HomeMy WebLinkAbout2899-1GENERAL NOTES FOR SEWER 1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED. 2. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 3. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS. 4. STATIONING REFERS TO THE CENTERLINE OF SEWER EXCEPT WHERE OTHERWISE NOTED. 5. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS. 6. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION. HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-422-4133 TWO WORKING DAYS BEFORE EXCAVATION. 7. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING. 8. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISON, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES. 9. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER. 10. WHEN CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION. 11. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT. 12. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE. 13. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. 14. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT. 15. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. 16. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 17, THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT-OF-WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL. 18. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL AT ALL TIMES. 19. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED. 20. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER. 21. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION. 22. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS. 23. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY. 24. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCHMARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER. 25. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCHMARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT. 26. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CLOSURE AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 27. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT-OF-WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE. 28. SANITARY SEWER LINES SHALL BE CONSTRUCTED OF BELL AND SPIGOT OR BAND SEAL TYPE VITRIFIED CLAY PIPE (V.C.P.) EXTRA STRENGTH CLASS AND SHALL CONFORM TO THE PROVISIONS OF THE ASTM DESIGNATION C700 FOR V.C.P. 29. TERMINATE ALL 4" HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH A PLUG 12" BELOW THE GROUND SURFACE. WHEN PUBLIC UTILITY EASEMENTS EXIST NEXT TO THE STREET RIGHT-OF- WAY, THE LATERAL SHALL TERMINATE 3 FEET INSIDE THE LOT AS MEASURED FROM THE UTILITY EASEMENT. 30. THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE CURB AT THE LOCATION OF THE SEWER LATERAL. 31. IF SEWER CONSTRUCTION IS TO BE DONE IN PHASES, THE CONTRACTOR SHALL PROVIDE A TERMINAL CLEANOUT AT THE PHASE BOUNDARY, NOT MORE THAN 150 FEET FROM THE DOWNSTREAM MANHOLE, SEE CITY OF FONTANA STANDARD DETAIL FOR TERMINAL CLEANOUT. 32. ALL 4" HOUSE LATERALS SHALL BE INSTALLED AT A 2% MINIMUM GRADE UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER. 33. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS. 34. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES. 35. SHORT V.C.P. STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED AT MANHOLE WALLS TO ALLOW FOR MINOR DEFLECTIONS IN ALIGNMENT. 36. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS, AND PROCEDURES DESCRIBED IN THE "W.A.T.C.H. MANUAL", LATEST EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. 37. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER. 38. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES. 39. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE CITY ENGINEER. RFRACT MAP, H(Do 16074 SEWER IMPROVEMENT PLANS FUTURE TRACT 16074 DEVELOPMENT 385 SHEET 20 384 PROPOSED SCHOOL 41 MH # 40 W W 2 1 E•��;3 SEWER .j 16232 31 *' . 16,937 L.F. p0 INSTALL 4' SEWER LATERAL & RESIDENTIAL � 384 EA. 33 INSTALL 48' I.D. MANHOLE (C❑F-112) 25 W KIM 26 31 & 114) Y EA, 35 N �1 I� �� 11111 MODIFIED WYE PER DETAIL ON THIS SHEET 1 I■/� 30 INSTALL i■ SHEET 15 EA. 39 28 29 -s 4 EA, 40 INSTALL �® 2 EA. 25 32 W OF U.P.C. 12 �II,N� 42 REMOVE EXISTING BACK WATER VALVE �11.■ I EA. 43 I I■1 4 EA, • �• ,■1 '� .. 111 �` 11 !. j • 11 I I■ i�! 1 j■1 �G■ liE■f 11�■1 SHEET 20 384 PROPOSED SCHOOL 41 MH # 40 W W 2 1 E•��;3 SEWER O 31 *' V 16,937 L.F. p0 INSTALL 4' SEWER LATERAL & RESIDENTIAL � 384 EA. 33 INSTALL 48' I.D. MANHOLE (C❑F-112) 25 W KIM 26 31 & 114) Y EA, 35 N V CLEAN-OUT WITH MODIFIED WYE PER DETAIL ON THIS SHEET 64 27 30 INSTALL 48' I.D. MANHOLE PER DETAIL THIS SHEET 15 EA. 39 28 29 -s SHEET 20 384 PROPOSED SCHOOL 41 MH # 40 W W 2 1 E•��;3 ENGINEER'S NOTICE TO CONTRACTORS THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY SEARCH OF AVAILABLE RECORDS AND TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THIS PLAN. THE CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN, AND ANY OTHER LINES OR STRUCTURES NOT SHOWN ON THESE PLANS, AND IS RESPONSIBLE FOR PROTECTION OF AND ANY DAMAGE TO THESE LINES OR STRUCTURES. CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTORS WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT. INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO, DEFEND, INDEMNIFY, AND HOLD DESIGN PROFESSIONAL AND OWNER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE TO REPORT DISCREPANCIES IN PLANS AND/OR FIELD CONDITIONS IMMEDIATELY TO THE DESIGN ENGINEER FOR RESOLUTION PRIOR TO CONSTRUCTION, AND SHALL BE RESPONSIBLE FOR DISCREPANCIES NOT SO REPORTED AND RESOLVED. CAUTION: THE ENGINEER PREPARING THESE PLANS WILL NOT RESPONSIBLE FOR, OR LIABLE FOR, UNAUTHORIZED CHANGES OR USES OF THESE PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND MUST BE APPROVED BY THE PREP,ARER OF THESE "PLANS". r� v CONSTRUCTION NOTES & QUANTITY ESTIMATE SEWER LEGEND .. - (EX. 8" S Y EXISTING OR PROPOSED BY OTHERS SEWER'MAIN NEW SEWER MAIN PROPOSED MANHOLE - 0 - - EXISTING OR PROPOSED BY OTHERS SEWER MANHOLE SERVICE LATERAL THIS LOT REQUIRES A MODIFIED WYE PER DETAIL ON THIS PAGE THIS LOT REQUIRES A BACKWATER VALVE PER SECT. 409 OF U.P.C. PROPOSED STORM DRAIN SEWER MAIN SEWER 31 INSTALL 8' EXTRA STRENGTH VCP SEWER LINE 16,937 L.F. 32 INSTALL 4' SEWER LATERAL & RESIDENTIAL CLEAN-OUT (C❑F 125) 384 EA. 33 INSTALL 48' I.D. MANHOLE (C❑F-112) 25 EA. KIM INSTALL 48' LD, CUL-DE-SAC MANHOLE (C❑F-112 & 114) 16 EA, 35 INSTALL 4' SEWER LATERAL & RESIDENTIAL CLEAN-OUT WITH MODIFIED WYE PER DETAIL ON THIS SHEET 64 EA. 37 INSTALL 48' I.D. MANHOLE PER DETAIL THIS SHEET 15 EA. 39 INSTALL 60' I.D. MANHOLE (C❑F-112) 4 EA, 40 INSTALL 72' I.D. MANHOLE (COF-112) 2 EA. 41 INSTALL BACK WATER VALVE PER SECT. 409 OF U.P.C. 12 EA. 42 REMOVE EXISTING BACK WATER VALVE 6 EA. 43 lif! BACK WATER VALVE, PROTECT IN PLACE 4 EA, I� �• ,■1 '� .. 111 �• • i�! �G■ liE■f 11�■1 rI■ ®� 111■1 �� Til 1 ;• �I�11m Nj ►1 ,� 1 rt �11 i m I�I OEM; ElmrxIm =al 11 ���, gCpm �l♦� ENGINEER'S NOTICE TO CONTRACTORS THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY SEARCH OF AVAILABLE RECORDS AND TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THIS PLAN. THE CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN, AND ANY OTHER LINES OR STRUCTURES NOT SHOWN ON THESE PLANS, AND IS RESPONSIBLE FOR PROTECTION OF AND ANY DAMAGE TO THESE LINES OR STRUCTURES. CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTORS WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT. INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO, DEFEND, INDEMNIFY, AND HOLD DESIGN PROFESSIONAL AND OWNER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE TO REPORT DISCREPANCIES IN PLANS AND/OR FIELD CONDITIONS IMMEDIATELY TO THE DESIGN ENGINEER FOR RESOLUTION PRIOR TO CONSTRUCTION, AND SHALL BE RESPONSIBLE FOR DISCREPANCIES NOT SO REPORTED AND RESOLVED. CAUTION: THE ENGINEER PREPARING THESE PLANS WILL NOT RESPONSIBLE FOR, OR LIABLE FOR, UNAUTHORIZED CHANGES OR USES OF THESE PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND MUST BE APPROVED BY THE PREP,ARER OF THESE "PLANS". r� v CONSTRUCTION NOTES & QUANTITY ESTIMATE SEWER LEGEND .. - (EX. 8" S Y EXISTING OR PROPOSED BY OTHERS SEWER'MAIN NEW SEWER MAIN PROPOSED MANHOLE - 0 - - EXISTING OR PROPOSED BY OTHERS SEWER MANHOLE SERVICE LATERAL THIS LOT REQUIRES A MODIFIED WYE PER DETAIL ON THIS PAGE THIS LOT REQUIRES A BACKWATER VALVE PER SECT. 409 OF U.P.C. PROPOSED STORM DRAIN SEWER MAIN SEWER 31 INSTALL 8' EXTRA STRENGTH VCP SEWER LINE 16,937 L.F. 32 INSTALL 4' SEWER LATERAL & RESIDENTIAL CLEAN-OUT (C❑F 125) 384 EA. 33 INSTALL 48' I.D. MANHOLE (C❑F-112) 25 EA. 34 INSTALL 48' LD, CUL-DE-SAC MANHOLE (C❑F-112 & 114) 16 EA, 35 INSTALL 4' SEWER LATERAL & RESIDENTIAL CLEAN-OUT WITH MODIFIED WYE PER DETAIL ON THIS SHEET 64 EA. 37 INSTALL 48' I.D. MANHOLE PER DETAIL THIS SHEET 15 EA. 39 INSTALL 60' I.D. MANHOLE (C❑F-112) 4 EA, 40 INSTALL 72' I.D. MANHOLE (COF-112) 2 EA. 41 INSTALL BACK WATER VALVE PER SECT. 409 OF U.P.C. 12 EA. 42 REMOVE EXISTING BACK WATER VALVE 6 EA. 43 EXISTING BACK WATER VALVE, PROTECT IN PLACE 4 EA, 1 rt �11 i ElmrxIm =al 11 ���, gCpm �l♦� ENGINEER'S NOTICE TO CONTRACTORS THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY SEARCH OF AVAILABLE RECORDS AND TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THIS PLAN. THE CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN, AND ANY OTHER LINES OR STRUCTURES NOT SHOWN ON THESE PLANS, AND IS RESPONSIBLE FOR PROTECTION OF AND ANY DAMAGE TO THESE LINES OR STRUCTURES. CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTORS WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT. INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO, DEFEND, INDEMNIFY, AND HOLD DESIGN PROFESSIONAL AND OWNER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE TO REPORT DISCREPANCIES IN PLANS AND/OR FIELD CONDITIONS IMMEDIATELY TO THE DESIGN ENGINEER FOR RESOLUTION PRIOR TO CONSTRUCTION, AND SHALL BE RESPONSIBLE FOR DISCREPANCIES NOT SO REPORTED AND RESOLVED. CAUTION: THE ENGINEER PREPARING THESE PLANS WILL NOT RESPONSIBLE FOR, OR LIABLE FOR, UNAUTHORIZED CHANGES OR USES OF THESE PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND MUST BE APPROVED BY THE PREP,ARER OF THESE "PLANS". r� v CONSTRUCTION NOTES & QUANTITY ESTIMATE SEWER LEGEND .. - (EX. 8" S Y EXISTING OR PROPOSED BY OTHERS SEWER'MAIN NEW SEWER MAIN PROPOSED MANHOLE - 0 - - EXISTING OR PROPOSED BY OTHERS SEWER MANHOLE SERVICE LATERAL THIS LOT REQUIRES A MODIFIED WYE PER DETAIL ON THIS PAGE THIS LOT REQUIRES A BACKWATER VALVE PER SECT. 409 OF U.P.C. PROPOSED STORM DRAIN SEWER MAIN x�v SLOPE ® 2% MIN. aw cc ¢Z WW H wx z W aI a Q ccW U) FWY (10) MAYWOOD ST. JURUPA AVENUE SECT FORECAST HOMES VICINITY MAP NOT TO SCALE NOTES 1. SEWER LATERALS SHALL HAVE A MINIMUM SLOPE OF 2%. 2. PLUGS SHALL BE CEMENTED IN WITH CEMENT MORTAR, OR SHALL BE NEOPRENE STOPPER OF APPROVED EQUAL. 3. 2' WIDE METALLIC DETECTABLE LOCATOR TAPE SHALL BE PLACED APPROXIMATELY 6' ABOVE EACH LATERAL, BUT NOT GREATER THAN 6' DEEP, UNLESS OTHERWISE DIRECTED BY THE ENGINEER. FLAT WYE DETAIL NOT TO SCALE R/W TYPICAL LOT CONSTRUCT 48' I.D. MANHOLE PER C.O.F. STD. 112 MODIFIED PER NOTE BELOW IR . OESS/pN� C. 1 I y C m C No.63494 Exp. Sept. 30, 2006 CIVIL 4 9TFOF CA RECO 1 I eo ~ NOTE: ENGINEER: SEWER MAINS ARE TO BE LAID THRU THE MANHOLE AND USED AS A FORM FOR (SIGNATURE) (DAM THE INVERT, THE TOP � DIAMETER OF THE PIPE IS TO BE BROKEN OUT TO A NEAT LINE. BROKEN EDGES SHALL BE PLASTERED SMOOTH WITH Q30T MORTAR. (MODIFIED MANHOLE C.O.F. STD. 112) 48" I.D. MANHOLE DETAIL NOT TO SCALE E 0 - CIA N N 0 0 3 0 0 0 U) Ln r - co w 3 w LoJ CD co O O Q I- Q D SEWER 31 INSTALL 8' EXTRA STRENGTH VCP SEWER LINE 16,937 L.F. 32 INSTALL 4' SEWER LATERAL & RESIDENTIAL CLEAN-OUT (C❑F 125) 384 EA. 33 INSTALL 48' I.D. MANHOLE (C❑F-112) 25 EA. 34 INSTALL 48' LD, CUL-DE-SAC MANHOLE (C❑F-112 & 114) 16 EA, 35 INSTALL 4' SEWER LATERAL & RESIDENTIAL CLEAN-OUT WITH MODIFIED WYE PER DETAIL ON THIS SHEET 64 EA. 37 INSTALL 48' I.D. MANHOLE PER DETAIL THIS SHEET 15 EA. 39 INSTALL 60' I.D. MANHOLE (C❑F-112) 4 EA, 40 INSTALL 72' I.D. MANHOLE (COF-112) 2 EA. 41 INSTALL BACK WATER VALVE PER SECT. 409 OF U.P.C. 12 EA. 42 REMOVE EXISTING BACK WATER VALVE 6 EA. 43 EXISTING BACK WATER VALVE, PROTECT IN PLACE 4 EA, x�v SLOPE ® 2% MIN. aw cc ¢Z WW H wx z W aI a Q ccW U) FWY (10) MAYWOOD ST. JURUPA AVENUE SECT FORECAST HOMES VICINITY MAP NOT TO SCALE NOTES 1. SEWER LATERALS SHALL HAVE A MINIMUM SLOPE OF 2%. 2. PLUGS SHALL BE CEMENTED IN WITH CEMENT MORTAR, OR SHALL BE NEOPRENE STOPPER OF APPROVED EQUAL. 3. 2' WIDE METALLIC DETECTABLE LOCATOR TAPE SHALL BE PLACED APPROXIMATELY 6' ABOVE EACH LATERAL, BUT NOT GREATER THAN 6' DEEP, UNLESS OTHERWISE DIRECTED BY THE ENGINEER. FLAT WYE DETAIL NOT TO SCALE R/W TYPICAL LOT CONSTRUCT 48' I.D. MANHOLE PER C.O.F. STD. 112 MODIFIED PER NOTE BELOW IR . OESS/pN� C. 1 I y C m C No.63494 Exp. Sept. 30, 2006 CIVIL 4 9TFOF CA RECO 1 I eo ~ NOTE: ENGINEER: SEWER MAINS ARE TO BE LAID THRU THE MANHOLE AND USED AS A FORM FOR (SIGNATURE) (DAM THE INVERT, THE TOP � DIAMETER OF THE PIPE IS TO BE BROKEN OUT TO A NEAT LINE. BROKEN EDGES SHALL BE PLASTERED SMOOTH WITH Q30T MORTAR. (MODIFIED MANHOLE C.O.F. STD. 112) 48" I.D. MANHOLE DETAIL NOT TO SCALE E 0 - CIA N N 0 0 3 0 0 0 U) Ln r - co w 3 w LoJ CD co O O Q I- Q D