Loading...
HomeMy WebLinkAbout5024-1GENERAL NOTES 1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED. 2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT THE CITY ENGINEER FOR RESOLUTION. 3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER. 4. ADVANCE CONSTRUCTION SIGNING INDICATING DURATION OF PROJECT SHALL BE IN PLACE ONE WEEK PRIOR TO IMPLEMENTING DETOURS. 5. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 6. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. 7. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL 8. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. Q. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL FOR GROUND MOVEMENT EXISTS. 10. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT 11. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND THE ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION. 12. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES. 13. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS. 14. STATIONING REFERS TO THE CENTERLINE OF STORM DRAIN EXCEPT WHERE OTHERWISE NOTED. 15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION. 16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCHMARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER. 17. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCHMARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT. 18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES, A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 19. THE CONTRACTORS SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES. 20. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL. 21. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 22. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS 23. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS. j YOU DIG / YOU DIG TOIL FREE 1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT REV. 24. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE. 25. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE CITY ENGINEER. 26. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS. 27. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY. 28. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. 29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS. 30. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT. 31. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING. 32. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER. 33. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER. 34. MINIMUM D -LOAD FOR ALL RCP IS 1350. 35. THE CONCRETE COATING ON THE INSIDE OF ALL REINFORCED CONCRETE PIPES MUST BE INCREASED TO PROVIDE A MINIMUM OF 1-112- OVER THE REINFORCING WHEN THE DESIGN VELOCITIES EXCEED 20 FEET PER SECOND. THE CONCRETE DESIGN STRENGTH IN THESE REACHES SHALL BE FC=5,000 PSI FOR VELOCITIES EXCEEDING 20 FEET PER SECOND AND FC=6,000 PSI FOR VELOCITIES EXCEEDING 30 FEET PER SECOND. CITY OF FONTANA, UTILITY NOTIFICATION LIST CITY OF FONTANA AT&T 8353 SIERRA AVE 22311 BROOKHURST ST SUITE 203 FONTANA, CA 92335 HUNTINGTON BEACH, CA 92646 (909) 350-6632 (714) 963-7964 SO. CALIF. GAS COMPANY SPRINT 1981 W. LUGONIA AVE 2592 DUPONT DR REDLANDS, CA 92374 IRVINE, CA 92612 (909) 335-7967 (800) 659--9698 EMERGENCIES: (800) 427-2200 TIME WARNER CABLE SO. CALIF. EDISON COMPANY 1500 AUTO CENTER DR 300 N. PEPPER AVE ONTARIO, CA 91761 RIALTO, CA 92376 (909) 975-3439 909 820-5598 - UNDERGROUND SUNESYS, LLC 909 875-5100 - TRANSMISSION 1325 PICO ST 1106 213 637-1233 - PIPELINES CORONA, CA 92881 909 357-6505 - DISTRIBUTION (951) 278-040C UNDERGROUND SERVICE ALERT (800) 422-4133 FONTANA WATER COMPANY 15966 ARROW BOULEVARD FONTANA, CA 92335 (909) 822-2201 - - - CENTERLINE -- RIGHT-OF-WAY LINE CONTOUR LINE -- STREET LIGHTS DIRECTION OF FLOW o SEWER MANHOLE O STORM DRAIN MANHOLE THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES AND/OR STRUCTU,'ES SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. THESE LOCATIONS ARE APPROXIMATE AND SHALL BE CONFIRMED BY THE CONTRACTOR, SO THAT ANY NECESSARY ADJUSTMENT CAN BE MADE IN ALIGNMENT AND/OR GRADE OF THE PROPOSED IMPROVEMENT. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT ANY UTILITY LINES SHOWN AND ANY OTHER LINES NOT ON RECORD OR NOT SHOWN ON THESE PLANS. CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, HE WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, INCLUDING THE SAFETY OF ALL PERSONS AND PROPERTY. THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN PROFESSIONAL AND THE CITY OF FONTANA HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE DESIGN PROFESSIONAL. UNAVEHORM GRANGES AND USESc THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR OR LIABLE FOR, UNAUTHORIZED CHANGES TO OR USES OF THESE PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND MUST BE APPROVED BY THE PREPARER OF THESE PLANS. REVISION DESCRIPTION DATE I ENGR. I DATE I CITY CITY OF FONTANA FOOTHILL BOULEVARD STORM DRAIN PLANS R/W 60' NORTH 1/2 TYPICAL SECTION FOOTHILL BOULEVARD - 12W R/W STA. 128+90..00 TO STA 136+00.00 SHOULD CONSTRUCTION OF REQUIRED AnOVEMDYTS NOT COMMHVCE wrrHIN TWO YEARS OF THE DATE OF AMOVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANN, THE CITY ENGINEER MAY REQIARE REVISIONS TO THE F IANS TO BRM THEM INTG `:" WITH CONDITIONS AND STANDARDS IN EFFECT NTS BASIS OF BEARINGS.- EARINGS:BASIS BASISOF BEARINGS: TAKEN FROM THE CENTERLINE OF LIME AVENUE AS SHOWN ON TRACT NO. 16271-1, M.B. 297/15-18. BEING N 00'01'12" W ORIGINAL BENCHMARK (SINCE DESTROYED) CITY OF FONTANA BENCHMARK NO. 361 RAILROAD PREPARED FOR: SPIKE IN NORTH FACE OF POWER POLE LENNAR HOMES NO. 1536697E AT THE S.W. CORNER OF SULTANA AVENUE AND BASELINE AVENUE. ELEVATION: 1365.01 980 MONTECITO DRIVE, SUITE 302 CORONA, CA 92879 SITE BENCHMARK (951) 817-3545SAN BERNARDINO COUNTY BENCHMARK NO. 7-15 1970" FAX (951) 817-3650 BRASS CAP IN CONCRETE ABUTMENT, LOCATED 34' NORTH OF CENTERLINE OF FOOTHILL BLVD. AND 131' WEST OF CENTERLINE OF LIME AVENUE. ADS &NAWNk MW R/W 60' CONTRACTOR TO REESTABLISH ROADSIDE SWALE AFTER j I CONSTRUCTION j WIDTH VARIES I 7' 8' 26' NORTH 1/2 TYPICAL SECTION FOOTHILL BOULEVARD - 120' R/W STA 136+00.00 TO STA 147+80.00 B0 Prepared By: ALLARD ENGINEERING Civil Engineering - Land Surveying - Land Planning 16866 Seville Avenue Fontana, California 92335 pq#a (909)) 356-1815 Fax (909) 434-1820 _C9 - q -1(0 Raymond I. Allard, A.C.E. 36052 Date (expires 6/30/2014) PROJECT � LOCATION -------------------j G� R z W 3 N aN NORTH 1/2 TYPICAL SECTION FOOTHILL BOULEVARD - 120' R/W STA 136+00.00 TO STA 147+80.00 B0 Prepared By: ALLARD ENGINEERING Civil Engineering - Land Surveying - Land Planning 16866 Seville Avenue Fontana, California 92335 pq#a (909)) 356-1815 Fax (909) 434-1820 _C9 - q -1(0 Raymond I. Allard, A.C.E. 36052 Date (expires 6/30/2014) PROJECT � LOCATION VICINITY MAP NIS THS QUANTITIES SHOWN HEREON ARE ESTIMATES ONLY. THE CONTRACTORS SHALL PREPARE THEIR OWN QUANTITIES AND BID A COMPLETE JOB. CONSTRUCTION NOTES ESTIMATED QUANTITIES INSTALL 36" RCP (1350-D) 1863 LF 2 REMOVE BRICK & MORTAR PLUG AND CONNECT TO EXISTING STORM DRAIN 1 EA 3 CONSTRUCT MANHOLE PER CITY STD. 3012 4 EA 4 CONSTRUCT TRANSITON STRUCTURE PIPE TO PIPE PER CITY STD. 3026 1 EA 5 CONSTRUCT STANDARD TRENCH REPAIR PER CITY STD. 1008 1890 LF 6 CONSTRUCT BRICK/MORTAR BULKHEAD IF NECESSARY (SEE NOTE 4) 111 EA TOP OF STRUCTURAL PAVEMENT SUBGRADE 1:1 SLOPE OR FLATTER OR ADEQUATE SHORING GRANULAR BEDDING FROM SELECTED TRENCH SIDE MATERIAL (1" MAX SIZE) GRANULAR BEDDING FROM SELECTED TRENCH SIDE MATERIAL FOR PIPE 10' OR GREATER IN DEPTH USE 1/2 CRUSHED STONE BEDDING - , STORM DRAIN I. CONTRACTOR TO COORDINATE INGRESS AND EGRESS OF PRIVATE DRIVEWAYS WITH LAND OWNERS DURING CONSTRUCTION 2. CONTRACTOR TO VERIFY LOCATION AND ELEVATION OF EXISTING UTILITIES PRIOR TO START OF CONSTRUCTION. 3. CONTRACTOR RESPONSIBLE TO RESTORE ALL DISTURBED IMPROVEMENTS (CURB, METERS AND SIGNS ETC.) AFTER CONSTRUCTION. 4. DON'T CONSTRUCT BULKHEAD IF SULTANA STORM DRAIN IS IMMINENT. 1v 90% COMPACTED NATIVE BACKFILL 6" MAX SIZE 6" MIN. 8 TRENCH DETAIL NTS 3" MAX. SIZE NATIVE SOIL COMPACTED 95% NOTES: I. TRENCH WIDTH SHALL BE CONTROLLED TO TOP OF PIPE ZONE 2. TRENCH DEPTHS OF GREATER THAN 5' SHALL HAVE ADEQUATE SHORING 3. CLASS II AGGREGATE BASE ALL TRENCHES LESS THAN 100 FEET IN LENGTH NOTE: COMPACTION SHALL BE 90% IN ALL ZONES UNLESS OTHERWISE SPECIFIED. TRENCH STABILITY SHALL CONFORM TO CAL -OSHA REQUIREMENTS 5. CONTRACTOR TO COORDINATE TRAFFIC CONTROL WITH CITY ENGINEER 6. POSSIBLE GAS LATERAL EXIST FOR VACANT FOUNDATIONS CONTRACTOR TO VERIFY POSSIBLE GAS LOCATIONS Q�OF E SS, otic CITY OF FONTANA CALIFORNIA ° oN° A<< OFFSITE STORM DRAIN IMPROVEMENT PLAN z DRAWN NoBKA FOOTHILL BOULEVARD SCALE. U . 36052 m AS NOTED DESIGNED BY: ST RM DRAIN Exp. 6/30/14 _. DATE: BKA APRIL, 2013 C I v I CAS �E CHECKRJA Y DATE: l� • ( ED DRAWING NO.: 1 CITY ENGINEER R.C.E 51152 5024 3 Filename: 1:\15917 Young Homes Lime I and 11\0ffsite Improvements\DWG's\Storm Drain\Final Design\Foothill\FOOTHILL-SDOI.dwg A VENUE WALNUT BASELINE AVENUE '�N MILLER �Ir� I AVENUE FOOTHILL BOULEVARD -4 O ARROW _ N w BOULEVARD = m _ V t= Q VICINITY MAP NIS THS QUANTITIES SHOWN HEREON ARE ESTIMATES ONLY. THE CONTRACTORS SHALL PREPARE THEIR OWN QUANTITIES AND BID A COMPLETE JOB. CONSTRUCTION NOTES ESTIMATED QUANTITIES INSTALL 36" RCP (1350-D) 1863 LF 2 REMOVE BRICK & MORTAR PLUG AND CONNECT TO EXISTING STORM DRAIN 1 EA 3 CONSTRUCT MANHOLE PER CITY STD. 3012 4 EA 4 CONSTRUCT TRANSITON STRUCTURE PIPE TO PIPE PER CITY STD. 3026 1 EA 5 CONSTRUCT STANDARD TRENCH REPAIR PER CITY STD. 1008 1890 LF 6 CONSTRUCT BRICK/MORTAR BULKHEAD IF NECESSARY (SEE NOTE 4) 111 EA TOP OF STRUCTURAL PAVEMENT SUBGRADE 1:1 SLOPE OR FLATTER OR ADEQUATE SHORING GRANULAR BEDDING FROM SELECTED TRENCH SIDE MATERIAL (1" MAX SIZE) GRANULAR BEDDING FROM SELECTED TRENCH SIDE MATERIAL FOR PIPE 10' OR GREATER IN DEPTH USE 1/2 CRUSHED STONE BEDDING - , STORM DRAIN I. CONTRACTOR TO COORDINATE INGRESS AND EGRESS OF PRIVATE DRIVEWAYS WITH LAND OWNERS DURING CONSTRUCTION 2. CONTRACTOR TO VERIFY LOCATION AND ELEVATION OF EXISTING UTILITIES PRIOR TO START OF CONSTRUCTION. 3. CONTRACTOR RESPONSIBLE TO RESTORE ALL DISTURBED IMPROVEMENTS (CURB, METERS AND SIGNS ETC.) AFTER CONSTRUCTION. 4. DON'T CONSTRUCT BULKHEAD IF SULTANA STORM DRAIN IS IMMINENT. 1v 90% COMPACTED NATIVE BACKFILL 6" MAX SIZE 6" MIN. 8 TRENCH DETAIL NTS 3" MAX. SIZE NATIVE SOIL COMPACTED 95% NOTES: I. TRENCH WIDTH SHALL BE CONTROLLED TO TOP OF PIPE ZONE 2. TRENCH DEPTHS OF GREATER THAN 5' SHALL HAVE ADEQUATE SHORING 3. CLASS II AGGREGATE BASE ALL TRENCHES LESS THAN 100 FEET IN LENGTH NOTE: COMPACTION SHALL BE 90% IN ALL ZONES UNLESS OTHERWISE SPECIFIED. TRENCH STABILITY SHALL CONFORM TO CAL -OSHA REQUIREMENTS 5. CONTRACTOR TO COORDINATE TRAFFIC CONTROL WITH CITY ENGINEER 6. POSSIBLE GAS LATERAL EXIST FOR VACANT FOUNDATIONS CONTRACTOR TO VERIFY POSSIBLE GAS LOCATIONS Q�OF E SS, otic CITY OF FONTANA CALIFORNIA ° oN° A<< OFFSITE STORM DRAIN IMPROVEMENT PLAN z DRAWN NoBKA FOOTHILL BOULEVARD SCALE. U . 36052 m AS NOTED DESIGNED BY: ST RM DRAIN Exp. 6/30/14 _. DATE: BKA APRIL, 2013 C I v I CAS �E CHECKRJA Y DATE: l� • ( ED DRAWING NO.: 1 CITY ENGINEER R.C.E 51152 5024 3 Filename: 1:\15917 Young Homes Lime I and 11\0ffsite Improvements\DWG's\Storm Drain\Final Design\Foothill\FOOTHILL-SDOI.dwg