Loading...
HomeMy WebLinkAbout2896-14PRESSURE LOSS CALCULATION POINT OF CONNECTION "A" LOW PROJECT: SUMMIT HEIGHTS BY: CITY OF FONTANA, CALIFORNIA JRB/LML 1 STATIC PRESSURE HIGH: 101 ppsi LOW: 91 psi POINT OF CONNECTION "B" LOW SOURCE OF INFORMATION: . MAURICIO GUARDADO - SGVW - SGVW SUPPLIER: SAN GABRIEL VALLEY WATER DISTRICT SUPPLIER: SAN GABRIEL VALLEY WATER DISTRICT STATIC PRESSURE HIGH: 85 psi LOW- 77 psi PHONE NUMBER: (626) 448-6183 PHONE NUMBER: (626) 448-6183 STANDARDS IN EFFECT. SOURCE OF INFORMATION: MAURICIO GUARDADO - SGVW VALVE STATION/GPM: STATION: A-3 GPM: 41 P.S.I. LOSS. ITEM: FLOW METER 1-1 /4" @ 41 GPM 2.22 MASTER VALVE 1-1 /2" @ 41 GPM 1,80 WATER METER SIZE: 2" @ 41 GPM 1.40 BACKFLOW DEVICE SIZE: 2" @ 41 GPM 12.00 GATE VALVE(S): 1 3" @ 41 GPM 1.00 MAINLINE (CL.315): 3" 1250 L.F. @ 41 GPM 2.38 AUTOMATIC VALVE SIZE: 1-1/2" @ 41 GPM 1.70 LATERAL LINE SIZE 3/4" 110 L.F. @ 8 GPM 5.65 1" 35 L.F. @ 14 GPM 1.18 2" 6 L.F. @ 41 GPM 0.07 IRRIGATION HEAD PRESSURE: 46 GPM 30.00 SYSTEM LOSSES SUBTOTAL: SYSTEM LOSSES SUBTOTAL: 1" 35 L.F. @ 13 GPM 59.40 FITTING LOSSES (5% OF SUBTOTAL): FITTING LOSSES (5% OF SUBTOTAL): 2" 6 L.F. @ 47 GPM 2.97 ELEVATION LOSSES/GAINS (ELEV. x.433) t: ELEVATION LOSSES/GAINS (ELEV. x.433) t: IRRIGATION HEAD PRESSURE: -14.09 TOTAL SYSTEM LOSSES: TOTAL SYSTEM LOSSES: 48.28 AVAILABLE PRESSURE (LOW): AVAILABLE PRESSURE (LOW): SYSTEM LOSSES SUBTOTAL: 91.00 (-) DEFICIT OR (+) RESIDUAL PRESSURE: (-) DEFICIT OR (+) RESIDUAL PRESSURE: (+;42.72 SCALE: N.T.S. PRESSURE LOSS CALCULATION POINT OF CONNECTION "D" PROJECT: SUMMIT HEIGHTS BY: CITY OF FONTANA, CALIFORNIA JRB/LML 1 STATIC PRESSURE HIGH: 93 psi LOW: 84 psi POINT OF CONNECTION "B" LOW SOURCE OF INFORMATION: MAURICIO GUARDADO - SGVW - SGVW SUPPLIER: SAN GABRIEL VALLEY WATER DISTRICT SUPPLIER: SAN GABRIEL VALLEY WATER DISTRICT STATIC PRESSURE HIGH: 85 psi LOW- 77 psi PHONE NUMBER: (626) 448-6183 PHONE NUMBER: (626) 448-6183 STANDARDS IN EFFECT. SOURCE OF INFORMATION: MAURICIO GUARDADO - SGVW VALVE STATION/GPM: STATION: D-2 GPM: 46 P.S.I. LOSS: ITEM: FLOW METER 1-1/4" @ 46 GPM 2.80 MASTER VALVE 1-1/2" @ 46 GPM 2.27 WATER METER SIZE: 2" @ 46 GPM 1.60 BACKFLOW DEVICE SIZE: 2" @ 46 GPM 12.00 GATE VALVE(S): 1 3" @ 46 GPM 1.00 MAINLINE (CL.315): 3" 740 L.F. @ 46 GPM 1.78 AUTOMATIC VALVE SIZE: 1-1/2" @ 46 GPM 2.27 LATERAL LINE SIZE 3/4" 110 L.F. @ 8 GPM 5.65 1" 85 L.F. @ 14 GPM 2.86 1-1/4" 25 L.F. @ 21 GPM 0.68 2" 8 L.F. @ 46 GPM 0.11 IRRIGATION HEAD PRESSURE: SYSTEM LOSSES SUBTOTAL: 1" 35 L.F. @ 13 GPM 30.00 SYSTEM LOSSES SUBTOTAL: FITTING LOSSES (5% OF SUBTOTAL): 2" 6 L.F. @ 47 GPM 63.02 FITTING LOSSES (5% OF SUBTOTAL): ELEVATION LOSSES/GAINS (ELEV. x.433) t: IRRIGATION HEAD PRESSURE: 3.15 ELEVATION LOSSES/GAINS (ELEV. x.433)±: TOTAL SYSTEM LOSSES: - 3.76 TOTAL SYSTEM LOSSES: AVAILABLE PRESSURE (LOW): SYSTEM LOSSES SUBTOTAL: 62.41 AVAILABLE PRESSURE (LOW): (-) DEFICIT OR (+) RESIDUAL PRESSURE: 84.00 (-) DEFICIT OR (+) RESIDUAL PRESSURE: FITTING LOSSES (5% OF SUBTOTAL): (+;21.59 SCALE: N.T.S. SCALE: N.T.S. D SCALE: N.T.S. PRESSURE LOSS CALCULATION POINT OF CONNECTION "A" HIGH PROJECT: SUMMIT HEIGHTS BY: CITY OF FONTANA, CALIFORNIA JRB/LML 1 STATIC PRESSURE HIGH: 101 ppsi LOW: 91 psi POINT OF CONNECTION "B" LOW SOURCE OF INFORMATION: MAURICIO GUARDADO PROJECT: SUMMIT HEIGHTS BY: JRB/LML - SGVW PROJECT: SUMMIT HEIGHTS BY: JRB/LML SUPPLIER: SAN GABRIEL VALLEY WATER DISTRICT STATIC PRESSURE HIGH: 85 psi LOW- 77 psi DM. No.: 2896 PHONE NUMBER: (626) 448-6183 STANDARDS IN EFFECT. SOURCE OF INFORMATION: MAURICIO GUARDADO - SGVW VALVE STATION/GPM: STATION: A-21 GPM: 41 P.S.I. LOSS: ITEM: FLOW METER 1-1/4" @ 41 GPM 2.22 MASTER VALVE 1-1 /2" @ 41 GPM 1.80 WATER METER SIZE: 2" @ 41 GPM 1.40 BACKFLOW DEVICE SIZE: 2" @ 41 GPM 12.00 GATE VALVE(S): 1 3" @ 41 GPM 1.00 MAINLINE (CL.315): 3" 1085 L.F. @ 41 GPM 2.06 AUTOMATIC VALVE SIZE: 1-1/2" @ 41 GPM 1.70 LATERAL LINE SIZE 3/4" 90 L.F. @ 7 GPM 3.61 1" 130 L.F. @ 14 GPM 4.37 2" 3 L.F. @ 41 GPM 0.03 IRRIGATION HEAD PRESSURE: LATERAL LINE SIZE 3/4" 110 L.F. @ 8 GPM 5.91 30.00 SYSTEM LOSSES SUBTOTAL: 1" 35 L.F. @ 13 GPM 2.02 60.19 FITTING LOSSES (5% OF SUBTOTAL): 2" 6 L.F. @ 47 GPM 0.10 3.01 ELEVATION LOSSES/GAINS (ELEV. x.433) t: IRRIGATION HEAD PRESSURE: 30.00 7.40 TOTAL SYSTEM LOSSES: 0 U_ 70.60 AVAILABLE PRESSURE (LOW): SYSTEM LOSSES SUBTOTAL: 63.38 91.00 (-) DEFICIT OR (+) RESIDUAL PRESSURE: (+)20.40 9 SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. Q SCALE: N.T.S. PRESSURE LOSS CALCULATION CITY OF FONTANA, CALIFORNIA PRESSURE LOSS CALCULATION 1 POINT OF CONNECTION "B" HIGH 77 psi POINT OF CONNECTION "B" LOW SOURCE OF INFORMATION: MAURICIO GUARDADO PROJECT: SUMMIT HEIGHTS BY: JRB/LML - SGVW PROJECT: SUMMIT HEIGHTS BY: JRB/LML SUPPLIER: SAN GABRIEL VALLEY WATER DISTRICT STATIC PRESSURE HIGH: 85 psi LOW- 77 psi DM. No.: 2896 STATIC PRESSURE HIGH- 85 psi LOW' 77 psi STANDARDS IN EFFECT. SOURCE OF INFORMATION: MAURICIO GUARDADO - SGVW SOURCE OF INFORMATION: MAURICIO GUARDADO - SGVW 45 P.S.I.LOSS: SUPPLIER: SAN GABRIEL VALLEY WATER DISTRICT ITEM: FLOW METER 1-1 /4" @ SUPPLIER: SAN GABRIEL VALLEY WATER DISTRICT GPM PHONE NUMBER: (626) 448-6183 MASTER VALVE 1-1 /2" @ PHONE NUMBER: (626) 448-6183 GPM VALVE STATION/GPM: STATION: B-29 GPM: 19 WATER METER SIZE: 2" @ VALVE STATION/GPM: STATION: B-2 GPM: 47 ITEM: P.S.I. LOSS: ITEM' P.S.I. LOSS: FLOW METER 1-1 /4" @ 19 GPM 0.56 FLOW METER 1-1 /4" @ '47 GPM 1.92 MASTER VALVE 1-1 /2" @ 19 GPM 0.45 MASTER VALVE 1-1/2" @ 47 GPM 2.65 WATER METER SIZE: 2" @ 19 GPM 0.00 WATER METER SIZE: 2" @ 47 GPM 1.70 BACKFLOW DEVICE SIZE: 2" @ 19 GPM 12.00 BACKFLOW DEVICE SIZE: 2" @ 47 GPM 12.00 GATE VALVE(S): 1 3" @ 19 GPM 1.00 GATE VALVE(S)- 1 3" @ 47 GPM 1.00 MAINLINE (CL.315): 3" 1250 L.F. @ 19 GPM 0.54 MAINLINE (CL.315): 3" 1250 L.F. @ 47 GPM 3.43 AUTOMATIC VALVE SIZE: 1" @ 19 GPM 2.60 AUTOMATIC VALVE SIZE: 1-1/2" @ 47 GPM 2.65 LATERAL LINE SIZE 1" 160 L.F. @ 11 GPM 1.58 LATERAL LINE SIZE 3/4" 110 L.F. @ 8 GPM 5.91 1-1/4" 5 L.F. @ 19 GPM 0.10 1" 35 L.F. @ 13 GPM 2.02 IRRIGATION HEAD PRESSURE: 30.00 2" 6 L.F. @ 47 GPM 0.10 3.00 ELEVATION LOSSES/GAINS (ELEV. x.433) t: IRRIGATION HEAD PRESSURE: 30.00 SYSTEM LOSSES SUBTOTAL: 49.23 0 U_ 62.98 AVAILABLE PRESSURE (LOW): SYSTEM LOSSES SUBTOTAL: 63.38 FITTING LOSSES (5% OF SUBTOTAL): 2.46 ELEVATION LOSSES/GAINS (ELEV. x.433) t: +11.49 FITTING LOSSES (5% OF SUBTOTAL): 3.17 ELEVATION LOSSES/GAINS (ELEV, x.433) t: -12.24 TOTAL SYSTEM LOSSES: 63.18 AVAILABLE PRESSURE (LOW): 77.00 TOTAL SYSTEM LOSSES: 54.31 (-) DEFICIT OR (+) RESIDUAL PRESSURE: (+)13.42 AVAILABLE PRESSURE (LOW): 77.00 (-) DEFICIT OR (+) RESIDUAL PRESSURE: (+;22.69 SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. D SCALE: N.T.S. D - SCALE: N.T.S. 'EM& SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. PRESSURE LOSS CALCULATION POINT OF CONNECTION ficif PROJECT: SUMMIT HEIGHTS BY: CITY OF FONTANA, CALIFORNIA JRB/LML 1 STATIC PRESSURE HIGH: 85 psi LOW- 77 psi D j B BY. SOURCE OF INFORMATION: MAURICIO GUARDADO AS SHOWN - SGVW DATE: 8/30/99 SUPPLIER: SAN GABRIEL VALLEY WATER DISTRICT APPraov® BY: f'f► DATE: CRY ENGINEER RGE 25126 EXP. DATE 12/31/9 DM. No.: 2896 PHONE NUMBER: (626) 448-6183 STANDARDS IN EFFECT. VALVE STATION/GPM: STATION: C-14 LGPM: 45 P.S.I.LOSS: ITEM: FLOW METER 1-1 /4" @ 45 GPM 2.22 MASTER VALVE 1-1 /2" @ 45 GPM 2.18 WATER METER SIZE: 2" @ 45 GPM 1.55 BACKFLOW DEVICE SIZE: 2" @ 45 GPM 12.00 GATE VALVE(S): 1 3" @ 45 GPM 1.00 MAINLINE (CL.315): 3" 530 L.F. @ 45 GPM 1.27 AUTOMATIC VALVE SIZE: 1-1/2" @ 45 GPM 2.18 LATERAL LINE SIZE 3/4" 125 L.F. @ 11 GPM 6.43 1" 30 L.F. @ 45 GPM 1.01 2" 10 L.F. @ 45 GPM 0.14 IRRIGATION HEAD PRESSURE: 30.00 SYSTEM LOSSES SUBTOTAL: Q U 59.98 FITTING LOSSES (5% OF SUBTOTAL): co C c 3.00 ELEVATION LOSSES/GAINS (ELEV. x.433) t: C: 0.00 TOTAL SYSTEM LOSSES: 0 U_ 62.98 AVAILABLE PRESSURE (LOW): O 77.00 (-) DEFICIT OR (+) RESIDUAL PRESSURE: (+114.02 9 SCALE: N.T.S. SCALE. N.T.S. O SCALE: N.T.S. kTi SCALE: N.T.S. CITY OF FONTANA, CALIFORNIA SHOULD CONSTRUCTION OF THE REQUIRED 1 IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER THE CITY ENGINEER MAY REQUIRE ' REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND i . D j B BY. SUMMIT HEIGHTS TRACT. #E15839 15840 ' COMMUNITY FACILITIES DISTRICT AS SHOWN DESIQI� BY:. JRB DATE: 8/30/99 cHEa® BY: JAF APPraov® BY: f'f► DATE: CRY ENGINEER RGE 25126 EXP. DATE 12/31/9 DM. No.: 2896 14 19 STANDARDS IN EFFECT. kTi SCALE: N.T.S. LANDSCAPE a ARCHITECTURE SITE PLANNING 10630 Town Center Dr., Suite 128 Rancho Cucamonga, CA 91730 (909) 484-2800 Fax 1909) 4B4-2802 Richard Krumwiede CA Lic. #2834 AZ Lic. # 29115 NV Lic. # 446 �PNpSCAPF � Kw rUm% C* a 4rF OF C NO 1 IJ:1<�II11Mf1/'[llAla►��� 1 R11HIT1,RRA DESIGN GROUP' U C LANDSCAPE a ARCHITECTURE SITE PLANNING 10630 Town Center Dr., Suite 128 Rancho Cucamonga, CA 91730 (909) 484-2800 Fax 1909) 4B4-2802 Richard Krumwiede CA Lic. #2834 AZ Lic. # 29115 NV Lic. # 446 �PNpSCAPF � Kw rUm% C* a 4rF OF C NO 1 IJ:1<�II11Mf1/'[llAla►��� 1 U C CCT 'c 0 U 0 E o � 0 � 00 Tco L m 06 0 00 � i � o Y 0 � C: v E . i Q U co C c C: 0 U_ O U MREVISIONS' IDRAWNiW -DATE 8/30/99 AS SHOWN 95007-3