HomeMy WebLinkAbout2991-1C C C C t L c 3 3 U u 3 r L GENERAL NOTES -STREET IMPROVEMENT PLANS 1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED. 2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION. 3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER. 4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL AT ALL TIMES. 7. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. 8. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT. 9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT-OF-WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE. 10. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORM&TION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION. 11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES. 12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS. 13. CURVE DATA REFERS TO THE FACE OF CURB. 14. STATIONING REFERS TO THE CENTERLINE OF STREETS EXCEPT WHERE OTHERWISE NOTED. 15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION. 16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCHMARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER. 17. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCHMARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT. 18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES. 20. ALL GRADING OPERATIONS SHALL BE DISCONTINUED WHEN SUSTAINED WIND VELOCITIES EXCEED 25 MILES PER HOUR. 21. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT-OF-WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL. 22. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 23. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED. 24. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS. FINAL25. THE t • AND D OF DRIVEWAY APPROACHAPRONS BE APPROVED AT THE TIME OF f - f AND SHALL CONFORM TO THE CITY OF FONTANA STANDARD DETAILS. 26. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH CONCRETE. 27, THE SEWER CONTRACTOR S, STAMP AN "S" IN THE FACE OF THE CURB AT THE LOCATION OF ` •' 28. NO CONCRETE SHALL BE PLACED f- AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. 29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS. i APPROVED SOIL STERILANT IS REQUIRED UNDER ASPHALT PAVEMENT PRIOR TO PLACEMENT. 31. PAVEMENT STRUCTURAL SECTIONS SHOWN ARE MINIMUM AND SUBJECT TO REVISION AND APPROVAL OF THE CITY ENGINEER AS DETERMINED BY SOILS TESTS TAKEN AFTER COMPLETION OF ROUGH GRADING. 32. ACTUAL THICKNESS OF A.C. PAVEMENT AND/OR BASE COURSEa - a STRUCTURALFOR SECTIONS• BE RECOMMENDED BY A GEOTECHNICAL -fRT AND SUBMITTED TO THE CITY OF FONTANA O. APPROVAL UPON COMPLETIONOF ROUGH GRADING. - 33. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL E RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR .O COMPLETION OF PAVING. , UPON COMPLETION OF CONSTRUCTION, SHALL RESTORE ALL - -BARRICADES, AND OTHER TRAFFIC • CONTROL DEVICES TO THE SATISFACTf OF THE CITY TRAFFIC 35. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS AND SIDEWALKS AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF • ENGINEER36. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE OF •'f WHO SHALL PROVIDE f `f DRAWINGS TO THE CITY ENGINEER. CITY OF FONTANA PACIFIC BELL CO. ATTN: CARLOS NAVARRO ATTN: VIRGINIA BECKER 8353 SIERRA AVENUE 3939 E. CORONADO STREET FONTANA, CA. 92335 ANAHEIM, CA. 92807 (909) 350-6632 (714) 666-5467 SO. CALIF. GAS COMPANY UNDERGROUND SERVICE ALERT ATTN: DENNIS FREEMAN (800) 227-2600 1981 W. LUGONIA AVENUE 1 REDLANDS, CA. 92374 COMCAST ( CABLE TV ) (909) 335-7547 ATTN: JACK HAYES EMERGENCIES: (800) 427-2200 1205 DUPONT AVE. ONTARIO, CA. 91761 SO. CALIF. EDISON COMPANY (909) 390-4738 300 N. PEPPER AVENUE 548 RIALTO, CA. 92376 GENERAL TELEPHONE COMPANY 909820-5598 - UNDERGROUND ATTN: STEVE HOCK 909 875-5100 - TRANSMISSION 1400 E. PHILIPS BLVD. 213 637-1233 - PIPELINES ONTARIO, CA. 91766 909 357-6223 - DISTRIBUTION (800) 422-4133 800 422-4133 FONTANA WATER COMPANY ATTN: MICHAEL J. McGRAW 8440 NUEVO AVENUE FONTANA CA. 92235 (909) 822-2201 FAX: (909) 823-5046 A RECORD DOCUMENT These Record Documents have been prepared based on information provided by others. The Design Professional has not verified the accuracy and/or completeness of this information and shall not be responsible for any errors or orni ;sions w 'c may be incorporated herein as a result wn DATE 10. COVERED CHANNEL FROM 21 R/W WESTGATE DRIVE TO R/W ARLINGTON COURT STREET STORM DRAINO IMPROVEMENT PLANS FOR TRACT NO. 15990 AND UVIVI. PCG 1 C SECTION A -A SCALE 1"=10' ; -RA-44- _AVFW SHEET INDEX MAP SCALE: 1 "=200' STREET LIGHTS -0 DIRECTION OF FLOW VACANT WESTGATE C PARKWAY DRAT APWA STD. 1 (TC ELEV'S PER SHEET 5 SU CONSTRUCTION NOTES 0- INSTALL 5800 LUMEN HPSV STREET LIGHT (70 WATT; #7) 25 FT. LUMINAIRE HEIGHT POLES SHALL BE MARBELITE OR APPROVED EQUAL. PER CITY STD. DWG # 1016 CONSTRUCT 4" AC PAVEMENT (Min.) OVER 12" OF 95% COMPACTED NATIVE (SEE GENERAL NOTES 31 & 32) 3 - CONSTRUCT 6" PCG CURB AND GUTTER PER CITY STD. DWG. NO. 1003 4 -CONSTRUCT DECORATIVE PAVEMENT PER LANDSCAPE ARCHITECT'S PLAN 5�-CONSTRUCT PCC DRIVE APPROACH PER CITY STD. DWG. 102, W=5.5', WIDTH= 16' G)_CONSTRUCT 4" PCC SIDEWALK PER CITY STD. DWG. NO. 1015 7 CONSTRUCT CURB RETURN ACCESS RAMP PER CITY STD. DWG. NO. 1006 8 ADJUST MANHOLE FRAME & COVER TO GRADE PER CITY STD. 109 9 INSTALL STOP SIGN PER CITY STD. DWG. NO. 139 10 INSTALL STREET NAME SIGN PER CITY STD. DWG. NO. 139 11 PROPOSED PER STREET IMPROVEMENT PLAN DWG NO. 2926 9500 LUMEN, H.P.S.V.: #10, 27' HIGH 12 REMOVE EXISTING CMP RISER AND 18" CMP PIPE 13 CONSTRUCT LOCAL DEPRESSION PER A.P.W.A. STDS DWG. 313-1, CASE "B" (SEE SHEET 10 OF 10) 14 CONSTRUCT CATCH BASIN PER A.P.W.A. STDS DWG 300-2 (SEE SHEET 10 OF 10) 15 INSTALL 30" R.C.P. 16 CONSTRUCT 4.5" AC PAVEMENT (Min.) OVER 12" OF 95% COMPACTED NATIVE (SEE GENERAL NOTES 31 & 32) 17 CONSTRUCT 8" PCC CURB AND GUTTER PER CITY STD, DWG 1003 D 18 CONSTRUCT CROSSGUTTER (MODIFIED MID -BLOCK 10' WIDE) PER STD DWG 104 1 g CONSTRUCT JUNCTION STRUCTURE PER APWA STD DWG 331-2 (SEE SHEET 10 OF 10) 20 CONSTRUCT PARKWAY DRAIN PER APWA STD DWG 151-1 (SEE SHEET 10 OF 10) 21 CONSTRUCT CONCRETE CHANNEL PER PARKWAY DRAIN SECTION A -A (SEE SHEET 1 OF 10) 22 CONSTRUCT LOCAL DEPRESSION PER A.P.W.A. STDS 313-1, CASE "A" (SEE SHEET 10 OF 10) 23 SAWCUT & REMOVE (MIN. 2' FROM EDGE OF PAVEMENT) EXISTING AC PAVEMENT TO CLEAN STRAIGHT LINE 0 TR 15990-1 TR • • 0 TOTAL L EA • a 41,043 S.F. 1,955 L.F. 1,096 S.F. 2,904 S.F. 20,096 S.F. 8 EA. 5 EA. 3 EA. 3 EA. 3 EA. 2 EA. 1 EA. 37,624 S.F. 1,427 L.F. 3,696 S.F. 4,325 S.F. 6 EA. 1 EA. 3 EA. 0 EA. MEL25 3 EA. 94 LF. 6,081 S.F. 792 L.F. 548 S.F. 1 EA. 1 EA. 1 EA. 1 EA. 22 L.F. 2 EA. 548 S.F. 78,667 S.F. 3,382 L.F. 1,096 S.F. 6,600 S.F. 24,421 S.F. 8 EA, 11 EA. 4 EA. 6 EA. 3 EA. 2 EA. 2 EA. 94 LF. 6,081 S.F. 792 L.F. 548 S.F. 1 EA. 1 EA. 22 L.F. 2 EA. 548 S.F. AFLMTON COURT UnnIFIFn PAPwwAY DRAIN RESSION PROFILE COVERED CHANNEL - -- SCALE 1"=10' P`IIenarne: M:\UWta\IaLl11\�IKttIJ\JI-I.UWIr