Loading...
HomeMy WebLinkAbout4950-1N W D z W r0 V z 75 0 OC Q W it � Z Z i i' (12'56112'1111P, i l..L..I 13' '( !! ; I z I I I 171 3 � Q 1 I ! ` i < � II I II ;. � (, MERRILL I�� m AVENUE � i. r �'� 1 3 430� ' ± L.F. �urJ 2 _ 3 I -- + L,F. 400 '' ---------------------------------------------------------------------- --------------------UY- - - - - - I• .IN -- C3 _ y! L'o 1I S C11 - _ jar- __�-�___ ! ____!- �.-_•-__�� i__r.___ N ! F! 1 i _ --------------- �u CU 0 _J_00 �._ G-__._ _-_.-_____._-.__--_._.-�___-�_.___-__.__.__ -1 _�____ _._____�__ - --------- q___ ___ cu I-_ ,_._._._-,____-___ ____ _ ___-___ ___ EX, R/W EXJ II y ' f 1'6114 I I � II j' 15 it I ►j II PER PLAT 0.03' LIP EXISTING CURB OR CURB AND GUTTER TRAFFIC SIGNAL INTERCONNECT/COMMUNICATION GENERAL NOTES 1. TRAFFIC SIGNAL INTERCONNECT SHALL CONFORM TO THESE PLANS, THE STATE OF CALIFORNIA STANDARD SPECIFICATIONS SECTION 86 AND STANDARD PLANS (DATED 2010), AND THE SPECIAL PROVISIONS. 2. ALL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA ENGINEERING DIVISION PRIOR TO COMMENCENT OF WORK. 3. THE CONTRACTOR SHALL REPAIR ALL DAMAGED LANDSCAPING AND IRRIGATION TO THE SATISFACTION OF THE ENGINEER. 4• CONDUIT SHALL NOT BE INSTALLED DIRECTLY OVER ANY UTILITY LINE (PARALLEL WITH THE LINE). UTILITY LINE CROSSINGS ARE ALLOWED. 5. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE CITY ENGINEER FOR EXACT EQUIPMENT LOCATIONS PRIOR TO FINAL PLACEMENT. 6. PULL BOXES AND SPLICE VAULTS SHALL NOT BE LOCATED IN DRIVEWAYS OR OTHER LOCATIONS WHICH MAY INTERFERE WITH THE MOVEMENT OF PEOPLE OR VEHICLES. PULL BOX LOCATIONS SHALL BE ADJUSTED AS NEEDED. 7. ALL PULL BOXES SHALL BE No. 6E AND CONDUIT SHALL BE 2" GALVANIZED RIGID METAL UNLESS OTHERWISE SHOWN. ALL SPLICE VAULTS SHALL BE TYPE P48 48.5%30.5%30" DEEP (INSIDE), FIBERGLASS, HAVE LOCKING LIDS, AND BE LABELED "COMMUNICATIONS". PULL BOXES AND SPLICE VAULTS SHALL BE INSTALLED IN ACCORDANCE WITH THE PROJECT DETAILS FOR PULL BOX AND SPLICE VAULT INSTALLATION. 8. WHERE CONDUIT IS INSTALLED AND DISTURBS EXISTING STRIPING, CONTRACTOR SHALL ARRANGE AND PAY FOR STRIPING. SEE SPECIAL PROVISIONS FOR CONTRACTOR RESPONSIBILITY FOR TEMPORARY PAVEMENT MARKINGS. HEADER I CUT J EXISTING 0.10 MIN. AC SURFACING NEW A.C. TACK COAT 2 -SACK ALL EDGES SLURRY BACKFILL (INITIAL POUR TO BE FLUSH WITH SURROUNDING SURFACE) 3" RIGID METAL CONDUIT (INSTALLED WITH 1' MIN. COVER) DUCT INSTALLATION AND TRENCH REPAIR DETAIL IN PAVED STREET N.T.S. DETAIL "C" 9. ALL PCC SIDEWALK DAMAGED BY THE CONTRACTORS OPERATIONS SHALL BE SAWCUT, REMOVED, AND REPLACED TO EXISTING EXPANSION/SCRIBE JOINTS. 10. LOCATION OF ALL UNDERGROUND FACILITITES ARE APPROXIMATE. THE CONTRACTOR SHALL POTHOLE TO DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS ON THE JOB SITE. HAND DIG UNTIL CLEAR OF OBSTRUCTIONS. PHONE UNDERGROUND SERVICE ALERT AT (800) 227-2600, TWO (2) WORKING DAYS BEFORE DIGGING. THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPENCIES OR CONFLICTS PRIOR TO DOING STREET WORK. 11. THE CONTRACTOR SHALL LOCATE, PROTECT, SHORE, BRACE, SUPPORT, AND MAINTAIN ALL EXISTING FACILITIES INCLUDING GAS, WATER, IRRIGATION, SEWER, POWER, STREET LIGHTS, TELEPHONE AND OTHER CONSTRUCTION WHICH MAY BE UNCOVERED OR OTHERWISE AFFECTED BY THE WORK. CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION AND PRESERVATION OF ALL SUCH FACILITIES IN THE AREA OF CONSTRUCTION, AND SHALL NOTIFY UTILITIES FORTY-EIGHT (48) HOURS IN ADVANCE OF ANY CONSTRUCTION. 12. ALL TRAFFIC CONTROL DEVICES SHALL BE IN PLACE BEFORE WORK IS STARTED. TRAFFIC CONTROL, WORK ZONES, AND LANE CLOSURES SHALL BE COMPLETELY DELINEATED BY CHANNELIZATION DEVICES AND SHIELDED BY BARRIERS TO EXCLUDE VEHICLE AND/OR PEDESTRIAN TRAFFIC. CONTRACTOR SHALL FOLLOW THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (CALIFORNIA MUTCD DATED JANUARY, 2012) FOR CONSTRUCTION AND MAINTENANCE WORK ZONES, CALTRANS STANDARD SPECIFICATIONS, AND STANDARD PLANS, DATED 2010. EXACT LOCATION OF ALL TRAFFIC CONTROL TO BE DETERMINED BY THE ENGINEER AND ADDITIONAL WARNING AND/OR CONSTRUCTION SIGNING MAY BE REQUIRED. DEVICES NO LONGER REQUIRED SHALL BE REMOVED AS SOON AS POSSIBLE. CONTRACTOR SHALL PROVIDE TRAFFIC CONTROL PLANS TO ENGINEER FOR APPROVAL PRIOR TO CONSTRUCTION. 0 O REV. REVISION DESCRIPTION 0 DIAL TWO WORKING BEFORE DAYS BEFORE YOU DIG You DIG TOLL FREE 1-800-227-2600 A PUBLIC SERVICEBY UNDERGROUND SERVICE ALERT W H LIJ = 0- U 0- D D W LLJ0 DATE I ENGR. I CITY I DATE 20' ± L.F. MERRILL AVENUE 1 3 Q 430' :E L.F. 8 ! ! ! 4 NT — I I I I N 75' +L F �----�-------;- o -----moi - -----J—_—_ `0 --- _- ___— ___-______--- -_______ _ ------------_ O L I r 25' ± L,F. 4 NOTE: THIS PARCEL (NO. 0194-041-29-0000) IS OWNED BY THE CITY OF FONTANA VETERANS PARK SITE 13. PEDESTRIAN TRAFFIC MUST BE MAINTAINED AT ALL TIMES. PEDESTRIANS MAY BE RELOCATED ONTO PRIVATE PROPERTY WITH OWNERS PERMISSION ONLY. 14. NO EQUIPMENT OR MATERIALS SHALL BE STORED ON SIDEWALK AT ANY TIME. 15. A 12" VERTICAL SEPARATION BETWEEN NEW CONDUITS AND OTHER UTILITIES SHALL BE MAINTAINED AT CROSSINGS. A 3' MIN. HORIZONTAL SEPARATION BETWEEN NEW CONDUITS AND POWER AND WATER UTILITIES THAT RUN PARALLEL SHALL BE MAINTAINED. A 3' (EXCEPT WHERE NOTED) MINIMUM SEPARATION BETWEEN CONDUIT AND SANITARY SEWER AND STORM DRAINS THAT RUN PARALLEL SHALL BE MAINTAINED, UNLESS OTHERWISE APPROVED BY THE ENGINEER. THE CONTRACTOR SHALL MAINTAIN A MINIMUM 3' CLEARANCE FOR ALL OTHER FACILITIES. 16. TRAFFIC SIGNAL CIRCUITS AND INTERCONNECT CONDUITS MAY NOT BE SHOWN. CONTRACTOR SHALL LOCATE ALL TRAFFIC SIGNAL CIRCUITS AND INTERCONNECT CONDUITS PRIOR TO ANY TRENCHING OR BORING. ALL TRAFFIC SIGNAL AND INTERCONNECT CONDUITS SHALL BE MAINTAINED AND PROTECTED. 17. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING RECORD DRAWINGS FOR ALL WORK THROUGHOUT THE COURSE OF CONSTRUCTION. 18. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING SURVEY MONUMENTS OR MARKERS DURING CONSTRUCTION. 19. SEE DRAWING NO. 4950 SHEET 2/2 FOR SPLICE DETAILS 20. SEE DRAWING NO. 4925 FOR TRAFFIC SIGNAL INSTALLATION PLAN SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH STANDARDS IN EFFECT. No. C 78044 Exp. 9-30-13 CIVIL i lmmmlmllw. L� LTJ Li z_ -I J bi z3 U 0 Lj LLJ0 TRAFFIC SIGNAL INTERCONNECT/COMMUNICATION CONSTRUCTION NOTES ❑1 FURNISH AND INSTALL TYPE P48 (SEE GENERAL NOTE #7) SPLICE BOX FURNISH AND INSTALL 3" CONDUIT PER DETAIL C. FURNISH AND INSTALL 96 STRAND S.M.F.O. CABLE. ❑3 COIL AN ADDITIONAL 50' OF 96 -STRAND SMFO CABLE FOR SLACK IN P48 BOX FURNISH AND INSTALL 2" CONDUIT IN JOINT TRENCH CONTAINING RUN FOR TRAFFIC SIGNAL SEE TRAFFIC SIGNAL INSTALLATION PLAN, DRAWING 4925. FURNISH AND INSTALL 12 STRAND S.M.F.O. CABLE. �5 FURNISH AND INSTALL 2" CONDUIT. FURNISH AND INSTALL 12 STRAND S.M.F.O. CABLE. 66 COIL AN ADDITIONAL 20' OF 12 -STRAND SMFO CABLE FOR SLACK IN EXISTING PULLBOX PULL 12 STRAND S.M.F.O. CABLE INTO TRAFFIC SIGNAL CONTROLLER CABINET FURNISH AND INSTALL SPLICE ENCLOSURE. FUSION SPLICE DESIGNATED FIBERS FROM 96 -STRAND SMFO TO 12 -STRAND SMFO PER FIBER SPLICE SCHEDULE (SEE DWG. 4950 2/2). COIL A MINIMUM OF 16' OF 12 -STRAND SMFO CABLE AND 50' OF 96 -STRAND SMFO CABLE FOR SLACK IN SPLICE VAULT SO = SIGNALIZED INTERSECTION Prepared Under The Supervision Of : DRAWN BY: DT DESIGNED BY: DT Date 2 • 7�3/�/ CHECKED BY: Noel! Castillo, R.C.E. 78044 MP mow SCALE; *40 CITY OF FONTANA, CALIFORNIA FIBER OPTIC INTERCONNECT PLAN MERRILL AVENUE 1:40 0 AVENUE 0 PALMETTO AVENUE DATE 7/26/2012 CiVE DRAWING NO.: DATEZ 3( ( 4950 CnYENGINEER R.C.E. 51152 2