HomeMy WebLinkAbout3029-37I PLAN NOTES O 20, GFI, DUPLEX OUTLET AT + 42" (ABOVE COUNTER) FLUSH IN CONCRETE BLOCK WALL WITH STAINLESS STEEL FACE PLATE. �2 ALL PLATES IN CONCESSION TO BE STAINLESS STEEL. O3 CIRCUITED THROUGH MUSCO "CONTROL LINKS". O SEE PLAN NOTES 22 AND 23 ON E-1. O5 480V, 30, 60A/3P NON—FUSED DISCONNECT, WALL MOUNTED "BUILDING DISCONNECT". O 480 — 120/208V, 30, 4W, DRY TYPE TRANSFORMER, BOLT TO FLOOR. (25KVA) HOOK—UP TO 5KW, 208V, 10 EWH. VERIFY EXACT ELECT. REQUIREMENTS. PROVIDE NON— FUSE DISCONNECT ON WALL. G8 36" X 36" X 3/4" PLYWOOD BACKBOARD FOR TEL. WITH 1 #6 GROUND. O EXPOSED CONDUIT ALLOWED IN SNACK BAR STORAGE, PARK STORAGE AND PIPE CHASE ROOMS. ALL OTHER CONDUITS CONCEALED IN BLOCK WALLS (SNACK BAR AND RESTROOMS). 10 HOOK—UP TO HAND DRYER. 11 TELEPHONE OUTLET AT + 48" WITH 3/4" C.O. TO TEL. BK. BD. 12 STUB OUT/CAP 24" PAST WALK WAY INTO SOCCER FIELD SIDE TURF, TWO 1" C.O. FROM 'LA' (LB) AND 1" C.O. FROM TEL BK. BD. VERIFY STUB OUT LOCATION. 8}y HA 4 ALL OL + 42" (1 COON r% J r% J ' TO CENTER ICAL) IN EACH BUILDING 2.0 SQ. FT. HOOK—UP TO FIRE SPRINKLER RISER AND ALARM TO LA (LB) 26 WITH 1/2" C. 2 #12, VERIFY LOCATION. ALSO PROVIDE 3/4" C.O. FROM TEL. BACKBOARD TO FIRE SPRINKLER PANEL ALL CIRCUITING SAME FOR EACH BUILDING EXCEPT LA, 7-9-11 . 4-5 Electrical Floor Plan—Building No.1 Panel LA) And Building No.2 (Panel LB ) 2C 1/4" = 1,-0" h LITHONIA NO. KSF2-250S—R3—LEX— TB(277V)— DDB (BRONZE) (250W HPS, MULTI—TAP BALLAST) EPA = 2.0 SQ. FT. LENGTH = 25 5/16 WIDTH = 18 1/2 - /2"DEPTH DEPTH = 8 5/16" WEIGHT = 55 LBS ALUMINUM POLE CIRCUIT CODE: blank or N : NON—CONTINUOUS L : LONG—CONTINUOUS MOUNTING: SURFACE R : DEMANDABLE RECEPTACLES K : KITCHEN NO. OF EQUIPMENT: 4" SQ X .188" THICK DESCRIPTION BOLT CIRC: 8 1/2" TO 9 5/8" BOLT SIZE: 3/4" X 30" X 3" WEIGHT: 85 LBS mp.) FINISH AND COLOR TO O MATCH FIXTURE :ff]GFI - TAMPER RESISTANT (2X) HANDHOLE COVER ® - BOLT COVER Q .288 THICK CAST ALUMINUM WITH BOLT DOWN LID WEATHER PROOF FINISH TO MATCH POLE DENOTES DETAIL 'A', SHEET 'E-1' —CONCRETE FOUNDATION (TYPE V) 2500 PSI ® 28 DAYS ELECTRICAL CONTRACTOR WITH SLOPED TOP FOR DRAINAGE a "SAND BLAST" FINISH t .t i FINISHED GRADE tt. — i t — — — — 60" > r CONDUIT(S) 24" BELOW GRADE. t. ALL RISERS AND 90' BENDS L—= r� SHALL BE PVC COATED RGS. . t• t ANCHOR BOLTS 3" BY MANUFACTURER 24" BOLT SIZE: 3/4" X 30" X 3" DIA 8 MIN. #4 VERTICAL (ASTMG15,40) 6 MIN. #4 VERT. BARS WITH 3—#3 TIES WTIHIN TOP FIVE INCHES, ONE #3 TIE 3" #3 TIES MIN. ® 12" O.C., ` +_' FROM BOTTOM WITH REMAINDER � �,�� 18 DIA. WITH 12" LAP. #3 TIES MAX. 12„ O.C. �r 3” CLR TO TIES Licht Standard 'XA' N.T.S. • ELECTRICAL SYMB0LS LIST CIRCUIT CODE: blank or N : NON—CONTINUOUS L : LONG—CONTINUOUS MOUNTING: SURFACE R : DEMANDABLE RECEPTACLES K : KITCHEN NO. OF EQUIPMENT: SYMBOL DESCRIPTION SYMBOL DESCRIPTION ... NEW BALLFIED LIGHTING POLE WITH BACKLIGHT (♦ = BACKLIGHT) mp.) 120V, DUPLEX 20A RECEPTACLE AT +16' MINIMUM (OR AS NOTED) O INDICATES PLAN NOTE NUMBER '1', SEE PLAN :ff]GFI 120V, GFI DUPLEX 20A RECEPTACLE (2X) SEE VAULT. BOX DETAIL ® PULL BOX FLUSH IN GRADE. BROOKS #PB1 ORAS NOTED ON PLANS Q JUNCTION BOX W.P. WEATHER PROOF A E-1 DENOTES DETAIL 'A', SHEET 'E-1' PROVIDE FURNISH/INSTALL/CONNECT E.C. ELECTRICAL CONTRACTOR A-1,- HOMERUN TO PANEL 'A', CIRCUITS J1 AND /3 GFl GROUND FAULT INTERRUPT RECEPTACLE — HASH MARKS INDICATE THREE 112 WIRES IN CONDUIT, EXCEPT NO HASH MARKS DESIGNATE 2 #12 WIRES. 1 Ift MINIMUM OR AS NOTED N.I.C. NOT IN CONTRACT ,off,- HASH MARKS INDICATE FOUR 112 WIRES IN CONDUIT. 1/2'C. MINIMUM OR AS NOTED C.O. CONDUIT ONLY (WITH STEEL PIAL WIRE) low_ HASH MARKS INDICATE FIVE 112 WIRES IN CONDUIT. 3/4'C. MINIMUM OR AS NOTED EX EXISTING lff w HASH MARKS INDICATE SIX 112 WIRES IN CONDUIT. 3/4'C. MINIMUM OR AS NOTED G GROUND ------ CONDUIT/WIRE UNDER SLAB OR BELOW GRADE, 3/4' MINIMUM S LIGHT SWITCH AT 48' 23 20 1 SPARE CONDUIT/WIRE CONCEAI.ED ABOVE CQUNG OR IN WALLS 24 1261 25 20 1 SPARE --EX-- MOW CONDUIT/WIRE UNDER SLAB OR BELOW GRADE 27 20 1 SPARE ISPACE 28 CONDUIT STUB OUT, 3/4' MINIMUM - SEE PUNS FOR NOTES BUILDING NO.1 PANEL: LA PANEL VOLTAGE: 208/120 3 4) 4 W BUS: 125A DATE: 09/10/01 TIME: 15:26:47 MAINS: 125/3P JOB: 1785 AIC RATING: 10,000 CIRCUIT CODE: blank or N : NON—CONTINUOUS L : LONG—CONTINUOUS MOUNTING: SURFACE R : DEMANDABLE RECEPTACLES K : KITCHEN NO. OF EQUIPMENT: 0 $ o a w LOAD DESIGNATION 8 DESCRIPTION (NOTE) M R L C O N N 0A OB OC E C T A B C E D V A OA -0B SCC L R LOAD DESIGNATION M (NOTE) DESCRIPTION a w o$ a v 0 1 L 20 1 INTERIOR - RR 6 800 1100 500 1500 2500 2500 13 INTERIOR 20 1 2 3 20111 EXTERIOR 11 EWH 30 4 5 20 1 OUTLET ON POLES 2 EM 2 1 HAND DRYER 20 1 6 8 7 20 1 MUSCO CONTROL 1 1000 1000 180 1500 1500 180 9 20 1 MUSCO CONTROL 1 1 HAND DRYER 20 1 10 11 20 1 IRRIG. CONTROL 1 1 A TEL. 20 1 12 13 20 1 ICE 1 1200 1200 1200 1200 1200 1200 1 SNACK BAR 20 1 14 15 20 1 SODA 1 1 SNACK BAR 20 1 16 17 20111 SNACK BAR 1 1 SNACK BAR 20 1 18 19 20 11 REFG. 1 1200 500 1200 112001 1200 1 SNACK BAR 20 1 20 21 20 1 REFG. 1 1 1 1 ISNACK BAR 20 1 22 23 20 1 SPARE 1 1 ISNACK BAR 20 1 A FIRE SPRINKLER 20 1 24 1261 25 20 1 SPARE 21 20111 REFG. 1 200 27 20 1 SPARE ISPACE 28 29 2011 SPARE ISPACE I SPACE 30 32 31 2011 SPARE 27 20 1 SPARE SPACE 33 1 ISPACE ISPACE 34 35 ISPACE SPACE SPACE 1 36 38 37 SPACE L SPACE 39 SPACE SPACE 1 40 41 SPACE SPACE 1 42 PANEL NOTES: PHASE TOTALS 0A: 9600 4�B: 10200 1 0C: 6960 ®(@CIRCUITS CONTROLLED BY MUSCO 'CONTROL -LINKS' SYSTEM PROVIDE 2OA/1 P ELEC. HELD RELAY. MOUNT IN RELAY CABINET ABOVE PANEL QA PROVIDE LOCK -ON DEVICE ON C.B. PANEL TO HAVE LOCKABLE DOOR TOTAL CONNECTED VA CONNECTED VA (CODE N) CONNECTED VA (CODE L) CONNECTED VA (CODE R) CONNECTED VA (CODE K) PANEL CONNECTED KVA PANEL DEMAND KVA PANEL DEMAND AMPS HIGH 0 AMPS W/LCL 26760 39 SPACE SPACE 24860 41 SPACE 1900 42 0 0 24880 26.8 27.2 75.6 87.3 IUILDING N0.2 PANEL: LB PANEL VOLTAGE: 208/120 310 4 W AGE: 125/ DATE: 09/10/01 TIME: 15:29:09 MAINS: 125/3P JOB: 1785 AIC RATING: 10,000 CIRCUIT CODE: blank or L : LONG -CONTINUOUS NUOUS MOUNTING: SURFACE R : DEMANDABLE RECEPTACLES K : KITCHEN NO. OF EQUIPMENT: 0 $ w a LOAD DESIGNATION C O N N E CT E D V A 100 LOAD DESIGNATION a ww $ tis U F R DESCRIPTION (NOTE) M R L 4�A 10B 40C ABC 4A -OB -OC L R M (NOTE) DESCRIPTION IY a 8 M 1 L 20 1 INTERIOR - RR 6 800 -1-100-1 1 800 1500 25001 12500 13 1 INTERIOR 20 1 2 3 L 20 1 EXTERIOR 11 1 EWH .307 4 5 20 1 1 OUTLET ON POLES 2 1 1 EWH 2 1 1 IHAND DRYER 20 1 6 8 7 20 1 SPARE 1 X X X 1500 11500 180 9 20 1 SPARE 1 1 IHAND DRYER 20 1 10 11 20 11 SPARE 1 1 TEL 20 11 1 SNACK BAR 20 1 12 14 13 20 11 ICE 1 1200 1200 1200 1200 1200 1200 15 20111 SODA 1 1 SNACK BAR 20 1 16 17 20 1 SNACK BAR 1 1 SNACK BAR 20 1 1 SNACK BAR 20 1 18 20 19 20111 REFG. 1 1200 500 X 1200 1200 1200 21 20111 REFG. 1 1 SNACK BAR 20 1 22 23 20 1 SPARE 1 SNACK BAR 20 1 A FIRE SPRINKLER 24 26 25 20 1 SPARE X X X 200 27 20 1 SPARE SPACE 28 29 20 1 SPARE SPACE SPACE 30 32 31 20 1 SPARE X I 33 1 ISPACE SPACE 34 35 1 ISPACE SPACE 36 37 SPACEE _ SPACE 38 39 SPACE SPACE 40 41 SPACE SPACE 42 PANEL NOTES: PHASE TOTALS 40A: 8600 4)8: 9200 OC: 7080 ®®CIRCUITS CONTROLLED BY MUSCO 'CONTROL -LINKS' SYSTEM PROVIDE 20A/1 P ELEC. HELD RELAY. MOUNT IN RELAY CABINET ABOVE PANEL I PROVIDE LOCK -ON DEVICE ON C.B. TOTAL CONNECTED VA CONNECTED VA (CODE N) CONNECTED VA (CODE L) CONNECTED VA (CODE R) CONNECTED VA (CODE K) PANEL CONNECTED KVA PANEL DEMAND KVA PANEL DEMAND AMPS HIGH AMPS W/LCL 24880 22980 1900 0 0 24.9 25.4 70.4 79.0 BUILDING FIXTURE SCHEDULE CHK TYPE TOTAL WATTS LAMP CAT. NO. + MOUNTING VOLTAGE A 100 70W KENALL NO. MR17EL—P—MB-70S 120 000 0 HPS + 8'-6" TO CENTER 0 B 130 10OW KENALL NO. MR17FD—P—MB-100M 120 a M M.H. + 12 Ff. TO CENTER VERIFY HEIGHT o C 65 2435 KENALL NO. SH648-2-32—EB 120 T-8 SURFACE CA 65 2435 SAME AS TYPE 'C' EXCEPT 120 V T-8 CHAIN HANG TO + 7'-6" 65 2435 KENALL NO. SH648-2-32—EB 120 Z T-8 CHAIN HANG TO + 7'-6" PS E. Hg9��Fy INCLUDE TOTAL 4 KENALL NO. 9500 SCREWDRIVERS �9 z No. 7531 m, EXP: 9130103 4 �• 'F Cav 01-14-02 00 REEDCORP ENGNEERINfi CONSULTING ELECTRICAL ENGINEERS I 2061 Business Center Drive, Suite 110 � Irvine, CA 92612 1 (949) 752-1276 FAX: (949) 752-1287 o E—MAIL : ee®reedcorp.net nwwn By. 1 S I T le 1 C A P e 1 Landscape Architecture and Planning 19762 Mac Arthur Blvd., Sts.130 Irvine, CA 92612 Richard Polhamus, Uoons. CA -#2782 (949) 644-9370 (949) 476-1432 FAX rtA F REVISION-�4wrlC 103 A AA In ■ ■ DYM CHK DATE 01-14-02 CC3 .■ 3 of 39 1— w 4� 000 0 0 0 z a M IQ o . to C) .,—, 00 V 0 H � Z DYM CHK DATE 01-14-02 CC3 .■ 3 of 39 1— w 4� Z, 0 0 0 z a IQ DYM CHK DATE 01-14-02 JOB # 01-017 .■ 3 of 39