HomeMy WebLinkAbout2982-1GENERAL NOTES
1 ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE
CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN
BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS
OTHERWISE NOTED.
2 WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE
RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL
IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION.
3 ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER.
4 ADVANCE CONSTRUCTION SIGNING INDICATING DURATION OF PROJECT SHALL BE IN PLACE ONE WEEK PRIOR
TO IMPLEMENTING DETOURS.
5 CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT
DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL
BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC
RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610.
6 THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES
DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION
UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER.
7 IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER
TRAFFIC CONTROL DEVICES AT ALL TIMES.
8 THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5
FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
9 THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED
BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF
THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET
SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT.
10 NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A
SEPARATE PERMIT FOR THAT PURPOSE.
11 THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT
SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND
ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO.
THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS
BEFORE EXCAVATION.
12 THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT
LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC
WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES
SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES.
13 THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE
AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR
VALVE OPERATION AND WATER REQUIREMENTS.
14 STATIONING REFERS TO THE CENTERLINE OF STORM DRAIN EXCEPT WHERE OTHERWISE NOTED.
15 ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR
TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE
PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION.
16 THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS
WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER.
17 REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT
TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR.
SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED.
THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO
MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT.
18 THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A
MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS
AND EMERGENCY VEHICLES.
19 THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING
ADEQUATE WATERING, AT ALL TIMES.
20 THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED
ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT
PRIOR WRITTEN APPROVAL.
21 NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
22 A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED
DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS
OBTAINED.
23 CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET
IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY
NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS.
24 ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING
CONCRETE.
25 NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE CITY
ENGINEER.
26 PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION AND
LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY
CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS.
27 IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE
CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY.
28 NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED,
INSPECTED AND APPROVED.
29 ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS.
30 APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT.
31 ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY
THE PAVING CONTRACTOR UPON COMPLETION OF PAVING.
32 UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES,
AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER.
33 AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL
PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER.
Fi CORD DRAVVIN
i... OHQ -I)RAWINCS HAVE BFEN
PARI ON THE IASIS OF INFORMATION Cs «''>LE
FURN.'SHF i BY OTHFRS. THE ENGINEER WILL NO C47,
I
RESPONSIBLE FOR ANY ERRORS OR OMISSIONS ,�IHI w
HAVE BEEN INCORPORATED INTO THE DOCUMENTS A"
A RESULT 1-TRFO
97 9895
/� •y 103 102 101 100 99
98 $
i e
-aa
:_ 3 i
SAY
P .
INDEX MAP
SCALE: 1 "=160'
CITY OF FONTANA UTILITY NOTIFICATION LIST
CITY OF FONTANA
ATTN: CARLOS NAVARRO
8,353 SIERRA AVENUE
FONTANA, CA 92335
(909) 350-6632
SO. CALIFORNIA GAS COMPANY
ATTN. ALAN KESELOFF
16231 VALLEY BLVD.
FONTANA, CA. 92335
(909) 335-7781
EMERGENCIES: (800) 427-2200
SO. CALIFORNIA EDISON COMPANY
ATTN: JAIME AMESZCUA
(909) 357-6581
7951 REDWOOD AVENUE
FONTANA, CA. 92335
(909) 820-5598 UNDERGROUND
(909) 820-5137 TRANSM 15SIONS
(213) 637-1233 PIPELINES
(909) 357-6589 DISTRIBUTION
(800) 227-2600
CRAWFORD CANYON MUTUAL WATER CO.
ATTN: BILL VANDERKIEFT, JR.
(619) 868-6040
UNDERGROUND SERVICE ALERT
(800) 227-2600
TOLL FREE 1-800-227-2600
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
REV. I REVISION DESCRIPTION
PACIFIC BELL CO.
ATTN: VIRGINIA BECKER
3939 E.CORONADO STREET
ANAHEIM, CA 92807
(714) 666-5467
COMCAST (CABLE TV)
ATTN: JACK HAYES
1205 DUPONT AVENUE FONTANA,
ONTARIO, CA. 91761
(909) 390-4736 EXT. 3055
6" MIN.
L'17-T
III =
N III 8 MAX. =III
I III=
Z -_
o '
N a III
w BELL=_ Z
a- III =
a III
IIII� II
III '
0.6'D' III- III-
STORM DRAIN/
ZGRANULAR BEDDING FROM SELECTED
TRENCH SIDE MATERIAL FOR PIPE
10' OR GREATER IN DEPTH USE
NOTES: 1/2 CRUSHED STONE BEDDING.
1. TRENCH WIDTH SHALL BE CONTROLLED NOTE: COMPACTION SHALL BE 90% IN ALL
TO TOP OF PIPE ZONE. ZONES UNLESS OTHERWISE SPECIFIED.
2. TRENCH DEPTHS OF GREATER THAN 5' TRENCH STABILITY SHALL CONFORM
SHALL HAVE ADEQUATE SHORING. TO CAL -OSHA REQUIREMENTS.
3. CLASS II AGG.BASE ALL TRENCHES
LESS THAN 100' IN LENGTH.
TRENCH DETAIL
NOT TO SCALE
it MAIN LINE RCP OR
REINFORCED MONOLITHIC
ARCH, SEE NOTE 2
80 mm (31 MIN. I�►��o
_j
H
1:1
SLOPE OR GREATER
STANDARDETRIC �N
PUBLIC WORKS STANDARDS INC., 1984
GREENBOOKCOMMITTEE
OR
ADEQUATE SHORING
o
Z&
I TO 75 mm
I (3") R
o o~
a
UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN OR NOT SHOWN ON THESE
2 az
90% COMPACTED
NATIVE BACKFILL
\/
/%
W Y.
W O
APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS AND THAT THE
V/ W
U) Mcc
FONTANA, CA 92335 THE
3" MAX. SIZE
(909) 822-2201 EXT. 323 FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER.
GRANULAR BEDDING FROM
ATS/MJG
CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL REPORT
ALL DISCREPANCIES TO THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK.
SELECTED TRENCH SIDE
DATE
ENGR.
CITY
MATERIAL (1" MAX. SIZE).
\
Ld
-RE 62183 EXP. 9-30-05
6" MIN.
L'17-T
III =
N III 8 MAX. =III
I III=
Z -_
o '
N a III
w BELL=_ Z
a- III =
a III
IIII� II
III '
0.6'D' III- III-
STORM DRAIN/
ZGRANULAR BEDDING FROM SELECTED
TRENCH SIDE MATERIAL FOR PIPE
10' OR GREATER IN DEPTH USE
NOTES: 1/2 CRUSHED STONE BEDDING.
1. TRENCH WIDTH SHALL BE CONTROLLED NOTE: COMPACTION SHALL BE 90% IN ALL
TO TOP OF PIPE ZONE. ZONES UNLESS OTHERWISE SPECIFIED.
2. TRENCH DEPTHS OF GREATER THAN 5' TRENCH STABILITY SHALL CONFORM
SHALL HAVE ADEQUATE SHORING. TO CAL -OSHA REQUIREMENTS.
3. CLASS II AGG.BASE ALL TRENCHES
LESS THAN 100' IN LENGTH.
TRENCH DETAIL
NOT TO SCALE
it MAIN LINE RCP OR
REINFORCED MONOLITHIC
ARCH, SEE NOTE 2
80 mm (31 MIN. I�►��o
_j
H
I
(
IROUND
STANDARDETRIC �N
PUBLIC WORKS STANDARDS INC., 1984
GREENBOOKCOMMITTEE
EDGE i
as
o
Z&
I TO 75 mm
I (3") R
o o~
a
UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN OR NOT SHOWN ON THESE
2 az
E
CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY
W Y.
W O
APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS AND THAT THE
V/ W
U) Mcc
FONTANA, CA 92335 THE
PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING
(909) 822-2201 EXT. 323 FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER.
FAX. (909) 823-5046
ATS/MJG
CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL REPORT
ALL DISCREPANCIES TO THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK.
i e r,
L—� `
oT °
uSTA. POINT
2
CONNECTOR P
80 mm SEE NOTE 3
C (3") MIN.
STA. POINT
LATERAL
SEE NOTE 3
PLAN
SPUR IOM O 450 mm
(+3 OR #4 O 180)
OC TIE BAR
REINFORCING STEEL I G BARS 15M O 150 mm
80 mm (31) MIN.
SPRING I iv
LINE�ROUNOI o _ 113 m
EDGES r ELEV. R
E BARS 15M.0
ELEV. S / O 80 mm (3) OC
F BARS 15M (eW
O 75 mm (3") OC
UNDISTURBEDCONCRETE CRADLE,
EARTH H I H 265-C-14 (450-C-2000).
SEE NOTE 9
SECTION Z—Z
t. LATERAL/
CONNECTOR PIPE
G BARS
15M O 150 mm
(+4 O 6") OC
IOM O 450 mm
(+3 OR •4 0 181)
OC TIE BARS
E AND F BARS
15M O 75 mm
(#5 O 31) OC.
SEE NOTE 8
SECTION M—M
BARS
G BARS
AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER
PROMULGATED BY THE
JUNCTION STRUCTURE - PIPE TO PIPE INLET
STANDARDETRIC �N
PUBLIC WORKS STANDARDS INC., 1984
GREENBOOKCOMMITTEE
��
ID >_ 600mm(24) OR ID > 1/2 MAIN LINE ID
331 -2
REV. 1996
SHEET I OF 2
USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION
PRIVATE ENGINEER'S NOTICE TO CONTRACTORS:
GENERAL TELEPHONE CO.
JUNCTION STRUCTURE -PIPE TO PIPE INLET
ID > 600 mm 24") OR> 1/2 MAIN LINE ID
ATTN: STEVE HOCK THE
EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES
1400 E. PHILLIPS BLVD. SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS; TO
ONTARIO, CA. 91766 THE
BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE
(800) 422-4133 SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY
MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE DRAWINGS. THE
CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND RESPONSIBILITY FOR THE
UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN OR NOT SHOWN ON THESE
DRAWINGS.
THE
CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY
FOR THE JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS
FONTANA WATER COMPANY PROJECT; INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS SHALL
APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS AND THAT THE
ATTN: AL KROHN CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER AND THE ENGINEER
8440 NUEVO AVENUE HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED IN CONNECTION WITH
FONTANA, CA 92335 THE
PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING
(909) 822-2201 EXT. 323 FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER.
FAX. (909) 823-5046
ATS/MJG
CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL REPORT
ALL DISCREPANCIES TO THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK.
DATE
ENGR.
CITY
DATE
SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT
Ld
-RE 62183 EXP. 9-30-05
41
R A
d `'+ ✓ �oz
CYN. RD.
w
COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL
SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER,
THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO
BRING THEM INTO CONFORMANCE WITH CONDITIONS AND
C17Y ENGINEER R.C.E. 51152 DATE
�
Q
co
F
h
m
w
w
w
w
Q Z
m
Q
U
Uw
Li
STANDARDS IN EFFECT.
V)
0
-'
VICINITY MAP (NTS)
NOTES
I. THIS JUNCTION STRUCTURE SHALL BE USED WHEN THE OUTSIDE DIAMETER
OF THE LATERAL IS GREATER THAN 1/2 THE INSIDE DIAMETER D OF THE
MAIN LINE. OR WHEN THE INSIDE DIAMETER B OF THE LATERAL IS GREATER
THAN 600 mm (241. B SHALL NOT EXCEED .75 D OR 975 mm (39").
2. IF THE MAIN LINE IS A REINFORCED MONOLITHIC ARCH STORM DRAIN,
D SHALL REFER TO THE CLEAR SPAN OF THE ARCH. REINFORCING STEEL
SHALL BE CUT AND BENT INTO THE JUNCTION STRUCTURE IN THE SAME
MANNER AS FOR A PIPE. A CONCRETE CRADLE IS NOT REQUIRED FOR A
REINFORCED MONOLITHIC ARCH.
3. STATIONS SHOWN ON THE PROJECT DRAWINGS FOR LATERALS APPLY AT THE
INTERSECTION OF CENTER LINES OF MAIN LINE AND LATERAL. STATIONS
SHOWN ON THE PROJECT DRAWINGS FOR CATCH BASIN CONNECTOR PIPES
APPLY AT THE INTERSECTION OF THE INSIDE WALL OF THE MAIN LINE WITH
THE CONNECTOR PIPE CENTER LINE.
4. VALUES .FOR A. B. C AND D SHALL BE SHOWN ON THE PROJECT DRAWINGS.
ELEVATION R AND ELEVATIONS SHALL BE SHOWN ONLY WHEN REQUIRED PER
NOTE 5.
5. a. ELEVATIONS R AND S NEED NOT BE SHOWN ON THE PROJECT DRAWINGS
IF THE INLET PIPE IS TO ENTER THE MAIN LINE RADIALLY.
b. ELEVATION R SHALL BE SHOWN ON THE PROJECT DRAWINGS ONLY IF A
STUB IS TO BE PROVIDED IN THE MAIN LINE FOR FUTURE CONNECTION
OF AN INLET PIPE.
c. ELEVATION S SHALL BE SHOWN ON THE PROJECT DRAWINGS IF AN INLET
PIPE IS TO ENTER THE MAIN LINE OTHER THAN RADIALLY. INLET PIPE
SHALL BE LAID ON A STRAIGHT GRADE FROM ELEVATION S TO THE
CATCH BASIN OR GRADE BREAK IN LINE.
6. THE INLET PIPE SHALL ENTER THE MAIN LINE RADIALLY UNLESS OTHERWISE
INDICATED. THE INLET PIPE MAY ENTER THE MAIN LINE OTHER THAN
RADIALLY IF ANGLE A IS GREATER THAN 450, B IS LESS THAN OR EQUAL TO
600 mm (24") AND THE OUTSIDE DIAMETER OF THE INLET PIPE IS LESS THAN
.5 D: OTHERWISE. STANDARD PLAN 340 SHALL BE USED.
7. NO MORE THAN ONE OPENING SHALL BE MADE IN ANY ONE SECTION OF PIPE.
8. THE OPENING FOR THE BREAKOUT SHALL BE RECTANGULAR AND CUT NORMAL
TO THE PIPE SURFACE WITHOUT DAMAGING THE REINFORCING STEEL. THE
TRANSVERSE REINFORCEMENT OF THE MAIN LINE SHALL BE CUT AT THE
CENTER OF THE OPENING AND BENT INTO THE TOP AND BOTTOM SLABS OF
THE SPUR.
9. THE MAIN LINE SHALL BE REINFORCED WITH A CONCRETE CRADLE AND
ENCASEMENT (AS APPLICABLE). A CONCRETE ENCASEMENT IS REQUIRED IF A
JOINT IN THE MAIN LINE FALLS WITHIN THE LIMITS OF THE CRADLE. THE
CONCRETE ENCASEMENT SHALL EXTEND 300 mm (12") ABOVE THE TOP OF THE
MAIN LINE AND TO THE LIMITS OF THE CRADLE.
IF CONNECTING TO AN EXISTING STORM DRAIN, PORTION OF CRADLE
OPPOSITE INLET MAY BE OMITTED.
10. REINFORCING STEEL SHALL CONFORM TO ASTM A 615M, GRADE 300, (ASTM A 615,
GRADE 40), AND BE PLACED 40 mm (1 1/2") CLEAR FROM CONCRETE SURFACES.
UNLESS OTHERWISE SHOWN F BARS SHALL BE CARRIED TO A POINT NOT LESS
THAN J DISTANCE FROM CENTER LINE WITH J=7D/12 + 150 mm (60).
11. FLOOR OF THE SPUR SHALL BE STEEL -TROWELED TO THE SPRING LINE OF
THE SPUR.
12. DIMENSIONS SHOWN ON THIS PLAN FOR METRIC AND ENGLISH UNITS ARE NOT
EXACT EQUAL VALUES. IF METRIC VALUES ARE USED. ALL VALUES USED FOR
CONSTRUCTION SHALL BE METRIC VALUES, EXCEPT REINFORCING BARS SIZES IN
ENGLISH UNITS MAY BE SUBSTITUTED FOR METRIC BAR SIZES. IF ENGLISH UNITS
ARE USED, ALL VALUES USED FOR CONSTRUCTION SHALL BE ENGLISH UNITS.
AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER
STANDARD PLAN
MERIC
331 - 2
SHEET 2 OF 2
JUNCTION STRUCTURE -PIPE TO PIPE INLET
ID > 600 mm 24") OR> 1/2 MAIN LINE ID
LF
63
LF
2
EA
1
EA
> �A�
No, 62183 N �
10601 CHURCH STREET, STE. 107
DRAWN
ATS/J/JKD/MJG
SIERRA LAKES - TRACT 16097
SCALE: "-40
a
Exp; 9-30-05
RANCHO CUCAMONGA, CA 91730
PHONE (909) 948-1311
TITLE HEET
_J
DESIGNED BY:
DATE:
FEB. 2002
��
ATS/MJG
- ----
T CI VIS- ��ct
FOFCALIF�
Date : I- -LI 'd ti
N
P VED BY:/
DUNCAN
Ld
-RE 62183 EXP. 9-30-05
41
R A
d `'+ ✓ �oz
CYN. RD.
w
C17Y ENGINEER R.C.E. 51152 DATE
�
Q
co
F
h
m
w
w
w
w
Q Z
m
Q
U
Uw
Li
SUMMTQ AVENUE
V)
0
-'
S IT
w
Z
V)
U
Q
�
O
SIER
w
KES
I_
PARK WA
J
Z
U
>
HIGHLAND
AVENUE
m
Q
2
W
w
m
BASELINE
AVENUE
VICINITY MAP (NTS)
NOTES
I. THIS JUNCTION STRUCTURE SHALL BE USED WHEN THE OUTSIDE DIAMETER
OF THE LATERAL IS GREATER THAN 1/2 THE INSIDE DIAMETER D OF THE
MAIN LINE. OR WHEN THE INSIDE DIAMETER B OF THE LATERAL IS GREATER
THAN 600 mm (241. B SHALL NOT EXCEED .75 D OR 975 mm (39").
2. IF THE MAIN LINE IS A REINFORCED MONOLITHIC ARCH STORM DRAIN,
D SHALL REFER TO THE CLEAR SPAN OF THE ARCH. REINFORCING STEEL
SHALL BE CUT AND BENT INTO THE JUNCTION STRUCTURE IN THE SAME
MANNER AS FOR A PIPE. A CONCRETE CRADLE IS NOT REQUIRED FOR A
REINFORCED MONOLITHIC ARCH.
3. STATIONS SHOWN ON THE PROJECT DRAWINGS FOR LATERALS APPLY AT THE
INTERSECTION OF CENTER LINES OF MAIN LINE AND LATERAL. STATIONS
SHOWN ON THE PROJECT DRAWINGS FOR CATCH BASIN CONNECTOR PIPES
APPLY AT THE INTERSECTION OF THE INSIDE WALL OF THE MAIN LINE WITH
THE CONNECTOR PIPE CENTER LINE.
4. VALUES .FOR A. B. C AND D SHALL BE SHOWN ON THE PROJECT DRAWINGS.
ELEVATION R AND ELEVATIONS SHALL BE SHOWN ONLY WHEN REQUIRED PER
NOTE 5.
5. a. ELEVATIONS R AND S NEED NOT BE SHOWN ON THE PROJECT DRAWINGS
IF THE INLET PIPE IS TO ENTER THE MAIN LINE RADIALLY.
b. ELEVATION R SHALL BE SHOWN ON THE PROJECT DRAWINGS ONLY IF A
STUB IS TO BE PROVIDED IN THE MAIN LINE FOR FUTURE CONNECTION
OF AN INLET PIPE.
c. ELEVATION S SHALL BE SHOWN ON THE PROJECT DRAWINGS IF AN INLET
PIPE IS TO ENTER THE MAIN LINE OTHER THAN RADIALLY. INLET PIPE
SHALL BE LAID ON A STRAIGHT GRADE FROM ELEVATION S TO THE
CATCH BASIN OR GRADE BREAK IN LINE.
6. THE INLET PIPE SHALL ENTER THE MAIN LINE RADIALLY UNLESS OTHERWISE
INDICATED. THE INLET PIPE MAY ENTER THE MAIN LINE OTHER THAN
RADIALLY IF ANGLE A IS GREATER THAN 450, B IS LESS THAN OR EQUAL TO
600 mm (24") AND THE OUTSIDE DIAMETER OF THE INLET PIPE IS LESS THAN
.5 D: OTHERWISE. STANDARD PLAN 340 SHALL BE USED.
7. NO MORE THAN ONE OPENING SHALL BE MADE IN ANY ONE SECTION OF PIPE.
8. THE OPENING FOR THE BREAKOUT SHALL BE RECTANGULAR AND CUT NORMAL
TO THE PIPE SURFACE WITHOUT DAMAGING THE REINFORCING STEEL. THE
TRANSVERSE REINFORCEMENT OF THE MAIN LINE SHALL BE CUT AT THE
CENTER OF THE OPENING AND BENT INTO THE TOP AND BOTTOM SLABS OF
THE SPUR.
9. THE MAIN LINE SHALL BE REINFORCED WITH A CONCRETE CRADLE AND
ENCASEMENT (AS APPLICABLE). A CONCRETE ENCASEMENT IS REQUIRED IF A
JOINT IN THE MAIN LINE FALLS WITHIN THE LIMITS OF THE CRADLE. THE
CONCRETE ENCASEMENT SHALL EXTEND 300 mm (12") ABOVE THE TOP OF THE
MAIN LINE AND TO THE LIMITS OF THE CRADLE.
IF CONNECTING TO AN EXISTING STORM DRAIN, PORTION OF CRADLE
OPPOSITE INLET MAY BE OMITTED.
10. REINFORCING STEEL SHALL CONFORM TO ASTM A 615M, GRADE 300, (ASTM A 615,
GRADE 40), AND BE PLACED 40 mm (1 1/2") CLEAR FROM CONCRETE SURFACES.
UNLESS OTHERWISE SHOWN F BARS SHALL BE CARRIED TO A POINT NOT LESS
THAN J DISTANCE FROM CENTER LINE WITH J=7D/12 + 150 mm (60).
11. FLOOR OF THE SPUR SHALL BE STEEL -TROWELED TO THE SPRING LINE OF
THE SPUR.
12. DIMENSIONS SHOWN ON THIS PLAN FOR METRIC AND ENGLISH UNITS ARE NOT
EXACT EQUAL VALUES. IF METRIC VALUES ARE USED. ALL VALUES USED FOR
CONSTRUCTION SHALL BE METRIC VALUES, EXCEPT REINFORCING BARS SIZES IN
ENGLISH UNITS MAY BE SUBSTITUTED FOR METRIC BAR SIZES. IF ENGLISH UNITS
ARE USED, ALL VALUES USED FOR CONSTRUCTION SHALL BE ENGLISH UNITS.
AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER
STANDARD PLAN
MERIC
331 - 2
SHEET 2 OF 2
JUNCTION STRUCTURE -PIPE TO PIPE INLET
ID > 600 mm 24") OR> 1/2 MAIN LINE ID
CONSTRUCTION NOTES
11 -- INSTALL 24" RCP - D LOAD PER PROFILE.
�— INSTALL 30" RCP - D LOAD PER PROFILE.
3�-- INSTALL 30" RCP - D LOAD PER PROFILE
WITH CONCRETE BACKFILL PER DETAIL ON SHT. 2.
44 CONSTRUCT JUNCTION STRUCTURE PER APWA STD 331-2.
5a— RELOCATE CONFLICTING WATER CROSSING (BY FWC FORCES)
BENCH MAPoC: No. 615 BA31S OF BEA�`�
RAILROAD SPIKE AT INTERSECTION THE BEARING OF N89'30'06'E ALONG
OF CITRUS AVE. AND LOS CECROS THE No. LINE OF SEC. 30, T.1N.,R.5W.,
AVE., IN POWER POLE NO. 9011E B.M. PER R.S. 58/5, WAS USED AS
ON THE EAST SIDE OF CITRUS AVE. THE BASIS OF BEARINGS FOR THIS
EL-EVAIM 1467.59 LAN.
QUANTITIES
240
LF
178
LF
63
LF
2
EA
1
EA
. Innn n n.nn MIA Ml
Prepared Under The Supervision Of :
CITY OF FONTANA, CALIFORNIA
I
OF
HpMAS ��c�,y�
PREPARED IN THE OFFICE OF
MADOLE AND ASSOCIATES, INC.
W
STORM DRAIN IMPROVEMENT PLANS
> �A�
No, 62183 N �
10601 CHURCH STREET, STE. 107
DRAWN
ATS/J/JKD/MJG
SIERRA LAKES - TRACT 16097
SCALE: "-40
a
Exp; 9-30-05
RANCHO CUCAMONGA, CA 91730
PHONE (909) 948-1311
TITLE HEET
_J
DESIGNED BY:
DATE:
FEB. 2002
��
ATS/MJG
- ----
T CI VIS- ��ct
FOFCALIF�
Date : I- -LI 'd ti
CHECKED BY: ---
P VED BY:/
DRAWING NO.: 1
-RE 62183 EXP. 9-30-05
R A
d `'+ ✓ �oz
2982
2
Ill
C17Y ENGINEER R.C.E. 51152 DATE
co
. Innn n n.nn MIA Ml