HomeMy WebLinkAbout3044-1CITY OF FONTANA GENERAL NOTES FOR
STORK DRAIN IMPROVEMENT PLANS
1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD
PLANS, THE CONTRACT PROVISIONS, AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS
CONSTRUCTION ("GREEN BOOK") ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE
LATEST EDITION UNLESS OTHERWISE NOTED.
2. WHEN A TECHNICAL CONFUCT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN
NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN 800I( THE
CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFUCT TO THE CITY ENGINEER FOR
RESOLUTION.
3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER.
4. ADVANCE CONSTRUCTION SIGNING INDICATING DURATION OF PROJECT SHALL BE IN PLACE ONE
WEEK PRIOR TO IMPLEMENTING DETOURS.
5. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY
DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION
COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY
WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY OMITS. CALL (909) 350-7610.
6. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS, AND
PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST
NON -METRIC EDITION, UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER.
7. IT SHALL BE THE RESPOlFNS181UTY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS,
OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES.
8. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR
TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL
SAFETY.
9. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL
BE GUARDED BY SHORING, SLOPING OF THE GROUND, OR OTHER APPROVED MEANS PURSUANT TO
THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA.
TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR
GROUND MOVEMENT.
10. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT
OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE.
11. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION;
HOWEVER, IT SHALL BE THE RESPONSIBIUTY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE
TRUE LOCATION AND ELEVATION OF ANY EXISTING UTIUTIES, AND TO EXERCISE PROPER PRECAUTION
TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT
1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION.
12. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCL."G,
BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE
IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL, AND
CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK
AROUND THEIR FACILITIES.
13. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT
APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE
WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS.
14. STATIONING REFERS TO THE CENTERLINE OF STORM DRAIN EXCEPT WHERE OTHERWISE NOTED.
15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE
CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING
DURING CONSTRUCTION.
16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES, OR
BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER.
17. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS,
MONUMENT TIES, AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR
LICENSED LAND SURVEYOR. SURVEY MONIUWNTS THAT WILL BE DESTROYED AS A RESULT OF THIS
CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK
PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER
REPLACEMENT OF THE MONUMENT.
18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESITS AND BUSINESSES AT ALL
TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA
FOR RESIDENTS AND EMERGENCY VEHICLES.
19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL,
INCLUDING ADEQUATE WATERING, AT ALL TIMES.
20. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT, OR DEBRIS TO BE
DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING
CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL
21. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
22. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE
REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE
SPECIFIED DENSITY IS OBTAINED.
23. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING
STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE
TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING MNPROVEMENTS.
24. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR, AND FINISH TO MATCH
EXISTING CONCRETE.
25. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF
THE CITY ENGINEER.
26. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY
ELEVATION AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING
FACIUTIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS.
27. IF EXISTING UTILITIES OR ANY OTHER FACWTIES CONFUCT WITH THE PROPOSED IMPROVEMENTS,
THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY.
28. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN
PLACED, INSPECTED AND APPROVED.
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
CITY OF FONTANA
GENERAL NOTES (CONTOD)
29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR
TO PAVING OF STREETS.
30. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT
PRIOR TO PLACEMENT.
31. ALL MANHOLES, CLEANOUT FRAMES, COVERS, AND VALVE BOXES SHALL BE RAISED
TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING.
32. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING,
STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION
OF THE CITY TRAFFIC ENGINEER.
33. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER
OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER.
34. MINIMUM D -LOAD FOR ALL RCP IS 1350.
X1_0
15 OF ITY `'• GPS
_ZfONTANA c�-
SUMMIT AVE. SUMMIT AVE.
e
F�
i C A S
PROJECT
SITE
o:
o:
UJLAKES
c=i w PKWY
p!1m<
Jv
HIGHLAND AVE.
COUNTY OF SAN BERNARDINO
VICINITY MAP
Wm
PRIVATE ENGINEER"S NOTICE
TO CONTRACTORS
THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE
RESPONSIBIUTY FOR JOB SITE CONDITIONS DURING THE COURSE OF
CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS
AND PROPERTY, THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY
AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE
CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOU) THE AGENCY AND THE
ENGINEER HARMLESS FROM ANY AND ALL UABILTY, REAL OR ALLEGED,
IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT,
EXCEPTING FOR UABIUTY ARISING FROM THE SOLE NEGUGENCE OF THE
AGENCY OR THE ENGINEER.
�• • , MI ' '^ • y J
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR
STRUCTURES SHOWN IN THESE PLANS WERE OBTAINED BY A SEARCH OF
AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO
EXISTING U71UTIES EXCEPT THOSE SHOWN ON THESE PLANS. THE
CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO
PROTECT THE UTILITIES SHOWN, AND IS RESPONSIBLE FOR THE PROTECTION
OF, AND ANY DAMAGE TO THESE LINES OR STRUCTURES.
"CAUTION: THE ENGINEER PREPARING THESE PLANS WILL NOT BE
RESPONSIBLE FOR, OR UABLE FOR, UNAUTHORIZED CHANGES OR USES OF
THESE PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND
MUST BE APPROVED BY THE PREPARER OF THESE PLANS."
BASIS OF BEARINGS:
The basis of bearings for this drawing is the line
between the NW Cor. Sec. 25, R6W, T1N (Pt. 61) and
the Northerly quarter car. of said Sec. 25 (pt 84).Said
bearing is N 89.44'05" E as shown on RS 30/58-60.
BENCH NARK:
The Bench Mark for this project is Caltrans BM
#8-17. It is described as a Bross Cop in the
concrete base of the South leg of an SCE tower
343' North of Highland, 0.2 mi WeST of Son
Sevaine Rd., 2.65 mi WeST of Sierra Ave.
Elevation is 1428.609 feet.
CITY OF FONTANA
STORM DRAIN IMPROVEMENT PLANS
TV,
#J i 1
TRACT R10. 15843
• • • TRACT 16841
■ ,.�, AVBAE
��� ` ■■�iii■■ilii
10
_ CHELLE ST.
' I #13D vI I ■
� IZ � �U� f I ■
I I 13B
#13c
f JEANEITE DR.
I � MI # 23A TRACT
11 f
#23B f JOCELYN WY.
I I ISABEL LANE f -� (� \ I I , (- �, ■
If fI 1'- r I I f I
II I1
24 �1 ISI f l
I I l
BRIA NNE LANE) I DULCINEA
148- / #12C
z I3 N 2B •
mmmm-r OWN 3
88FIRA LAKES PAFIICWAY t 2ALi
.
&m fir------
I.
•
CITY OF FONTANA UTILITY NOTIFICATION LIST
CITY OF FONTANA
8353 SIERRA AVE
FONTANA, CA 92335
ATTN: CARLOS NAVARRO
(909) 350-6632
SOUTHERN CAUFORNIA GAS COMPANY
P.O. BOX 3003, SC8031
REDLANDS, CA 92373-0306
ATTN: RICKEY REYES
(909) 335-7508
(909) 335 7527 (FAX)
EMERGENCIES: (800) 427-2200
PACIFIC BELL COMPANY GENERAL TELEPHONE COMPANY SOUTHERN CAUFORNIA EDISON COMPANY
3939 E CORONADO ST
1400 E PHILLIPS BLVD
7951
REDWOOD AVE
ANAHEIM, CA 92807
ONTARIO, CA 91766
FONTANA, CA 92335
(714) 666-5500
(800) 422-4133
ATTN:
JAIME AMESZCULA
ATTN: LARRY SIGNAIGO
ATTN: STEVE HOOK
(909)
357-6581
12 EA
5
(909)
820-5598 UNDERGROUND
COMCAST (CABLE TV)
FONTANA WATER COMPANY
(909)
820-5137 TRANSMISSIONS
1205 DUPONT AVE
8440 NUEVO AVE
(213)
637-1233 PIPELINES
ONTARIO, CA 91761
FONTANA, CA 92335
(909)
357 - DISTRIBUTION
(909) 390-4777 x3055
(909) 822-2201
(800)
422-44133133
ATTN: JACK HAYES
(909) 823-5046 FAX
MH
MANHOLE
ATTN: AL KROHN
(1-4-80-.0-11
PAD ELEVATION
REV REVtM DESCRIPTION WE M. 01Y DATE SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT
L, RCo 2 0 35m NCS
COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL
SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER,
THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO
BRING THEM INTO CONFORMANCE WITH CONDITIONS AND
STANDARDS IN EFFECT.
/QRpFESS/p�,_\
r Z
No. 31681 Z �
* Exp. 12/31/04 *
CI VIS-
\F or CALF /
STORM DRAIN CONSTRUCTION NOTES & QUANTITIES
nu
I OMM11ON
Nm.
1
CONSTRUCT 30" DIA RCP, D -LOAD PER PROFILE.
1016 LF
2
CONSTRUCT 18" DIA RCP, D -LOAD PER PROFILE.
74 LF
3
CONSTRUCT TRANSITION STRUCTURE PER APWA STD 322-1.*
1 EA
4
CONSTRUCT CATCH BASIN PER STREET IMPROVEMENT PLAN.
12 EA
5
CONSTRUCT JUNCTION STRUCTURE -PIPE TO PIPE PER APWA STD 331-2.*
3 EA
6
CONSTRUCT MANHOLE -PIPE TO PIPE PER APWA STD 321-1.*
2 EA
7
CONSTRUCT 24" DIA. RCP, D -LOAD PER PROFILE
241 LF
* SEE SHEETS 5 & 6 FOR DETAILS.
R CE)9'0 . DV.AU I rJ G r�
Q�pFEBS/p,�
pgtHUR �Fyc
No. 31681
1W
o2�a�
L�
NOTES:
1. TRENCH WIDTH SHALL BE CONTROLLED
TO TOP OF PIPE ZONE
2. TRENCH DEPTHS OF GREATER THEN 5'
SHALL HAVE ADEQUATE SHORING.
3. CLASS II AGG. BASE ALL TRENCHES
LESS THAN 100' IN LENGTH.
3/4.1 SLOPE OR GREATER
OR ADEQUATE SHORING
90% COMPACTED NATIVE
BACKFILL 3" MAX SIZE
0
STORM DRAIN -/ 0.6'D'
GRANULAR BEDDING FROM SELECTED
TRENCHSIDE MATERIAL FOR TRENCH _
DEPTH GREATER THAN 10'. USE
1/2"CRUSHED ROCK.
NOTE: COMPACTION SHALL BE 90% IN ALL
ZONES UNLESS OTHERWISE SPECIFIED.
TRENCH STABIUTY SHALL CONFORM
TO CAL -OSHA REQUIREMENTS.
r MAX
J
W
m
0
• m
GRANULAR BEDDING FROM
SELECTED TRENCH SIDE
MATERIAL (1" MAX SIZE)
TRENCH BEDDING DETAIL
❑❑ ❑�
r�eman, Inc.
❑❑A Civil Engineering • Planning • Surveying • Public Works A
WN BY:
1152 N. Mountain Ave. Ste. 100 • Upland, CA 91786-3669.909-982-7777 MADS/RNM
PREPARED UNDER THE SUPERVISION OF: BY-
<,/07(o
Y-
</07 /O 2 MADS/GMC
( �
HAROLD A. GARCELON R.C.E. 31681 DATE: '_
CED _RLBY:B ( i
MR
LEGEND
A
AT
BC
BEGINNING OF CURVE
CB
CATCH BASIN
CL
CENTERUNE
DIA
DIAMETER
EC
END OF CURVE
ESMT
EASEMENT
EX
EXISTING
FG
FINISHED GROUND ELEVATION
FL
FLOW UNE ELEVATION
FS
FINISHED SURFACE ELEVATION
GB
GRADE BREAK
H
HEIGHT (ADDITIONAL OPENING)
INV
INVERT
JS
JUNCTION STRUCTURE
LAT
LATERAL
LF
LINEAL FEET
LT
LEFT
MH
MANHOLE
NOT TO SCALE
(1-4-80-.0-11
PAD ELEVATION
C�
POINT OF COMPOUND CURVE
PRC
POINT OF REVERSE CURVE
RCP
REINFORCED CONCRETE PIPE
RT
RIGHT
S
SEWER
SD
STORM DRAIN
SHT
SHEET
ST
STREET
10+00
STREET STATION
STD
STANDARD
TC
TOP OF CURB
TS
TRANSITION JUNCTION STRUCTURE
W
WATER
' • •
6, /1'3 /oZ
3
M
co
N
0
0
0
d
y
o�
Li
p
10
v
�
�
T
ALL-
Q
o
�
a
AS SHOWN
;'
LO
co
12-4-01
__C"
IG NO.:co
41
/N
3044
C�
8CD
..�