IRRIGATION DESIGN CRITERIA
Name of Water Supplier: Fontana Water District
Pressure Given By: MIKE MC GAW (909) 822-2201
Pressure Given By: STEVE GAO (626) 448-6183
THE FONTANA WATER DISTRICT WAS UNABLE TO GIVE A PRECISE
PRESSURE READING AT THE SITE. THE CITY PREFORMED A
PRESSURE TEST FROM A HYDRANT ON CITRUS AVE. ACCROSS FROM
THE PROJECT.
PLANT ELEV. +1639
AVAILABLE PRESSURE 66 PSI
RESIDUAL 44 PSI
AVAILABLE FLOW: 2016 GPM
PRESSURE: CITRUS @ CUTRIS 55 PSI
PER CITY FH READING ACCROSS THE STREET
Contractor shall verify the static water pressure with supplier prior to installation.
If different from PSI noted above, Contractor to notify Owner for instructions.
Failure to do so will result in contractor being responsible for changes that might
occur.
POINT OF CONNECTION:
(5) 2" Water meters to manifold into (1) p.o.c. , Refer to civil plans.
System requires the contractor to provide a Bear State Pump,
( SEE THIS SHEET FOR BOOSTER PUMP NOTE)
Contractor to install a (3) 2" Febco 825Y reduced pressure type
back flow preventer and locate in individual Strong Box vandal resistant,
stainless steel enclosures. Verify enclosure size prior to purchase.
Coordinate locations with City Inspector.
STATIC PRESSURE @ METERS: 55 PSI
(FROM FH READING)
ADDITIONAL PUMP PRESSURE 65 PSI
AVAILABLE SYSTEM PRESSURE 120 PSI
DESIGN PRESSURE: 117 PSI
SYSTEM MAXIMUM DEMAND ALLOWED: 384 GPM
SYSTEM WORST DEMAND CONDITION:
Al 61 C1 D1 E1 F1
63 56 56 56 56 56 = 343 GPM
CONTROLLER NOTE: A , B. C. D. E & F
Contractor to coordinate the installation of the controller and their locations
with the City Inspector. This site requires (6) Toro 8000 series controllers.
Controllers 'A' will serve as the primary controller.
Controllers 'A' &'D' in a back to back enclosure.
Controllers 'B' 8 'E' in a back to back enclosure.
Controllers 'C' 8 'F' in a back to back enclosure.
Contractor to provide 120V continuous power, see electrical plans.
Contractor to make final power hook up.
CONTROLLER RUNTIME DATA
System design is based on (6) valves running simultaneously. Controllers run
times should be based on an estimated 7.84 eto in June -Aug.
TURF SPRAY 109 MIN.
TURF ROTOR QTR. / HALF 269 MIN.
TURF ROTOR FULL 1079 MIN.
TOTAL SHRUB SPRAY 222 MIN.
SHRUB SM. ROTOR QTR. / HALF 540 MIN.
TOTAL MIN. RUN TIME. 2219 MIN. 36.92 HR
(6) VALVES SIMULTANEOUSLY 6.15 HR. RUN TIME JUN. - AUG.
BOOSTER FU1" F STATION
HYDROBOOST BOOSTER PUMP SYSTEM
Factory prepiped and prewired, mounted on a galvanized steel skid base, with
stainless steel control panel, flanged bronze fitted pump, three phase motor
TEFC, interconnecting piping and wiring, pressure reducing valve, full size
bypass line, system complete with liquid filled gauges and galvanized
steel enclosure mounted on a concrete pad.
HYDROBOOST MODEL IL385BSP130P2-20.0 CDEFLMNQ
SYSTEM TO CONSIST OF THE FOLLOWING:
PUMP: Peerless PV 3" x 3" x 8" inline type pump with flanged inlet and outlet:
impeller and wear ring to be bronze. Mechanical seal to be a John Crane type 21.
Pump volute to be top pull out for ease of removal. Volute casing, backplate and
bracket to be fusion bond epoxy coated. Pump designed for 384 GPM @ 150'.
MIN PUMP EFFICIENCY 78%
MOTOR: 20 HP, 3550 RPM, 460V, 3 Phase, frame 254JM, close coupled
to the pump. TEFC enclosure.
ISOLATION VALVES: Bray full lug butterfly valves with 10 position
handles and aluminum bronze disc. Also a 6" one in the by-pass.
CONCRETE PAD: 84" X 36" prestressed with rebar.
PIPING: 6" schedule 40 steel of easy to disassemble flanged construction bolted
together with SS nuts and bolts. All piping to be hot dipped galvanized after fabrication.
PRV/CHECK VALVE: 4" Bermad PRV/ check valve flanged.
0
4T
I
0 41 _ 42
Is
CITRUS AVENUE
43
44
lllr--1-r1 -�- I P ----/
000000000*00000000 [ .......
-r-
45 45
i
i 1's
TIPPING BUCKET
CHK
DATE 1/14/02
Strong box, back to back encloxure
MASTER CONTROLLER
Toro 8000 – 32 Station Controllers
S 0-700, 4' �
Master Valve Relay
Pressure Sensing Relay
C F BOOSTER PUMP LOCATION
Flow Sensor Board – Master
20
Controller to be closest to
UTILITY �— 6x9 CONC. PAD
Flow Sensor
CONC.
CONTROLLER:
PAD
A' & 'D' C42–T01-32+32 / MVR / PSR / TS 1 B
'B' & 'E' CA2–T01-32+32 / 2MVR / 2PSR
LINK CONTROLLERS W/ COMMON CABLE
SEE CONTROLLER NOTE.
'C' & 'F' CA2–TO 1-32+32 / 2MVR / 2PSR
CONTROLLER WIRE CHART
O
'A' – 'BLACK' WIRE LABELED
For Controller Assembly:
'B' – 'GREEN' WIRE LABELED
Contact: United Green Tech (800) 427-0779
'C' – 'RED' WIRE LABELED
Daryl Green
'D' – 'YELLOW' WIRE LABELED
'E' – 'BLUE' WIRE LABELED
w`}"{`r)
'F' – 'PURPLE'WIRE LABELED
For Controller "Com" Communication cable size, loop location and phone
COMMON WIRE TO BE WHITE WITH
connection to Master Controller 'A' –
CONTROLLER COLOR STRIP
Contact: Toro (916) 712-9046 EXT 4014
Cd
Wayne Owens
CONTROLLER LAYOUT
CONTROLLER ASEMBLY
—r-
46 46
00
n,D -
CM
�0 �ANDSC4pE,
♦�° 2782
'47
CAC
N
G
S I T E S C A P E S
Landscape Architecture
and Planning
19762 MacArthur Blvd.. Ste. 130
Irvins, CA. 92612
Richard Polhamus, Ucsnss CA—#2782
(949) 644-9370 (949) 476-1432 FAX
NO.1 REVISION
N U
V
W Z
m`2 W G4
a Fell
N Z
0
CAC/) a w
DVM
CHK
DATE 1/14/02
JOB # 01-017
1=3
of 39
00
Cd
O
Cd
}�
O
I�
w`}"{`r)
O
..�
00
Cd
w
�U
W�10r0,
Z
(d
V1
Mei
r --i
DVM
CHK
DATE 1/14/02
JOB # 01-017
1=3
of 39
E