Loading...
HomeMy WebLinkAbout3039-1CITY OF FONTANA GENERAL NOTES 1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED. 2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK," THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION. 3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER. 4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES. 7. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. 8. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT. 9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE. 10. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION. 11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES. 12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS. 13. CURVE DATA REFERS TO THE FACE OF CURB. 14. STATIONING REFERS TO THE CENTERLINE OF STREETS EXCEPT WHERE OTHERWISE NOTED. 15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION. 16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER. 17. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT. 18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES. 20. ALL GRADING OPERATIONS SHALL BE DISCONTINUED WHEN SUSTAINED WIND VELOCITIES EXCEED 25 MILES PER HOUR. 21. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL 22. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 23. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED. 24. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS. A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT CITY OF FONTANA GENERAL NOTES (CONT'D) 25. THE FINAL LOCATION AND WIDTH OF DRIVEWAY APPROACH APRONS SHALL BE APPROVED AT THE TIME OF CONSTRUCTION AND SHALL CONFORM TO THE CITY OF FONTANA STANDARD DETAILS. 26. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE. 27. THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE CURB AT THE LOCATION OF THE SEWER LATERAL 28. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. 29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS. 30. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT. 31. PAVEMENT STRUCTURAL SECTIONS SHOWN ARE MINIMUM AND SUBJECT TO REVISION AND APPROVAL OF THE CITY ENGINEER AS DETERMINED BY SOILS TESTS TAKEN AFTER COMPLETION OF ROUGH GRADING. 32. ACTUAL THICKNESS OF A.C. PAVEMENT AND/OR BASE COURSE MATERIAL FOR STRUCTURAL STREET SECTIONS SHALL BE RECOMMENDED BY A GEOTECHNICAL REPORT AND SUBMITTED TO THE CITY OF FONTANA FOR APPROVAL UPON COMPLETION OF ROUGH GRADING. 33. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING. 34. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER. 35. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS AND SIDEWALKS AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE CITY ENGINEER. 36. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER. PRIVATE ENGINEER'S NOTICE TO CONTRACTORS THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY. THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE AGENCY AND THE ENGINEER HARMLESS FROM ANY AND ALL UABILTY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE AGENCY OR THE ENGINEER. UNDERGROUND UTILITIES & STRUCTURES THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN IN THESE PLANS WERE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN, AND IS RESPONSIBLE FOR THE PROTECTION OF, AND ANY DAMAGE TO THESE LINES OR STRUCTURES. CAUTION: THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR, OR LIABLE FOR, UNAUTHORIZED CHANGES OR USES OF THESE PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND MUST BE APPROVED BY THE PREPARER OF THESE PLANS." BASIS OF BEARINGS: THE BASIS OF BEARINGS FOR THIS DRAWING IS THE LINE BETWEEN THE NW COR. SEC. 25, RM, T1N (PT. 61) AND THE NORTHERLY QUARTER COR. OF SAID SEC. 25 (PT 84). SAID BEARING IS N89'44'05"E AS SHOWN ON RS 30/58-60. BENCH MARK: THE BENCH MARK FOR THIS PROJECT IS CALTRANS BM #8-17. IT IS DESCRIBED AS A BRASS CAP IN THE CONCRETE BASE OF THE SOUTH LEG OF AN SCE TOWER 343' NORTH OF HIGHLAND, 0.2 MI WEST OF SAN SEVAINE RD., 2.65 MI WEST OF SIERRA AVE. ELEVATION IS 1428.609 FEET. BACK OF WALK ---) di_sj U W . 0 iG N F.H., ST. LIGHT SIGN, MISC. CURB FACE­­- GUTTER ACEGUTTER UP SDEWALK JOG DETAL SCALE: 1'=6' REV REVISION DESCRIPTION r2,m RD .D RAW 113 6- R/W 1 7' F�- 6 5' ` PUEI I I L_ CITU OF FONTANA STREET IMPROVEMENT PLASS mea. TRACT N0. 15841 CITY OF FONTANA 8353 SIERRA AVE FONTANA, CA 92335 ATTN: CARLOS NAVARRO (909) 350-6632 SOUTHERN CALIFORNIA GAS COMPANY P.O. BOX 3003, SC8031 REDLANDS, CA 92373-0306 ATTN: RICKEY REYES (909) 335-7508 (909) 335 7527 (FAX) EMERGENCIES: (800) 427-2200 50' / 54' CL 18' / 20' CITY OF FONTANA UTILITY NOTIFICATION LIST PACIFIC BELL COMPANY GENERAL TELEPHONE COMPANY SOUTHERN CALIFORNIA EDISON COMPANY 3939 E CORONADO ST 1400 E PHILLIPS BLVD 7951 REDWOOD AVE ANAHEIM, CA 92807 ONTARIO, CA 91766 FONTANA, CA 92335 (714) 666-5500 (800) 422-4133 ATTN: JAIME AMESZCULA ATTN: LARRY SIGNAIGO ATTN: STEVE HOOK (909) 357-6581 5 CONST 4" THICK PCC SIDEWALK PER CITY STD PLAN No 1015 (909) 820-5598 UNDERGROUND COMCAST (CABLE TV FONTANA WATER COMPANY (909) 820-5137 TRANSMISSIONS 1205 DUPONT AVE 8440 NUEVO AVE (213) 637-1233 PIPELINES ONTARIO, CA 91761 FONTANA, CA 92335 (909) 357 - DISTRIBUTION (909) 390-4777 x3055 (909) 822-2201 (800) 422-44133133 ATTN: JACK HAYES (909) 823-5046 FAX 5 EA W ATTN: AL KROHN EL'Y R/W 18' / 20' 7' O 18' CL +0.03' = TC (5(f R/W) 6` I 5. O 20' CL -001' = TC (54' R/W) 5` % I I PUE I PUE 2.0% I 2.0% 2.0 I I _J L- 6" CONC CURB 6" CONC CONC & GUTTER OO CURB & GUTTER CONC SIDEWALKOS O SID so Rw ' 6NfZD TD)RAW/JCff ANDREW�S LANE, ARLINGTON WAY OU SS/ WAY ; oQssioNq` reg. QgSHUR Ey (STA 11+99.59 to 16+50.87_) � oo m 54' RW 0 No. 31681cc � ROOSEVELNE T DRIVE & ARICAN WAY .k2 (STA 10+00.00 to 11+99.59) sr i V NTS OF CAI. TI = 5.5 316 2. 64 TDATEENG:7R CITY DATE SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT no s•y COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT. i- 0-% CL 22' 22' CL -0.05' = TC 3 2.0% k�_6" CONC CURB 6" CONC CONC &GUTTER O OO CURB & GUTTER SIDEWALK 05 CONC 72' RW OQ SIDEWALK VANESSA WAY NTS TI = 6.5 /,mOFESS/0��\ �THUR C� r rZn W No. 31681 -- z * Exp. 12/31/04 ��qTFOFF' 1VI�\���\Q CAS / STREET CONSTRUCTION NOTES & QUANTITIES nai 1 DMMPTION CITY. 1 CONST 4" MIN AC OVER 12" OF 95% COMPACTED NATIVE (SEE GENERAL NOTES 31 & 32) 67,598 SF 2 CONST 6" CURB AND GUTTER PER CITY STD PLAN No 1003 3,640 LF 3 CONST 4.5" MIN AC OVER 12" OF 95% COMPACTED NATIVE (SEE GENERAL NOTES 31 & 32) 3,025 SF 4 CONST RESIDENTIAL DRIVEWAY APPROACH (16' MAX) PER CITY STD No 102 52 EA 5 CONST 4" THICK PCC SIDEWALK PER CITY STD PLAN No 1015 20,272 SF 6 CONST CURB RETURN ACCESS RAMP PER CITY STD PLAN No 1006 4 EA 7 INSTALL STREET LIGHT 5800 LUMEN PER CITY STD No 1016 (SCE#7) 7 EA 8 CONST INLET LOCAL DEPRESSION PER CITY STD PLAN No 121 (W=PER PLAN) 5 EA 9 REMOVE EXISTING BARRICADE 1 EA 11 CONST CURB OPENING CATCH BASIN PER APWA STD PLAN No 300-2 (W=PER PLAN) * 5 EA W * SEE SHEET 4 EL'Y / P 5 0cro. : �•GP 15 G ONTANA rte• SUMMIT AVE. SUMMIT VE. P w FQ` PROJECT SITE a CURTIS JCn AVE. wU 1� = w U ma HIGHLAND AVE. COUNTY OF SAN BERNARDINO VICINITY MAP NTS R/W i LEGEND INDEX OF SHEETS SHEET DESCRIPTION 1 OF 4 11TLE SHEET 2 OF 4VANESSA WAY, ROOSEVELT DRIVE, & ANDREWS LANE 3 OF 4 AMERICAN WAY 4 OF 4 ARLINGTON WAY R/W i LEGEND 5, 0o BC BEGIN CURVE PCC POINT OF COMPOUND CURVE rPU BVC BEGIN VERTICAL CURVE PRC POINT OF REVERSE CURVE I BCR BEGIN CURVE RADIUS R/W RIGHT OF WAY J CB CATCH BASIN SL STREET LIGHT - CL CENTERLINE STA STATION EC END CURVE TC TOP OF CURB ECR END CURVE RADIUS W WIDTH EL'Y EASTERLY WILY WESTERLY EP EDGE OF PAVEMENT V VERTICAL DEPTH EVC END VERTICAL CURVE (450,00) INDICATES EXISTING ELEVATION FL FLOW UNE 450.00 INDICATES PROPOSED ELEVATION FS FINISHED SURFACE W WATER LINE GB GRADE BREAK S SEWER LINE HP HIGH POINT SD STORM DRAIN LINE INT INTERSECTION LL LOT UNE LP LOW POINT OC ON CURB MVC MIDDLE OF VERTICAL CURVE H HEIGHT (ADDITIONAL OPENING) EIDEIV H &.1.1nan, Inc. 1:10 V A Civil Engineering - Planning • Surveying • Public Works 1152 N. Mountain Ave. Ste. 100 " Upland, CA 91786-3669.909-982-7777 PREPARED UNDER THE SUPERVISION OF: 4 < <4rbz HAROLD A. GARCELON R.C.E. 31681 DATE: CITY OF FONTANA, CALIFORNIA SUMMIT HEIGHTS 11 MN BY: STREET L13ROVENEM PLANS MSM IGNED BY- ME MEET MSM IRACT NO.15841 CKED BY: BY: / RLB4 ���i�LS'l0 L CITY FN(.INFFR R r F r,11 RGI neTr. 0o Lz L U N Y o� NONE N co M TE: 11-12-01 O,o G NO.: co 3039 �� 0 4