-OF-WAY DELINEATED ON THE PLANS WAS OBTAINED FROM THE CITY OF FONTANA AND ONTARIO GIS
.JRVEY RECORDS AND SITE SURVEYS.
ANDARD METHODS AND AVAILABLE RECORDS HAVE CONFIRMED THE EXISTENCE OF THE UNDERGROUND
!TIES SHOWN ON THESE PLANS. THE INDICATED LOCATIONS OF THESE UTILITIES ARE APPROXIMATE AND
NOT BE COMPLETE. ALL UTILITIES ARE TO BE FIELD VERIFIED BY THE CONTRACTOR.
o. PRIOR TO THE COMMENCING WORK, ALL EXISTING SITE AND TRACK CONDITIONS SHALL BE FIELD VERIFIED
WITH THE ENGINEER TO ASCERTAIN THE LIMITS OF THE WORK ACTIVITIES. THE CONTRACTOR SHALL SUBMIT
AND RECEIVE THE ENGINEER'S APPROVAL OF THE PROJECT SCHEDULE AND THE OPERATIONS PLAN. EACH ITEM
OF WORK SHALL BE DESCRIBED AND ACCOUNTED FOR IN BOTH DOCUMENTS. REFER TO SPECIFICATIONS FOR
FURTHER INFORMATION REGARDING SUBMITTAL REOUIREMENTS.
7. THE INDICATED LOCATION OF FIBER OPTIC CABLE IS APPROXIMATE AND MUST BE VERIFIED BY THE
CONTRACTOR PRIOR TO ANY EXCAVATION OR OTHER WORK IN THE VICINITY. THE CONTRACTOR WILL BE
RESPONSIBLE TO REPAIR/REPLACE. AT HIS EXPENSE, ANY CABLES AND ALL ASSOCIATED WORK THEY DAMAGE
INCLUDING PAYMENT OF ANY DAMAGE CLAIMS BY THE UTILITY COMPANY.
8. ALL CONSTRUCTIONS SHALL BE SCHEDULED AND COORDINATED THROUGH THE ENGINEER AND WITH THE
VARIOUS COMPANIES AND AGENCIES WHO MAY BE AFFECTED BY THIS WORK. ALL REQUIRED PERMITS NEEDED
FOR THE WORK SHALL BE OBTAINED BY CONTRACTORS UNLESS ALREADY PROVIDED.
9. THE CONTRACTOR WILL VERIFY THE INVERTS AND LOCATIONS OF ALL EXISTING DRAINAGE FACILITIES THAT
ARE TO REMAIN AND BE MAINTAINED.
10. EXISTING PIPES AND CULVERTS THAT ARE TO BE MAINTAINED WILL BE CLEANED AND FLUSHED AS
NECESSARY TO RESTORE FULL CAPACITY.
11. THE CONTRACTOR WILL FOLLOW ALL APPLICABLE SAFETY CODED, REGULATIONS AND SPECIFICATIONS.
12. THE CONTRACTOR IS RESPONSIBLE FOR THE RESTORATION OF ITS ORIGINAL CONDITION OF ANY
STRUCTURED INTENDED TO REMAIN IN PLACE.
13. RAIL TRAFFIC DISRUPTIONS SHALL BE KEPT TO A MINIMUM DURING THE EXECUTION OF THE WORK. SUCH
DISRUPTIONS THAT MAY BE REQUIRED SHALL BE COORDINATED WITH THE ENGINEER AND THE UNION
PACIFIC RAILROAD (UPRR) PER SECTION 02450 OF THE SPECIFICATIONS, IN ALL CASES.
14. ROADWAY TRAFFIC DISRUPTIONS SHALL BE KEPT TO A MINIMUM AS PRESCRIBED BY THE PERMITTING
AGENCY DURING CONSTRUCTION. ALL LANE CLOSURES SHALL BE COORDINATED WITH THE CITY AND/OR
AGENCIES HAVING JURISDICTION BEFOREHAND AND THE ENGINEER WILL BE KEPT FULLY INFORMED AS
TO SUCH REOUEST FOR CLOSURE.
15. ANY CONCRETE SLABS, FOUNDATIONS, BULK HEADS AND FENCING THAT INTERFERE WITH NEW WORK
SHALL BE DEMOLISHED AND REMOVED. ALL EXISTING FEATURES TO REMAIN SHALL BE LEFT INTACT OR
ADJUSTED TO PROVIDE A STABLE AND SAFE CONDITION COMPATIBLE WITH THE NEW WORK. ANY EXISTING
FEATURES TO REMAIN THAT HAVE BEEN DAMAGED BY THE CONTRACTOR'S OPERATIONS SHALL BE
RESTORED TO ITS ORIGINAL CONDITION TO THE SATISFACTION OF THE OWNER AT THE CONTRACTOR'S
EXPENSE.
16. ALL EXISTING UNDERGROUND UTILITIES WITHIN THE PROJECT SITE ARE TO REMAIN UNLESS
OTHERWISE NOTED. THE CONTRACTOR SHALL PROTECT THE EXISTING UTILITIES FROM DAMAGE DURING
THE COURSE OF THE OPERATIONS: TO CONTRACTOR SHALL REPAIR AND/OR RESTORE THE UTILITIES AT
HIS OWN EXPENSE TO THE SATISFACTION OF THE UTILITY OWNER.
17. ALL PROJECT AREAS TO BE SPRAYED WITH PRE—EMERGENT HERBICIDE UPON COMPLETION OF WORK.
18. CONTRACTOR SHALL REMOVE ALL EXISTING STRIPING FOR PRIOR TO APPLICATION OF SLURRY SEAL.
19. ALL STRIPING SHALL CONFORM TO THE CITY OF FONTANA AND ONTARIO PLAN NO. 1125'S. ALL ITEMS
OR DETAILS NOT COVERED IN THE CITY STANDARD PLANS SHALL CONFORM TO THE APPLICABLE SECTIONS
OF THE STATE OF CALIFORNIA STANDARD PLANS AND SPECIFICATIONS DATED JULY 2002.
20. ALL STRIPING AND PAVEMENT MARKINGS SHALL BE SPRAYABLE THIN MIL THERMOPLASTIC. ALL
CURB MARKINGS AND MEDIAN NOSE MARKINGS SHALL BE TRAFFIC PAINT UNLESS NOTED OTHERWISE.
21. ALL NEW REGULATORY AND WARNING SIGNS EXCEPT PARKING RESTRICTION SIGNS SHALL HAVE
ASTM TYPE IX REFLECTIVE SHEETING (3M DIAMOND VIP GRADE OR EOUIVALENT). ALL NEW SCHOOL
SIGNS SHALL BE FLUORESCENT YELLOW—GREEN. ALL OTHER SIGNS HAVE ASTM TYPE IIA (SUPER
ENGINEER GRADE)
22. ALL CONFLICTING STRIPING, PAVEMENT MARKINGS AND RAISED PAVEMENT MARKERS SHALL BE
REMOVED EVEN IF NOT SHOWN ON THE PLAN. REMOVAL OF STRIPING AND PAVEMENT MARKINGS
SHALL BE DONE BY WET SAND BLASTING AND/OR GRINDING. ALL DAMAGED PAVEMENT DUE TO
REMOVAL SHALL BE REPAIRED AS NECESSARY TO MAINTAIN A SMOOTH AND UNIFORMED SURFACE.
23. ALL FIRE HYDRANT LOCATIONS SHALL BE MARKED WITH BLUE REFLECTIVE RPM PER ONTARIO
STD. PLAN NO 4064.
CITY
RECOMMENDED BY:
ACCEPTED BY:
00
jaT
MAN ---- R-AINARRAMMM -------- MR
DIAL TWO WORKING
BEFORE DAYS BEFORE
YOU DIG YOU DIG
TOLL FREE -800-227-2600
A PUSLIC SERVICE BY L*DERGROUNdD SERVICE ALERT
REV,
..I-, 1 .. " 1 ..,
AND
AIRPORT DRIVE / SLOVER AVENUE
4t,E 401 apt
za Contillental
lictufv Stares
San Bema;_.dIno F n
E Air orl Dr E Agott th
lilupa H>t ti Jump at
UTILITY NOTIFICATION LIST
CITY OF FONTANA
ATTN: CURTIS AARON
16489 ORANGE WAY
FONTANA, CA 92335
( 909 ) 350-7610
INLAND EMPIRE "UTILITIES AGENCY"
ATTN: TAGHI MONZAVI
P.O. BOX 9020
CHINO HILLS, CA 91709
(909) 993-1693
CUCAMONGA VALLEY WATER DISTRICT
ATTN: HUGO BORJA
10440 ASHFORD STREET
RANCHO CUCAMONGA, CA 91729
(909) 987-2591
SAN GABRIEL WATER COMPANY
ATTN: LUIS MONTENEGRO
1142 GARVEY AVENUE
EL MONTE, CA 91733
(626) 448-6183
GOLDEN STATE (TIME WARNER TELECOM)
ATTN: BART HARTLEY
3281 GUASTI ROAD, #350
ONTARIO, CA 91761
(909) 456-3693
C'J
REvISIGN MCWTNON
DATE I ENGR. I CITY I DATE
4t'n Sl
0
3
4=�
San ElernarrAno Ave
VICINITY MAP
(NOT TO SCALE)
i
Selo enl r+fMQ F r
PROJECT LOCATION
SBC/PAC BELL
ATTN: PRE -ENGINEERING LIAISON
1265 N. VAN BUREN STREET, #180
ANAHEIM, CA 92807
( 714 ) 666-5692
LEVEL 3 COMMUNICATIONS
ATTN: AURA ADLAO BULURAN
1025 ELDORADO BLVD., BLDG 33A-522
BROOMFIELD, CO 80021
(720) 888-6482
SC GAS - CHINO
ATTN: B. WILKIE
1981 W. LUGONIA AVENUE, ML 8023
REDLANDS, CA 92373
(909) 335-3928
SC GAS - FONTANA
ATTN: B. WILKIE
1981 W. LUGONIA AVENUE, ML 8023
REDLANDS, CA 92373
(909) 335-3928
CITY OF ONTARIO
ATTN: -6HV A,&- 'D6,WkS MEa1&
1425 S. BON VIEW AVENUE
ONTARIO, CA 91761
( 909) 39S-2144,395-24013
Jw4zi Ave
CITY OF ONTARIO - TRAFFIC ENGINEERING
ATTN: HAR9 n RCDON 15MEW
303 EAST B STREET
ONTARIO, CA 91764
t 909 ) �" '- 3�5- 2154
CITY OF ONTARIO PARK DEPARTMENTS
ATTN: -PA� ROBCV.1'0 MM -4--
1425
1425 S. BON VIEW AVENUE
ONTARIO, CA 91761
( 909 ) 44+-2- 7- '3195- ZG27
KINDER MORGAN ENERGY PARTNERS
ATTN: DON QUINN
1100 TOWN & COUNTRY ROAD
ORANGE, CA 92868
( 714 ) 560-4400
PRAXAIR, INC.
ATTN: CURTIS STUBBINGS
5705 E. AIRPORT DRIVE
ONTARIO, CA 91761
(909) 974-5105
UTI (CHARTER COMMUNICATIONS)
ATTN: STUART KING
6680 VIEW PARK COURT
RIVERSIDE, CA 92503
(951) 343-5165
SHOULD CONSTRUCTION OF THE REQUIRED
IMPROVEMENTS NOT COMMENCE WITHIN TWO
YEARS OF THE DATE OF APPROVAL SHOWN HEREON
AND CARRIED FORTH IN A DILIGENT MANNER, THE
CITY ENGINEER MAY REQUIRE REVISIONS TO THE
PLANS TO BRING THEM INTO CONFORMANCE WITH
STANDARDS IN EFFECT.
UTI (SC EDISON DISTRIBUTION)
ATTN: EDISON OPERATOR
( 626) 302-1212
UTI (SC EDISON TELECOMMUNICATIONS)
ATTN: ROLANDO OLIVAS
501 S. MARENGO AVENUE, BUILDING E
(626) 308-6313
UTI (VERIZON - POMONA)
ATTN: ENGINEERING
(909) 469-6369
UTI (VERIZON - RANCHO CUCAMONGA)
ATTN: ENGINEERING
(909) 469-6369
WILTEL COMMUNICATIONS
ATTN: ROXANNE DORIS
ONE TECHNOLOGY CENTER, MD11
TULSA, OK 74103
(918) 547-3232
PREPARED UNDER THE SUPERVISION OF., CITY OF FONTANA, CALIFORNIA
PRTTERSON
& STREET IMPROVEMENT PLAN
ASSOCIf�TES, INC.
��g CCIIVpiI-TRRCfSUJORH ENGINEERING
OBLIGE. GA& COUNTRY RD.SUTE 300 E. LOPEEZ
E. LOPEZ
Dote CHECKEO BY
MARZIEH S.G. GHANDEHARI R.G.E. 62746 GHi4NDEHARI
APPROVED Si:
7•
..t
TITLE SHEET
SCALE:
AS SHOWN
DATE:
11/30/12
DRAwiG W,:01
49$4 A