GENERAL NOTES:
CITY OF FONTANA UTILITY
1 ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA
CITY OF FONTANA
STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS
ATTN: CARLOS NAVARRO
FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK").
8353 SIERRA AVENUE
2 CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA ENGINEERING
FONTANA, CA 92335
DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE
(909) 350-6632
REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC
SO. CALIFORNIA GAS COMPANY
RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610.
ATTN: ALAN KESELOFF
3 THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES.
16231 VALLEY BLVD.
CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE
FONTANA, CA 92335
OPERATION AND WATER REQUIREMENTS.
(909) 335-7781
4 STATIONING REFERS TO THE CENTERLINE OF SEWER EXCEPT WHERE OTHERWISE NOTED.
EMERGENCIES: (800) 427-2200
5 ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR
SO. CALIFORNIA EDISON COMPANY
TO PAVING OF STREETS.
ATTN: JAIME AMESZCUA
6 THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE
(909) 357-6581
INFORMATION. HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR
7951 REDWOOD AVENUE
TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING
FONTANA, CA 92335
UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO.
(909) 820-5598 — UNDERGROUND
THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-422-4133
(909) 820-5137 — TRANSMISSIONS
TWO WORKING DAYS BEFORE EXCAVATION.
(213) 637-1233 — PIPELINES
7 ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED
(909) 357-6589 — DISTRIBUTION
TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING.
(800) 422-4133
8 THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES
CRAWFORD CANYON MUTUAL WATER CO.
INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION,
ATTN: BILL VANORKIEFT, JR.
LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER,
(619) 868-6040
STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE
GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES.
9 AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF
RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER.
10 WHEN CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT
BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK",
THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER
FOR RESOLUTION.
11 APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT.
12 ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH
TO MATCH EXISTING CONCRETE.
13 NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN
PLACED, INSPECTED AND APPROVED.
14 THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH
SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS
PURSUANT TO THE REQUIREMENTS
15 THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK
FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION
OF INDUSTRIAL SAFETY.
16 NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
17 THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS
TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT-OF-WAY
DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL.
18 IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES,
DELINEATORS OR OTHER TRAFFIC CONTROL AT ALL TIMES.
19 A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE
TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION
OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED.
20 ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER.
21 ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE
THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL
BE RESPONSIBLE FOR THE'PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL G'
NAT
STAKING DURING CONSTRUCTION. COM
22 CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING
STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE.
TEMPORARY NON—ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS.
23 IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED
IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED
AGENCIES IMMEDIATELY.
24 THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT
TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER.
25 REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY
MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED
CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE
DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR
SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS
CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT.
26 THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL
TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CLOSURE
AREA FOR RESIDENTS AND EMERGENCY VEHICLES.
27 NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT—OF—WAY WITHOUT
PRIOR APPROVAL OF THE INSPECTOR.
28 SANITARY SEWER LINES SHALL BE CONSTRUCTED OF BELL AND SPIGOT TYPE VITRIFIED
CLAY PIPE (V.C.P.) EXTRA STRENGTH CLASS AND SHALL CONFORM TO THE PROVISIONS
OF THE ASTM DESIGNATION C700 FOR V.C.P..
29 TERMINATE ALL 4 HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH A PLUG 12"
BELOW THE GROUND SURFACE. WHEN PUBLIC UTILITY EASEMENTS EXIST NEXT TO THE
STREET RIGHT—OF—WAY, THE LATERAL SHALL TERMINATE 3 FEET INSIDE THE LOT AS
MEASURED FROM THE UTILITY EASEMENT.
30 THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE CURB AT THE
LOCATION OF THE SEWER LATERAL. P
31 IF SEWER CONSTRUCTION IS TO BE DONE IN PHASES, THE CONTRACTOR SHALL PROVIDE TH
A TERMINAL CLEANOUT AT THE PHASE BOUNDARY, NOT MORE THAN 150 FEET FROM THE SH
DOWN STREAM MANHOLE, SEE CITY OF FONTANA STANDARD DETAIL FOR TERMINAL CLEANOUT. TO
TH
32 ALL 4 HOUSE LATERALS SHALL BE INSTALLED AT A 2% MINIMUM GRADE UNLESS OTHERWISE PR
APPROVED BY THE CITY ENGINEER. DR
SI
33 PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND SH
VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS
TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS TH
SHOWN ON THE PLANS. IB
OF
34 THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, TH
INCLUDING ADEQUATE WATERING, AT ALL TIMES. AN
AN
35 SHORT VCP STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED AT MANHOLE IN
WALLS TO ALLOW FOR MINOR DEFLECTIONS IN ALIGNMENT. FO
EN
36 THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS
AND PROCEDURES DESCRIBED IN THE "W.A.T.C.H. MANUAL", LATEST EDITION UNLESS CO
OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. AL
37 UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING,
STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION
OF THE CITY TRAFFIC,ENGINEER.
38 NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL
OF THE CITY ENGINEER.
.A
UNDERGROUND SERVICE ALERT
(800) 227-2600
3' MAX 51ZE NATIVE
SOL COMPACTED 952
G• MN. G` MIN
1
IIX.
I III
MAX. SIZE 1• MAX. SIZE
VE SOIL I SELECTED NATIVE
PAGTED 90Z BEDDING COMPACTED
TO 90%
TABLE- 200-1.2 CA3
51EVE 512C
CITY OF FONTANA UTILITY
NOTIFICATION LIST
CITY OF FONTANA
PACIFIC BELL CO.,
ATTN: CARLOS NAVARRO
ATTN: VIRGINIA BECKER
8353 SIERRA AVENUE
3939 E. CORONADO STREET
FONTANA, CA 92335
ANAHEIM, CA 92807
(909) 350-6632
(714) 666-5467
SO. CALIFORNIA GAS COMPANY
COMCAST (CABLE TV)
ATTN: ALAN KESELOFF
ATTN: JACK HAYES
16231 VALLEY BLVD.
1205 DUPONT AVENUE
FONTANA, CA 92335
ONTARIO, CA 91761
(909) 335-7781
(909) 390-4777 X 3055
EMERGENCIES: (800) 427-2200
SO. CALIFORNIA EDISON COMPANY
GENERAL TELEPHONE COMPANY
ATTN: JAIME AMESZCUA
ATTN: STEVE HOCK
(909) 357-6581
1400 E. PHILLIPS BLVD.
7951 REDWOOD AVENUE
ONTARIO, CA 91766
FONTANA, CA 92335
(800) 422-4133
(909) 820-5598 — UNDERGROUND
(909) 820-5137 — TRANSMISSIONS
(213) 637-1233 — PIPELINES
(909) 357-6589 — DISTRIBUTION
(800) 422-4133
CRAWFORD CANYON MUTUAL WATER CO.
FONTANA WATER COMPANY
ATTN: BILL VANORKIEFT, JR.
ATTN: AL KROHN
(619) 868-6040
8440 NUEVO AVENUE
FONTANA, CA 92335
(909) 822-2201 X 323
FAX: (909) 823-5046
UNDERGROUND SERVICE ALERT
(800) 227-2600
3' MAX 51ZE NATIVE
SOL COMPACTED 952
G• MN. G` MIN
1
IIX.
I III
MAX. SIZE 1• MAX. SIZE
VE SOIL I SELECTED NATIVE
PAGTED 90Z BEDDING COMPACTED
TO 90%
TABLE- 200-1.2 CA3
51EVE 512C
I PERCENTAGE
PASSING 54EVES
/100
/a
70 -GO
N9/1'
0-15
A5TM G 131
TEST GRADING
•rir
8• VCP
III_
TYPICAL BEDDING FOR 5* VCP
LESS THAN 10' DEEP
N.T.S.
t
•g'
3' MAX SIZE NATIVE
SOIL COMPACTED 957.
G' MN. G'
III=11I1I a — — - 11 l�
SAN GABRIEL MOUNTAINS
VICINITY MAP
cn
Q
H
U
w
4�
G' MAX. SIZE 1' MAX. SIZE 1
NATIVE 50L I SELECTED NATIVE
COMPACTED 902 BEDDING COMPACTED
TO CIOZ
NORTH FRONTAGE_ ROAD
I
a• VCP i
III_I F1
1/2' CRUSHED STONE BEDDING
PER STD. SPECS. FOR PUBLIC I J J
WORKS CONSTRUCTION TABLE
200 1.2 CA3 SHOWN
TYPICAL BEDDING FOR 8•. VCP
10" OR DEEPER
N.T.S.
RIVATE ENGINEER'S NOTICE TO CONTRACTORS
E EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES
OWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS:
THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT
OSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE
ECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE
AWINGS. THE CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND RESPON
BILITY FOR THE UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN OR NOT
OWN ON THESE DRAWINGS.
E CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONS—
ILITY FOR THE JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION
THIS PROJECT; INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT
IS SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS;
D THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE OWNER
D THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED,
CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING
R LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE
GINEER.
NTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL, REPORT
L DISCREPANCIES TO THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK.;
4 ,
Underground Service Alert
CALL
TOLL FREE
1-800
227-2600
TWO WORKING DAYS BEFORE YOU DIG
PLANS PREPARED FOR:
KAUFMAN do BROAD
ATTN: MR. TIM JONES
801 CORPORATE CENTER, DR.
SUITE 201
POMONA, CA. 91768-2641
PHONE: (909) 802-1100
INDEX MAP
CONSTRUCTION NOTES:
QUANTITIES
O INSTALL 8 V.C.P., EX
TRA STRENGTH, SEWER 1 Co 4 4" ' L. F
O CONSTRUCT PRECAST CONCRETE MANHOLE PER,CITY OF FONTANA 8 E.A.
STD. DWG. NO. 112 (I .,D . = 48")
O INSTALL 4" V.C.P. SEWER LATERAL PER CITY OF FONTANA 17 S
STD. DWG. NO. 125
O4 REMOVE 8" V.C.P. PLUG J f A.
B t?r E":,0,
.. �
RECORD DRAWING
THESE HAVE BEEN PREPARED. IN. 0, 62:18 cl, rl � ba
PRRT, ON THF: 6A.6;3 OF INFORMATION COMPILED 0!0
FUDR 41SH_HE ENGINEER WILL NOt 8E
D HY O HER3. , ...,. /
t 4
HESPONS iLE FOR ANY ERRORS OR , L L
HAVE BEEN INCORPORATED INTO?fEDOCtNEIT$118 y
,SULTTHEREC C',R`. X03' BENCH MARK: #R-17 CALTRANS BASIS "OF= -BEARINGS:
CITY
CALIFORNIA HE BAS F B AKIN SFR TH S MAP O.F'FONTANA,,.
T IIgg E I
@RARS CAP IN GQNCfJRTE R.C.E. IS THE SOU�H LINE OE THE NORTHEAST
TI OW MM LEG 34 N// HI HLAND QUARTER OF SECTIO 6 TO NSHIP i PUBLIC
WORKS
DEPARTMENT
g AV b.20 MI. W���0 SAN NORTH RANGE 6 WEST SI�Ngg B�N66I►RDINO tLJ 1 l`�J
HIGHLAND AVVE., FROMMSIERRALAVE. ME AIMAPNFILEDNINSBOOK988�PAGESW36
C� 6 ' ' 1428.6090 RECORDS OF 'SANG BERNARD OF SURVEY
CUOUNT, • DRAWN BY: SCALE: -
ELEVATION:
Y'
PREPARED IN THE OFFICE OF TRACT NO .15840
SI
MADOLE AND ASSOCIATES, INC. QuoZ�T��F DESIGNED: AS SHOWN
OF THE INLAND EMPIRE y 5,� MCA
SEWER IMPROVEMENT�PLANS
10601 CHURCH STREET 'STE . 107 WINO . 14814 9 CHECKED: TITLE SHEET DATE:
RANCHO CUCAMONGA, -CA 91730 MLS
PHONE (909) 948-1311 Exp: 3-31-01
OB NO. ,` DWG NO. SHEET NO
sr�l CIVIC- - cl/,
E FOF CAIZF� 126—Lj APP OVED 2796 1OF 4,
RE V I S I ONS APPROVAL DATE APPROVAL DATE MADOLE R . C . E . 14814 DATE CITY ENGINEER R.C.E. 25126
*P* SEEWA PLAN TITLE SHEET 15840 - 24 [0. 1471 PF: 15840 764 07 -Jul -99 06: 08 AN 1 126-464-4