HomeMy WebLinkAbout4961-1CITY OF FONTANA STREET IMPROVEMENT NOTES
1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS,
.)HE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS
CONSTRUCTIONS ("GREEN BOOK'). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE
LATEST EDITION UNLESS OTHERWISE NOTED.
2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE
RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK" THE CONTRACTORS
SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEERS FOR RESOLUTION.
J. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER.
4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY
DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK
INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE
START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610.
5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND
PROCEDURES DESCRIBED IN STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -
METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER.
6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS
OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES.
7. THE CONTRACTORS SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR
TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL
SAFETY.
8. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE
GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE
REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES
LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND
MOVEMENT.
9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING
A SEPARATE PERMIT FOR THAT PURPOSE.
10. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION,
4 HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD,
THE TR OCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER
PRECAUTION TO AVOID dAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND
SERVICE ALERT AT 1-800-277-2600 TWO WORKING DAYS BEFORE EXCAVATION,
11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING,
BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE
IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND
CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK
AROUND THEIR FACILITIES.
12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT
APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE
WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS.
13. CURVE DATA REFERS TO THE FACE OF CURB.
14. STATIONING REFERS TO THE CENTERLINE OF STREETS EXCEPT WHERE OTHERWISE NOTED.
15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE
CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADE(S). THE CONTRACTOR SHALL BE
RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING
DURING CONSTRUCTION.
16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH
MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER.
17. REMOVAL AND REPLACEMENT OR EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS,
MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR
LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS
CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK
PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER
REPLACEMENT OF THE MONUMENT.
18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESS AT ALL TIMES. A
MINIMUM 12 FOOT LAND SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR
RESIDENTS AND EMERGENCY VEHICLES.
19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL,
INCLUDING ADEQUATE WATERING, AT ALL TIMES.
20. ALL GRADING OPERATIONS SHALL BE DISCONTINUED WHEN SUSTAINED WIND VELOCITIES EXCEED 25 MILES
PER HOUR.
21. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT, OR DEBRIS TO BE
DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING
CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL.
22. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
23. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION, FAILURE TO OBTAIN THE
REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE
SPECIFIED DENSITY IS OBTAINED.
24. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET
IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY
NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS.
25, THE FINAL LOCATION AND WIDTH OF DRIVEWAY APPROACH APRONS SHALL BE APPROVED AT THE
TIME OF CONSTRUCTION AND SHALL CONFORM TO THE CITY OF FONTANA STANDARD DETAILS.
26. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH
EXISTING CONCRETE.
27. THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE CURB AT THE LOCATION OF THE
SEWER LATERAL.
28. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED,
INSPECTED AND APPROVED.
29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF
STREETS.
30. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO
PLACEMENT
31. PAVEMENT STRUCTURAL SECTIONS SHOWN ARE MINIMUM AND SUBJECT TO REVISION AND
APPROVAL OF THE CITY ENGINEER AS DETERMINED BY SOILS TESTS TAKEN AFTER COMPLETION OF
ROUGH GRADING.
32. ACTUAL THICKNESS OF A.C. PAVEMENT AND/OR BASE COURSE MATERIAL FOR STRUCTURAL STREET
SECTIONS SHALL BE RECOMMENDED BY A GEOTECHNICAL REPORT AND SUBMITTED TO THE CITY OF
FONTANA FOR APPROVAL UPON COMPLETION OF ROUGH GRADING.
33. ALL MANHOLES, CLEAN OUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED
GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING.
34. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING,
BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC
ENGINEER.
35. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS AND SIDEWALKS
AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE CITY ENGINEER.
36. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO
SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER.
UNQERGI
•J � '4
J
J
x
T
L
V
AI
ti
5'
MIN.
v EX. PAVEMENT
GRIND 0.10' MIN.
AND OVERLAY 0.10' MIN,
NEW PAVEMENT
SECTION
LAP JOIN DETAIL
NOT TO SCALE
CONSTRUCTION NOTES:
VICINI7 Y ASAP
NOT TO SCALE
LEGEND:
� o
CONSTRUCT COMMERCIAL DRIVEWAY PER CITY STD. NO. 1002, W=AS SHOWN ON PLAN
0
0
WATER
SEWER
J
SAN BERNARDINO AVE.
J
SOUTHERN CALIFORNIA EIDSON COMPANY
Q
CITY OF FONTANA
Z J
o
Q
70'
v 60'
_
<
`�
55'
15'
�
12'
43' 52' 23'
m
FONTANA, CA. 92335
Z I I
cr
,� ,_I_,
377 L.F.
,W 30'
VALLEY U
&L-
29
79-1.59 29
"
..•��
. .....:..........
rr----
.. ... 777777T7777`i-7-i7.7T rrrr�--.i'ry77>rr)�'''.J (
r: .. 11J11111111 L/✓_!✓11GLL.U,J111L1d_-J
10 AN BE
ARDI
0
m
0
FRWY _
EXISTING IMPROVEMENT
FAX (909) 283-5046
= PCC SURFACE
STREET CROSS-SECTION
10
UP
VALLEY BOULEVARD
NOT TO SCALE
ti
5'
MIN.
v EX. PAVEMENT
GRIND 0.10' MIN.
AND OVERLAY 0.10' MIN,
NEW PAVEMENT
SECTION
LAP JOIN DETAIL
NOT TO SCALE
CONSTRUCTION NOTES:
VICINI7 Y ASAP
NOT TO SCALE
ESTIMATED
QUANTITIES
UTILITY CONTACTS
LEGEND:
Q
CONSTRUCT COMMERCIAL DRIVEWAY PER CITY STD. NO. 1002, W=AS SHOWN ON PLAN
0
ELECTRICITY
WATER
SEWER
O
SAN BERNARDINO AVE.
J
SOUTHERN CALIFORNIA EIDSON COMPANY
Q
CITY OF FONTANA
Q
312 S.F.
300 N. PEPPER AVE.
_
<
`�
8353 SIERRA AVENUE
®
O f
3,200 S.F.
RIALTO CA. 92,376
m
FONTANA, CA. 92335
W
cr
,� ,_I_,
377 L.F.
UNDERGROUND: ( 909) 357-6233
VALLEY U
(909) 350-6632
"
BLVD
TRANSMISSION: (909) 875-5100
10 AN BE
ARDI
0
m
0
FRWY _
PIPELINES: (909) 657-1233
FAX (909) 283-5046
= PCC SURFACE
7
10
UP
RR
®
SLOVER
2 EACH
AVE
GENERAL TELEPHONE COMPANY
COMCAST CABLEVISION
ESTIMATED
QUANTITIES
UTILITY CONTACTS
LEGEND:
Q
CONSTRUCT COMMERCIAL DRIVEWAY PER CITY STD. NO. 1002, W=AS SHOWN ON PLAN
573 S.F.
ELECTRICITY
WATER
SEWER
O
CONSTRUCT 8" P.C.C. CURB AND GUTTER PER CITY STD. NO. 1000
78 L.F.
SOUTHERN CALIFORNIA EIDSON COMPANY
FONTANA. WATER COMPANY
CITY OF FONTANA
CONSTRUCT 6' WIDE P.C.C. SIDEWALK PER CITY STD. NO. 1006
312 S.F.
300 N. PEPPER AVE.
8440 NUEVO AVENUE
8353 SIERRA AVENUE
®
CONSTRUCT 6.5" A.C. MIN. OVER 12" MIN. OF 959 COMPACTED NATIVE SUBGRADE
3,200 S.F.
RIALTO CA. 92,376
FONTANA, CA. 92335
FONTANA, CA. 92335
5
SAW -CUT, REMOVE AND DISPOSE EXISTING A.C. PAVING
377 L.F.
UNDERGROUND: ( 909) 357-6233
ATTN: MICHAEL MCGRAW
(909) 350-6632
CF =
CURB FACE
TRANSMISSION: (909) 875-5100
(909) 822-2201
= EDGE OF PAVING
6
CONSTRUCT PARKWAY DRAIN PER SPPWC STANDARD NO. 151-2, S=48"
1 EACH
PIPELINES: (909) 657-1233
FAX (909) 283-5046
= PCC SURFACE
7
CONSTRUCT FIRE HYDRANT (SEPARATE PERMIT)
1 EACH
DISTRIBUTION: (909) 357-6233
®
ADJUST EXISTING WATER METER BOX TO GRADE
2 EACH
GAS
GENERAL TELEPHONE COMPANY
COMCAST CABLEVISION
®
PROTECT EXISTING POWER POLE
SOUTHERN CALIFORNIA GAS CO.
1400 E. PHILLIPS RANCH BLVD.
1205 DUPONT AVENUE
0
INSTALL STREET LIGHT (PER STREET LIGHT PLAN)
1 EACH
�- 1981 LUGONIA AVENUE
ONTARIO, CA. 91766
ONTARIO, CA. 91761
11
ADJUST TO GRADE EXISTING WATER VALVE
3 EACH
REDLANDS, CA. 92J74,
ATT'N. JOHN OATES
ATT'N: STEVE HOCK
(800) 422-4133
ATT'N: JACK HAYES
(909) 390-4738
O2
REMOVE AND DISPOSE EXISTING CHAIN LINK FENCE
142 L. F.
EMERGENCIES: (800) 427-2200
REMOVE AND DISPOSE EXISTING SHOULDER A.C. PAVING
2,900 S.F.
ENGINEER'S NOTE:
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES, CONDUITS OR ANY
OTHER STRUCTURES SHOWN ON THESE DRAWINGS WERE OBTAINED BY A SEARCH OF THE
AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO OTHER UTILITIES
OR STRUCTURES EXCEPT AS SHOWN ON THESE DRAWINGS. THE CONTRACTOR IS REQUIRED
TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THE
DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND RESPONSIBILITY FOR
UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN OR NOT SHOWN ON THESE DRAWINGS.
CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR
JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT,
INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, AND THAT THIS REQUIREMENT SHALL
APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND THAT THE
CONTRACTOR SHALL DEFEND, INDEMNIFY -AND HOLD THE COUNTY, THE OWNER AND THE
ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION
WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING
FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER.
BASIS
LEGEND:
lS
FL =
FLOWLINE ELEVATION
BEING
TC
= TOP OF CURB ELEVATION
RS
(X)
= EXISTING ELEVATION
TP
= TDP OF PAVEMENT
W =
WATER LINE
S =
SEWER LINE
G =
GAS LINE
FS
= FINISHED SURFACE
NG
= NATURAL GROUND
EP
= EDGE OF PAVING
CF =
CURB FACE
EP
= EDGE OF PAVING
= PCC PAVING
= PCC SURFACE
®=
EXISTING SHOULDER AC PAVING
REMOVAL
BENC
DESC
36'
ELEV
BASIS
OF BEARINGS
lS
THE
CENTERLINE OF VALLEY BOULEVARD
BEING
N89°38'1 1 "E
PER
RS
123/35