Loading...
HomeMy WebLinkAbout2988-3D 7 V 14 v Y) E y 5 L 10 11 IN 13 14 15 16 1'7 IU Wt PROFILE HORIZ: 1"= 40' VERT: 1"= 4' 20 GRAPHIC SCALE 40 0 20 40 80 160 ( IN FEET ) 1 inch = 40 ft. SEE SHEET 4 CENTERSTONE WAY $EWER LATERALS LOT NO. DESIGN STA. "AS—BUILT" STA. LOT NO. DESIGN STA. "AS—BUILT" STA. LOT NO. DESIGN STA. "AS—BUILT" STA. 24 19+27 34 13+05 69 15+52 25 19+21 35 12+73 70 14+55 26 18+25 36 11+45 71 14+25 27 17+93 37 11+45 72 13+23 28 16+92 38 10+43 73 12+92 29 16+60 64 18+89 74 11+92 30 15+62 65 18+17 75 11+61 31 15+32 66 17+18 76 10+58 32 33 14+35 14+05 67 68 16+87 15+80 71 7 p __4� MD E-0 ja DIAL TWO WORKING BEFORE DAYS BEFORE YOU DIG YOU DIG TOLL FREE 1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT PLANS PREPARED FOR SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS CENTERSTONE DEVELOPMENT COMPANY NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF Attn: HAL WOODS APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER THE CITY ENGINEER MAY REQUIRE 3500—B WEST LAKE CENTER DRIVE REVISIONS TO THE PLANS TO BRING THEM INTO SANTA ANA, CALIFORNIA 92704 CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT. 1(714) 437-0800 FAIRHAVEN DRIVE WINDERMERE WAY CONSTRUCTION NOTES Q— CONSTRUCT 4" VCP SEWER LATERAL & CLEANOUT PER CITY STD DWG NO 125 (SEE GENERIAL NOTE NO. 29) 2� CONSTRUCT PRECAST CONCRETE MANHOLE PER CITY STD. DWG. NO. 112 CONSTRUCT 8" VCP EXTRA STRENGTH SEWER MAIN INSTALL BACKWATER CHECK VALVE REVISIONS Engineer city No. A royal Date: A royal Date: BENCHMARK CALTRANS BENCHMARK NO. 8-17 BRASS CAP IN CONCRETE S.C.E. TOWER LEG. 343' N/0 HIGHLAND AVE., 0.2 MI. W/O SAN SEVAINE RD., IN SOUTH CONCRETE BASE OFA S.C.E. TOWER 19.5; 2.65 MI. W. ALONG HIGHLAND AVE. FROM SIERRA AVE. . ELEVATION' 14286090 Al Prepared By: ALLAFiD ENGINEEF3ING QROF ESS Lo" Civil Engineering - Land Surveying - Land Planning 8253 Sierra Avenue Fontana, California 92335 W No. 43976 356-1815 Fax (909) 356-1795 * Exp. 6/30/05 s� .Q 9TF Civil 0�I David S. Hammer, R.C.E. 43976 Date o� CAt �F (expires 6/30/2005) .�� �►., o r72"n 1AIJAi _ n c 2 _ 99_.l i_ .,.._, z Drawn By: IM JK/DEA/WF * Designed By: JF , ASRECORD DOCUMENT These Record Documents have been prepared based on information provided by others. The Design Professional has not verified the accuracy and/or completeness of this information and shall not be responsible for any errors or omissions is may be incorporated herein as a resu t O D TE CITY OF FONTANA, CALIFORNIA SEWER IMPROVEMENT PLANS TRACT NO. 15961 sale: FAIRHAVEN DRIVE 1 "= 40' STA. 10+00.00/IT9j19+37.00 May; _-;p 2002 Checked By Approved:1f '� � X, L L • to*Dwg. No. 1,�4 IZCq DH CITY ENGINEER R.C.E. 51152 2988 4-4\ —&Pr n\ 4onC4 cuinz Hain i nci iul I lu. ivi. \vn- \. i — \__ —, \. v­ ..+..�..�.........