HomeMy WebLinkAbout2269-PE-0006POLE 4' PROJECTION #6 GROUND WIRE TO LIGHT POLE GROUND LUG. BASE COVER — o ' - f- GROUND CLAMP v (SEE NOTE #6) GROUT 97 1. 0II I 4 ANCHOR BOLTS " DIA. X 36 X 4'- Q_ I I 1 ( i ( I ) Ii 8 NUTS AND FLAT WASHERS POWER CIRCUIT, SEE PLAN • Q • Q•. •- a. I I L I I I I I t>GRADE ti-- a I i I" DIA II _ Q I 1 4' SO. WEATHERPROOF BOX (FOR CCTV) ANCHOR BOLTS I I 1 1 11 I 4' SO. WEATHERPROOF WITH BARRIER AND GASKETED COVER Q . I I 1 ( I ( I �11 011,_� BOX WITH GASKETED �.,�,) I I Li COVER COVER FOR PA k LL 12' PIGTAIL POWER CIRCUIT 1 SEE PLAN FOR SIZE (( I I v 1 11 10 RACEWAYS PULL CORD —�/z' HOLE WITH GROMMET CL ij PULL CORD \\ // \\ / p MOUNT 12' ABOVE TOP OF RACEWAY PLATFORM (TYP.) DETAIL An - a ° SCALE: 3' FOUNDATION NOTES: POWER CIRCUIT. SEE PLAN I. CONCRETE SHALL BE CLASS 560-C-3250 WITH A 12_#5 a. a MAXIMUM SLUMP OF 4 INCHES AND CURED FOR VERTICAL BARS TEN DAYS BEFORE THE LIGHT STANDARD IS ERECTED. FLEXIBLE METAL CONDUIT WITH PULL CORD, INSTALL INSIDE POLE (CCTV) -� #4 SPIRAL THREE 2. RACEWAY TRENCH SHALL BE BACKFILLED AND FiRMLY � — EXTRA TURNS. COMPACTED BEFORE THE LIGHT STANDARD IS ERECTED., TOP A BOTTOM (NOTE 3> ., i/2' FLEXIBLE METAL CONDUIT WITH PULL CORD, INSTALL INSIDE POLE (PA) 3. USE #4 SPIRAL AT 6" PITCH OR SUBSTITUTE #4 TIES AT 6' ON CENTER. 44 TIES SHALL HAVE 1 ' -6 LAP. A A 4. EXCAVATION FOR FOUNDATION SHALL BE MADE WITH AN AUGER OF THE SAME DIAMETER AS THE FOUNDATION. SOIL SURROUNDING THE FOUNDATION SHALL REMAIN = IN ITS UNDISTURBED STATE. HANDHOLE 5. THE ANCHOR BOLTS SHALL BE PROPERLY SECURED IN PARK I NG LOT AND STREET PLACE, USING FACTORY SUPPLIED TEMPLATE. LIGHTING STANDARD FOUNDATION DETAIL ELECTRICAL RACEWAY, SEE 6. PROVIDE GROUND CLAMP AND SECURE TO VERTICAL BAR OF PLAN FOR CONTINUATION SCALE: NONE THE REBAR CAGE WITH #6 GROUND WIRE PIGTAIL TO LIGHT POLE GROUND LUG. LIGHT POLE FOUNDATION PA CCTV P 12' MAXIMUM WIDTH EXCEPT AS APPROVED .BY THE CONSTRUCTION MANAGER RACEWAY WIRING I N LIGHT POLESPLATFORM (TYP) J CLU / Z� < o+ WARNING TAPE AS SPECIFIED _ z Q M N M M 000RACEWAY AND WIRING AS PER 0 PLANS, COMPLETE WITH TOP V I EW�' may/ GROUND* INSULATED EOU i PMENT SECTION A -A ///� u D WIRE. LIGHTING STANDARD FOUNDATION SCALE : i"=1,_O" SCALE 1 . =1 , -O. Z w TYPICAL WIRING IN TRENCH DETAIL YZF - CcLLI 0 J I' SCALE: NONE J U N _ I r � Z Z cL w Cr O - U Q Q Z - Cr v Z cn Ow CITY OF FONTANA,' CALIFORNIA U o CHECKED BYo, uJ M 'fC.• APPROVED, �'°= ,. .K•c.�; �+�"° °� '`;. OR. N0. DATE, CITY ENGINEER RE. Z w Information confidential DESIGNED BY _ , -— a J l plans, drawings, ngs, spec i f l SOUTHERN CONTRACT' N0. R. SLAY Q U HERN CALIFORNIA REGIONAL RAIL AUTHORITY C6320 cations. and or information COFAt LITER RAIL SAN BERNARDINO LINE furnished herewith sha I i DRAWN BY DRAWING NO. remain the property of the SCRRAProfessional Engineering Services an d staff Support forthe MetroiI nk Regional Rail System A. SHAMSABAD 16777 ORANGE E 111A i f ONTANA CALIFORNIA � Southern California Regional ! LO w Rail Authority and CHECKED BY PE 0006 ri PAR51:3i'�15 ®E L o w shall be held confident►aI: R. SLAY E INC. ®-dftLru&As" TREVISION 1TR.i ,I . - loa west walnut Street SKEET N0. and shall not be used for. .,. � eet . F- any purpose not provided APPROVED BY Pasadena California a 9 Ic4 ww for in agreements with the D. KRV F7 LIGHTING STANDARD DE:2 /6/93 ISSUED FOR BID TAILS California Regionai Rail Authority. DATE SCALE REV DATE. DESCRIPTION 1,!>SUB � .,�„ sue. APP. 7/6/93 APPROVED: RELEASED NONE