HomeMy WebLinkAbout3075-11. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS,
THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS
AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION
("GREEN BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS
SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED.
2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT
DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO
PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR
SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR
RESOLUTION.
3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF
THE CITY ENGINEER.
4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF
FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION
PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL
BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF
ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL
(909) 350-7610.
5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL
POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF
CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC
EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER.
6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN
BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT
ALL TIMES.
7. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM
EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN
DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
8. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5)
FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE
GROUND OR OTHER APPROVED MEANS PURSUANT TO THE
REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE
OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE
GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT.
9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC
RIGHT OF WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT
PURPOSE.
10. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED
FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE
TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO
EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE
CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT
1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION.
11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL
UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE,
ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION,
DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD
CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO
WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES.
12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR
WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION.
CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER
COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS.
13. CURVE DATA REFERS TO THE FACE OF CURB.
14. STATIONING REFERS TO THE CENTERLINE OF STREETS EXCEPT
WHERE OTHERWISE NOTED.
15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE
ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO
THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE
PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING
DURING CONSTRUCTION.
16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY
MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR
NOTIFICATION TO THE CITY ENGINEER.
17. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL,
INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS,
SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND
SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A
RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR
SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO
THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER
REPLACEMENT OF THE MONUMENT.
18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS
AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE
MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS
AND EMERGENCY VEHICLES.
19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE
MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL
TIMES.
20. ALL GRADING OPERATIONS SHALL BE DISCONTINUED WHEN
SUSTAINED WIND VELOCITIES EXCEED 25 MILES PER HOUR
21. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED
MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR
PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING
CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL.
22. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL
OF THE CITY INSPECTOR.
23. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL
COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL
REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE
SPECIFIED DENSITY IS OBTAINED.
24. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND
SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION
OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY
NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS.
25. THE FINAL LOCATION AND WIDTH OF DRIVEWAY APPROACH APRONS
SHALL BE APPROVED AT THE TIME OF CONSTRUCTION AND SHALL
CONFORM TO THE CITY OF FONTANA STANDARD DETAILS.
26. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE,
COLOR AND FINISH TO MATCH EXISTING CONCRETE.
27. THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF
THE CURB AT THE LOCATION OF THE SEWER LATERAL.
28. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND
REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED.
29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND
APPROVED PRIOR TO PAVING OF STREETS.
30. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW
ASPHALT PAVEMENT PRIOR TO PLACEMENT.
31. PAVEMENT STRUCTURAL SECTIONS SHOWN ARE MINIMUM AND
SUBJECT TO REVISION AND APPROVAL OF THE CITY ENGINEER AS
DETERMINED BY SOILS TESTS TAKEN AFTER COMPLETION OF ROUGH
GRADING.
32. ACTUAL THICKNESS OF A.C. PAVEMENT AND/OR BASE COURSE
MATERIAL FOR STRUCTURAL STREET SECTIONS SHALL BE RECOMMENDED
BY A GEOTECHNICAL REPORT AND SUBMITTED TO THE CITY OF FONTANA
FOR APPROVAL UPON COMPLETION OF ROUGH GRADING.
33. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES
SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR
UPON COMPLETION OF PAVING.
34. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE
ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL
DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER.
35. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING,
SPRINKLERS AND SIDEWALKS AFFECTED BY THE CONSTRUCTION TO THE
SATISFACTION OF THE CITY ENGINEER.
36. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO
THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO
THE CITY ENGINEER.
• • • JI--- ,� _sem _ t.��. _mil
CITY OF FONTANA
STREET IMPROVEMENT PLANS
CITY OF FONTANA
PACIFIC BELL CO.
ATTN: CARLOS NAVARRO
ATTN: VIRGINIA BECKER
8353 SIERRA AVENUE
3939 E. CORONADO STREET
FONTANA, CA. 92335
ANAHEIM, CA. 92807
(909) 350-6632
(714) 666-5467
SO. CALIF. GAS COMPANY
UNDERGROUND SERVICE ALERT
ATTN: DENNIS FREEMAN
(800) 227-2600
1981 W. LUGONIA AVENUE
REDLANDS, CA. 92374
)
COMCAST ( CABLE TV(909)
335-747
1 JACK HAYES
EMERGENCIES: (800) 427-2200
05 DUPONT AVE.
ONTARIO, CA. 91761
SO. CALIF. EDISON COMPANY
(909) 390-4738
300 N. PEPPER AVENUE
RIALTO, CA. 92376
GENERAL TELEPHONE COMPANY
909820-5598 - UNDERGROUND
ATTN: STEVE HOCK _=
909 875-5100 - TRANSMISSION
1400 E. PHILIPS BLVD. -- ,
213 637-1233 - PIPELINES
ONTARIO, CA. 91766
909 357-6223 - DISTRIBUTION
(800) 422-4133
800 422-4133
- - - -
FONTANA WATER COMPANY
ATTN: MICHAEL J. McGRAW
8440 NUEVO AVENUE
FONTANA CA. 92235
(909) 822-2201
FAX: (909) 823-5046
CONSTRUCTION NOTES
O1 -- INSTALL 5800 LUMEN HPSV STREET LIGHT (70 WATT; #7) 25 FT. LUMINAIRE HEIGHT POLES
SHALL BE MARBELITE OR APPROVED EQUAL. PER CITY STD. DWG # 1016
O2 - CONSTRUCT 4" AC PAVEMENT (Min.) OVER 12" OF 95% COMPACTED NATIVE MATERIAL
( See general notes 31 and 32)
3� CONSTRUCT 6" PCC CURB AND GUTTER PER CITY STD. DWG. NO. 1003
4 CONSTRUCT PCC CROSS GUTTER AND SPANDREL PER CITY STD. DWG. NO. 104, W=10' _
CONSTRUCT PCC DRIVE APPROACH PER CITY STD. DWG. 102, W=5.5', WIDTH 16'
5'
CONSTRUCT 4" PCC SIDEWALK PER CITY STD. DWG. NO. 1015, W=5.5'
7 CONSTRUCT HANDICAP RAMP PER CITY STD. DWG. NO. 1006
8 ADJUST MANHOLE FRAME & COVER TO GRADE PER CITY STD. 109
9 REMOVE EXISTING TRAFFIC BARRICADE
10 CONSTRUCT TRAFFIC BARRICADE PER CITY STD. DWG. NO. 118
11 INSTALL STOP SIGN PER CITY STD. DWG. NO. 139
12 INSTALL STREET NAME SIGN PER CITY STD. DWG. NO. 139
11�2�,
FOR
TRACT NO. 16085
7oft I ox07 on I I su r 114 I 77F:T „s I ion
ESTIMATE OF QUANTITIES
17 EA
103,126 SF
5,818 LF
1,691 SF
10,918 SF
31,061 SF
4 EA
10 EA
4 EA
1 EA
2 EA
2 EA
II)EX MAP
SCALE: 1 "=200'
R/W
i24
LEGEND
STREET LIGHTS
DIRECTION OF FLOW
-� FIRE HYDRANT
RECORD DOCUMENT
These Record Documents have been prepared
based on information provided by others. The
Design Professional has not verified the accuracy
and/or completeness of this information and shall
not be responsible for any errors or omissions
whic may be incorporated herein as a result
12-15
DATE
R/W
1 5'
UP E
TOWNSHIP 1 NORTH, RANGE 6 WEST, SECTION 36
VICINITY MAP
27'
54'
27'
ANA
AVE
PROJECT
OCATION
R/W
5' 1
P E
is 6' 20' 20' 6' is
27-_2 jp�J�EE 2%
----2 --- �LE�VEL LI----2�----- ,
--
R/W
SR UWH
SEENL4N EAPIR PLANS
TYPICAL SECTION
BASELM AVENUE -126' WW
STA. 132+34.37 TO STa W-8990
N.T.S.
Ti -10.5
PERPCITYDDWG E�fO IMsP01�Q3VEMENTS
TYPICAL SECTION
LOCAL STREET -54' R/W
CANDI WOOD WAY
HORIZ: 1" = 10'
VERT: 1 " = 2'
50'
25' 25'
7' 18' 18'
6'
2 0
29' 0
:.-y -----mss- - LEVEL -- -
��
,-2=
LINE -__-2z____
TYPICAL SECTION
BIRCH TREE PLACE, MAGNOLIA PLACE
MYRTLE PLACE, OAK TREE PLACE
PLUM TREE PLACE
LOCAL STREET -50' R/W
HORIZ: 1 " = 10'
VERT: 1 " = 2'
R/W
5' 1
P E
Filename: M:\DWG\12704\PHASE-2\STREETS\St-1.DWG