HomeMy WebLinkAbout3076-1GENERAL NOTES
1 ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF
FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD
SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK"). ALL
REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION
UNLESS OTHERWISE NOTED.
2 WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT
DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE
PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY
REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION.
3 ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF TILE
CITY ENGINEER.
4 CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA
COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE
START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT
LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC
RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610.
5 THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES,
METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL
OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE
DIRECTED BY THE CITY TRAFFIC ENGINEER.
6 IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN
BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL
TIMES.
7 THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR
TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE
CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
8 THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET
IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR
OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION
OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN
FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR
GROUND MOVEMENT.
9 NO MATERIAL OR EQUIPMENT SHALL BE STORED IN TILE PUBLIC RIGHT OF
WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE.
10 THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM
AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND
ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION
TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND
SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE
EXCAVATION.
11 THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY
COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC,
CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER,
RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS.
ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR
TO WORK AROUND THEIR FACILITIES.
12 THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER
MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR
SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE
OPERATION AND WATER REQUIREMENTS.
13 STATIONING REFERS TO THE CENTERLINE OF SEWER EXCEPT WHERE
OTHERWISE NOTED.
14 ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE
ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO TILE
PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE
PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING
DURING CONSTRUCTION.
15 THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS,
MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY
ENGINEER.
16 REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING
SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE
BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY
MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION
SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE
WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE
ESTABLISHED FOR LATER REPLACEMENT OF TILE MONUMENT.
17 THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND
BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED
AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY
VEHICLES.
18 THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF
DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES.
19 THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT
OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT
TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN
APPROVAL.
20 NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF
THE CITY INSPECTOR.
21 A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION.
FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF
THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED.
22 CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES
FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE,
THE CITY ENGINEER MAY REQUIRE TEMPORARY NONERODEABLE SWALES
ENTERING OR LEAVING IMPROVEMENTS.
23 ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR
AND FINISH TO MATCH EXISTING CONCRETE.
24 IF SEWER CONSTRUCTION IS TO BE DONE IN PHASES, THE CONTRACTOR
SHALL PROVIDE A TERMINAL CLEANOUT AT THE PHASE BOUNDARY, NOT MORE
THAN 150 FEET FROM THE DOWNSTREAM MANHOLE, SEE CITY OF FONTANA
3 STANDARD DETAIL FOR TERMINAL CLEANOUT.
N
0
0
N
,.z
SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS
LkX18r9r0U 1d SGr*0 Abrt NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF
APPROVAL SHOWN HEREON AND CARRIED FORTH IN A
C 1D TOLL FfEE DILIGENT MANNER THE CITY ENGINEER MAY REQUIRE
o REVISIONS TO THE PLANS TO BRING THEM INTO
L�— CONFORMANCE WITH CONDITIONS AND STANDARDS
a227-26M IN EFFECT.
TWO WWOW DAYS BEFORE You DIG I
25 SANITARY SEWER LINES SHALL BE CONSTRUCTED OF BELL AND SPIGOT OR
BAND SEAL TYPE VITRIFIED CLAY PIPE (V.C.P.) EXTRA STRENGTH CLASS AND
SHALL CONFORM TO THE PROVISIONS OF THE ASTM DESIGNATION C700 FOR
V.C.P.
26 NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT
PRIOR APPROVAL OF THE CITY ENGINEER.
27 SHORT VCP STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED
AT MANHOLE WALLS TO ALLOW FOR MINOR DEFLECTIONS IN ALIGNMENT.
28 PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING
FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY
APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY
CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS.
29 ALL 4" HOUSE LATERALS SHALL BE INSTALLED AT A 2% MINIMUM GRADE
UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER.
30 TERMINATE ALL 4" HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH
A PLUG 12" BELOW THE GROUND SURFACE. WHEN PUBLIC UTILITY EASEMENTS
EXIST NEXT TO THE STREET RIGHT OF WAY, THE LATERAL SHALL TERMINATE 3
FEET INSIDE THE LOT AS MEASURED FROM THE UTILITY EASEMENT.
31 THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE
CURB AT THE LOCATION OF THE SEWER LATERAL.
32 IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE
PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER
AND ALL AFFECTED AGENCIES IMMEDIATELY.
33 NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING
STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED.
34 ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED
PRIOR TO PAVING OF STREETS.
35 APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT
PAVEMENT PRIOR TO PLACEMENT.
36 ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE
RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION
OF PAVING.
37 UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL
SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO
THE SATISFACTION OF THE CITY TRAFFIC ENGINEER.
38 AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE
ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY
ENGINEER.
CRY OF FOr TM& UTLITY N01 RCATM LIST
CITY OF FONTANA
PACIFIC BELL CO.
ATTN: CARLOS NAVARRO
ATTN: VIRGINIA BECKER
8353 SIERRA AVENUE
3939 E. CORONADO STREET
FONTANA, CA. 92335
ANAHEIM, CA. 92807
(909) 350-6632
(714) 666-5467
SO. CALIF. GAS COMPANY
UNDERGROUND SERVICE ALERT
ATTN: DENNIS FREEMAN
(800) 227-2600
1981 W. LUGONIA AVENUE
0-5
REDLANDS, CA. 92374
COMCAST ( CABLE TV )
(909) 335-7547
ATTN: JACK HAYES
EMERGENCIES: (800) 427-2200
1205 DUPONT AVE.
ONTARIO, CA. 91761
SO. CALIF. EDISON COMPANY
(909) 390-4738
300 N. PEPPER AVENUE
RIALTO, CA. 92376
GENERAL TELEPHONE COMPANY
909 820-5598 - UNDERGROUND
ATTN: STEVE HOCK
909 875-5100 - TRANSMISSION
1400 E. PHILLIPS BLVD.
213 637-1233 - PIPELINES
ONTARIO, CA. 91766
909 357-6223 - DISTRIBUTION
(800) 422-4133
800 422-4133
FONTANA WATER COMPANY T
CRAWFORD CANYON MUTUAL WATER CO.
ATTN: MICHAEL J. MCGRAW b
ATTN: BILL VANDERKIEFT, JR.
8440 NUEVO AVENUE D
(619) 868-6040
FONTANA CA. 92235
(909) 822-2201 a
FAx: (909) 823-5046 n
LEGEND
0� STREET LIGHTS
DIRECTION OF FLOW
—� FIRE HYDRANT
PLANS PREPARED FOR
CENTEX HOMES
2280 WARDLOW CIRCLE
SUITE 150
CA. 92880
CORONA,
(909) 279-4000
ARECORD DOCUMENT
CITY OF FONTANA
SEWER IMPROVEMENT PLANS
hese Record Documents have been prepared
ased on information provided by others. The
esign Professional has not verified the accuracy
nd/or completeness of this information and shall
of be responsible for any errors or omissions
Whiclj may be incorporated herein as a result
if
12.
DATE
NOTE:
SEWER PLANS WILL NOT BE BUILT IN
STAGES.
FOR
TRACT 16085
INDEX MAP
SCALE: 1 "=200'
CONSTRUCTION NOTES ESTIMATE OF QUANTITIES
10---- CONSTRUCT SEWER TERMINAL CLEANOUT PER CITY STD. 126
2O --CONSTRUCT PRECAST CONCRETE MANHOLE PER CITY STD. DWG. NO. 112
30--- CONSTRUCT 4" VCP EXTRA STRENGTH SEWER LATERAL & CLEANOUT PER
CITY STD. DWG. NO. 112 (SEE GENERAL NOTE NO. 30)
4�-CONSTRUCT 8" VCP EXTRA STRENGTH SEWER MAIN
50--- INSTALL BACKFLOW CHECK VALVE
60-- INSTALL 8" D.I.P. SEWER MAIN
W, Jr n1/117! ■�►�7 ���E !1�i1/�/
BENCHMARK
B.M. #361, SPIKE IN NORTH FACE OF P.P.
#1536697E AT SOUTH WEST CORNER OF
BASELINE AVENUE AND SULTANA AVENUE.
ELEVATION: 1365.01
1 EA.
13 EA.
2,896 L.F.
92 EA.
2,293 L.F.
41 EA
1,179 L.F.
Prepared By:
ALLARD ENGINEERING
Civil Engineering - Land Surveying - Land Planning
8253 Sierra Avenue I
Fontana, California 92335
31
-1815 Fax (9M) 356-1795
3 -Tie, -oz_
David . Hammer, (OR.. �5 43976 Date
VICINITY
MAP
Project Location
3" MAX SIZE NATIVE
SOIL, COMPACTED 95%
6" MIN. 6" MIN.
10" MAX. 10" MAX.
FNAT
6" MAX SIZE NATIVESOIL, COMPACTED 90%SIZE SELECTED
EDDING COMPACTED
8" VCP
N
TYPICAL BEDDING FOR 8' VCP
LESS THAN 10' DEEP
SCALE: 1 " = 2'
3" MAX SIZE NATIVE
SOIL, COMPACTED 95%
6" MIN.
10" MAX. ~
t:4 -11I -
1I
6" MAX SIZE NATIVE -
SOIL, COMPACTED 90%
1/2" CRUSHED -
STONE BEDDING
PER STD. SPECS.
FOR PUBLIC WORKS
CONSTRUCTION
TABLE 200-1.2(A)
SHOWN BELOW
TABLE: 200-1.2(A)
SIEVE SIZE
PERCENTAGE
PASSING SIEVES
1 1/2-
I
1"
—
3/4"
100
1/2"
90-100
3/8"
c0
-- J
F—
N0.8
INDEX MAP
SCALE: 1 "=200'
CONSTRUCTION NOTES ESTIMATE OF QUANTITIES
10---- CONSTRUCT SEWER TERMINAL CLEANOUT PER CITY STD. 126
2O --CONSTRUCT PRECAST CONCRETE MANHOLE PER CITY STD. DWG. NO. 112
30--- CONSTRUCT 4" VCP EXTRA STRENGTH SEWER LATERAL & CLEANOUT PER
CITY STD. DWG. NO. 112 (SEE GENERAL NOTE NO. 30)
4�-CONSTRUCT 8" VCP EXTRA STRENGTH SEWER MAIN
50--- INSTALL BACKFLOW CHECK VALVE
60-- INSTALL 8" D.I.P. SEWER MAIN
W, Jr n1/117! ■�►�7 ���E !1�i1/�/
BENCHMARK
B.M. #361, SPIKE IN NORTH FACE OF P.P.
#1536697E AT SOUTH WEST CORNER OF
BASELINE AVENUE AND SULTANA AVENUE.
ELEVATION: 1365.01
1 EA.
13 EA.
2,896 L.F.
92 EA.
2,293 L.F.
41 EA
1,179 L.F.
Prepared By:
ALLARD ENGINEERING
Civil Engineering - Land Surveying - Land Planning
8253 Sierra Avenue I
Fontana, California 92335
31
-1815 Fax (9M) 356-1795
3 -Tie, -oz_
David . Hammer, (OR.. �5 43976 Date
VICINITY
MAP
Project Location
3" MAX SIZE NATIVE
SOIL, COMPACTED 95%
6" MIN. 6" MIN.
10" MAX. 10" MAX.
FNAT
6" MAX SIZE NATIVESOIL, COMPACTED 90%SIZE SELECTED
EDDING COMPACTED
8" VCP
N
TYPICAL BEDDING FOR 8' VCP
LESS THAN 10' DEEP
SCALE: 1 " = 2'
3" MAX SIZE NATIVE
SOIL, COMPACTED 95%
6" MIN.
10" MAX. ~
t:4 -11I -
1I
6" MAX SIZE NATIVE -
SOIL, COMPACTED 90%
1/2" CRUSHED -
STONE BEDDING
PER STD. SPECS.
FOR PUBLIC WORKS
CONSTRUCTION
TABLE 200-1.2(A)
SHOWN BELOW
TABLE: 200-1.2(A)
SIEVE SIZE
PERCENTAGE
PASSING SIEVES
1 1/2-
—
1"
—
3/4"
100
1/2"
90-100
3/8"
20-60
NO.4
0-15
N0.8
0-5
ASTM C 131
TEST GRADING
B
Ad
c�
� Z
No. 43976 m
a Exp. 6/30/05
CIvo-
'F C � 1
0
8" VCP
6" MIN.
10" MAX.
1 " MAX. SIZE SELECTED
NATIVE BEDDING COMPACTED
TO 90%
2 z
W o
MIN a 0
0
TYPICAL BEDDING FOR 8' VCP
10' OR DEEPER
SCALE: 1 " = 2'
� CITY OF FONTANA s CALIFORNIA I
r SEWER IMPROVEMENT PLANS I
Drawn By: Scale:
JK AS NOTED
Designed By: _ - CT NO.16085
JF Date:
2002
Checked By: �- _10? Dwg. No.
Approved:
DSH TY ENGINEER R.C.E. 51152 30%6 s
Filename: M:\DWG\12704\PHASE-2\SEWER\SWR-1