HomeMy WebLinkAbout2875-3Y
0
0
N
0
w
z
ui
v
0
4,
0
E:
1'7
19 20 21
•- •
LOT NO.
DESIGN STA.
"AS—BUILT" STA.
LOT NO.
DESIGN STA.
"AS—BUILT" STA.
7
16+94
( f y4
16
20+61
20-f6 l
8
17+46
14 Iro
17
20+56
f 5 6
9
17+91
/ f
18
20+46
f
10
18+46
4 !0
19
19+93
11
18+96
20
19+41
/
12
19+46
46
21
19+00
O
13
19+90
O
22
18+41
14
20+31 1
40 1
23
17+96
6
15
20+51
24
17+41
Undergrand Service Alert
C= Y CO TOLL FTSE
t—wo
227-2600
TWO WORKING DAYS BEFORE YOU DIG
SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS
NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF
APPROVAL SHOWN HEREON AND CARRIED FORTH IN A
DILIGENT MANNER THE CITY ENGINEER MAY REQUIRE
REVISIONS TO THE PLANS TO BRING THEM INTO
CONFORMANCE WITH CONDITIONS AND STANDARDS
IN EFFECT.
BIRCH TREE PLACE
PLANS PREPARED FOR
CENTEX HOMES
2280 WARDLOW CIRCLE
SUITE 150
CORONA, CA. 92880
(909) 279-4000
0
13+37.00 BIRCH PLACE LACE
E
9+95.00
CL MH NO #4
/Z\ • +:D DOCUMENT
These Record Documents have been prepared
based on information provided by others. The
Design Professional has not verified the accuracy
and/or completeness of this information and shall
not be responsible for any -errors or omissions
which may be incorporated herein as a result
-rp
.�-
DATE
10
BIRCH TREE PLACE
SEE SHT 2
50'
25' 25'
3 '
18' . 18'
lei
12
MAGNOLIA PLACE
SEE SHT 4
50'
25' 25'
3 '
18 18'
I
I I
31 32
\------------ --U�
W w" w w w w—
O
— � — .0U)N N 0 11— 252.00 — — 112
N oN N90'00'00"E A
I �
i
7
I � I
18 18
36'
25' 25'
50'
BIRCH TREE PLACE
FUTURE
Engineer City BENCHMARK
Apf5roval D. D.
IW&M0 =,L-to',#1536697E AT SOUTH WEST CORNER OF
.�.�[B.M. #361, SPIKE IN NORTH FACE OF P.P-.
BASELINE AVENUE AND SULTANA AVENUE.ELEVATK)N: 1365.01
---�
If3
PROFILE
HORIZ: 1"= 40'
VERT: 1 "= 4'
GRAPHIC SCALE
40 0 20 40 80 160
I
51 61
'o
I,I I cop) I
� o
Z I I 12+52.00 CANDLEWOOD WAY
13+37.00 MAGNOLIA PLACE
3 I I 62
i 12+47.00
CL MH NO #8
------
I M
8 21 I I
III ( I I
18' 18
36'
25' 25'
50'
MAGNOLIA PLACE
FUTURE
CANDLEWOOD WAY
M
(INFM)
1 inch = 40 ft
CONSTRUCTION NOTES
__ CONSTRUCT 48" PRECAST CONCRETE MANHOLE PER CITY STD. DWG. NO. 112
CONST. 4" VCP SEWER LATERAL & CLEANOUT PER CITY STD DWG NO 125
(SEE GENERAL NOTE N0. 30)
CONSTRUCT 8" VCP EXTRA STRENGTH SEWER MAIN
INSTALL BACKFLOW CHECK VALVE
Prepared By: I? N" CITY OF FONTANA, CALIFORNIA
ALLARD ENGINEERING ��451) J. q<<<<C, SEWER IMPROVEMENT PLANS
Civil Engineering - Land Surveying - land Planning 0� Q
8253 Sierra Avenue � p — Drawn By: TRACT 16085-1 Scale:
No. 36052 m DEA/WF/JK 1 "= 40'
Fontana, California 92335 W m PH�►SE
909) 356-1815 Fax (909) 356-1795 a= Exp. 6/30/2004 Designed By:TRE CE Date:
1,§ %- CIVO- �`P WF/JF DLEW AY MAY, 2001
Aa and J. Allard, A.C.E. 36052 Date F CF CAS-\F� Checked By: Approve Dwg. No. �Z8 (expires 6/30!2004) DH RC -r C ENGINEER R.C.E. 51152 2875
Filename: M:\DWG\12704\PHASE-1\SEWER\SWR-3.DWG