HomeMy WebLinkAbout2988-1GENERAL NOTES
1 ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF
FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD
SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK"). ALL
REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION
UNLESS OTHERWISE NOTED.
2 WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT
DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE
PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY
REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION.
3 ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE
CITY ENGINEER.
4 CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA
COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE
START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT
LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC
RIGHT—OF—WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610.
5 THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES,
METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL
OF TRAFFIC CONTROLS, LATEST NON—METRIC EDITION UNLESS OTHERWISE
DIRECTED BY THE CITY TRAFFIC ENGINEER.
6 IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN
BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL
TIMES.
7 THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR
TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE
CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
8 THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET
IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR
OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION
OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN
FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR
GROUND MOVEMENT.
9 NO MATERIAL OR EQUIPMENT SHALL BE STORED IN TILE PUBLIC RIGHT OF
WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE.
10 THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM
AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND
ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION
TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND
SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE
EXCAVATION.
11 THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY
COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC,
CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER,
RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS.
ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR
TO WORK AROUND THEIR FACILITIES.
12 THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER
MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR
SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE
OPERATION AND WATER REQUIREMENTS.
13 STATIONING REFERS TO THE CENTERLINE OF SEWER EXCEPT WHERE
OTHERWISE NOTED.
14 ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE
ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE
PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE
PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING
DURING CONSTRUCTION.
15 THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS,
MONUMENT TIES OR BENCH , MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY
ENGINEER.
16 REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING
SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE
BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY
MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION
SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE
WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE
ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT.
17 THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND
BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED
AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY
VEHICLES.
18 THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF
DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES.
19 THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT
OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT
TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN
APPROVAL.
20 NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF
THE CITY INSPECTOR.
21 A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION.
FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE—WORKING OF
THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED.
22 CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES
FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE,
THE CITY ENGINEER MAY REQUIRE TEMPORARY NON—ERODEABLE SWALES
ENTERING OR LEAVING IMPROVEMENTS.
23 ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR
AND FINISH TO MATCH EXISTING CONCRETE.
24 IF SEWER CONSTRUCTION IS TO BE DONE IN PHASES, THE CONTRACTOR
SHALL PROVIDE A TERMINAL CLEANOUT AT THE PHASE BOUNDARY, NOT MORE
THAN 150 FEET FROM THE DOWNSTREAM MANHOLE, SEE CITY OF FONTANA
STANDARD DETAIL FOR TERMINAL CLEANOUT.
v
D, �:`. C7,
Q O
N
�i
D
DIAL TWO WORKING
°41' BEFORE ••••DAYS BEFORE
YOU DIGYOU DIG
o TOLL FREE 800-227-2600
i A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
25 SANITARY SEWER LINES SHALL BE CONSTRUCTED OF BELL AND SPIGOT OR
BAND SEAL TYPE VITRIFIED CLAY PIPE (V.C.P.) EXTRA STRENGTH CLASS AND
SHALL CONFORM TO THE PROVISIONS OF THE ASTM DESIGNATION C700 FOR
V.C.P.
26 NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT
PRIOR APPROVAL OF THE CITY ENGINEER.
27 SHORT VCP STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED
AT MANHOLE WALLS TO ALLOW FOR MINOR DEFLECTIONS IN ALIGNMENT.
28 PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING
FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY
APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY
CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS.
29 ALL 4" HOUSE LATERALS SHALL BE INSTALLED AT A 2% MINIMUM GRADE
UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER.
30 TERMINATE ALL 4" HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH
A PLUG 12" BELOW THE GROUND SURFACE. WHEN PUBLIC UTILITY EASEMENTS
EXIST NEXT TO THE STREET RIGHT OF WAY, THE LATERAL SHALL TERMINATE 3
FEET INSIDE THE LOT AS MEASURED FROM THE UTILITY EASEMENT.
31 THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE
CURB AT THE LOCATION OF THE SEWER LATERAL.
32 IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE
PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER
AND ALL AFFECTED AGENCIES IMMEDIATELY.
33 NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING
STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED.
34 ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED
PRIOR TO PAVING OF STREETS.
35 APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT
PAVEMENT PRIOR TO PLACEMENT.
36 ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE
RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION
OF PAVING.
37 UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL
SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO
THE SATISFACTION OF THE CITY TRAFFIC ENGINEER.
38 AS—BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE
ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY
ENGINEER.
CRY OF FONTANA, UTILITY NOTIFICATION LIST
CITY OF FONTANA
PACIFIC BELL CO.
ATTN: CARLOS NAVARRO
ATTN: VIRGINIA BECKER
8353 SIERRA AVENUE
3939 E. CORONADO STREET
FONTANA, CA. 92335
ANAHEIM, CA. 92807
(909) 350-6632
(714) 666-5467
SO. CALIF. GAS COMPANY
UNDERGROUND SERVICE ALERT
ATTN: DENNIS FREEMAN
(800) 227-2600
1981 W. LUGONIA AVENUE
0-5
REDLANDS, CA. 92374
)
COMCAST ( CABLE TV(909)
335-747
1 JACK HAYES
EMERGENCIES: (800) 427-2200
05 DUPONT AVE.
S-0—UTF17
ONTARIO, CA. 91761
SO. CALIF. EDISON COMPANY
(909) 390-4738
300 N. PEPPER AVENUE
UJ
RIALTO, CA. 92376
GENERAL TELEPHONE COMPANY
909820-5598 — UNDERGROUND
ATTN: STEVE HOCK
909 875-5100 — TRANSMISSION
1400 E. PHILLIPS BLVD.
213 637-1233 — PIPELINES
ONTARIO, CA. 91766
909 357-6223 — DISTRIBUTION
(800) 422-4133
800 422-4133
FONTANA WATER COMPANY
CRAWFORD CANYON MUTUAL WATER CO.
ATTN: MICHAEL J. MCGRAW
ATTN: BILL VANDERKIEFT, JR.
8440 NUEVO AVENUE
(619) 868-6040
FONTANA CA. 92235
(909) 822-2201
FAx: (909) 823-5046
CONSTRUCTION NOTES
W
z_
Q
W
C" C
1
Q
0 Cn
U
L
MH #1
10-- CONSTRUCT 4" VCP SEWER LATERAL & CLEANOUT PER CITY STD DWG NO 125
(SEE GENERIAL NOTE NO. 29)
2�—CONSTRUCT PRECAST CONCRETE MANHOLE PER CITY STD. DWG. NO. 112
CONSTRUCT 8" VCP EXTRA STRENGTH SEWER MAIN
REMOVE EXISTING 8" PLUG, CONNECT TO EXISTING 8" VCP STUB
INSTALL BACKWATER CHECK VALVE
ENCASE 4" V.C.P. SEWER PER DETAIL "A" SEE SHEET 4 OF 5
PLANS PREPARED FOR
SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS CENTERSTONE DEVELOPMENT COMPANY
NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF Attn: HAL WOODS
APPROVAL SHOWN HEREON AND CARRIED FORTH IN A
DILIGENT MANNER THE CITY ENGINEER MAY REQUIRE 3500—B WEST LAKE CENTER DRIVE
REVISIONS TO THE PLANS TO BRING THEM INTO SANTA ANA, CALIFORNIA 92704
CONFORMANCE WITH CONDITIONS AND STANDARDS
IN EFFECT. 1(714) 437-0800
CITY OF FONTANA
SEWER IMPROVEMENT PLANS
7% Mal
I n
lnyx�" 2 Ll WE RM
LRECORD DOCiT"ENT
These Record Documents have been prepared
based on information provided by others. The
Design Professional has not verified the accuracy
and/or completeness of this information and shall
not be responsible for any errors or omissions
c may be incorporated herein as a result
D TE
76 EA.(2,304 LF)
13 EA.
3125 L.F.
1 EA.
23 EA.
13 L.F.
TABLE: 200-1.2(A)
SIEVE SIZE
PERCENTAGE
PASSING SIEVES
1 1/2 -
2"1"
ill
-
3/4"
100
1/2"
90-100
3/8"
20-60
NO.4
0-15
NO.8
0-5
ASTM C 131
TEST GRADING
B
INDEX MAP
SCALE: 1 "=100'
3" MAX SIZE NATIVE
SOIL, COMPACTED 95�
6" MIN. 6" MIN.
10" MAX. 10" MAX.
Ijt_.ii
I
i
6" MAX SIZE NATIVE
SOIL, COMPACTED 90
Y I 1" MAX. SIZE SELECTED
NATIVE BEDDING COMPACTED
TO 90%
1/2" CRUSHED -
STONE BEDDING I I w o
PER STD. SPECS.
FOR PUBLIC WORKS
�i .... ,:.,: il; ON
CONSTRUCTION t.
TABLE 200-1.2(A)
SHOWN BELOW
8" VCP
TYPICAL BEDDING FOR 81, VCP
10' OR DEEPER
SCALE: 1 " = 2'
REVISIONS Engineer city BENCHMARK
No. Approval Date: Approval Date:
CALTRANS BENCHMARK NO. 8-17
BRASS CAP IN CONCRETE S.C.E. TOWER LEG.
343' N/0 HIGHLAND AVE., 0.2 MI. W/O SAN
SEVAINE RD., IN SOUTH CONCRETE BASE OF
S.C.E. TOWER 19.5; 2.65 MI. W. ALONG
HIGHLAND AVE. FROM SIERRA AVE.
. /1 .. Z I I 7�- / newt _ ., ___ ELEVATION: 1428.6090
ALLARD ENGINEERING
Civil Engineering - Land Surveying - Land Planning
8253 Sierra Avenue
Fontana, California 92335
( 9) 356-1815 Fax (909) 356-1795
�5- 0 L
David S. Hammer, A.C.E. 43976 Date
(expires 6/30/2005)
W
D
z
UJ4
U
w
W
m
BASELINE AVENUE
Project Location
VICINITY
MAP
LI FTO N ST.
3" MAX SIZE NATIVE
SOIL, COMPACTED 95�
6" MIN. 6" MIN.
10" 3MAX. 10" MAX.
IAV..,...... s
6" MAX SIZE NATIVE -;:j N R
SOIL, COMPACTED 907. E
Q�pFESS 10\
No. 43976
Exp, 6/30/05
C I VI\ -
F CRL1
8" VCP
CHANNEL
1 MAX. SIZE SELECTED
NAT'VE BEDDING COMPACTED
TO 90%
�z
400
61
TYPICAL BEDDING FOR 8' VCP
LESS THAN 10' DEEP
SCALE: 1 " = 2'
CITY OF FONTANA, CALIFORNIA
SEINER IMPROVEMENT PLANS
M
Drawn Scale:
TRACT NO. 15961 Scal 1 "= 40'
�
i Designed By: TITLE SH E 1T
Date:
JF — May, 2002
Checked B s Z -L Dwg. No. 1
Approved:
k7C=1 DH C TY ENGINEER R.C.E. 51 152 2M 5
r lleflV(TIC: M: �VYYV � I ! J6J I �JCYYCR � I J�V I —JYYR I .VYYL
CARTER
AVENUE
�f
HIGHLAND
HI(:HLAN
D AV
LAND
AN I E
VE
S-0—UTF17
QI
UJ
Uj
UJ
z
U)I a
a
AVENUE
WALNUT
o
9
r
z
UJW
UJ
U
W
D
z
UJ4
U
w
W
m
BASELINE AVENUE
Project Location
VICINITY
MAP
LI FTO N ST.
3" MAX SIZE NATIVE
SOIL, COMPACTED 95�
6" MIN. 6" MIN.
10" 3MAX. 10" MAX.
IAV..,...... s
6" MAX SIZE NATIVE -;:j N R
SOIL, COMPACTED 907. E
Q�pFESS 10\
No. 43976
Exp, 6/30/05
C I VI\ -
F CRL1
8" VCP
CHANNEL
1 MAX. SIZE SELECTED
NAT'VE BEDDING COMPACTED
TO 90%
�z
400
61
TYPICAL BEDDING FOR 8' VCP
LESS THAN 10' DEEP
SCALE: 1 " = 2'
CITY OF FONTANA, CALIFORNIA
SEINER IMPROVEMENT PLANS
M
Drawn Scale:
TRACT NO. 15961 Scal 1 "= 40'
�
i Designed By: TITLE SH E 1T
Date:
JF — May, 2002
Checked B s Z -L Dwg. No. 1
Approved:
k7C=1 DH C TY ENGINEER R.C.E. 51 152 2M 5
r lleflV(TIC: M: �VYYV � I ! J6J I �JCYYCR � I J�V I —JYYR I .VYYL