Loading...
HomeMy WebLinkAbout5132-6IRRIGATION NOTES METER AND BACKFLOW PREVENTION DEVICES WILL BE INSTALLED BY IRWD. SEE PLANS FOR SIZE, LOCATION AND WATER DEMAND. PRESSURE TESTING OF MAINLINE IS MANDATORY. SEE IRRIGATION SPECIFICATIONS IN THIS PACKAGE. AN INDIVIDUAL EMITTER IS TO BE PLACED AT EACH PLANT. EACH PLANTER SHALL RECEIVE EMITTERS WITH THE APPROPRIATE GALLONAGE PROVIDED. PROVISIONS FOR FUTURE EMITTERS AT THE DRIP LINE OF THE TREE SHALL BE PROVIDED FOR. ALL EMITTERS ARE TO BE ON SCHEDULE 80 RISERS WITH DOUBLE STREET ELLS. PRESSURE REDUCING DEVICES, FILTERS, AND END FLUSH VALVES ARE REQUIRED. IT IS THE INTENT OF THESE DRAWINGS TO INDICATE A COMPLETE AND OPERATIONAL IRRIGATION SYSTEM GIVING FULL COVERAGE AND READY FOR USE BY THE OWNER. THE DRAWINGS ARE BASED ON LANDSCAPE AND GRADING DRAWINGS IF EFFECT AT THE TIME THESE DRAWINGS WERE MADE. ANY DISCREPANCIES, OMISSIONS, ERRORS, ETC. ON THESE DRAWINGS OR ON THE SITE CHANGES, DO NOT AND SHALL NOT RELIEVE THE CONTRACTOR OF HIS RESPONSIBILITY TO PROVIDE A COMPLETE SYSTEM AS SHOWN. SHOULD THE CONTRACTOR REQUIRE TO MODIFY IN FIELD FROM PLAN DUE TO SITE CONDITIONS OR FOR OTHER FORESEEN DISCREPANCIES, HE MUST FIRST RESUBMIT TO CITY FOR CITY APPROVAL PRIOR TO COMMENCING CHANGE OF WORK. IRRIGATION CONTRACTOR SHALL VERIFY ALL PRESSURES ON SITE PRIOR TO CONSTRUCTION. LOCATE ALL VALVES IN PLANTING AREAS. IRRIGATION SYSTEM IS STRICTLY DIAGRAMMATIC, THEREFORE,CONTRACTOR MUST MAKE ADJUSTMENTS IN THE FILED TO INSURE ADEQUATE COVERAGE. IRRIGATION SYSTEM SHALL CONFORM TO STATE AND LOCAL CODES. THE SYSTEM SHALL BE FULLY GUARANTEED FOR A PERIOD OF ONE YEAR AFTER FINAL ACCEPTANCE. ANY DEFECTIVE MATERIAL OR POOR WORKMANSHIP SHALL BE REPLACED OR CORRECTED BY THE IRRIGATION CONTRACTOR AT NO COST TO THE OWNER. 120 VOLT ELECTRICAL POWER OUTLET FOR CONTROLLERS SHALL BE PROVIDED AS NOTED. IRRIGATION CONTRACTOR SHALL BE RESPONSIBLE FOR MAKING HOOK-UP FROM OUTLET TO CONTROLLER. ALL WIRE FROM CONTROLLER TO ELECTRIC CONTROL VALVES SHALL BE COPPER OF #14 600v DIRECT BURIAL. USE BLACK FOR PILOT, WHITE FOR COMMON, BLUE FOR EXTRA WIRE. INSTALL IN COMMON TRENCH WITH MAIN LINE PIPING WHERE POSSIBLE. LABEL EACH CONTROL WIRE AT THE CONTROLLER WITH THE STATION NUMBER. PROVIDE MINIMUM 18" COVER OVER ALL PRESSURE MAIN LINE PIPING, AND 12" OVER ALL NON -PRESSURE LATERAL LINE PIPING, OUTSIDE OF ROOTBALL. IRRIGATION CONTRACTOR SHALL INSTALL EMITTERS ON THE UP HILL SIDE ON BERMS AT EACH PLANT AND OUTSIDE OF ROOTBALL. DO NOT WILLFULLY INSTALL THE SYSTEM AS DESIGNED WHEN IT IS OBVIOUS IN THE FIELD THAT UNKNOWN OBSTRUCTIONS OR GRADE DIFFERENCES EXIST THAT WERE NOT KNOWN DURING DESIGNING. SUCH CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER'S AUTHORIZED REPRESENTATIVE; OTHERWISE THE IRRIGATION CONTRACTOR MUST ASSUME FULL RESPONSIBILITY FOR ANY AND ALL NECESSARY REVISIONS. CONTRACTOR SHALL PLACE FINAL LOCATION OF AUTOMATIC CONTROLLER AS SHOWN ON PLANS. IRRIGATION SYSTEM MUST BE PROGRAMMED TO OPERATE BETWEEN THE HOURS OF 10:00 P.M. AND 5:00 A.M. ONLY ALL LOCAL MUNICIPAL AND STATE LAWS, RULES AND REGULATIONS GOVERNING OR RELATING TO ANY PORTION OF THIS WORK ARE HEREBY INCORPORATED INTO AND MADE A PART OF THESE SPECIFICATIONS AND THEIR PROVISIONS SHALL BE CARRIED OUT BY THE CONTRACTOR. THE CONTRACTOR SHALL VERIFY THE LOCATIONS OF ALL EXISTING UTILITIES, STRUCTURES AND SERVICES BEFORE COMMENCING WORK. THE LOCATIONS OF UTILITIES, STRUCTURES AND SERVICES SHOWN IN THESE PLANS ARE APPROXIMATE ONLY. ANY DISCREPANCIES BETWEEN THESE PLANS AND ACTUAL FIELD CONDITIONS SHALL BE REPORTED TO THE OWNER'S REPRESENTATIVE. THE CONTRACTOR SHALL OBTAIN THE PERTINENT ENGINEERING OR ARCHITECTURAL PLANS BEFORE BEGINNING WORK. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS REQUIRED TO PERFORM THE WORK INDICATED HEREIN BEFORE BEGINNING WORK. INSTALL ALL EQUIPMENT AS SHOWN IN THE DETAILS AND SPECIFICATIONS. CONTRACTOR SHALL BE RESPONSIBLE TO COMPLY WITH LOCAL CITY, COUNTY AND STATE REQUIREMENTS FOR BOTH EQUIPMENT AND INSTALLATION. ALL PIPE UNDER PAVED AREAS TO BE INSTALLED IN SLEEVING TWICE THE DIAMETER OF THE PIPE CARRIED. SEE LEGEND FOR TYPE. ALL WIRE UNDER PAVED AREAS TO BE INSTALLED IN A SCH. 40 SLEEVE THE SIZE REQUIRED TO EASILY PULL WIRE THROUGH. ALL SLEEVES TO BE INSTALLED WITH A MINIMUM DEPTH AS SHOWN ON THE SLEEVING DETAILS. SLEEVES TO EXTEND AT LEAST 12" PAST THE EDGE OF THE PAVING. STATEMENT OF WATER CONSERVATION Please note the following principles of design utilized on this project directed specifically as conserving water and improving the efficiency of the irrigation system: All head spaced head to head 100% of manufacturers recommended radius.. All sprinkler heads utilize matched precipitation nozzles and check valves. All sprinkler heads utilize pressure compensating screens. Triangular spacing utilized for head layout throughout irrigation system. Irrigation zones separated by plant material types. Irrigation zones separated by exposure and orientation. Utilization of irrigation system master valve. Utilization of irrigation system flow sensor. Utilization of rain shut-off device connected to irrigation controller. Utilization of controller with water budgeting feature. IRRIGATION SYSTEM SHALL BE TESTED AND MAINTAINED ON A MONTHLY BASIS BY THE MAINTENANCE STAFF. AN IRRIGATION AUDIT, IN COMPLIANCE WITH THE STATE OF CALIFORNIA LANDSCAPE WATER MANAGEMENT PROGRAM, SHALL BE PERFORMED BY A CERTIFIED IRRIGATION AUDITOR PRIOR TO TURNOVER OF PROJECT AND EVERY 5 YEARS THEREAFTER. THE REGULAR MAINTENANCE SCHEDULE COUPLED WITH THE AUDITS SHOULD HELP TO MAINTAIN THE IRRIGATION EFFICIENCY AS INTENDED IN THE DESIGN IRRIGATION WATER AUDIT NOTE: MAINTENANCE COMPANY TO PROVIDE AN IRRIGATION AUDIT, IN COMPLIANCE WITH THE STATE OF CALIFORNIA LANDSCAPE WATER MANAGEMENT PROGRAM, SHALL BE PERFORMED BY A CERTIFIED IRRIGATION AUDITOR PRIOR TO TURNOVER OF PROJECT AND EVERY 5 YEARS THEREAFTER. A SCHEDULE SHALL BE ESTABLISHED AND SUBMITTED TO THE CITY OF AT LEAST ONCE EVERY FIVE YEARS AS REQUIRED BY THE CITY, THE REGULAR MAINTENANCE SCHEDULE COUPLED WITH THE AUDITS SHOULD HELP TO MAINTAIN THE IRRIGATION EFFICIENCY AS INTENDED IN THE DESIGN. IRRIGATION SYSTEM SHALL BE TESTED AND MAINTAINED ON A MONTHLY BASIS BY THE MAINTENANCE STAFF. WATER CONSERVATION NOTES THE FOLLOWING WATER CONSERVATION TECHNIQUES SHALL BE EMPLOYED IN THIS PROJECT: • WATER CONSERVING PLANTS, AND PLANTS NATIVE TO HOT, DRY SUMMERS, UTILIZED IN 95% OF THE TOTAL PLANT AREA. • IRRIGATION ZONES SEPERATED BY PLANT MATERIAL. • USE OF HYDROZONES WITH PLANTS GROUPED BASED UPON AMOUNT OF WATER NEEDED TO SUSTAIN THEM. • SOIL AMENDMENTS UTILIZED TO IMPROVE WATER HOLDING CAPACITY OF SOIL. • AUTOMATIC IRRIGATION SYSTEM ADJUSTED SEASONALLY AND WITH WATERING HOURS BETWEEN 9:00 P.M. AND 9:00 A.M. • IRRIGATION SYSTEM DESIGNED TO WATER DIFFERENT AREAS OF THE LANDSCAPE BASED ON WATERING NEED. • RECOMMENDATIONS GIVEN FOR ANNUAL IRRIGATION SCHEDULE. IRRIGATION LEGEND SYMBOL MANUFACT. MODEL NO. / DESCRIPTION RADIUS GPM PSI GARDEN SPRAY / BUBBLER ❑ TORO 570Z-6P-COM-PRX-OT-5Q , 5H SPRAY POP-UP 5' .06, .13 30 V TORO 570Z-6P-COM-PRX-OT-8Q, 8H SPRAY POP-UP 8' .17, .33 30 TREE BUBBLER ;z HUNTER EACH SYMBOL REPRESENTS (2) HUNTER PROS -04, 4" POP-UP WITH A PCN H.5 GPM FLOOD BUBBLERS PER TREE. —$ HUNTER EACH SYMBOL REPRESENTS (2) HUNTER PROS -04, 4" POP-UP WITH A PCN H.5 GPM FLOOD BUBBLERS PER PALM. POINT TO POINT DRIP NO SYMBOL RAIN BIRD SYMBOL INDICATES SCH 40 PVC MANIFOLD WITH XT -700 DISTRIBUTION TUBING THAT STUBS OFF FOR PLANTER AREAS. EACH SHRUB REQUIRES (2) EMITTERS. SEE PLANTING PLAN FOR PLANT QUANTITY AND LOCATIONS. n EACH EMITTER TO INCLUDE A RAINBIRD (XB-20PC 2gph EMITTER), (TS -025 STAKE) , (DCB -025 OR PC DIFFUSER CAP) AND (XQ DISTRIBUTION TUBING - MAX. LENGTH OF DISTRIBUTION TUBING TO BE 6', ADD STAKES AS NEEDED) Q RAIN BIRD INSTALL A MCDCFCOUP WITH A MDCFCAP FLUSH CAP AT LOW POINTS OF DRIPLINE OR PCV MANIFOLD LINE, INSTALL FLUSH VALVE INSIDE A SEPERATE VALVE BOX, ONE AT THE END OF TUBING RUNS IN EACH DIRECTION. INSTALL MIN. ONE FLUSH VALVE PER 1000' OF TUBING IN EACH DIRECTION ON DRIPLINE FLUSH MANIFOLD. INSTALL 18" FROM PAVING. INSTALL ALL FLUSH EQUIPMENT PER MANUFACTURER'S SPECIFICATIONS. PROVIDE A 18" LOOP TO TUBING. (MIN. (1) REQUIRED PER SYSTEM - LOCATE BEST LOCATION IN FIELD) ® RAIN BIRD ARV -100 AIR/VACUUM RELIEF VALVE INSTALLED WITH A FT -050 CONBINATION TEE AND A 3/4" X 1/2" REDUCER BUSHING, INSTALL AIR RELIEF ASSEMBLY VALVE TO ALL DRIPLINE LATERALS WITHIN THE ELEVATED AREA. MULTIPLE ARV'S SHALL BE REQUIRED PER RCV WITHIN UNDULATING AREAS, VERIFY QUANTITY PRIOR TO STARTING WORK, INSTALL VALVE BOX 18" FROM PAVING AND AT HIGH POINTS OF PLANTER AREA. INSTALL ALL AIR VACUUM RELIEF EQUIPMENT PER MANUFACTURER'S SPECIFICATIONS. (MIN. (1) REQUIRED PER SYSTEM - LOCATE BEST LOCATION IN FIELD) NO SYMBOL RAIN BIRD ALL CONNECTIONS BETWEEN DRIP TUBING SHALL BE MADE USING "RAIN BIRD EASY FIT" FITTINGS TURF SUB -SURFACE DRIP IRRIGATION RAIN BIRD XFS-06-12 DRIP TUBING W/ 0.6 GPH EMITTERS 12" ON CENTER, INSTALL TUBING ROWS A MAXIMUM OF 14" APART IN TURF AREAS. ALL TUBING SHALL BE INSTALLED 4" BELOW FINISHED SOIL GRADE W/ 9" WIRE STAKES FIVE (5) FEET ON CENTER; VERIFY THE LAYOUT AND SPACING IN THE FIELD PRIOR TO STARTING WORK. RAIN BIRD MDCFEL or MDCFTEE W/ MDCF75FPT FITTING FOR CONNECTION BETWEEN PVC LATERAL LINES AND DRIP TUBING 0 HUNTER ACC -99D -PED -SS, (99) STATION PEDESTAL MOUNTED IRRIGATION CONTROLLER. LOCATE PER OWNER / DEVELOPER AWAY FROM VIEWS. INCLUDE A STAINLESS STEEL ENCLOSURE PER LEGEND / DETAIL 2 WIRE SYSTEM VALVES WILL REQUIRE ICD -100 -ICD-600 MODULES. ICD -SEN FOR SENSORS. ® HUNTER WSS-SEN SOLAR SYNC WEATHER SENSING KIT TO BE INCLUDED AND INSTALLED WITH THE CONTROLLER. INSTALL ON ADJACENT BUILDING IN FULL SUN WITHIN 800' LINE OF SITE TO CONTROLLER. © TORO CFD STANDARD CONTROLLER TO BE A SENTINEL 12 STATION CONTROLLER ESB12-U2-MPEA161OK-OB1-VRA REFER TO CITY OF FONTANA STD. PLAN NO. 5005 1-3. CONTROLLER ASSEMBLY AVAILABLE THRU: AQUA FLO CONTACT IS TOM RADEN 805.895.8909 © TORO CFD STANDARD CONTROLLER TO BE A SENTINEL 12 STATION CONTROLLER ESB12-U2-MPEA161OK-OB1-VRA REFER TO CITY OF FONTANA STD. PLAN NO. 5005 1-3. CONTROLLER ASSEMBLY AVAILABLE THRU: AQUA FLO CONTACT IS TOM RADEN 805.895.8909 0 N/A 120 VOLT ELECTRICAL POWER, PROVIDED BY ELECTRICIAN, VERIFY ACTUAL LOCATION IN FIELD H NIBCO T-113 BRONZE GATE VALVE- LINE SIZE OCFD P.O.C. (2) V WATER METER WITH A 1.5" SERVICE LINE, VERIFY SIZE, LOCATION, PRESSURE INFORMATION FROM: FONTANA WATER CO. 909.201.7353 AVAILABLE STATIC PRESSURE: 120 PSI, RESIDUAL PRESSURE 110 PSI, WITH 3280 MAX. FLOW ® HOA P.O.C. (2) 1.5" WATER METER WITH A 2" SERVICE LINE, VERIFY SIZE, LOCATION, PRESSURE INFORMATION FROM: FONTANA WATER CO. 909.201.7353 AVAILABLE STATIC PRESSURE 120 PSI, RESIDUAL PRESSURE 110 PSI, WITH 3280 MAX. FLOW FEBCO (2) 2" 825YA REDUCED PRESSURE TYPE BACKFLOW DEVICE. INSTALL IN A STRONG BOX, SMOOTH TOUCH ENCLOSURE PER DETAIL. a HAYWARD (2) 2" MODEL #72 BASKET STRAINER 2" SIZE W/ FLANGED CONNECTIONS AND 80 MESH FILTER ELEMENT. 0 SUPERIOR (2) MODEL 3200 1.5" NORMALLY CLOSED MASTER CONTROL VALVE HUNTER (2) HFS-250-FCT-250 FLOW SENSOR, INSTALL PER MANUFACTURER'S RECOMMENDATIONS AND WIRE TO CONTROLLER RAIN BIRD 33 DRC QUICK COUPLER VALVE W/ (YELLOW) LOCKING CAP ® TORO EZF-2-9-03 OR 4 (3/4" OR 1") PLASTIC AUTOMATIC ANTISIPHON VALVE, INSTALL 12" ABOVE HIGHEST HEAD SERVED TORO (LOW FLOW VALVE RANGE .25 - 8.0 GPM) (MED FLOW VALVE RANGE 2.0 - 20.0 GPM) SEE PLAN FOR VALVE SIZE - DZK-TPV-075-LF (3/4" VALVE) OR DZK-TPV-1-MF (1" VALVE) PLASTIC DRIP CONTROL VALVE, WITH MESH WYE FILTER AND PRESSURE REGULATOR. INSTALL BOTH ON THE DOWNSTREAM SIDE OF EACH DRIP RCV IN A VALVE BOX. O TORO TPVF100MM V LOW FLOW REMOTE CONTROL VALVE. AS APPROVED PVC PIPE 3/4" - 2" SCH. 40 AS LATERAL LINES 12" BELOW GRADE AS APPROVED PVC PIPE 2.5" CL. 315 AS MAINLINES 18" BELOW GRADE AS APPROVED PVC PIPE SCH. 40 AS SLEEVING, TWICE THE DIAMETER OF PIPE OR WIRE BUNDLE CARRIED PLACE BELOW ALL PAVING, HARDSCAPE, ETC., AND AS DIRECTED BY OWNER'S AUTHORIZED REPRESENTATIVE. NO SYMBOL AS APPROVED IRRIGATION CONTROL WIRE #14UF AWG DIRECT BURIAL (U.L. APPROVED) NO SYMBOL 3M DBY DIRECT BURIAL WATER -PROOF WIRE CONNECTORS FOR USE ON ALL WIRE CONNECTIONS NO SYMBOL K.B.I. KSC-XXX-S SWING L, 1ECK VALVE, LINE SIZE, 1 DOWNSTREAM OF EACH RCV WHEN RCV IS LOWER THAN THE SPRINKLERS NO SYMBOL K.B.I. KC -XXX -S SPRING HECK VALVE, LINE SIZE, 1 DOWNSTREAM OF EACH RCV IMMEDIATELY ABOVE FIRST LATERAL LINE TEE, WHEN RCV IS HIGHER THAN THE SPRINKLERS VALVE NUMBER G.P.M. XX XX VALVE TYPE I VALVE SIZE Landscape Maintenance Schedule 1) Landscapes shall be maintained to ensure water efficiency. A regular maintenance schedule shall include but not limited to checking, adjusting, cleaning and repairing equipment; resetting the automatic controller, aerating and detaching turf areas; replenishing mulch; fertilizing; pruning; and weeding in all landscape areas. 2) Repair of irrigation equipment shall be done with the originally specified materials or their approved equivalents. Operation and Maintenance Manuals: Prepare and deliver to the IRWD Representative, prior to the start of maintenance, all required and necessary descriptive material in complete detail and sufficient quantity, properly prepared in four individually bound copies. Describe the material installed in sufficient detail to permit qualified operating personnel to understand, operate and maintain all equipment. Each manual shall include the following: i. Index sheet indicating the Contractor's name, address and telephone number, fax number and e-mail address. ii. Duration of guarantee period with guarantee forms. iii. List of equipment with names and addresses of manufact rer's local representatives. iv. Complete operating and maintenance instructions on all major equipment. Oak PLANT / GROUND COVER EMITTER LEGEND PLANT WATER TYPE USE # OF EMITTERS / GPH LOW SHRUBS 1.0 GPH RAINBIRD XB-10PC LOW MODERATE SHRUBS 2.0 GPH RAINBIRD XB-20PC MODERATE SHRUBS 2.0 GPH RAINBIRD XB-20PC TREES 2 - BUBBLER (.5 GPM) DRIP SYSTEM NOTES: CONTRACTOR TO PROVIDE THE QUANTITY OF EMITTERS BASED ON THE ACTUAL PLANT COUNT AND THE EMITTER LEGEND SHOWN ABOVE. ANY REFERENCE TO EMITTER QUANTITIES ON THESE PLANS IS FOR DESIGN USE ONLY. VERIFY THE ACTUAL PLANT QUANTITIES AND SIZES FROM THE LANDSCAPE PLANS PRIOR TO BIDDING OR STARTING WORK. DRIP SYSTEM HAS BEEN DESIGNED TO ACCOMMODATE THE UPSIZING OF EMITTERS TO COMPENSATE FOR FUTURE PLANT GROWTH. MAINTENANCE PERSONNEL SHALL UPGRADE EMITTER SIZES AS REQUIRED TO PROVIDE ADEQUATE WATER FOR HEALTHY PLANT GROWTH. D.R.HORTON TRACT 18245 - CFD LANDSCAPE PLANS DRAWN BY: W SCALE: CN IRRIGATION NOTES/LEGEND NTS DESIGNED BY: DATE - RHI /fir 06-16-14 CHECKED BY: __ DRAWING NO: 6 Z nQ 5132 O SMP 13 CITY ENGINEER RCE NO. 51152 DATE SUMMERS/MURPHY A PARTNERS, INC LANDSCAPE ARCHITECTS 34197 COAST HIGHWAY, SUITE 200 DANA POINT, CALIFORNIA 92629 (949) 443.1446 FAX (949) 443-1631 �O \,ANDSCgpF 7-31-14 J'T Date �P OF CALtfO�� These drawings and/or the accompanying specifications are the exclusive property of Summers/Murphy & Partners, Inc. and their use and publi— cation shall be restricted to the original site for which they were prepared. Re—use, repro— duction or publication by any method, in whole or part, is prohibited except by written permission from Summers/ Murphy & Partners, Inc. SHEEP DESCRIPTION IRRIGATION NOTES &LEGEND DESIGNED SMP DRAWN SMP CHECKED SMP DATE 10/30/13 J1013 NO. 616005 CAD RLE SHEET NUMBER OF 13 SHE CD (V m r C) LCI W a) L3. FW -- Z_ 2 W U W 0 ad IL F— Z Z O to O OV W ,Z W 9 ....i Z O V U in z V z 20 W __ Q Z Z nQ O O O C� Qi Oo�tM SHEEP DESCRIPTION IRRIGATION NOTES &LEGEND DESIGNED SMP DRAWN SMP CHECKED SMP DATE 10/30/13 J1013 NO. 616005 CAD RLE SHEET NUMBER OF 13 SHE CD (V m r C) LCI W a) L3. FW -- Z_ 2 W U W 0 ad IL F— Z Z O to W ....i V Q 000 3 ZO Qi Oo�tM V CC 3: Z _ M LU 3 OCNOU) © (� O O N V 0) W H Z O a. W 0 Z W co QZ > Z� O Oa a: 0a. W avow ..J H N Go Z �.-. Z a W o Z 01 V 0 U to i— U. U SHEEP DESCRIPTION IRRIGATION NOTES &LEGEND DESIGNED SMP DRAWN SMP CHECKED SMP DATE 10/30/13 J1013 NO. 616005 CAD RLE SHEET NUMBER OF 13 SHE CD (V m r C) LCI W a) L3. FW -- Z_ 2 W U W 0 ad IL F— Z Z O to