Loading...
HomeMy WebLinkAbout3060-10 0 N 0 0 N ri J Fr CL ai 0 0 0 CL GENERAL NOTES 1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF 24. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, CITY OF FONTANA FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE COLOR AND FINISH TO MATCH EXISTING CONCRETE. STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE 25. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY LATEST EDITION UNLESS OTHERWISE NOTED. WITHOUT PRIOR APPROVAL OF THE CITY ENGINEER. STORM DRAIN IMPROVEMENT PLANS 2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT 26. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY FOR PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY REPORT SAID CONFLICT THE CITY ENGINEER FOR RESOLUTION. CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS. 3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE 27• IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE CITY ENGINEER. PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER TRACT NO. 16009 AND ALL AFFECTED AGENCIES IMMEDIATELY. 4. ADVANCE CONSTRUCTION SIGNING INDICATING DURATION OF PROJECT SHALL BE IN PLACE ONE WEEK PRIOR TO IMPLEMENTING DETOURS. 5. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 6. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. 7. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES. 8. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. 9. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT. 10. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE. 11. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND THE ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION. 12. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES. 13. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS. 14. STATIONING REFERS TO THE CENTERLINE OF STORM DRAIN EXCEPT WHERE OTHERWISE NOTED. 15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION. 16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCHMARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER. 17. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCHMARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT. 18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES, A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 19. THE CONTRACTORS SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES. 20. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL. 21. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 22. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED. 23. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS. 28. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. 29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS. 30. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT. 31. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING. 32. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER. 33. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER. 34. MINIMUM D -LOAD FOR ALL RCP IS 1350 ApRECORD DOCUMENT These Record Documents have been prepared based on information provided by others. The Design Professional has not verified the accuracy and/or completeness of this information and shall not be responsible for any errors or omissions which may be incorporated herein as a result L_CL_V_ -�-�--�.�� DATE BEARINGS ARE BASED ON THE CENTERLINE OF HEMLOCK AVENUE, BEING THE EAST LINE OF THE WEST 1/2 OF THE SOUTHEAST 1/4, SECTION 35, TOWNSHIP 1 NORTH, RANGE 6 WEST, SAN BERNARDINO BASE AND MERIDIAN, BEING NORTH 00'11'07" EAST AS SHOWN ON A RECORD OF SURVEY RECORDED IN BOOK 108, PAGES 13 THROUGH 27, OFFICIAL RECORDS OF THE COUNTY OF SAN BERNARDINO. PLANS PREPARED FOR SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS UM STRATHAM GROUP NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A 2201 DUPONT DRIVE DILIGENT MANNER THE CITY ENGINEER MAY REQUIRE SUITE 300 REVISIONS TO THE PLANS TO BRING THEM INTO IRVINE, CALIFORNIA 92612 CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT. (949)833-1554 FAX (949) 833-7853 ':■1 :1 I►iii INDEX MAP SCALE: 1 "=120' TITLE SHEET BEARTREE STREET PLAN & PROFILE, LATERAL DETAILS APWA STANDARD DRAWINGS ESTIMATE OF MAN TMES 20 INSTALL 42" RCP (1350-D) 123 L.F. 21 INSTALL 36" PCP (1350-D) 197 L.F. 22 INSTALL 24" RCP (1350-D) 54 L.F. 23 INSTALL 18" RCP (1350-D) 90 L.F. 24 CONSTRUCT MANHOLE PER A.P.W.A. STD PLAN 320-1 2 E.A. 25 INSTALL 30" RCP (1350-D) 284 L.F. 26 REMOVE EXIST. 18" CMP AND CMP RISER 1 E.A. CONSTRUCT JUNCTION STRUCTURE PER A.P.W.A. STD. PLAN 321-1 1 E.A. 28 CONSTRUCT JUNCTION STRUCTURE PER A.P.W.A. STD. PLAN 332-1 1 E.A. REVISIONa Engineer City BENCHMA K Approval Date: Approval Date: BRASS CAP IN CONCRETE S.C.E. TOWER LEG. 343' N/0 HIGHLAND AVE., 0.2 MI. W/O SAN SEVAINE RD., IN SOUTH CONCRETE BASE OF S.C.E. TOWER 19.5; 2.65 MI. W. ALONG HIGHLAND AVE. FROM SIERRA AVE. ELEVATION 1428.6090 Q000 SS 'T4 q� No. 36052 rrl UAJ r17 ,Di r___ c /ten /nnnA ;%, `r�' CIVIL �P 9TF � CAL�F� A_ 11,;1111111,114111,1111 ►.• 1.�. _ l.•.► �jl CITY OF FONTANA PACIFIC BELL CO. ATTN.: CARLOS NAVARRO ATTN.: VIRGINIA BECKER 8353 SIERRA AVENUE 3939 E. CORONADO STREET FONTANA, CA. 92335 ANAHEIM, CA. 92807 (909) 350-6632 (714) 666-5467 SO. CALIF. GAS COMPANY UNDERGROUND SERVICE ALERT ATTN.: DENNIS FREEMAN (800) 227-2600 1981 W. LUGONIA AVENUE REDLANDS, CA. 92374 ) COMCAST ( CABLE TV(909) 335-747 ATTN.: JACK HAYES EMERGENCIES: (800) 427-2200 1205 DUPONT AVE. Prepared By: ALLARD ENGINEERING Civil Engineering - Land Surveying - Land Planning 8253 Sierra Avenue Fontana, Calii mla 92335 (909) 356-1815 Fax (909) 356-1795 9 Raymond 1. Allard, R.C.E. 36052 Date VICINITY MAP: NTS CITY OF FONTANA, CALIFORNIA STORM DRAIN IMPROVEMENT PLANS Drawn By: TRACT WF 1 RACT NO. 16009 AS NOTED Designed By: TITLE Date: JR MARCH, 2002 Checked By: - Approved: !/ 14-16 Dwg. No. [73 DSH CITY ENGINEER R.C.L. 51152 3 Filename: M:\DWG\12903\16009\STORM DRAIN\ 1 6009 -SD- 1. DWG ONTARIO, CA. 91761 SO. CALIF. EDISON COMPANY (909) 390-4738 300 N. PEPPER AVENUE RIALTO, CA. 92376 GENERAL TELEPHONE COMPANY 909820-5598 - UNDERGROUND ATTN.: STEVE HOCK 909 875-5100 - TRANSMISSION 1400 E. PHILIPS BLVD. 213 637-1233 - PIPELINES ONTARIO, CA. 91766 909 357-6223 - DISTRIBUTION (800) 422-4133 800 422-4133 FONTANA WATER COMPANY ATTN.: MICHAEL J. McGRAW 8440 NUEVO AVENUE FONTANA CA. 92235 (909) 822-2201 FAX: (909) 823-5046 Prepared By: ALLARD ENGINEERING Civil Engineering - Land Surveying - Land Planning 8253 Sierra Avenue Fontana, Calii mla 92335 (909) 356-1815 Fax (909) 356-1795 9 Raymond 1. Allard, R.C.E. 36052 Date VICINITY MAP: NTS CITY OF FONTANA, CALIFORNIA STORM DRAIN IMPROVEMENT PLANS Drawn By: TRACT WF 1 RACT NO. 16009 AS NOTED Designed By: TITLE Date: JR MARCH, 2002 Checked By: - Approved: !/ 14-16 Dwg. No. [73 DSH CITY ENGINEER R.C.L. 51152 3 Filename: M:\DWG\12903\16009\STORM DRAIN\ 1 6009 -SD- 1. DWG