WORKS CONSTRUCTION TABLE 200 1.2 [A]. /� SITE VICINITY MAP NTS R/W CURB LINE--,,,., rl 00 STREET C.L� S - SEWER MAI a 8' MIN. 10� ' AVG. ;.�L--3' MIN, 5' MAX. r%[ M -r SEWER LATERAL Ir) w w WATER LAT. & SERVICE METER BY FONTANA WATER COMPANY S TYPICAL SEWER LATERAL & WATER SERVICE DETAIL NTS 6" MIN. 10" MAX. 1 " MAX. SIZE SELECTED NATIVE BEDDING COMPACTED TO 90%. TYPICAL BEDDING DETAIL N.T.S. BENCH MARK: 360 CITY OF FONTANA BENCH MARK. NAIL IN POLE #1536704E AT SOUTH WEST CORNER OF LIME AVENUE AND BASELINE ROAD ELEVATION: 1376.09 BASIS OF BEARINGS: THE BASIS OF BEARINGS FOR THIS MAP IS NO'02'39"W. BEING THE CENTERLINE OF ALMERIA AVENUE AS SHOWN ON PARCEL MAP 3218, P.M.B. 29/15 WAS USED. ABBREVIATIONS & LEGEND A. B. BASELINE ROAD A.C. w S No. 62183 N + Exp: 9-30-05RANCHO � C/ V %�- rFOFCgL\EOE MADOLE AND ASSOCIATES, INC. 10601 CHURCH STREET, STE. 107 CUCAMONGA, CA 91730 PHONE (909) 948-1311 Date : 2--lA •oma B.C. BEGIN CURVE SEWER IMPROVEMENT PLANS T 11006 SHEET DESIGNED BY: :DZ CATCH BASIN w w � w Li Q Q > > Q > Q F. F. MILLER Q Q F.G. Q AVENUE F. L. Q F.S. FINISH SURFACE G.B. Q w H.P. HIGH POINT INV. J � M.P.S.D. MASTER PLAN STORM DRAIN P.C.C. � J P.R.C. POINT OF REVERSE CURVATURE P.V.C. In LINE RRCRIDGE P. FOOTHILL R/W RIGHT OF WAY BOULEVARD U Q co W TOP OF FOOTING 0 w Q :D ry Z W � Y G✓ r V VERTICAL DEPTH = ARROW aJ V.C. U AVENUE L) (590.77) INDICATES EXISTING ELEVATION tjJ VICINITY MAP NTS R/W CURB LINE--,,,., rl 00 STREET C.L� S - SEWER MAI a 8' MIN. 10� ' AVG. ;.�L--3' MIN, 5' MAX. r%[ M -r SEWER LATERAL Ir) w w WATER LAT. & SERVICE METER BY FONTANA WATER COMPANY S TYPICAL SEWER LATERAL & WATER SERVICE DETAIL NTS 6" MIN. 10" MAX. 1 " MAX. SIZE SELECTED NATIVE BEDDING COMPACTED TO 90%. TYPICAL BEDDING DETAIL N.T.S. BENCH MARK: 360 CITY OF FONTANA BENCH MARK. NAIL IN POLE #1536704E AT SOUTH WEST CORNER OF LIME AVENUE AND BASELINE ROAD ELEVATION: 1376.09 BASIS OF BEARINGS: THE BASIS OF BEARINGS FOR THIS MAP IS NO'02'39"W. BEING THE CENTERLINE OF ALMERIA AVENUE AS SHOWN ON PARCEL MAP 3218, P.M.B. 29/15 WAS USED. ABBREVIATIONS & LEGEND A. B. AGGREGATE BASE CITY OF FONTANA, CALIFORNIA A.C. ASPHALTIC CONCRETE S No. 62183 N + Exp: 9-30-05RANCHO � C/ V %�- rFOFCgL\EOE MADOLE AND ASSOCIATES, INC. 10601 CHURCH STREET, STE. 107 CUCAMONGA, CA 91730 PHONE (909) 948-1311 Date : 2--lA •oma B.C. BEGIN CURVE SEWER IMPROVEMENT PLANS T 11006 SHEET DESIGNED BY: C. B. CATCH BASIN RCE 6218 EXP. 9-30-05 CITY ENGINEER R.C.E. 51152 DATE C.L. CENTERLINE E.C. END CURVE E.D.F. EXTRA DEPTH FOOTING F. F. FINISH FLOOR F.G. FINISH GRADE F. L. FLOW LINE F.S. FINISH SURFACE G.B. GRADE BREAK H.P. HIGH POINT INV. INVERT M.P.S.D. MASTER PLAN STORM DRAIN P.C.C. PORTLAND CEMENT CONCRETE P.R.C. POINT OF REVERSE CURVATURE P.V.C. POLYVINYL CHLORIDE LINE RRCRIDGE P. REINFORCED CONCRETE PIPE R/W RIGHT OF WAY T.C. TOP OF CURB T. F. TOP OF FOOTING T.G. T.W. TOP OF GRATE TOP OF WALL Z W WIDTH V VERTICAL DEPTH V.C. VERTICAL CURVE (590.77) INDICATES EXISTING ELEVATION tjJ 590.77 INDICATES PROPOSED ELEVATION 610 INDICATES EXISTING CONTOUR 610 INDICATES PROPOSED CONTOUR 0 INDICATES RETAINING WALL cr DAYLIGHT / CUT—FILL LINE INDICATES SLOPE > 4 : 1 SCALE: Prepared Under The Supervision Of : CITY OF FONTANA, CALIFORNIA QR�,� PREPARED IN THE OFFICE OF S No. 62183 N + Exp: 9-30-05RANCHO � C/ V %�- rFOFCgL\EOE MADOLE AND ASSOCIATES, INC. 10601 CHURCH STREET, STE. 107 CUCAMONGA, CA 91730 PHONE (909) 948-1311 Date : 2--lA •oma DRAW BY: MJG SEWER IMPROVEMENT PLANS T 11006 SHEET DESIGNED BY: CHECKED BY: � M LB APP D BY• Z Z '7. p'� RCE 6218 EXP. 9-30-05 CITY ENGINEER R.C.E. 51152 DATE SCALE: DATE: FEB, 2002 V DRAWING NO.: 1 3081 3 JA692-1430\sewer\SEW01.dwg, 02/25/2002 03:45:44 PM, mjg