HomeMy WebLinkAbout3038-10
CITY OF FONTANA GENERAL NOTES FOR
STORM DRAIN IMPROVEMENT PLANS
1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD
PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS
CONSTRUCTION ("GREEN BOOK") ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE
LATEST EDITION UNLESS OTHERWISE NOTED.
2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN
NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK THE
CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR
RESOLUTION.
3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER.
4. ADVANCE CONSTRUCTION SIGNING INDICATING DURATION OF PROJECT SHALL BE IN PLACE ONE
WEEK PRIOR TO IMPLEMENTING DETOURS.
5. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY
DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK.
INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE
START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610.
6. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND
PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST
NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER.
7. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DEUNEATORS
OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES.
8. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR
TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL
SAFETY.
9. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL
BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO
THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA.
TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR
GROUND MOVEMENT.
10. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT
OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE.
11. THE LOCATIONS OF U11UTIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION,
HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE
TRUE LOCATION AND ELEVATION OF ANY EXISTING UTIUTIES, AND TO EXERCISE PROPER PRECAUTION
TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT
1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION.
12. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING,
BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE
IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND
CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK
AROUND THEIR FACILITIES.
13. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT
APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE
WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS.
14. STATIONING REFERS TO THE CENTERLINE OF STORM DRAIN EXCEPT WHERE OTHERWISE NOTED.
15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE
CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING
DURING CONSTRUCTION.
16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR
BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER.
17. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS,
MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR
LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS
CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK
PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER
REPLACEMENT OF THE MONUMENT.
18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL
TIMES, A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA
FOR RESIDENTS AND EMERGENCY VEHICLES.
19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL,
INCLUDING ADEQUATE WATERING, AT ALL TIMES.
20. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE
DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING
CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL
21. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
22. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE
REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE
SPECIFIED DENSITY IS OBTAINED.
23. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING
STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE
TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS.
24. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH
EXISTING CONCRETE.
25. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF
THE CITY ENGINEER.
26. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY
ELEVATION AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING
FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS.
27. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS,
THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY.
28. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN
PLACED, INSPECTED AND APPROVED.
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
CITY OF FONTANA
GENERAL NOTES (CONT9D)
29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING
OF STREETS.
30. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO
PLACEMENT.
31. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED
GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING.
32. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING,
BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC
ENGINEER.
33. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD,
WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER.
34. MINIMUM D -LOAD FOR ALL RCP IS 1350.
/ Gam. GPS
OF
FONTANA c�•
SUMMIT AVE. SUMMIT VE.
AFF PROJECT
QVC 9� �ti SITE
O
Y
Q IERRA w
PKWY Of
V W>
�m a
1
HIGHLAND AVE.
COUNTY OF SAN BERNARDINO
VICINITY MAP
NTS
PRIVATE ENGINEER'S NOTICE
TO CONTRACTORS
THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE
RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF
CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS
AND PROPERTY. THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY
AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE
CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE AGENCY AND THE
ENGINEER HARMLESS FROM ANY AND ALL UABILTY, REAL OR ALLEGED,
IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT,
EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGUGENCE OF THE
AGENCY OR THE ENGINEER.
LWWD� list
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR
STRUCTURES SHOWN IN THESE PLANS WERE OBTAINED BY A SEARCH OF
AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO
EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE
CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO
PROTECT THE UTILITIES SHOWN, AND IS RESPONSIBLE FOR THE PROTECTION
OF, AND ANY DAMAGE TO THESE LINES OR STRUCTURES.
"CAUTION: THE ENGINEER PREPARING THESE PLANS WILL NOT BE
RESPONSIBLE FOR, OR LIABLE FOR, UNAUTHORIZED CHANGES OR USES OF
THESE PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND
MUST BE APPROVED BY THE PREPARER OF THESE PLANS."
BASIS OF BEARINGS:
The basis of bearings for this drawing is the line
between the NW Cor. Sec. 25, R6W, T1 N (Pt. 61) and
the Northerly quarter cor. of said Sec. 25 (pt 84).Said
bearing is N 89'44'05" E as shown on RS 30/58-60.
BENCH MARK:
The Bench Mark for this project is Caltrans BM
#8-17. It is described as a Brass Cap in the
concrete base of the South leg of an SCE tower
343' North of Highland, 0.2 mi WeST of San
Sevaine Rd., 2.65 mi WeST of Sierra Ave.
Elevation is 1428.609 feet.
CITY OF FONTANA
STORM DRAIN IMPROVEMENT
FOR
TRACT NO. 15841-1
CITY OF FONTANA UTILITY NOTIFICATION LIST
CITY OF FONTANA
8353 SIERRA AVE
FONTANA, CA 92335
ATTN: CARLOS NAVARRO
(909) 350-6632
SOUTHERN CAUFORNIA GAS COMPANY
P.O. BOX 3003, SC8031
REDLANDS, CA 92373-0306
ATTN: RICKEY REYES
(909) 335-7508
(909) 335 7527 (FAX)
EMERGENCIES: (800) 427-2200
PACIFIC BELL COMPANY GENERAL TELEPHONE COMPANY SOUTHERN CAUFORNIA EDISON COMPANY
3939 E CORONADO ST
1400 E PHILLIPS BLVD
7951
REDWOOD AVE
ANAHEIM, CA 92807
ONTARIO, CA 91766
FONTANA, CA 92335
(714) 666-5500
(800) 422-4133
ATTN:
JAIME AMESZCULA
ATTN: LARRY SIGNAIGO
ATTN: STEVE HOOK
(909)
357-6581
5
CONSTRUCT MANHOLE -PIPE TO PIPE PER APWA STD 320-1. SEE DETAIL ON SHT 3.
909)
820-5598 UNDERGROUND
COMCAST (CABLE TV)
FONTANA WATER COMPANY
(909)
820-5137 TRANSMISSIONS
1205 DUPONT AVE
8440 NUEVO AVE
(213)
637-1233 PIPEUNES
ONTARIO, CA 91761
FONTANA, CA 92335
(909)
357-6589 DISTRIBUTION
(909) 390-4777 x3055
(909) 822-2201
(800)
422-4133
ATTN: JACK HAYES
(909) 823-5046 FAX
MH
MANHOLE
NTS
ATTN: AL KROHN
1480.0
PAD ELEVATION
REV REVISION DESCMP1M DATE ENGR. I CITY DATE SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT
REC.o2D DRAW I0Ca 2- Oy HG'7Q dV4
COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL
SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER,
THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO
BRING THEM INTO CONFORMANCE WITH CONDITIONS AND
STANDARDS IN EFFECT.
/QROFESS/O�\
Z
= No. 31681 Z �
* Exp. 12/31/04
tCIVI
eAOF- CA��F�/
STORM DRAIN CONSTRUCTION NOTES & QUANTITIES
nEw
I DESCRIPTION
AT
1
CONSTRUCT 36" DIA RCP, D -LOAD PER PROFILE
4
2
CONSTRUCT 18" DIA RCP, D -LOAD PER PROFILE
3
CONSTRUCT CATCH BASIN PER STREET IMPROVEMENT PLAN.
4
CONSTRUCT JUNCTION STRUCTURE -PIPE TO PIPE PER APWA STD 331-2. SEE DETAIL ON SHT 3.
1317L�F
5
CONSTRUCT MANHOLE -PIPE TO PIPE PER APWA STD 320-1. SEE DETAIL ON SHT 3.
6
CONSTRUCT CONCRETE COLLAR FOR PIPE PER APWA STD #380-2. SEE DETAIL ON SHT 3.
7
CONSTRUCT 24" DIA RCP, D -LOAD PER PROFILE
NOTES:
1. TRENCH WIDTH SHALL BE CONTROLLED
TO TOP OF PIPE ZONE.
2. TRENCH DEPTHS OF GREATER THEN 5'
SHALL HAVE ADEQUATE SHORING.
3. CLASS II AGG. BASE ALL TRENCHES
LESS THAN 100' IN LENGTH.
STORM DRAIN
3/4:1 SLOPE OR GREATER
OR ADEQUATE SHORING
90% COMPACTED NATIVE
BACKFILL 3" MAX SIZE
I.1
•O
GRANULAR BEDDING FROM SELECTED
TRENCHSIDE MATERIAL FOR TRENCH
DEPTH GREATER THAN 10'. USE
1/2 CRUSHED ROCK.
6" MIN
8" MAX
z
VW
GRANULAR BEDDING FROM
SELECTED TRENCH SIDE
MATERIAL (1" MAX SIZE)
TRENCH BEDDING DETAIL
NTS
NOTE: COMPACTION SHALL BE 90% IN ALL
ZONES UNLESS OTHERWISE SPECIFIED.
TRENCH STABILITY SHALL CONFORM
TO CAL -OSHA REQUIREMENTS.
LEGEND
0
AT
BC
BEGINNING OF CURVE
CB
CATCH BASIN
CL
CENTERUNE
DIA
DIAMETER
EC
END OF CURVE
ESMT
EASEMENT
EX
EXISTING
FG
FINISHED GROUND ELEVATION
FL
FLOW LINE ELEVATION
FS
FINISHED SURFACE ELEVATION
GB
GRADE BREAK
H
HEIGHT (ADDITIONAL OPENING)
INV
INVERT
JS
JUNCTION STRUCTURE
LAT
LATERAL
LF
LINEAL FEET
LT
LEFT
MH
MANHOLE
NTS
NOT TO SCALE
1480.0
PAD ELEVATION
POINT OF COMPOUND CURVE
PRC
POINT OF REVERSE CURVE
RCP
REINFORCED CONCRETE PIPE
RT
RIGHT
S
SEWER
"R C -C D IIID D K P(W I N G SD STORM DRAIN
/ o4m SHT SHEET
`'�V/ ST STREET
ST 0+00 STREET STATION
oQ?,pFESS/p STD STANDARD
Q`� PRTHURE` TC TOP OF CURB
y y� f� TS TRANSITION JUNCTION STRUCTURE
W WATER
� No 3,1681
Exp. �
1:1111117
H1 & Fbireman,Inc.
❑❑ 1 A Civil Engineering - Planning - Surveying - Public Works DRAWN BY:
1152 N. Mountain Ave. Ste. 100 - Upland, CA 91786-3669.909-982-7777 MADS/MFP
PREPARED UNDER THE SUPERVISION OF: DERGNED BY:
MADS
4�91 (v //3 / a 2 CHECKED BY:
HAROLD A. GARCELON R.C.E. 31681 DATE: ? RLB
CITY OF FONTANA, CALPORNA
SUMMIT HEIGHTS N
3TORAA DRAM MnOVEIABJT PLANS
11TLE SHEET
TRAET N0. 16841
BY.
e/1f.?10?---'
1"=40'
TE
CN
12-07-01
G NO.:CO-
1
3038 3 N
0