HomeMy WebLinkAbout3047-1CITY OF FONTANA GENERAL NOTES FOR STORM DRAIN IMPROVEMENT PLANS 1. ALL WORK SHALL BE IN. ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK.) ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED. 2. WHEN A TECHNICAL CONFUCT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION. ��1i>�'L1<11;7���:I�l':>Il; � ���;i��T:TfX�i[�jl. �ir':T�I�L�>•� i<l �M�171 t� »�� 4. ADVANCE CONSTRUCTION SIGNING INDICATING DURATION OF PROJECT SHALL BE IN PLACE ONE WEEK PRIOR TO IMPLEMENTING DETOURS. 5. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, EN(*A3MNG DIVISION PRIOR TO THE START OF ANY MARK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 6. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CAUFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. 7. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DEUNEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES. 8. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. 9. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT. 10. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE. 11. THE LOCATIONS OF UTKJTIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBIJTY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTIJTIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION. 12. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CAI_TRANS. ALL UTAJTY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEN FACIUTIES. 13. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS. I . 1 � �,, il�i�it►��� Ij-i���l�i��,�'li�ii���.;t.. �.:._i� . «�i��..i �;t���i �i�..t► ���1>I�� 15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION. 16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER. 17. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT. 18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES, A MINIUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES. 20. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL 21. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 22. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UN11L THE SPECIFIED DENSITY IS OBTAINED. 23. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS. 24. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE. 25. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE CITY ENGINEER. 26. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS. 27. IF EXISTING UTILITIES OR ANY OTHER FACILJTES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY. 28. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. 0 0 DIAL TWO WORKING BEFORE DAYS BEFORE YOU DIG YOU DIG Toll FREE 1-800-227-2600 A PUBLIC SERVICE BY UNDERGR"D SERVICE ALERT CITY OF FONTANA GENERAL NOTES (CONTID) 29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS. 30. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT. 31. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING. 32. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER. 33. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER. 34. MINIMUM D -LOAD FOR ALL RCP IS 1350. op ����� GP 15 / � ON c�0 SUMMIT AVE SUMMIT AVE BFC,y � W W U W PARKWALY.AKES o: mm ,k PROJECT , �.. SITE (:5 HIGHLAND AVE COUNTY OF SAN BERNARDINO THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY. THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE AGENCY AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILTY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE AGENCY OR THE ENGINEER. THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN IN THESE PLANS WERE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN, AND IS RESPONSIBLE FOR THE PROTECTION OF, AND ANY DAMAGE TO THESE LINES OR STRUCTURES. "CAUTION: THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR, OR LIABLE FOR, UNAUTHORIZED CHANGES OR USES OF THESE PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND MUST BE APPROVED BY THE PREPARER OF THESE PLANS." BASIS OF BEARINGS: The basis of bearings for this drawing is the line between the NW Cor. Sec. 25, R6W, T1 N (Pt. 61) and the Northerly quarter cor. of said Sec. 25 (pt 84).Said bearing is N 89'44'05" E as shown on RS 30/58-60. (9-ynN The Bench Mark for this project is Caltrans BM #8-17. It is described as a Brass Cap in the concrete base of the South leg of an SCE tower 343' North of Highland, 0.2 mi WeST of San Sevaine Rd., 2.65 mi WeST of Sierra Ave. Elevation is 1428.609 feet. - -SEMA LAM PARI(WAY SR 210 FREEWAY INDEX IIAP SCALE: 1"=200' CITY OF FONTANA UTILITY NOTIFICATION LIST CITY OF FONTANA 8353 SIERRA AVE FONTANA, CA 92335 ATTN: CARLOS NAVARRO (909) 350-6632 SOUTHERN CAUFORNIA GAS COMPANY P.O. BOX 3003, SC8031 REDLANDS, CA 92373-0306 ATTN: RICKEY REYES (909) 335-7508 (909) 335 7527 (FAX) EMERGENCIES: (800) 427-2200 PACIFIC BELL COMPANY GENERAL TELEPHONE COMPANY SOUTHERN CALIFORNIA EDISON COMPANY STORM DRAIN CONSTRUCTION NOTES do QUANTITIES rEM oEl-I r r! Mfr. 1 CONSTRUCT 36" DIA RCP, D -LOAD PER PLAN 311 LF 2 CONSTRUCT 18" DIA RCP, D -LOAD PER PLAN 109 LF 3 CONSTRUCT TRANSITION STRUCTURE PER APWA STD 340-1.* 1 EA 4 CONSTRUCT CATCH BASIN PER STREET IMPROVEMENT PLAN. 8 EA 5 CONSTRUCT JUNCTION STRUCTURE -PIPE TO PIPE PER APWA STD 331-2.* 4 EA 6 CONSTRUCT MANHOLE -PIPE TO PIPE PER APWA STD 321-1.* 1 EA 7 CONSTRUCT 24" DIA RCP, D -LOAD PER PLAN 206 LF 8 CONSTRUCT 30" DIA RCP, D -LOAD PER PLAN 169 LF * SEE SHEET 3 do 4 FOR DETAILS. 3939 E CORONADO ST 1400 E PHILLIPS BLVD 7951 REDWOOD AVE BEGINNING OF CURVE ANAHEIM, CA 92807 ONTARIO, CA 91766 FONTANA, CA 92335 CENTERLINE (714) 666-5500 (800) 422-4133 ATTN: JAIME AMESZCULA R I� D 1Z'AW 1 Mfrs ATTN: LARRY SIGNAIGO ATTN: STEVE HOOK (909) 357-6581 FINISHED GROUND ELEVATION FL FLOW LINE ELEVATION (909) UNDERGROUND C COMCAST (CABLE TV) FONTANA WATER COMPANY HEIGHT (ADDITIONAL OPENING) 820 -513i TRANSMISSIONS INVERT 1205 DUPONT AVE 8440 NUEVO AVE FONTANA, CA 92335 (213) 637-1233 PIPELINES oQROFESSipNq` ONTARIO, CA 91761 LT (909) 357-6589 DISTRIBUTION !`� Pg1HUR ey (909) 390-4777 x3055 (909) 822-2201 823-5046 FAX (800) 422-4133 /� �`�' a9 m A W ATTN: JACK HAYES (909) POINT OF REVERSE CURVE RCP No. 31681 RT ATTN: AL KROHN S SEWER STORM DRAIN SHT SHEET ST STREET ST 10+00 STREET STATION STD STANDARD c/V��.�! TOP OF CURB TS TRANSITION JUNCTION STRUCTURE W 7Of CALWF�� REV. REMMI DESCIWTION DME OM. CITY DATE SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT I REcoFLp DFu\W"C, 2 -OSI NUY.lfoCOMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT. ��Vnuf?'5�4� om No. 31681 Z rn * Exp. 12/31 /04 \sJ• CIVIC INZ lF CALF/ NOTES: 1. TRENCH WIDTH SHALL BE CONTROLLED TO TOP OF PIPE ZONE. 2. TRENCH DEPTHS OF GREATER THEN 5' SHALL HAVE ADEQUATE SHORING. 3. CLASS II AGG. BASE ALL TRENCHES LESS THAN 100' IN LENGTH. 3/4.1 SLOPE OR GREATER OR ADEQUATE SHORING 90% COMPACTED NATIVE BACKFILL 3" MAX SIZE N 6" MIN 8" MAX GRANULAR BEDDING FROM 1 SELECTED TRENCH SIDE MATERIAL (1" MAX SIZE) STORM DRAIN 0.6'D' I I W 3 GRANULAR BEDDING FROM SELECTED W TRENDiSIDE MATERIAL FOR TRENCH m DEPTH GREATER THAN 10'. USE 1/2 CRUSHED ROCK. TRENCH BEDDING DETAIL NTS NOTE: COMPACTION SHALL BE 90% IN ALL ZONES UNLESS OTHERWISE SPECIFIED. TRENCH STABILITY SHALL CONFORM TO CAL -OSHA REQUIREMENTS. LEGEND fI AT BC BEGINNING OF CURVE CB CATCH BASIN CL CENTERLINE DIA DIAMETER EC END OF CURVE ESMT EASEMENT EX EXISTING FG FINISHED GROUND ELEVATION FL FLOW LINE ELEVATION FS FINISHED SURFACE ELEVATION GB GRADE BREAK H HEIGHT (ADDITIONAL OPENING) INV INVERT JS JUNCTION STRUCTURE LAT LATERAL LF LINEAL FEET LT LEFT MH MANHOLE NTS NOT TO SCALE 1480.0 PAD ELEVATION POINT OF COMPOUND CURVE PRC POINT OF REVERSE CURVE RCP REINFORCED CONCRETE PIPE RT RIGHT S SEWER SD STORM DRAIN SHT SHEET ST STREET ST 10+00 STREET STATION STD STANDARD TC TOP OF CURB TS TRANSITION JUNCTION STRUCTURE W WATER C' ❑bIreman 11 TY OF FONTANA, CAL FORMA In� Inc.�' SUMMIT HEIGHTS N F, 17 A Civil Engineering • Planning • Surveying - Public Works AWN BY: STORM DRAW WROVENGM PL.AM 1152 N. Mountain Ave. Ste. 100 • Upland, CA 91786-3669.909-982-7777 MADS/RIM TME SHEET PREPARED UNDE THE UPERVISION OF: BY: / / MADS ,(`T NO. IN",/ � 4 I 10 Z CKED BY:BY: HAROLD A. GARCELON R.C.E. 31681 DATE: RLB UL AS SHOWN IE 12-03-01 NO.: 3047 /